Kontron CP3-SVE-M76AC User Manual

Page 1
CPCI
Power Supply
Manual
PRODUCT DOCUMENTATION
Reference ID: 24139 PD13 Rev. 01
July 18, 2007
PD13
CP3-SVE-M76AC
Page 2
PD13: CP3-SVE-M76AC CPCI Power Supply

Revision History

Publication Title: CPCI Power Supply Manual:
Product Documentation: CP3-SVE-M76AC
Doc. ID: 24139 PD13
Rev. Brief Description of Changes Date of Issue
01 Initial issue Jul. 18, 2007

Imprint

Kontron Modular Computers GmbH may be contacted via the following:
MAILING ADDRESS TELEPHONE AND E-MAIL
Kontron Modular Computers GmbH +49 (0) 800-SALESKONTRON Sudetenstraße 7 sales@kontron.com D - 87600 Kaufbeuren Germany
For information about other Kontron products, please visit our Internet web site: www.kontron.com

Disclaimer

Copyright © 2007 Kontron AG. All rights reserved. All data is for information purposes only and not guaranteed for legal purposes. Information has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Kontron and the Kontron logo and all other trademarks or registered trademarks are the property of their respective own­ers and are recognized. Specifications are subject to change without notice.
Page 3
CPCI Power Supply PD13: CP3-SVE-M76AC

1. Introduction

The specific product description provided with this product documentation is p art of the Kontron CPCI Power Supply manual. For further information, in particular regarding general details as well as safety and warranty statements, refer to the CPCI Power Supply Manual, ID 24139. This power supply is designed for use with standard CPCI systems as well integration in elec­tronic or electrical enclosures (e.g. Kontron’s CP-Pocket, 19” racks, etc.).

2. 75W M-Type Power Supply Unit

The main features of the 3U M-type, 75 W output AC power supply unit CP3-SVE-M76AC are described in the following table:
Table 1: Distinctive Features of Power Supply Unit CP3-SVE-M76AC
FEATURE SPECIFICATION
FORM FACTOR
FRONT PANEL SIZE
HEIGHT OF POWER SUPPLY UNIT
WIDTH OF POWER SUPPLY UNIT DEPTH OF POWER SUPPLY UNIT
MECHANICS
PLUG-IN COMPATIBILITY
POWER SUPPLY CONNECTOR
INPUT VOLTAGE
INPUT FREQUENCY
OUTPUT VOLTAGES / CURRENTS
3U
40.3 mm x 128.4 mm 3 U (128 mm) 8 HP (40 mm)
171.9 mm (without connector and handle) 19” rack Yes DIN M24/8 connector 115/230 VAC, automatic switching 47 … 63 Hz V1 = +5.1 V, max. 8.0 A
V
= +3.3 V, max. 8.0 A
2
= +12 V, max. 0.15 A
V
3
OUTPUT POWER
TOTAL MINIMUM OUTPUT LOAD
COOLING
REDUNDANT SUPPLY CAPABILITY
STAT US INDICATION
SPECIAL FEATURE(S)
75 W 0 W Forced air cooling: 0.5 m/s recommended — Separate LEDs for V1 and V
None
2
RID 24139 PD13, Rev. 01 Page 3
Page 4
PD13: CP3-SVE-M76AC CPCI Power Supply

2.1 Mechanical Specifications

Figure 1: View of Power Supply Unit CP3-SVE-M76AC
Page 5
CPCI Power Supply PD13: CP3-SVE-M76AC

2.2 Power Supply Connectors

2.2.1 DIN M24/8 Power Supply Connector

Figure 2: Orientation of the DIN M24/8 Power Supply Connector
The AC power input is via the front
V
panel connector. The voltages from the power supply unit
to the backplane are connected via a 32-pole DIN 24/8 male power supply connector.
For the pinouts of the DIN M24/8 power supply connector please refer to the following table.
... V3 output
1
Table 2: DIN M24/8 Connector Pinouts
PIN FUNCTION PIN FUNCTION
2 NC B.17 +3.3VL 5 NC B.18 +3.3VL
11 PE B.19 +12VL A.13 NC B.20 NC A.14 NC C.13 NC A.15 NC C.14 NC A.16 0VF C.15 NC A.17 +5VF C.16 +3.3VL A.18 +3.3VL C.17 +3.3VL A.19 +12VL C.18 +3.3VL A.20 NC C.19 +12VL B.13 +3.3VL C.20 NC B.14 +3.3VL 22 +5VL B.15 +3.3VL 25 OVL B.16 +3.3VL
RID 24139 PD13, Rev. 01 Page 5
Page 6
PD13: CP3-SVE-M76AC CPCI Power Supply
1
2
3
1 2
3

