Lab.gruppen E 8-2 User Manual [en, de, es, fr]

Item no. QSG-ES
E SERIES
Dedicated installation amplifiers
Quick Start Guide
Guide de prise en main
Das Wichtigste in Kürze
Guía de Inicio Rápido
1
Contents
4 English - Quick start guide
7 Chinese -
10 Japanese -
13 French - Guide de prise en main
16 German - Das Wichtigste in Kürze
19 Spanish - Guía de Inicio Rápido
3
Introduction
The information contained in this Quick Start Guide is sufcient for proper installation of E Series ampliers, and for conguration of
settings in typical applications. Please refer to the full Operation Manual for detailed information on maintenance, cooling requirements,
warranty, and conguration for complex installations .
StandardsImportant safety instructions
1. Read these instructions.
2. Keep these instructions
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the
provided plug does not t into your outlet, consult an electrician for
replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specied by the manufacturer.
12. Use only with a cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. WARNING: To red uce the ri sk of re of electric sho c k, do not expose this apparatus to rain or moisture.
16. Do not expose this equipment to dripping or splashing and ensure
that no objects lled with liquids, such as vases, are placed on the
equipment.
17. Do not connect the unit’s output to any other voltage source, such as battery, mains source, or power supply, regardless of whether the unit is turned on or off.
18. Do not remove the top (or bottom) cover. Removal of the cover will expose hazardous voltages. There are no user serviceable parts inside and removal may void the warranty.
19. An experienced user shall always supervise this professional audio equipment, especially if inexperienced adults or minors are using the equipment.
Explanation of graphic symbols
To prevent electric shock do not remove top or bottom covers. No
user serviceable parts inside. Refer servicing to qualied service
personnel. Français: À prévenir le choc électrique n’enlevez pas les couvercles. Il n’y a pas des parties serviceable à l’intérieur. Tous reparations doit
etre faire par personnel qualié seulment.
To completely disconnect this equipment from the AC mains, disconnect the power supply cord plug from the ac receptacle. The mains plug of the power supply cord shall remain readily operable. Français: Pour démonter complètement l’équipement de l’alimentation générale, démonter le câble d’alimentation de son réceptacle. La prise d’alimentation restera aisément fonctionnelle.
This equipment conforms to the requirements of the EMC Directive 2004/108/EC and the requirements of the Low Voltage Directive 2006/95/EC.
Standards applied: EMC Emission EN55103-1, E3 EMC Immunity EN55103-2, E3, with S/N below 1% at normal operation level. Electrical Safety EN60065, Class I
This equipment is tested and listed according to the U.S. safety standard ANSI/ UL 60065 and Canadian safety standard CSA C22.2 NO. 60065. UL made the tests and they are a Nationally Recognized Testing
Laboratory (NRTL).
The lightning bolt triangle is used to alert the user to the presence of un-insulated “dangerous voltages” within the unit’s chassis that may be
of sufcient magnitude to constitute a
risk of electric shock to humans.
The exclamation point triangle is used to alert the user to presence of important operating and service instructions in the literature accompanying the product.
4
Warning
Operating voltage
To reduce risk of re or electric shock, do not expose this apparatus
to rain or moisture. Français: Pour réduire les risques de blessure ou le choc électrique, n’exposez pas l’appareil à la pluie ou à l’humidité.
Do not expose this system/apparatus to dripping or splashing and
ensure that no objects lled with liquids, such as vases, are placed
on the apparatus. Français: L’appareil ne doit pas être exposé à des egouttements d’eau ou des éclaboussures et de plus qu’aucun objet rempli de liquide tel que des vases ne doit pas être placé sur l’appareil.
This apparatus must be connected to a mains socket outlet with a protective earthing connection. Français: Cet appareil doi t être raccordé á une prise de courant qui est branchée à la terre.
The mains plug is used as a disconnect device and shall remain readily operable. Français: Lorsque la prise du réseau d’alimentation est utilisés comme dispositif de déconnexion, ce dispositif doit demeuré aisément accessible.
