When the printed circuit boards on which connectors are mounted were fixed by using screw, the
mated connector could be twisted due to variations in dimensions of such as screw holes. So great
attention should be given not to twist connectors when fixing the boards.
When connectors are mounted off-center of the printed circuit board, or when the printed circuit
boards to be connected are rather large, mating may tilt. In order to avoid tilting, it is recommended
that the printed circuit boards are fixed by the spacer and something that generates a force to retain
the proper mated condition.
押さえ
Retaining Force
スペーサー
Spacer
SERIES 5046 INSTRUCTION MANUAL SPEC No.:205-03-
106-03-004 PAGE 4/9
Page 6
KYOCERA ELCO Corporation
220
3333----2222.... 実装
実装について
について
実装実装
についてについて
(1) 実装の際には、接触部及びテール部に不要な外力が加わり、変形等が生じないようご注意ください。
Please make sure that the product is free from deformity caused by the unnecessary stress to the contacting
Please do not apply flux onto the tail and PC board, when it is soldered manually. Splattered or migrated
flux inside the connector or to the contact points may cause imperfect contact. Also avoid giving any
stress to the product with the soldering iron. It could deform tail or melt insulator.
When you use them as a checker in your production process, please be sure to use our specified plug or
receptacle for the checker. If the connector targeted in this manual is used as a checker, please be informed
that durability may not be high enough or the product to be checked could be damaged excessively.
When you use your original checker, please consult with us beforehand.
チェッカー治具用コネクター型番 (1000 個巻)
Part number of our specified plug connector used as a checker (1000 connectors pa cked in a Tape and Reel)
14 5046 XXX XXX 831
について
についてについて
CHECKER
Distorted Attachment
ねじり
SERIES 5046 INSTRUCTION MANUAL SPEC No.:205-03-
106-03-004 PAGE 6/9
Page 8
KYOCERA ELCO Corporation
220
3333----5555.... 洗浄
洗浄にににについ
洗浄洗浄
貴社工程におきまして、洗浄を実施する場合は、下記条件での洗浄を推奨いたします。
Following cleansing condition should be recommended in case the cleansing is done in your production
process.
<Test Condition for Resistance to Solvent> Solvent :PINE ALPHA ST-100S (ARAKAWA CHEMICAL INDUSTRIES, LTD.) Content:POLYETHYLENE-GLYCOL (solvent classified as ALKYL-ETHER) ― Content Ratio 80%
:NON-ION SYSTEM SURFACE-ACTIVE AGENT ― Content Ratio 15% :PURE WATER ― Content Ratio
<Cleansing Process and Condition>
Process
パインアルファ
ST-100S
Cleansing Washing
超音波揺動 エアーナイフ 温風リフロー
イソプピルアルコール
工場エアー
乾燥
―
05%
Drying
Wiping Drying
System
Detergent
Liquid
Medicine
Temperature
Time
Up and Down Movement
in Hot Liquid
with Ultrasonic Wave
PINE ALPHA
ST-100S
60℃ Normal Temperature
60 Seconds 120 Seconds 60 Seconds 10 Minutes
Up and Down Movement
with Ultrasonic Wave
Isopropyl Alcohol Industrial Air
Air Knife Warm Blow
Normal
Temperature
―
85℃
SERIES 5046 INSTRUCTION MANUAL SPEC No.:205-03-
106-03-004 PAGE 7/9
Page 9
KYOCERA ELCO Corporation
220
3333----6666.... プリント
プリント基板
プリントプリント
PCB AND RECOMMENDED DIMENSIONS OF THE OPENING AREA IN THE METAL MASK
This series of connector is required to be mounted in the high density due to its 0.5mm pitches. The
connectors mounted in the high density need to be controlled adequate amount of solder in order to prevent
failures in the mounting process such as short-circuit caused by solder bridge. For the dimensions of the
metal mask opening, therefore, please refer to our recommended dimensions shown in the attached drawing.
(For detailed dimensions of the printed circuit board, please refer to our product drawings.)
If excessive solder is applied on the retaining metal of the plug connector, especially, it interferes with the
receptacle connector, which leads to incomplete mate of the connectors.
As dimensions shown in the drawings are our recommendations. Please feel free to
contact us if you have any questions and
基板およ
およびびびびメタルマスク
基板基板
およおよ
メタルマスク開口部推奨寸法
メタルマスクメタルマスク
開口部推奨寸法にににについ
開口部推奨寸法開口部推奨寸法
ついてててて
ついつい
////
or concerns about these dimensions.
SERIES 5046 INSTRUCTION MANUAL SPEC No.:205-03-
106-03-004 PAGE 8/9
Page 10
KYOCERA ELCO Corporation
220
Series 5046 : 0.5mm Pitch
Recommended Pad and Stencil Size ((((Signal Contact))))
Plug Receptacle
0.3mm
Pad
2.1mm
0.3mm
0.25mm
0.25mm
2.1mm
Stencil
1.9mm
t=0.15mm
1.9mm
t=0.15mm
SERIES 5046 INSTRUCTION MANUAL SPEC No.:205-03-
106-03-004 PAGE 9/9