Laars LLG125N, LLD125N, LLG125P, LLD125P, LLG175N User Manual

...
/Jandy Products
1999 Products and Parts Catalog
Page 3
Heaters
H E A T E R S
Page 4
/Jandy Products
1999 Products and Parts Catalog
Laars Residential and Commercial Pool Heaters
Laars Lite
The Laars Lite™ is built for dependability and efficiency . At the heart of its efficiency is an ingenious combustion chamber , surrounded by a
Heaters
ceramic fiber that works better than any other insulation material. The Laars Lite™ also offers easy installation, convenient control and a variety of features, including an electronic thermostat, pilot light ignition system, and extended life of the main burners and jacket. The LLD model has a self-cleaning, hot surface ignition which provides quick start-up every time and prevents sooting. No burner tray removal is required (LLD) and the igniter can be easily replaced with one screw . The Laars Lite™ is weather resistant and designed for harsh wind and rain conditions. A vent cap further enhances performance in severe weather conditions. The Laars Lite™ carries an exceptional 5 year limited warranty .
Model # Ignition Thermostat Ctn. Weight 125,000 BTU, Natural Gas, Cast Iron Headers, Heater Only
LLG125N Millivolt Single 148 LLD125N Electronic Dual 148
Laars LLD
125,000 BTU, Propane Gas, Cast Iron Headers, Heater Only
LLG125P Millivolt Single 148 LLD125P Electronic Dual 148
175,000 BTU, Natural Gas, Cast Iron Headers, Heater Only
LLG175N Millivolt Single 175 LLD175N Electronic Dual 175
175,000 BTU, Propane Gas, Cast Iron Headers, Heater Only
LLG175P Millivolt Single 175 LLD175P Electronic Dual 175
250,000 BTU, Natural Gas, Cast Iron Headers, Heater Only
LLG250N Millivolt Single 182 LLD250N Electronic Dual 182
250,000 BTU, Propane Gas, Cast Iron Headers, Heater Only
LLG250P Millivolt Single 182 LLD250P Electronic Dual 182
325,000 BTU, Natural Gas, Cast Iron Headers, Heater Only
LLG325N Millivolt Single 214 LLD325N Electronic Dual 214
325,000 BTU, Propane Gas, Cast Iron Headers, Heater Only
LLG325P Millivolt Single 214 LLD325P Electronic Dual 214
Laars Lite™ Pool & Spa Heater Options
Bronze Headers
A.S.M.E. Certification Salt Water Construction (includes Cupro Nickel
Tubes, Monel Sensor , Bronze Headers and Stainless Steel Fittings)
400,000 BTU, Natural Gas, Cast Iron Headers, Heater Only
LLG400N Millivolt Single 228 LLD400N Electronic Dual 228
400,000 BTU, Propane Gas, Cast Iron Headers, Heater Only
LLG400P Millivolt Single 228 LLD400P Electronic Dual 228
INSTALLATION KITS
10561401-05 INDOOR - DRAFTHOOD KIT 10561501-05 HIGH WIND - VENT CAP KIT
/Jandy Products
1999 Products and Parts Catalog
HEATER SELECTION GUIDE
Page 5
Heaters
Pool Sizing
Determine your pool’s surface area in square feet.
L
R
W
Area = L x W Area = R x R x 3.14 Area = (A + B) x L x .45
Locate in the table below, the surface are equal to or slightly greater than the pool’s surface area, read to the left and select the appropriate heater.
For indoor pool installations, divide the pool’s surface area by three.
T ables are based on a 30°F temperature rise, 3 1/2 MPH wind velocity and elevation of up to 2,000 feet above sea level.
AB
L
LAARS LITE™ SIZING CHART
Spa Sizing
Determine your spa capacity in gallons (surface area x average depth x 7 1/2).
The reference tables list the time required in minutes to raise the temperature of the spa/hot tub by 30°F. Locate in the table below, the spa/hot tub size in gallons. Select the desired time to raise the spa/hot tub temperature 30°F , read to the left and select the appropriate heater.