2.2.2 Front Panel AC Input Power Connector

This connector is available for applications requiring input power from the front of the chassis. This is a Phoenix, 3-contact connector (GMSTB 2,5/ 3-GF-7,62). This connector is not de­signed for “hot-plugging”. The following figure and table provide pinout information.
Figure 3: Front Panel AC Input Power Connector
Table 4-3: Pinout of Front Panel Connector
PIN SIGNAL
1L 2N 3PE

2.2.3 Line Input Connector

This connector is the complementary connector for the application side for connecting to this power supply and is delivered with the power supply. This is a Phoenix, 3-contact plug type connector (GMSTB 2,5/ 3-STF-7,62). The following figure and table provide pinout information.
Figure 4: Line Input Connector
Table 4-4: Pinout of Line Input Connector
PIN SIGNAL
1L 2N 3PE
Page 7
CPCI Power Supply PD13: CP3-SVE-M76AC

2.3 Installation

Thanks to its plug-in compatibility this DIN M-type power supply unit allows for an easy instal­lation, by which the power supply unit’s male DIN M24/8 power connector is inserted into the backplane’s mating female connector without the need of any intermediate adaptation.

2.4 Electrical Specifications

Input
Input voltage ranges 115/230 VAC, 50/60 Hz, automatic switching
ranges: 90 … 138 VAC or 184 ... 264 VAC Efficiency > 80 % (typical) Inrush current limitation
25 A
35 A
peak peak
cold warm
Fuse 3.15 AT (internal, not user serviceable) Hold-up time 115 V: > 30 ms at 100 % load
230 V: > 35 ms at 100 % load
Output
Output power V
(5.1 V) voltage: 5.1 V, +5/-3% (including ripple and noise)
1
current: min 0.0 A; nominal 8.0 A; peak 12 A for 100 ms Output power V
(3.3 V) voltage: 3.3 V, +5/-3% (including ripple and noise)
2
current: min 0.0 A; nominal 8.0 A; peak 12 A for 100 ms Output power V
(12 V) voltage: 12 V, +8/-7% (including ripple and noise)
3
current: min 0.0 A; nominal 0.15 A; peak 0.2 A Ripple V
, V2: < 50 mV
1
V3: < 200 mV
pp
pp
Total output loads min 0 W; max 75 W for all outputs Status indication green LEDs for V
, V
1
2
Rise-delay time < 1 s at 115/230 VAC Start-up time 15 ms
Regulation
Line regulation < 0.2 % for V Load regulation < 0.5 % for V
, V2 at a load of 8.0 A each
1
, V
1
2
RID 24139 PD13, Rev. 01 Page 7
Page 8
PD13: CP3-SVE-M76AC CPCI Power Supply
+5V
+3.3V
voltage: 1V / div.
time: 0.5 ms / div.
Output Power Diagrams Figure 5: Signal when Switched On
Protection and Control
Overvoltage protection Overload protection Current limitation: >150 % I
Over temperature protection Switches off if inside temperature becomes too high,
Environment
Operating ambient temperature 0 °C to + 55 °C (without derating)
Derating 2.0 % / °K between 55 °C and 70 °C Climatic humidity 93 % RH at 40 °C, non-condensing
Recommended airflow 0.5 m/s
125 %
Thermal shutdown with auto-restart for V Output permanent short-circuit proof
restart with hysteresis
0 °C to + 70 °C (with derating)
(acc. to IEC 60068-2-78)
± 5 % for V1, V2
Rated
for V1, V
2
3
Page 9
CPCI Power Supply PD13: CP3-SVE-M76AC
EMC
Interference suppression/immunity EN 61000-6-2 Interference emission EN 55022 Class A: interference transmission depends
on assembly
Safety
IEC 60950-1 UL60950-1
Warning!
Adequate thermal cooling of the power supply must be ensured. Therefore do not obstruct or hinder cooling air circulation or heat con­duction within the power supply or surrounding equipment.