1 Introduction
This checklist shall be used to make sure the amplifier is always checked in a proper way
after service has been done. It is important to follow the steps in this check list and check all
points so that the set up of parameters in the amplifier is correct adjusted. When have done all
checks and adjusted the parameters the amplifier will work properly and will have the output
power that it is designed for.
2 Check list class TD
Always clean the amplifier by blowing with compressed air through coolers and fans. Be
careful when blowing where big electrolytic capacitors are placed so that the capacitor doesn’t
get damaged.
If HF- or LF-units have been repaired, always turn the potentiometers fully counter clockwise
on HF-unit before starting the amplifier up (step 1).
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 4 of 10
1) After repair always start the amplifier with current potentiometer (VR3) in mains power
circuit. On is clockwise (cw) and off is counter clockwise (ccw). Check that the switch pulse
is normal. 300V line should increase some volts when relay clicks. Measure step 2 under start
up.
VR3
Measuring points.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 5 of 10
2) Measure that ±16V is correct balanced (tolerance ±0.2V). The voltage shall be balanced
from ±4.5V up to ±16V. If not stop immediately and turn the VR3 ccw again. Start
troubleshooting the amplifier.
Negative side.
Positive side.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 6 of 10
3) Start up of HF-unit. Check HF-wave at 1.3kHz and 13kHz at 8Ω.
Measuring points. Adjustment points. (On=cw and off=ccw).
Potentiometers full ccw. Potentiometers full cw.
Clip 1.3kHz. Clip 13kHz.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 7 of 10
4) Check output signal at clip 8Ω.
Wave measured at 1.3kHz. Wave measured at 13kHz.
5) Check offset on all channels, <30mV.
Check offset without load, <100mV, on all channels in protect. (Shorten temp resistor on each
module, temp warning diode shall light up).
Shorten of temp resistor.
Measuring points.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 8 of 10
6) Check rail voltage.
SP80FB 2x17-2 shall be 136.2V, with a maximum -0 and +2V difference between positive
and negative rail. (Increase voltage = cw, decrease voltage = ccw).
SP80FB 2x32-2 shall be 155V, with a maximum -0 and +2V difference between positive and
negative rail. (Increase voltage = cw, decrease voltage = ccw).
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 9 of 10
7) Check VHF protect on all channels. Turn on gain potentiometer at front to reach clip at
13kHz. Amplifier shall be in VHF protect between 4 – 7 seconds.
8) Check fan control. At idling mode measure approximately 23V and at full speed
approximately 60V.
Short circuit of temp resistor (controlling fan speed) to get full speed of fans.
Measuring points for fan.
THIS DOCUMENT IS CONFIDENTIAL. IT MAY NOT BE REPRODUCED WITHOUT THE WRITTEN PERMISSION OF Lab.gruppen AB
2006 Lab.gruppen AB, Faktorvägen 1, S-434 44 KUNGSBACKA, SWEDEN
Modified: 2008-04-16 Page 10 of 10
9) Check output signal at short circuit on the outputs.
10) Check mains switch for bad contact (click noise).
11) Check gain potentiometers at front. No disturbance at output signal shall be detected
when turning the potentiometer from one end point to the other end point.
12) Check dust filter, change when needed.