MOUNTING AND CONNECTING THE DEVICE
TECHNICAL DETAILS
LANCOM R883+
Quick Reference Guide
Cloud-ready
VDSL
a b c d e f
VDSL interface
a
Use the supplied DSL cable for the IP-based line to connect the
VDSL interface and the provider’s telephone socket. For more
infor mation, please contact your Internet service provider.
Ethernet interfaces
b
Use the cable with the kiwi-colored connectors to connect one of
the interfaces ETH 1 to ETH 4 to your PC or a LAN switch.
Analog interfaces
c
Connect analog terminal devices to the analog interfaces either
directly via RJ11, or with the help of the enclosed TAE adapters,
either directly or via the additionally enclosed RJ11 twin adapters.
Conguration interface
d
Use a serial conguration cable to connect the serial interface
(COM) to the serial interface of the device you want to use for
conguring / monitoring (separately available).
Please observe the following when setting up the device
A Do not rest any objects on top of the device
A For devices to be operated on the desktop, please attach the
adhesive rubber footpads
A In case of wall mounting, use the drilling template as supplied
Gigabit Ethernet 10/100/1000
Hardware
Power supply 12 V DC, external power adapter (230 V); bayonet connector to secure against disconnection
TE / NT NT
a c eb gfd ih j
Analog 1/3Analog 2/4
ISDN interfaces
e
ISDN 1:
Internal (NT) or external (TE) ISDN bus.
This feature is controlled by LCOS.
ISDN 2:
Internal (NT) ISDN bus.
A 100-Ohm resistor for line termination is
switchable in LCOS.
USB interface
f
You can use the USB interface to connect a USB printer or a
USB memory stick.
Power
g
After connecting the cable to the device, turn the bayonet
connector 90° clockwise until it clicks into place.
Use only the supplied power adapter.
LANCOM 1681V
VDSL
ISDN Status
ETH 2
VPN
ETH 3
ETH 4
Online
ETH 1
Power
A Keep the ventilation slots on the side of the device clear
of obstruction
A Rack installation with the optional LANCOM Rack Mount
(separately available)
ISDN 1 ISDN 2
g
a Power
Off Device switched off
Green, permanently* Device operational, resp. device paired /
Red / green blinking Conguration password not set. Without a
Red blinking Charge or time limit reached
1x green inverse
blinking*
2x green inverse
blinking*
3x green inverse
blinking*
claimed and LANCOM Management Cloud
(LMC) accessible
conguration password, the conguration
data in the device is unprotected.
Connection to the LMC active, pairing OK,
device not claimed
Pairing error, resp. LMC activation code
not available
LMC not accessible, resp. communication
error
b Online
Off WAN connection inactive
Green, permanently WAN connection active
Red, permanently WAN connection error
c DSL
Off Interface deactivated
Green, permanently DSL connection active
Green, ickering DSL data transfer
Red, ickering DSL transfer error
Red / orange, blinking DSL hardware error
Orange, blinking DSL training
Orange, permanently DSL sync
Green, blinking DSL connecting
d Analog
Off Interface deactivated
Green, permanently Interface activated
Orange, blinking Incoming call
Green, blinking Connection active
*) The additional power LED statuses are displayed in 5-seconds
rotation if the device is congured to be managed by the LANCOM
Management Cloud.
e ISDN
Off Interface deactivated
Green, permanently D-channel active
Green, ickering ISDN data transfer
Red, ickering ISDN transfer error
Red / orange, blinking ISDN hardware error
f ETH
Off No networking device attached
Green, permanently Connection to network device operational,
Green, ickering Data transmission
no data trafc
g WLAN
Off No Wi-Fi network dened or Wi-Fi module
Green, permanently At least one Wi-Fi network is dened and
Green, blinking DFS scanning or other scan procedure
deactivated. The Wi-Fi module is not
transmitting beacons.