This guide can be adjusted for other temperature rises. For example, if you desire a 15°F increase in tempera­ture, simply divide the time for 30°F rise by the 15°F increase (30/15=2).
Note: Heat losses and/or heat absorbed by spa walls or other objects will add to heat-up time.
Spa sizing is based on an insulated and covered spa. Always cover your spa or hot tub when not in use to minimize heat loss and evaporation.
POOL HEATER
Model No. 12 5 17 5 25 0 32 5 40 0 T emp. Diff. Maximum Pool Surface Area (Sq. Ft.)
15°F 20°F 25°F 30°F 35°F
Shaded columns indicate sizing with a 0 MPH wind. Example: Rectangular pool, 20 feet x 40 feet, with desired temperature rise of 25°F: 20 x 40 = 800 square foot surface area, the recommended heater is the Laars Lite™ LLG or LLD 250.
667 889 500 667 400 533 333 444 286 381
933 1244
700 933 560 747 467 622 400 533
1333 1778 1000 1333
800 1067
687 889 571 762
1733 231 1 1300 1733 1040 1387
867 1556
743 990
2133 2844 1600 2133 1280 1707 1067 1422
914 1219
Model No. 12 5 17 5 25 0 32 5 40 0 Spa Size (Gal.) Time to Heat Spa 30°F (Minutes)
200 400 600 800
1000
SPA HEATER
30 60
90 120 150
21 43 64 86
107
15 30 45 60 75
12 23 35 46 58
9 19 28 37 47
Example: To heat a 400 gallon spa 30°F in 30 minutes, the recommended heater is the Laars Lite™ LLG or LLD
250.
Page 6
/Jandy Products
LAARS LITE™, Manufactured From 1997
1999 Products and Parts Catalog
20
21
Heaters
57
59
101
82
100
58
62
40
63
37, 38,
39
96
67
99
30
64
74
69
67
26
23
22
20
93
31
19
33,
32
94
70,71
95
72,
73
74
98
10
49
8,9
51-56
97
50
81
11
12
13A
36
27
17
35
15
29
14
28
13
68
41
102
42 47
16
90
86
77,80
78
43
44
46
6
89
76
91
88
75
79
84,85
1
92
87
2
5
3
4
7
12
/Jandy Products
1999 Products and Parts Catalog
Page 7
LAARS LITE™ Pool and Spa Heaters
Key Model ORDER No Description No P ART NO
1 Pilot, Main Burner Assemby, LPG All R0099200 1 Pilot, Main Burner Assembly, NAT All R0099100 2 Pilot Burner, NAT All R0096700 2 Pilot Burner, LPG All R0096800 2A Pilot Shield All R0323300 3 Pilot Generator All W0036901 4 Ceramic Insulator Assembly All R0011600 5 Burner, Main w/Pilot Bracket All 10457500 6 High Voltage Lead Assembly All R0099000 7 Pilot Tubing All R0037000 8 Piezo Lighter Assembly All R0096800 9 Piezo Lighter Knob All R0097000 10 Ignitor - LLD All R0317200
MAIN GAS ASSEMBLY 11 Burner Tray Assy, NAT (Note 1) - LLG 125-400 R0098601-05 11 Burner Tray Assy, LPG (Note 1) - LLG 125-400 R0098701-05 11 Burner Tray Assy, NAT (Note 1) - LLD 125-400 R0316901-05 11 Burner Tray Assy, LPG (Note 1) - LLD 125-400 R0319501-05 12 Burner Tray, Shelf Only 125-400 R0317001-05 13 Gas Valve, NAT - LLG All R0096400 13 Gas Valve, LPG - LLG All R0096900 13 Gas Valve, NAT - LLD All R0317100 13 Gas Valve, LPG - LLD All R0319600 13A Gas Orifice, NAT 13A Gas Orifice, LPG 14 Anti-Rotation Bracket All 10577200 15 Mounting Bracket Assembly All 10419200 16 Burner, Main All L0052300 17 Burner Manifold (Note 2)
ELECTRICAL SYSTEM 18 Temperature Control Assembly - LLG All R0058200 19 Wire Harness All R0058000 20 Plate Assembly All 10456300 21 On-Off Switch All R0099800 22 Temperature Control Label All H0105300 23 Temperature Control Assembly - LLD All R0011700 24 Wire Harness Assembly All 10457800 25 Plate Assembly All 10594600 26 Knob, Single Bar All R0099900