Unpacking and visual checks
All E Series ampliers have a universal power supply that operates
on mains from 100 – 240 V at 50 or 60 Hz. The IEC receptacle on the rear panel accepts the supplied IEC cord which terminates in a connector appropriate for the country of sale. When AC power
is connected, the amplier goes into standby (amber indication on power LEDs). It will go on if the power button is pressed (or if signal is supplied to either input or if the GPI is closed). The power LED
shows green for “on” indication.
Grounding
Signal ground is oating via a resistor to chassis, and therefore
grounding is automatic. For safety reasons, never disconnect the
earth (ground) pin on the AC power cord. Use balanced input
connections to avoid hum and interference.
Front panel
Every Lab.gruppen amplier is carefully tested and inspected before
leaving the factory and should arrive in perfect condition. If any damage is discovered, please notify the shipping carrier immediately. Save the packing materials for the carrier’s inspection and for any future shipping.
Installation
Amplier depth is 276 mm (10.9 in) and weight is approximately
4.2 kg (9.2 lbs) depending on model.
Free air ow from front to rear is required for cooling. No doors or covers should be mounted either in front of or behind the ampliers.
Ampliers may be stacked directly on top of each other with no
spacing, though some spacing may enable more convenient installation of rear cabling.
Cooling
The front panel presents the following amplier status indicators:
POWER – Bi-color LED indicates standby (amber) and on (green).
TEMP (temperature) – Flashing amber indicates excessive
temperature in the power supply unit (PSU) or output stage(s).
When temperature exceeds the danger threshold, the LED
shows steady amber and the amplier mutes.
The following indications are per channel:
SIG (input signal present) - Green indication when input signal
exceeds signal present threshold.
LIM (limit) – Illuminates when the amplier limits the signal.
Limitingis engaged when the channel:
• Reaches the selected voltage limit threshold (as determined by model and position of Rail Sensing Limiter (RSL) switch)
• Rail voltage sags below the selected threshold
• Maximum current output reached
• Mains voltage cannot maintain rail voltage
Ensure that there is sufcient space in front of and behind the ampliers to allow for free air ow. Please refer to the full Operation Manual for thermal dissipation value when installing large numbers of ampliers in air
conditioned spaces.
5
Rear panel
Important note on Auto Power On/O – All E Series ampliers include an Auto Power Down/On (APD) scheme. As shipped (factory default), the amplier will go to low power standby mode
when no signal is present for 20 minutes. It will return to power on mode when signal exceeds the signal present threshold. For information on calibrating the signal present threshold, please refer to the Operation Manual.
Power button and indication - When pressed momentarily, toggles power state between standby and on. Indicator shows amber for standby and green for on.
Attenuators - Range is 0 dB to -innity; vertical is -10 dB. Amplier
sensitivity is 4 dBu with attenuator at 0 dB and 14 dBu at -10 dB.
SIG - Illuminates green when input signal above Signal Present
Threshold (SPT). For adjustment of SPT value, please refer to the
full Operation Manual.
Audio inputs
Audio inputs are electronically balanced and use three-pole Phoenix-type connectors. Follow the +, - and Ground labels when making connections.
Loudspeaker outputs
Loudspeaker outputs use detachable block-type connectors. Maximum connector current rating is 41 Arms (exceeding capacity
of the amplier). Cables up to 4 mm
Observe polarity to avoid low frequency cancellation loss.
2
(12 AWG) can be accommodated.
High-pass / Full-range – Selects at or high-pass lter at 50 Hz.
70 V / Lo-Z – Selects settings for the Rail Sensing Limiter (RSL).
The 70 V position should be selected for constant voltage systems and for full rated power into 8 or 16 ohm loads. The Lo-Z position should be selected for full power into 2 or 4 ohm loads, or for limiting maximum output into 8 or 16 ohms. For information on RSL settings for asymmetric loading, please refer to the Operation Manual.
GPIO – GPIO allows use of external relays for power on and off.
See the Operation Manual for information on conguring GPIO.
6
7
A
8
Loading...