Voltage Peak Limiter Load vs Power Tables
FP+ Series: Dedicated Touring Amplifiers
FP+ Series amplifiers include the user-definable Voltage Peak Limiter (VPL) function. Rear-panel DIP-switch settings allow the output voltage
to be adjusted and consequently the output power available. The following tables provide information, for the four FP+ Series models, about
resultant output power at typical loads ( single channel and bridged operation ) with the available VPL settings.
VPL Setting
195 V 195 138 1200 2400 4800 6500 170 V 170 120 860 1720 3445 6500 140 V 140 99 620 1245 2485 4970 116 V 116 82 445 885 1770 3540 100 V 100 70 320 640 1275 2550
80 V 80 57 230 460 925 1850 66 V 66 47 170 340 665 1330 54 V 54 38 120 240 480 960
VPL Setting
195 V 390 276 4800 9600 13000 n.r. 170 V 340 240 3445 6890 13000 n.r. 140 V 280 198 2485 4970 9940 n.r. 116 V 232 164 1770 3540 7080 n.r. 100 V 200 142 1275 2550 5100 n.r.
80 V 160 114 925 1850 3700 n.r. 66 V 132 94 665 1330 2665 n.r. 54 V 108 76 480 960 1920 n.r.
Voltage Peak Limiter
Output power bridged per two channels
Load
FP 13000
Voltage Peak Limiter
Output power per channel (W)
Load
VPL Setting
155 V 155 110 750 1500 3000 3500 121 V 121 86 460 915 1830 3500 101 V 101 70 320 640 1275 2550
83 V 83 59 215 430 860 1720 70 V 70 49 155 305 615 1225 56 V 56 40 100 195 390 785 47 V 47 33 70 140 275 550 38 V 38 27 45 90 180 360
VPL Setting
155 V 310 220 3000 6000 7000 n.r. 121 V 242 172 1830 3660 7000 n.r. 101 V 202 140 1275 2550 5100 n.r.
83 V 166 118 860 1720 3445 n.r. 70 V 140 98 615 1225 2450 n.r. 56 V 112 80 390 785 1570 n.r. 47 V 94 66 275 550 1105 n.r. 38 V 76 54 180 360 720 n.r.
FP 7000
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load
Page 2
Lab.gruppen ab Sweden
internationaL contact info@Labgruppen.com | uS contact infouS@tceLectronic.com
www.labgruppen.com
FP+ Series: Dedicated Touring Amplifiers. Voltage Peak Limiter Load vs Power Tables
VPL Setting
150 V 150 106 620 1240 2485 2500 121 V 121 86 435 870 1740 2500 101 V 101 70 315 625 1250 2500
83 V 83 59 225 450 900 1805 70 V 70 49 160 315 630 1260 56 V 56 40 11 0 220 435 870 47 V 47 33 80 155 315 625 38 V 38 27 55 11 0 220 440
VPL Setting
150 V 300 212 2485 4970 5000 n.r. 121 V 242 172 1740 3480 5000 n.r. 101 V 202 140 1250 2500 5000 n.r.
83 V 166 118 905 1810 3615 n.r. 70 V 140 98 630 1260 2520 n.r. 56 V 112 80 435 870 1740 n.r. 47 V 94 66 315 625 1250 n.r. 38 V 76 54 220 440 880 n.r.
FP 10000Q
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load
VPL Setting
101 V 101 70 320 640 1275 1500
83 V 83 59 215 430 860 1500 70 V 70 49 155 305 615 1225 56 V 56 40 100 195 390 785 47 V 47 33 70 140 275 550 38 V 38 27 45 90 180 360
VPL Setting V peak Vrms
101 V 202 140 1275 2550 3000 n.r.
83 V 166 118 860 1720 3000 n.r. 70 V 140 98 615 1225 2450 n.r. 56 V 112 80 390 785 1570 n.r. 47 V 94 66 275 550 1105 n.r. 38 V 76 54 180 360 720 n.r.
FP 6000Q
Voltage Peak Limiter
Output power per channel (W)
Load
Voltage Peak Limiter
Output power bridged per two channels
Load