Key Nos. 27- 36 are for both R582 & R117
27 T emperature Sensor All R0011800 28 Protector Sleeve, Bulb All 10444900 29 "O" Ring, Temperature Control Bulb All E0116400 30 Thermostat Knob, Black All R0010700 31 "T emp-Lok" Stop Plate (Not Shown) Al l 10583100 32 Temperature Control Gasket All S0070000 33 Bezel All S0069800 34 Stop Plate Screw All F0033300 35 Retainer Bracket All 10447300 36 Retainer Bracket Screw All F0009100 37 Pressure Switch & Siphon Loop Assembly All R0097600 38 Pressure Switch, 2 PSI All R0013200 38 Pressure Switch, 1 PSI All R0011300 38 Pressure Switch, 1-10 PSI All R0015500 39 Siphon Loop Assembly All R0057800 40 Redundant High-Limit - LLG All R0313900 41 High-Limit Switch Assembly All R0023200 42 High-Limit Switch, 135°F All R0022700 43 High-Limit Switch, 150°F All R0023000 44 High-Limit Switch Retainer Clip All 10418400 45 High-Limit Switch Retainer Boot All S0098900 46 High-Limit Switch Cover All 10418300 47 High-Limit Switch Wire Harness All 10419300 48 Fusible Link Assembly All R0012200 49 Fusible Link Bracket All 10479900 50 Terminal Block All R0097800 51 Ignition Control Assembly - LLD All R0317500 52 Ignition Control - LLD All R0325200 53 Harness Assembly All R0059800 54 Transformer (1 15V-220V/24V) All R0061100 55 Ignition Control Panel All 10451200 56 In-Line Fuse Assembly All 10480000
PILOT GAS SYSTEM - LLG
(Note 1)
(Note 1)
All L0032200 All L0032900
Key Model ORDER No Description No PART NO
VENT SYSTEM 57 T op Enclosure 125-400 R0313201-05 58 T op Filler 125-400 10535201-05 59 Rainshield Kit 125-400 R0318301-05 62 Flue Collector Assembly 125-400 R0316401-05 63 Outdoor Vent Cap 125-400 10561501-05 64 Indoor Drafthood 125-400 10561401-05 65 Flue Transition Plate 125-400 10861901-05 66 Adapter Plate 125-400 10535301-05 67 Clip All 10211000
WATER SYSTEM 68 Inlet/Outlet Header, 2" All R0056400 68 Inlet/Outlet Header, Bronze, 2" All R0016800 69 Return Header All R0058300 69 ReturnHeader, Bronze All R0054600 70 Header Bolt Assembly All R0057000 71 Bolt for Headers, 2 1/2" All F0046100 72 Washer for Headers All F0011100 73 Nut for Headers All F0003100 74 Header Gasket Assembly (Set of 18) All R0050800 75 Flange & Gasket Assembly 76 Flange, 2" All 10573500 77 Flange Gasket, 2" All S0078000 78 Flange Sleeve, 2" All S0078200 79 Flange Bolt All F0031700 80 Flange Gasket, 1 1/2 - 2" All S0078100 81 Grommet for Drain Plug All R0316300 82 Grommet, Slitted All S0071100 83 Hole Plug All S0098700 84 Drain Plug All P0026800 85 Drain Plug Bushing All P0018500 86 Brass Plug, 3/4" All P0027000 87 By-Pass Assembly All R0054900 88 By-Pass Valve Rod All S0074300 89 By-Pass Valve Disc All R0011500 90 By-Pass Valve Control Cap All 10452200 91 By-Pass Valve Spring, Purple 125 S0079900 91 By-Pass Valve Spring, White 175 S0061400 91 By-Pass Valve Spring, Red 250 S0061300 91 By-Pass Valve Spring, Blue 325 S0061200 91 By-Pass Valve Spring, Black 400 S0070100 92 By-Pass Valve Gasket All R0011400 93 Heat Exchanger Tube Assembly 125-400 R0018101-05 94 Heat Exchanger Baffle (8 Required) 125-400 10697401-05 95 Baffle Retainer All S0083900 96 Heat Exchanger Support Clip All 10457000
