PEP Modular Computers GmbH rejects any liability for the correctness
and completeness of this manual as well as its suitability for any particular purpose.
This manual was realized by: TPD/Engineering, PEP Modular Computers GmbH.
The specific product description provided with this product documentation is part of the PEP’s
CPCI Power Supply manual. For further information, in particular regarding general details as
well as safety and warranty statements, refer to the CPCI Power Supply Manual, ID 24139.
2.200W P-Type Power Supply Unit
The main features of the 3U P-type, 120V/230V input, 200W output AC/DC power supply unit
CP3-SVE-P200AC are described in the following table:
Table 1: Distinctive Features of Power Supply Unit CP3-SVE-P200AC
FeatureSpecification
Form Factor
Frontpanel Size
Mechanics
Plug-In Compatibility
Power Supply Connector
Input Voltage
Voltage Switching
Output Power
Output Voltages / Currents
Cooling
Redundant Supply Capability
3U
40.6 * 128.7 mm
19” rack
Yes
Positronic 47-pin connector
V = 85V..264V AC
Frequency: 47Hz..63Hz
Continuous input range
200W with 250 LFM forced-air cooling
V1 = +5V at 40A
V2 = +3.3V at 40A
V3 = +12V at 5.5A
V4 = -12V at 1.5A
5 - 12RTNV1 and V2 RETURN33V2 SENSEV2 REMOTE SENSE
13 - 18V2V2 OUTPUT (+3.3V)34S RTNSENSE RETURN
19RTNV3 RETURN35V1 SHAREV1 CURRENT SHARE
20V3V3 OUTPUT (+12V)36V3 SENSEV3 REMOTE S ENSE
21V4V4 OUTPUT (-12V)37NCNOT CONNECTED
22RTNSIGNAL RETURN38DEG#DEGRADE SIGNAL
23RESERVEDRESERVED39INH#INHIBIT
24RTNV4 RETURN40NCNOT CONNECTED
25NCNOT CONNECTED41V2 SHAREV2 CURRENT SHARE
26RESERVEDRESERVED42FAL#FAIL SIGNAL
27EN#ENABLE43NCNOT CONNECTED
28NCNOT CONNECTED44V3 SHAREV3 CURRENT SHARE
29NCNOT CONNECTED45CGNDCHASSIS GROUND
30V1SENSEV1 REMOTE SENSE46ACNAC INPUT NEUTRAL
31NCNOT CONNECTED47ACLAC INPUT LINE
2.3Installation
Thanks to its plug-in compatibility this P-type power supply unit allows for an easy installation,
by which the power supply unit’s male Positronic 47-pin power connector is inserted into the
backplane’s mating female connector without the need of any intermediate adaptation.
Warning!
If this type of power supply is removed for any reason from an operating system, do not reinstall immediately. Wait 1 to 2 minutes before
reinstalling. Failure to comply with this may result in an Output Failure
indication on the power supply. This is due to an internal protection
feature of the power supply which requires ti me to cool down before
the power supply is put back into operation.
Input Voltage - ACContinuous input range.85264VAC
Input Frequency4763Hz
Hold-up Time20ms
Input ProtectionNon-user serviceable, internally-located input line fuse.
Inrush Surge CurrentInternally limited by thermistor and electronic switch.30A
Operating FrequencySwitching frequency of main output transformer.125145kHz
With 250 LFM forced-air cooling At 100% load:
Derate linearly above 50°C by 2.5% per °C. At 50%
load:
050
- 40+ 85°C
10k
40k
70
ASL Ft.
°C
Warning!
Adequate thermal cooling of the power supply must be ensured.
Therefore do not obstruct or hinder cooling air circulation or heat conduction within the power supply or surrounding equipment.
Failure to comply with this warning may result in damage to yo ur
equipment.