Lab.gruppen fP FP 6400, FP 6400 Specifications

POWER AMPLIFIER
fP 6400
KEY FEATURES:
2 1300 watts @ 8 2 2300 watts @ 4 2 3200 watts @ 2
(Measured just below clip level, with both channels driven)
Compact design, 2U high
Low weight, 10 kg (22 lbs)
MLS™ Switch: Lab.gruppen’s
NEW FEATURES:
Multiple positions gain switch
Intercooler
with front-to-rear airflow and easily accessible dust filters
Improved low-end power
bandwidth
Link connector with XLR-type
connector
Bridged mono outputs in one
Speakon
Extruded front panel for
increased stability
®
cooling system
®
connector
The fP 6400 is a lightweight and space-saving power amplifier, ideal for use in high quality touring sound systems as well as in demanding permanent installations.
Heat and cooling are fundamental problems in extreme high power amplifiers such as the fP 6400. Already in 1990, Lab.gruppen patented a high efficiency amplifier, in fact an evolution of the Class D amplifier. Lab.gruppen therefore call it Class TD. It attains the same high efficiency as Class D, but avoids its drawbacks. Class D has a power-amplifier topology using Pulse Width Modulation (PWM) to achieve high efficiency, but it needs a recovery filter between the output stage and the loudspeaker. Lab.gruppen’s Class TD amplifiers do not need this filter and this is one reason why the Lab.gruppen Class TD obtains the same sonic quality as a traditional Class AB amplifier.
Besides the traditionally superb Lab.gruppen sonic performance, fP 6400 offers a full
line of important features:
Regulated switch mode power supply
Today there are many lightweight, switch-mode amplifiers in the market. However, the unique Lab.gruppen switch-mode power supply technology offers a number of essential advantages that make it superior to other and seemingly similar power supply designs. The most important features are the regulated power supply and the extreme power efficiency. The regulated power supply easily deals with a very high variation in the AC mains voltage: it can drop by up to 20% below its nominal level – e.g. to 180 V (90 V) instead of 230 V (115 V) – without any problem. Perhaps even greater benefits result from the extreme efficiency of Lab.gruppen amplifiers: only a fraction of the energy from the AC mains is turned into heat. A regulated power supply also presents some other sonic advantages, such as better cone control and the same fast response as a conventional power supply.
Multiple positions Gain switch
To meet the demands for a flexible gain structure in the system, Lab.gruppen offers a multiple position gain DIP switch. The maximum amplifier gain can be set to all industry standards: 20, 23, 26, 29, 32, 35, 38 and 41 dB.
Sophisticated protection circuitry, combining:
– DC protection; protects against infrasonic signals – VHF protection; protects the loudspeakers against strong very high frequency non-
musical signals above the audible range. – Thermal protection; prevents the amplifier from being overheated. The protection indicators on the front panel are switched on, as a warning, before the protection process is initiated. – AC protection; shuts down the power supply if the line voltage is outside the operating voltage. – Clip limiter; prevents severely clipped waveforms from reaching the loudspeakers, whilst maintaining full peak power.
SPECIFICATIONS
fP 6400
Max output power
1)
EIA EIA EIA EIA FTC EIA at 1 kHz and 1% THD 20–20 kHz at 0.1% THD MLS-switch –5 dB –4 dB –2 dB 0 dB Full 0 dB Full
16 per channel 220 W 260 W 410 W 650 W 640 W 8 per channel 430 W 520 W 820 W 1300 W 1280 W 4 per channel 830 W 1000 W 1600 W 2300 W 2200W 2 Ω per channel 1660 W 2000 W 2400, 3050
3)
W 29002), 3200
3)
W 2500 W
16 bridged 860 W 1040 W 1640 W 2600 W 2500 W 8 bridged 1660 W 2000 W 3200 W 4600 W 4400 W 4 bridged 3400 W 4000 W 4800, 6100
3)
W 58002), 6400
3)
W 5000 W
Max output voltage
8 ohms load 62 Vrms 70 Vrms 85 Vrms 104 Vrms Peak voltage, no load 88 V 101 V 121 V 149 V
Distortion etc.
THD 20Hz-20kHz and 1W to full power 0.1 % THD @ 1kHZ and –1dB under clip 0.04 % DIM 30 at –3dB under clip 0.06 %
Power 230 V version 115 V version
Operation voltage 130 V–265 V AC 65 V–135 V AC Minimum start voltage 175 V 85 V AC Full output power at 4ohms 180 V–265 V AC 90 V–130 V AC
Hum and Noise <–110 dB
Peak inrush current (Soft start limited) 5 A 5 A
Channel separation @10kHz 70 dB
Current Draw @ 4ohms
Output impedance 60 m
Quiescent power (no load) 1 Arms 2 Arms 1/8 of full power (–9 dB) 6 Arms 12 Arms
Slew Rate 20 V/␮s
1/3 of full power (–5 dB) 14 Arms 28 Arms At full power (0 dB) 20 Arms 40 Arms
Inputs
@1 kHz 1% THD (AFS limited) (AFS limited) Gain, selectable [dB] 20, 23, 26, 29, 32, 35, 38, 41 Impedance 20 kohm Common mode rejection 50 dB
Net Dimensions
mm 483 (19˝) W 88 H 347 D
inch 19˝ W 3.5˝ H 13.7˝D
Front Panel
Gain controls (2) channel A, B 31 pos detent Clip Indicator (2) red LEDs Output headroom
Shipping Dimensions
mm 560 W 180 H 500 D
inch 22˝ W 7.1˝ H 19.7˝D
indicators (10) green LEDs Fast peak – slow release Temp Indicator (2) yellow LEDs 80°C at heatsink VHF indicator (2) yellow LEDs >12 kHz at full power On Indicator (2) green LEDs DC rail voltage for
Weight
Net 10 kg (22 lbs)
Shipping 11.6 kg (25.6 lbs)
channel A and B AC Indicator (1) green LED AC power present AFS Indicator (1) green LED Fuse saver activated
Rear Panel
Input connectors (2) Neutrik Combo XLR type, 3 pin
and 1/4˝ jack Link connector (2) XLR type, 3 pin male Output connectors (2) Neutrik 4-pole Speakon® connectors
Switches: Clip limiter A and B On–Off (switchable) MLS switch 0, –2, –4, –5 dB Link-switch Ch. A–B
Approvals
CE: Emission EN 55 103-1, E3 Immunity EN 55 103-2, E3, with S/N below 1% at normal operation level Safety EN 60065, class I ETL listed: Conforms to ANSI/UL STD 6500 and Certified to CAN/CSA E60065-00 FCC: Complies with Class B digital device, Part 15 of the FCC Rules.
NOTES:
1) Specifications measured with 230 V AC
2) Component tolerance dependent
3) Continuous power, one channel driven or peak power both channels driven (Thermal protection may occur at high continuous power)
4) Normal operation level 1/8 of full power or –9 dB below clip level.
Lab.gruppen reserve the right to alter functions or the specification without prior notice.
4)
Lab.gruppen AB, Gullregnsvägen 16, SE-434 44 Kungsbacka, Sweden.
Tel +46 300 56 28 00 Fax +46 300 56 28 99 e-mail: info@labgruppen.com www.labgruppen.com