FIREBOX COMPONENTS
97 Complete Chamber Assembly 125-400 R0316701-05
JACKET COMPONENTS 98 Door with Latch 125-400 R0313401-05 99 Jacket Assembly, Less Top Assembly 125-400 R0316501-05 100 Gap Closure, Inlet/Outlet All 10448200 101 Gap Closure, Return All 10448300 102 Insulation and Retainer All 10462200
OPTIONAL COMPONENTS
Non Combustible Base 125-400 10521701-05
Pressure Relief Valve 3/4" NPT, 75 PSI All R0040400
Touch Up Spray Paint, Light Beige All X0021100
Notes:
1. For altitudes 2,000 Ft above sea level, call factory for orifice size.
2. See Appendix.
3. Two included in assembly.
(Note 3 )
All R0055000
Heaters
Page 8
/Jandy Products
Hi-E2™ Commercial Pool and Spa Heater
Engineered to warm your bottom line, the Hi-E2™ from T eledyne Laars/Jandy Products is the #1 commercial pool and spa heater with a 95% efficiency rating. With unmatched energy efficiency , innovative, trouble-free features and installation flexibility , the Hi-
Heaters
E2™ is the best heater available for indoor , outdoor, new construc­tion or retrofit. The Hi-E2™ also features direct connection to PVC pipe, easy multiple unit stacking for larger facilities, a unique force­air system for reliable performance in extreme weather conditions, dual thermostats for different temperature settings for the pool and spa, and a patented hot surface ignition system. Plus, the Hi-E2™ can reduce your operating costs by 30% or more and is backed by a comprehensive 5-year limited warranty . A leasing plan is avail­able for commercial properties.
Model # Ignition Thermostat Ctn. Weight 220,000 BTU Input, Natural Gas, Bronze Headers
EHE220NC Electronic Dual 2 06
1999 Products and Parts Catalog
220,000 BTU Input, Propane Gas, Bronze Headers
EHE220PC Electronic Dual 206
350,000 BTU Input, Natural Gas, Bronze Headers
EHE350NC Electronic Dual 252
350,000 BTU Input, Propane Gas, Bronze Headers
EHE350PC Electronic Dual 252
HEATER SELECTION GUIDE
Pool Sizing
Determine your pool’s surface area in square feet.
L
R
W
Area = L x W Area = R x R x 3.14 Area = (A + B) x L x .45
Locate in the table below, the surface area equal to or slightly greater than the pool’s surface area, read to the left and select the appropriate heater.
AB
L
Spa Sizing
Determine your spa capacity in gallons (surface area x
average depth x 7 1/2). The reference tables list the time required in minutes
to raise the temperature of the spa/hot tub by 30°F. Locate in the table below, the spa/hot tub size in gallons. Select the desired time to raise the spa/hot tub temperature 30°F , read to the left and select the appropriate heater.
This guide can be adjusted for other temperature rises. For example, if you desire a 15°F increase in tempera­ture, simply divide the time for 30°F rise by the 15°F increase (30/15=2).
For indoor pool installations, divide the pool’s surface area by three.
T ables are based on a 30°F temperature rise, 3 1/2 MPH wind velocity and elevation of up to 2,000 feet above sea level.
Note: Heat losses and/or heat absorbed by spa walls or other objects will add to heat-up time.
