Lancom R884VA User Manual

Gigabit Ethernet 10/100/1000
ISDN 3 ISDN 4
TE / NT NT
ISDN 1 ISDN 2
TE / NT NT
VDSL / ADSL
LANCOM R884VA
Quick Reference Guide
4
Please observe the following when setting up the device
A For devices to be
operated on the desktop, please attach the adhesive rubber footpads
A Do not rest any objects
on top of the device and do not stack multiple devices
Power
A Keep the ventilation
slots on the side of the device clear of obstruction
A In case of wall
mounting, use the drilling template as supplied
A Rack installation with
the optional LANCOM Rack Mount (not supplied)
LANCOM 1681V
VDSL
ISDN Status
ETH 2
VPN
ETH 3
ETH 4
Online
ETH 1
a b c
a
VDSL interface
Use the supplied DSL cable for the IP-based line to connect the VDSL interface and the provider's telephone socket. (For more information, please contact your Internet service provider.)
b
Ethernet interface
Use the cable with the green-colored connectors to connect one of the interfaces ETH 1 to ETH 4 to your PC, IP telephone or a LAN switch.
c
Serial interface
Conguring the device via
the serial interface requires a serial conguration cable (available as an accessory).
d e f
d
ISDN interface
ISDN 1 + 2 Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS.
ISDN 3 + 4 Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is switchable in LCOS.
e
USB interface
You can use the USB interface to connect a USB printer or a USB drive.
f
Power
When connecting the cable to the device, turn the bayonet connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
Online
Power
DSL
ISDN 1
a c eb gfd h
a Power
Off Device switched off
Green, permanently Device operational
Green / red, blinking No password set. Without a password
Red, blinking Charge or time limit reached
b Online
Off WAN connection inactive
Green, permanently WAN connection active
Red, permanently WAN connection error
c DSL
Off Interface deactivated
Green, permanently DSL connection active
Green, ickering DSL data transfer
Red, ickering DSL transfer error
Red / orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
Green, blinking DSL connecting
d ISDN
Off Interface deactivated
Green, permanently D-channel active
Green, blinking ISDN connected
Red, ickering ISDN transfer error
Red / orange, blinking ISDN hardware error
Red, permanently ISDN connection not enabled
Orange, blinking ISDN connecting
the conguration data in the device is
unprotected.
ISDN 2
ISDN 3
ISDN 4
ETH 1
ETH 3
ETH 4
VoIP
VPN
ETH 2
e ETH
Off No networking device attached
Green, permanently Connection to network device
Green, ickering Data transmission
operational, no data trafc
f VoIP
Off No SIP accounts dened or VCM is off
Green, permanently All dened and active SIP accounts
Red, permanently Not all of the dened and active SIP
Red or green,
inverse ashing
(outgoing) were successfully registered
accounts were registered (possibly still in process)
Number of currently used lines (connecting or connected)
g VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, ashing VPN connecting
h Reset
Reset switch Operated e.g. with a paper clip
short press > Restart the device long press > Reset the device
LANCOM R884VA
Reset
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
Power consumption Max. ca. 14 W
Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; measures
Number of fans None; fanless design, no rotating parts, high MTBF
Interfaces
WAN: VDSL2 A VDSL2 as per ITU G.993.2; proles 8a, 8b, 8c, 8d, 12a, 12b, 17a
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server),
ISDN 1 / ISDN 2
ISDN 3 / ISDN 4
Cong (Com) / V.24 Serial conguration interface / COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Declaration of Conformity
Hereby, LANCOM Systems declares that this device is in compliance with Directives 2014/30/EU and 2014/35/EU. The full text of the EU declaration of conformity is available at the following internet address: www.lancom-systems.com/ce/
Package content
Documentation Quick Reference Guide (DE/EN), Installation Guide (DE/EN)
Cable 1 Ethernet cable, 3 m (kiwi colored connectors); 1 DSL cable for an IP-based line, 4.25 m;
Power adapter External power supply adapter (230 V); NEST 12 V / 1.5 A DC/S; barrel connector 2.1 / 5.5 mm
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
210 x 45 x 140 mm (W x H x D)
A Compatible to VDSL2 from Deutsche Telekom A ADSL conformity according to: ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO,
ADSL2 over ISDN as per ITU G.992.3 Annex B, ADSL over ISDN as per ITU G.992.1 Annex B.
A Supports just one virtual connection at a time in ATM (VPI-VCI pair)
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically
disabled in the LCOS conguration.
serial devices (COM-port server) or USB drives (FAT le system).
ISDN 1+2: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to the settings, connect the light-blue ISDN cable either to the NTBA or the ISDN terminal device. ISDN 3+4: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to the ISDN interface.
for optional connection of analog / GPRS modems. Supports internal COM-port server and provides transparent asynchronous serial-data transfer via TCP.
DHCP), RIP-1, RIP-2, VLAN
2 ISDN cables, 3 m (light-blue connectors)
bayonet; LANCOM item no. 111301
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111635/0617
MOUNTING AND CONNECTING THE DEVICE
Loading...