Lab.gruppen FP+ FP 10000Q, FP+ FP 13000, FP+ FP 6000Q, FP+ FP 7000, FP 13000 Specifications

...
Voltage Peak Limiter Load vs Power Tables
FP+ Series: Dedicated Touring Amplifiers
FP+ Series amplifiers include the user-definable Voltage Peak Limiter (VPL) function. Rear-panel DIP-switch settings allow the output voltage
to be adjusted and consequently the output power available. The following tables provide information, for the four FP+ Series models, about
resultant output power at typical loads ( single channel and bridged operation ) with the available VPL settings.
VPL Setting
195 V 195 138 1200 2400 4800 6500 170 V 170 120 860 1720 3445 6500 140 V 140 99 620 1245 2485 4970 116 V 116 82 445 885 1770 3540 100 V 100 70 320 640 1275 2550
80 V 80 57 230 460 925 1850 66 V 66 47 170 340 665 1330 54 V 54 38 120 240 480 960
VPL Setting
195 V 390 276 4800 9600 13000 n.r. 170 V 340 240 3445 6890 13000 n.r. 140 V 280 198 2485 4970 9940 n.r. 116 V 232 164 1770 3540 7080 n.r. 100 V 200 142 1275 2550 5100 n.r.
80 V 160 114 925 1850 3700 n.r. 66 V 132 94 665 1330 2665 n.r. 54 V 108 76 480 960 1920 n.r.
Voltage Peak Limiter
Output power bridged per two channels
Load
FP 13000
Voltage Peak Limiter
Output power per channel (W)
Load
VPL Setting
155 V 155 110 750 1500 3000 3500 121 V 121 86 460 915 1830 3500 101 V 101 70 320 640 1275 2550
83 V 83 59 215 430 860 1720 70 V 70 49 155 305 615 1225 56 V 56 40 100 195 390 785 47 V 47 33 70 140 275 550 38 V 38 27 45 90 180 360
VPL Setting
155 V 310 220 3000 6000 7000 n.r. 121 V 242 172 1830 3660 7000 n.r. 101 V 202 140 1275 2550 5100 n.r.
83 V 166 118 860 1720 3445 n.r. 70 V 140 98 615 1225 2450 n.r. 56 V 112 80 390 785 1570 n.r. 47 V 94 66 275 550 1105 n.r. 38 V 76 54 180 360 720 n.r.
FP 7000
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load
Lab.gruppen ab Sweden
internationaL contact info@Labgruppen.com | uS contact infouS@tceLectronic.com
www.labgruppen.com
FP+ Series: Dedicated Touring Amplifiers. Voltage Peak Limiter Load vs Power Tables
VPL Setting
150 V 150 106 620 1240 2485 2500 121 V 121 86 435 870 1740 2500 101 V 101 70 315 625 1250 2500
83 V 83 59 225 450 900 1805 70 V 70 49 160 315 630 1260 56 V 56 40 11 0 220 435 870 47 V 47 33 80 155 315 625 38 V 38 27 55 11 0 220 440
VPL Setting
150 V 300 212 2485 4970 5000 n.r. 121 V 242 172 1740 3480 5000 n.r. 101 V 202 140 1250 2500 5000 n.r.
83 V 166 118 905 1810 3615 n.r. 70 V 140 98 630 1260 2520 n.r. 56 V 112 80 435 870 1740 n.r. 47 V 94 66 315 625 1250 n.r. 38 V 76 54 220 440 880 n.r.
FP 10000Q
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load
VPL Setting
101 V 101 70 320 640 1275 1500
83 V 83 59 215 430 860 1500 70 V 70 49 155 305 615 1225 56 V 56 40 100 195 390 785 47 V 47 33 70 140 275 550 38 V 38 27 45 90 180 360
VPL Setting V peak Vrms
101 V 202 140 1275 2550 3000 n.r.
83 V 166 118 860 1720 3000 n.r. 70 V 140 98 615 1225 2450 n.r. 56 V 112 80 390 785 1570 n.r. 47 V 94 66 275 550 1105 n.r. 38 V 76 54 180 360 720 n.r.
FP 6000Q
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load
Item no. VPL-FP+