Spa sizing is based on an insulated and covered spa. Always cover your spa or hot tub when not in use to minimize heat loss and evaporation.
/Jandy Products
1999 Products and Parts Catalog
Page 9
Hi-E2™ SIZING CHART
POOL HEATER
Model No. 22 0 3 50 T emp. Dif f. Maximum Pool Surface Area (Sq. Ft.)
15°F 20°F 25°F 30°F 35°F
Shaded columns indicate sizing with a 0 MPH wind. Example: Rectangular pool, 20 feet x 40 feet, with desired temperature rise of 25°F: 20 x 40 = 800 square foot surface area, the recom­mended heater is the Hi-E2™ 220.
1333 1778 1000 1333
800 1067
687 889 571 762
2133 2844 1600 2133 1280 1707 1067 1422
914 1219
SPA HEATER
Model No. 22 0 35 0 Spa Size (Gal.) Time to Heat Spa 30°F (Minutes)
200 400 600 800
1000
Example: T o heat a 400 gallon spa 30°F in 30 minutes, the recommended heater is the Hi-E2™ 220.
15 30 45 60 75
9 19 28 37 47
TM
Heaters
For more information: T elephone: Main: (415)382-8220 Order Fax: (800)526-3928
Customer Service: Ext. 245 Warranty/Service: Ext. 260 Literature Requests: Ext. 237
Pool Systems Address: 21 Pimentel Ct., Novato, CA 94949 Mailing Address: P .O. Box 6101, Novato, CA 94948-6101 Web Address: http://www.jandy.com/ International: 480 S. Service Rd. West, Oakville, Ontario, Canada L6K 2H4 (905)844-8233 voice (905)844-2635 fax
Page 10
HI-E2™, Manufactured from 1997
12
Heaters
42
/Jandy Products
1999 Products and Parts Catalog
58
57
41
88
85-86
40
33,34
4
6
31
35
10
36
13
39
56
87
16
49
38
37
55
53,54
52
51
50
14
17
70-72
18-23
15
24-29
43
44
47
67,68
45
46
3
30
9
89
1
77-83
7
63
66
64
11
65
2
74-76
8
5
69
60-62
/Jandy Products
1999 Products and Parts Catalog
Page 11
Hi-E2
Key Model ORDER No. Description No. PART NO:
Limestone Gravel (Condensate Neutralizer) All R0306200 Combustion Air Filter All R0308000
1 Base Panel 220-350 R0301703,05 2 Frame Support Assembly 220-350 R0301503,05 3 Back Panel 220-350 R0300703,05 4 Left Side Panel All R0300500 5 Right Side Panel All R0300800 6 Temperature Control Panel Assembly All R0301603,05 7 Door 220-350 R0301103,05 8 Inlet/Outlet Header Panel All R0301000 9 Right Top Side Panel All R0300900 10 Return Header Panel All R0300600 11 Front Kick Panel 250-350 R0213403,05 12 T op Panel 220-350 R0300103,05
Jacket Hardware Kit Internal Hardware Kit
13 Heat Exchanger Assembly, Complete 220-350 R0303803,05 14 Heat Exchanger Tube Assembly 220-350 R0304103,05 15 Inlet/Outlet Header All R0303900 16 Return Header All R0304000 17 Gasket, Header All R0304300 18 By-Pass Valve Assembly All R0304400 19 Flow Control Cap All 10557400 20 By-Pass Valve Gasket All R0011400 21 By-Pass Valve Spring All R0304500 22 By-Pass Valve Rod All R0304900 23 By-Pass Valve Disk All R0011500 24 Flange & Gasket Assembly, 2" (Set of 2) All R0055000 25 Flange, 2" All 10573500 26 Flange Gasket, 2" All S0078000 27 Flange Sleeve, 2" All S0078200 28 Flange Bolt All F0031700 29 Flange Gasket 1 1/2 - 2" All S0078100 30 Pressure Relief Valve, 75 PSI All R0040400
(Requires field supplied 3/4 NPT x 3" brass nipple) Heat Exchanger Hardware Kit
Inlet/Outlet Header Hardware Kit Return Header Hardware Kit
