Kyocera PF-500, PF-510 OPTIONS

Service Bulletin
SB Number:
Subject:
SB PF-019
Error code CS1020 due to the damaged CPU of the main board
Creation Date: 15/09/2010
Affected models: PF-500 FS-C5100DN/5200DN/5300DN/5350DN/5400DN
PF-510 FS-C5100DN/5200DN/5300DN/5350DN/5400DN
Phenomenon Error code CS1020 (PF lift motor error) may occur.
Cause The CPU may be damaged due to over-current or over-voltage, when the connection between
the paper feeder and the machine is interrupted.
Solution The diode has been added to the circuit around the CPU to prevent damage to the CPU during
hot-swapping of this connection.
PF-500
PWB PF main with software (viewed from the back)
Position of the added diode.
KMIS Service Department, Kyocera Mita Europe A298 / SB PF-019
Page 1 of 2
Parts
Service Bulletin
No. Old Parts
No.
1 303K801010
3K801010
2 303K901010
3K901010
Classication
Field measure When the above mentioned phenomenon occurs, please replace the main board (PWB PF main
Serial numbers of affected units
Type Serial number
PF-500/510 August 2010 production
The above mentioned changes have been applied to machines produced after the above mentioned production date.
New Parts No.
303K801011 3K801011
303K901011 3K901011
Entire stock rework
assy with software) with the latest type.
Description Q’TY Interchange-
PWB PF MAIN ASSY WITH SOFTWARE
PWB PF MAIN ASSY WITH SOFTWARE
In-eld modication at next visit
SP Applicable unit
ability
Old New Old New
1 1 O O O PF-510
1 1 O O O PF-500
In-eld modication by case
No modication necessary
KMIS Service Department, Kyocera Mita Europe A298 / SB PF-019
Page 2 of 2