Wi-Fi module activated. The Wi-Fi module
is transmitting beacons.
h VoIP
Off No SIP accounts dened or VCM is off
Green, permanently All dened and active SIP accounts
Red, permanently Not all dened and active SIP accounts
Red or green,
inverse ashing
(outgoing) were successfully registered
were registered (possibly still in process)
Number of currently used lines (connecting
or connected)
i VPN
Off VPN connection inactive
Green, permanently VPN connection active
Green, ashing VPN connecting
j Reset
Reset button Operated e.g. with a paper clip
a short press: Restart the device
a long press: Reset the device
Power consumption Max. ca. 18 W
Environment Temperature range 0–40 °C; humidity 0–95 %; non-condensing
Housing Robust synthetic housing, rear connectors, ready for wall mounting, Kensington lock; measures
Number of fans One quiet fan
Interfaces
WAN: VDSL2 a VDSL2 as per ITU G.993.2; proles 8a, 8b, 8c, 8d, 12a, 12b, 17a, 35b
Wi-Fi a Frequency band: 2400-2483.5 MHz (ISM) or 5150-5825 MHz (restrictions vary between
ETH 4 individual ports, 10 / 100 / 1000 Mbps Gigabit Ethernet, by default set to switch mode.
USB USB 2.0 hi-speed host port for connecting USB printers (USB print server),
ISDN 1 / ISDN 2 ISDN 1: Internal (NT) or external (TE) ISDN bus. This feature is controlled by LCOS. According to
Analog 1 / Analog 2
Analog 3 / Analog 4
Cong (Com) / V.24 Serial conguration interface/COM-port (8-pin mini-DIN): 9,600 - 115,200 baud, suitable for
WAN protocols
VDSL, ADSL, Ethernet PPPoE, PPPoA, IPoA, Multi-PPPoE, ML-PPP, PPTP (PAC or PNS) and IPoE (with or without
ISDN DSS1 (Euro-ISDN), PPP, X75, HDLC, ML-PPP, V.110/GSM/HSCSD
Declaration of Conformity
Hereby, LANCOM Systems declares that this radio equipment is in compliance with Directive 2014/53/EU. The full text
of the EU declaration of conformity is available at the following internet address: www.lancom-systems.com/ce/
Package content
Manual Quick Reference Guide (DE/EN); Installation Guide (DE/EN)
Cable 1 Ethernet cable, 3 m (kiwi colored connectors); 1 DSL cable for an IP-based line, 4.25 m;
Adapters 4 TAE adapters (RJ11 - TAE), 2 RJ11 twin adapters
Power adapter External power supply adapter (230 V); NEST 12 V / 2 A DC/S; barrel / bayonet (EU),
This product contains separate open-source software components which are subject to their own licenses, in particular
the General Public License (GPL). The license information for the device rmware (LCOS) is available on the device‘s
WEBcong interface under “Extras > License information“. If the respective license demands, the source les for the
corresponding software components will be made available on a download server upon request.
210 x 45 x 140 mm (W x H x D)
a VDSL2 vectoring as per ITU G.993.5 (G.vector)
a Compatible to VDSL2 from Deutsche Telekom
a VDSL Supervectoring as per ITU G.993.2 (Annex Q)
a Compatible to U-R2 from Deutsche Telekom (1TR112)
a ADSL2+ over ISDN as per ITU G.992.5 Annex B/J with DPBO, ITU G.992.3, and ITU G.992.1
a Supports just one virtual connection at a time in ATM (VPI-VCI pair)
countries)
a Radio channels 2.4 GHz: Up to 13 channels, max. 3 non-overlapping (2.4-GHz band)
a Radio channels 5 GHz: Up to 26 non-overlapping channels (channels available vary
according to country regulations; DFS for automatic dynamic channel selection required)
Up to 3 ports can be operated as additional WAN ports. Ethernet ports can be electrically
disabled in the LCOS conguration.
serial devices (COM-port server) or USB drives (FAT le system)
the settings, connect the light-blue ISDN cable either to the NTBA or the ISDN terminal device.
ISDN 2: Internal (NT) ISDN bus. Use the light-blue ISDN cable to connect the ISDN device to
the ISDN interface.
Use the cable of your analog devices to connect them with the analog interfaces. If necessary,
use the enclosed adapter.
optional connection of analog/GPRS modems. Supports internal COM-port server and provides
transparent asynchronous serial-data transfer via TCP.
DHCP), RIP-1, RIP-2, VLAN
1 ISDN cable, 3 m (light-blue connectors)
LANCOM item no. 111303
LANCOM, LANCOM Systems and LCOS are registered trademarks. All other names or descriptions used may be trademarks or registered
trademarks of their owners. Subject to change without notice. No liability for technical errors and/or omissions. 111716/0518