31 Gas Valve All R0200100 32 Anti-Rotation Bracket (Not Shown) All R0309900 33 Orifice Holder All R0320000 34 Gas Orifice, NAT 220-350 R0309303,05 34 Gas Orifice, LPG 220-350 R0309403,05 35 Combustion Air Filter Assembly All R0306400 36 Combustion Air Filter All R0308000 37 Venturi Inlet 220-350 R0320303,05 38 Venturi O-ring All R0320400 39 Venturi Plenum All R0320500 40 Venturi/Tailpipe Gasket All R0320600 41 Mixing Chamber/Tailpipe Assembly All R0307300 42 Mixing Chamber/Burner Gasket All R0320800 43 Burner Assembly 220-350 R0305903,05 44 Burner/Combustion Chamber Gasket 220-350 R0305803,05 45 Combustion Chamber Assembly 220-350 R0305103,05 46 Refractory Tile Set 220-350 R0305303,05 47 Sight Glass Assembly All R0305400 48 Combustion Chamber Strip Set 220-350 R0213103,05
49 Combustion Chamber/Collector Gasket 220-350 R0305703,05
Venturi Hardware Kit Mixing Chamber Hardware Kit Burner Hardware Kit
MAINTENANCE AND SERVICE COMPONENTS
JACKET ASSEMBLY
(Note 1)
(Note 1)
WA TER SYSTEM
(Note 1)
(Note 1)
(Note 1)
COMBUSTION SYSTEM ASSEMBLY
(Not Shown)
(Note 1)
(Note 1)
(Note 1)
All R0302100 All R0302500
220-350 R0319103,05 All R0319300 All R0319200
All R0322200 All R0322100 220-350 R0319403,05
Key Model ORDER No. Description No. PART NO:
50 Collector 220-350 R0303203,05 51 Blower/Collector Gasket All R0308700 52 Combustion Blower All R0308200 53 Blower/Vent Duct Sleeve All R0308600 54 Blower/ Vent Duct Clamp All R0308800 55 Vent Duct Assembly All R0303100 56 Vent Duct/Heater Top Gasket or
Heater Top/Indoor Vent Collar Gasket All R0309100 57 Heater Top/Outdoor Exhaust Grille Gasket All R0309500 58 Outdoor Exhaust Grille All R0308400 59 Indoor Vent Collar (Not Shown) All R0307900 60 Condensate Trap Assembly All R0303300 61 Limestone Gravel All R0306200 62 Condensate Trap Cover All R0213300
Venturi Hardware Kit
Mixing Chamber Hardware Kit
ELECTRICAL COMPONENTS AND CONTROLS
63 Transformer All R0061100 64 In-Line Fuse Holder Assembly All R0325600 65 Ignition Control All R0202900 66 Wire Harness, Ignition Control All R0302700 67 Igniter Assembly All R0016400 68 Igniter Gasket All R0205300 69 Terminal Block All R0301900 70 High-Limit Switch Set All R0322700 71 High-Limit Switch, 135°F All R0302400 72 High-Limit Switch, 150°F All R0302300 73 High-Limit Switch Wire Harness All R0322600
(Not Shown) 74 Pressure Switch & Syphon Loop Assembly All R0322900 75 Pressure Switch, 2 PSI All R0013200 76 Pressure Switch Siphon Loop All R0307800 77 Temperature Control Assy, Electronic All R0011700 78 T emperature Sensor (Not Shown) All R001 1800 79 Temperature Sensor Gasket All E0116400 80 Temperature Sensor Plastic Sleeve All 10444900 81 T emperature Control Knob All R0010700 82 Pool/Spa Selecter Knob All R0099900 83 "T emp-Lok" Disc All 10583100 84 Temperature Sensor Retainer Clip All 10716701
(Not Shown) 85 Differential Pressure Switch All R0302000 86 Differential Pressure Switch Bracket All R0302200 87 Exhaust Vent Limit Switch All R0309000 88 Burner High Limit Switch All R0319700 89 Combustion Blower Wire Harness All R0308100
OPTIONAL COMPONENTS
Touch Up Spray Paint All X0021 100
High T emperature Silicone Sealant A ll R0322800
Notes:
1. All hardware sets contain all pieces necessary for assembly, including
gaskets. Not shown. Gaskets and hardware are included in all kits
that involve the removal of a gasket as part of the procedure to
replace a part.
