SUB-K SUBMERSIBLE PUMP PROTECTION SEPARATORS
INSTALLATION INSTRUCTIONS
APPLICATION
LAKOS SUB-K Series Separators are engineered for the removal of sand and other heavy, suspended particles
from domestic and private water well systems with flow rates of 3 - 99 U.S. gpm (.7 - 23 m3/hr) and well I.D.’s of
5 inches or larger.
OPERATION
When the pump is operating, sandy water is drawn first through the SUB-K Separator ’s inlet slots. Centrifugal
action separates the sand, causing the particles to gently fall to the bottom of the separator. The SUB-K’s
“flapper valve” remains closed while the pump is in operation. The sand-free water spirals upward, through the
center vortex/outlet, into the pump enclosure shell and to the pump. When the pump shuts off, the SUB-K’s
flapper valve will open, allowing accumulated sand to discharge deep into the well. NOTE: To assure adequate
purging of separated particles, SUB-K Separators must be installed on water systems that operate at least
somewhat intermittently, typically for no more than two continuous hours. This time may vary, depending on the
concentration of sand in the well.
IMPORTANT NOTES
• Installation instructions assume that pump is hanging vertically, attached to column pipe and ready for
lowering into the well.
• Use caution during the lowering process. Catching the pump or SUB-K unit on the well casing could cause
damage that might affect proper performance.
• All SUB-K models are designed to accommodate the typical pump diameter of 33⁄4-inches (96 mm). Maximum
length of pump motor and inlet screen area (combined) cannot exceed 38 inches (965 mm). Consult factory
for special requirements and/or application assistance.
• Should the submersible pump ever need to be pulled or serviced, be sure to inspect the SUB-K Separator,
especially for clogged inlet ports or damage to the flapper valve.
• Maximum particle concentration: 550 ppm.
(illustration on reverse)
INSTALLATION
(G)
Minimum
submergence of
SUB-K Separator
below pumping water
level: 30 feet (9.2 m)
(F)
Recommended
minimum clearance
to bottom of well:
20 feet (6.1 m)
Sand accumulates above
the LAKOS Separator’s
flexible “Flapper Valve” until
pump shuts off, releasing
separated particles deep
into well
(E)
LAKOS SEPARATOR
LAKOS Separator's
tangential inlet slots
Water well casing
SUB-K
SEPARATOR
(D)
SUB-K Pump
Enclosure Shell
(C)
Submersible pump
suction screen
(B)
Pump's electrical
wire shield
(A)
SUB-K shell is
clamped to pump
(above pump suction)
Sand-free water is pumped
to the surface.
1. Apply a small amount of non-petroleum lubricant to the rubber seal (K) on the SUB-K’s Pump
Enclosure Shell.
2. Slide the Pump Enclosure Shell (D) over the submersible pump suction screen (C). A notch (J) is provided
on the rubber seal to accommodate the pump’s drop-wire shield (B). If necessary, trim the rubber seal or cut
away the drop-wire shield 4 inches (102 mm) up from the submersible pump suction screen (C).
3. Tighten the rubber seal around the pump using the large, stainless steel adjustable clamp (H) at a point
4 inches (102 mm) above the pump’s suction (A).
4. The SUB-K Separator (E) can now be
attached onto the bottom of the Pump
Enclosure Shell. Use the self-tapping screws
for Model SUB-99-6-K or threaded
connections for all other SUB-K models.
5. Lower the pump and SUB-K unit into the well
to a depth that allows the Separator to be
submerged at least 30 feet (9.2 m) below the
pumping water level (G) and at least 20 feet
(6.1 m) above the bottom of the well (F).
6. Run water system in the normal manner. The
LAKOS SUB-K Separator will operate from
the flow of the water and will require no
routine maintenance.
PUMP ENCLOSURE SHELL
(Top View)
1365 N. Clovis Avenue • Fresno, California 93727 USA
Telephone: (559) 255-1601 • Fax: (559) 255-8093
Toll-Free: (800) 344-7205 (USA, Canada & Mexico)
Printed on recycled paper
(H)
Adjustable
clamp
(J)
Notch for
pump’s
electrical cord
shield
(K)
Rubber seal is
clamped onto
pump (above
pump’s suction)
www.lakos.com • E-mail: info@lakos.com
LS-452B (Rev. 6/99)