EXHAUST ASSEMBL Y
(Note 1)
(Note 1)
All R0322200 All R0322100
Heaters
Page 12
/Jandy Products
Mighty Therm AP Commercial Pool Heaters
Part No. Input Output
AP-500 500,000 BTU/Hr 405,000 BTU/Hr AP-600 600,000 BTU/Hr 486,000 BTU/Hr
Heaters
AP-715 715,000 BTU/Hr 580,000 BTU/Hr AP-850 850,000 BTU/Hr 690,000 BTU/Hr AP-1010 1,010,000 BTU/Hr 820,000 BTU/Hr AP-1200 1,200,000 BTU/Hr 972,000 BTU/Hr AP-1430 1,430,000 BTU/Hr 1,160,000 BTU/Hr AP-1670 1,670,000 BTU/Hr 1,353,000 BTU/Hr AP-1825 1,825,000 BTU/Hr 1,480,000 BTU/Hr AP-2000 2,000,000 BTU/Hr 1,639,000 BTU/Hr * AP-2200 2,200,000 BTU/Hr 1,786,000 BTU/Hr ** AP-2450 2,450,000 BTU/Hr 2,009,000 BTU/Hr * AP-2800 2,800,000 BTU/Hr 2,223,000 BTU/Hr ** AP-3050 3,050,000 BTU/Hr 2,501,000 BTU/Hr * AP-3200 3,200,000 BTU/Hr 2,552,000 BTU/Hr ** AP-3500 3,500,000 BTU/Hr 2,870,000 BTU/Hr * AP-3600 3,600,000 BTU/Hr 2,951,000 BTU/Hr ** AP-4000 4,000,000 BTU/Hr 3,281,000 BTU/Hr ** AP-4050 4,050,000 BTU/Hr 3,321,000 BTU/Hr * AP-4500 4,500,000 BTU/Hr 3,645,000 BTU/Hr ** AP-5000 5,000,000 BTU/Hr 4,100,000 BTU/Hr *
1999 Products and Parts Catalog
* Indoor model only . ** Outdoor Model Only
Options Include:
Indoor / Outdoor- Indoor units include built in draft diverter. Outdoor units do not require a vent cap. Natural Gas / Propane- Natural gas units come standard with electronic ignition (SYS 9). Propane
units come standard with electroinc pilot supervision and standing pilot (SYS 16). Heat Exchanger - Glass/Copper; Glass/Cu-Ni; Bronze/Copper; Bronze/Cu-Ni. Local Code Requirements.
For more information: Telephone: Main: (415)382-8220 Order Fax: (800)526-3928
Customer Service: Ext. 245 Warranty/Service: Ext. 260 Literature Requests: Ext. 237
Pool Systems Address: 21 Pimentel Ct., Novato, CA 94949 Mailing Address: P .O. Box 6101, Novato, CA 94948-6101 Web Address: http://www.jandy.com/ International: 480 S. Service Rd. West, Oakville, Ontario, Canada L6K 2H4 (905)844-8233 voice (905)844-2635 fax
/Jandy Products
1999 Products and Parts Catalog
Telstar™
This above ground pool and spa heater is a uniquely designed, gas fired 50,000 BTU/hr. heater , engineered for energy efficiency and reliability . It has several features, including choice of low gas consumption standing pilot or an electronic ignition, compact design for either free standing or skid mounting application, conveniently located controls, and reliable 24­Volt Control System. Other features include an ef ficient, one-piece cupro-nickle Heat Exchanger/Combustion Chamber Assembly , standard bronze header and water connection flanges, universal flange coupling, internal field wiring compartment, and a built in by-pass for flows up to 80 GPM. The T elstar™ is also listed as a Gas-Fired Spa Heater by Under­writers Laboratories and meets the requirements of U.L. Standard 1563 for Spa Equipment Assemblies. The T elstar™ design is certified by the American Gas Association Laboratories under ANSI Z21. 56 for gas­fired pool heaters.
Model # Ignition Thermostat
Page 13
Heaters
50,000 BTU Input, Natural Gas, Bronze Headers
TGT50AN Millivolt Single
50,000 BTU Input, Propane Gas, Bronze Headers
TGT50AR Millivolt Single
50,000 BTU Input, Natural Gas, Bronze Headers
TGS50AN Electronic Single
For more information: T elephone: Main: (415)382-8220 Order Fax: (800)526-3928
Customer Service: Ext. 245 Warranty/Service: Ext. 260 Literature Requests: Ext. 237
Pool Systems Address: 21 Pimentel Ct., Novato, CA 94949 Mailing Address: P .O. Box 6101, Novato, CA 94948-6101 Web Address: http://www.jandy.com/ International: 480 S. Service Rd. West, Oakville, Ontario, Canada L6K 2H4 (905)844-8233 voice (905)844-2635 fax
Page 14
/Jandy Products
1999 Products and Parts Catalog
TELSTAR™ (SPARK IGNITION) Spa Heaters — TGS-50 -TGS-55 - TRS-55 TELSTAR™ (STANDING PILOT) Spa Heaters — TGT-50 - TGT-55 - TRT-55
Key No.
Heaters
55 Top Plate
(Indoors)
59 Top Plate 74 Top Panel
(Outdoors)
54 Draft Diverter
Hood (Indoors)
73 Cowling 2 Thermocouple 53 Draft Diverter
Assembly
(Indoors)
58 Wind Deflector
Plate (Outdoors)
57 Sleeve, 6"
Diamter
(Outdoors)
56 Sleeve, 4"
Diameter
(Outdoors)
80 Spacer 78, 79 Spacer
Sleeve
72 Cowling, Lower 70 Flue Collector 71 Heater Top 20 Pressure Switch 38 Siphon Loop 46 Nut 78, 79 Spacer 76 Insulation, Flue
Collector T op
70 Flue Collector 45 Sleeve 44 Compression
Fitting
42 Retainer, Flow
Control Rod
39 Rod, Flow
Control
40 By-Pass Valve
Spring
43 Compression
Fitting
41 By-Pass Valve 21 Limit Switch 65 Housing 67 Sight Glass 66 Bezel 68 Lower Wrap 18 Terminal Strip 33 Thermostat
Knob
TGT
TGS
Key No.
69 Top Assembly 22 Limit Switch 27 Retainer Clip 77 Insulation and
Retainer
75 Rating Plate
Bracket
47 Heat Exchanger 3, 4 Pilot Burner 1 Pilot burner 13, 14 Pilot Bracket 9, 10 Orifices 1, 12 Burner Assembly 26 High Voltage
Ignitor Lead Assembly
5 Pilot Tubing 6, 8 Gas Valve 7 Gas Valve 60 Rear Panel 63 Bushing 51 Flange Bolts 50 Plastic Sleeve 48 Flange 49 Packing Collar 52 Drain Plug 34 Plate, Junction
Box
28 Ground Wire 15 Transformer 62 Grommet 37 In/Out Casting 61 Base 35 Sleeve,
Temperature Control
30 “O” Ring 19 Temperature
Control
32 TEMP-LOK™ 24 Indicator Light 17 Toggle Switch 29 Mounting Plate 23 Time Delay
Relay
25 Ignition Control 26 High Voltage
Ignitor Lead Assembly
Loading...