Kontron CP3-SVE-M180AC User Manual

Page 1
CPCI
Power Supply
Manual
PRODUCT DOCUMENTATION
PD04
CP3-SVE-M180AC
Reference ID: 24139 PD04
Revision: 01
The product described in this manual is in compliance with all applied CE standards.
Page 2
PD04: CP3-SVE-M180AC CPCI Power Supply

Revision History

CPCI Power Supply Manual:
Manual/Product Title:
Reference ID: 24139 PD04
Product Documentation: CP3-SVE-M180AC
Rev.
Index
01 Initial Issue Feb. 01, 2002
Brief Description of Changes Date of Issue

Imprint

Copyright © 2002 PEP Modular Computers GmbH. All rights reserved. This manual may not be copied, photocopied, reproduced, translated or converted to any electronic or machine­readable form in whole or in part without prior written approval of PEP Modular Computers GmbH.
DISCLAIMER:
PEP Modular Computers GmbH rejects any liability for the correctness and completeness of this manual as well as its suitability for any partic­ular purpose.
This manual was realized by: TPD/Engineering, PEP Modular Computers GmbH.
Page 2 © 2002 PEP Modular Computers GmbH RID 24139 PD04, Rev. 01
Page 3
CPCI Power Supply PD04: CP3-SVE-M180AC

1. Introduction

The specific product description provided with this product documentation is part of the PEP’s CPCI Power Supply manual. For further information, in particular regarding general details as well as safety and warranty statements, refer to the CPCI Power Supply Manual, ID 24139.

2. 180W M-Type Power Supply Unit

The main features of the 3U M-type, 120V/230V input, 180W output AC/DC power supply unit CP3-SVE-M180AC are described in the following table:
Table 1: Distinctive Features of Power Supply Unit CP3-SVE-M180AC
Feature Specification
Form Factor
Frontpanel Size
Mechanics
Plug-In Compatibility
Power Supply Connector
Input Voltage
Voltage Switching
Output Power
Output Voltages/Currents
Cooling
3U
60.96* 133.35 mm 19” rack Yes DIN M24/8 connector VUS = 99V..138V AC
V
= 187V..264V AC
EU
Frequency: 50Hz..60Hz Autoranging 180W Vo1 = +3.3V at 14A
= +5.1V at 20A
V
o2
V
= +12V at 2A
o3
= -12V at 1A
V
o4
Free convection
Redundant Supply Capability
Status Indication
Special Feature(s)
RID 24139 PD04, Rev. 01 © 2002 PEP Modular Computers GmbH Page 3
— Separate LEDs for Vo1..V
o4
Page 4
PD04: CP3-SVE-M180AC CPCI Power Supply

2.1 Mechanical Specifications

Figure 1: View of Power Supply Unit CP3-SVE-M180AC
60.5 mm (12HP)
100 mm (3U)
171.93 mm
Page 4 © 2002 PEP Modular Computers GmbH RID 24139 PD04, Rev. 01
Page 5
CPCI Power Supply PD04: CP3-SVE-M180AC

2.2 Power Supply Connector

Figure 2: Orientation of the DIN M24/8 Power Supply Connector
Table 2: DIN M24/8 Connector Pinouts
Pin Function Pin Function
2
L1 (live connection)
The V
and V
EU
input voltages to
US
the power supply unit and the Vo1...Vo4 output voltages from the power supply unit to the backplane are connected via a 32-pole DIN 24/8 male power supply connector.
For the pinouts of the DIN M24/8 power supply connector please refer to the following table.
B.17
+3.3VL
5
11 A.13 A.14 A.15 A.16 A.17 A.18 A.19 A.20 B.13 B.14 B.15 B.16
N/C = Not connected.
N (neutral) PE (earth protection) INT (internally connected) N/C INT (internally connected) OVF +5VF +3.3VL +12VL
-12VL +3.3VL +3.3VL +3.3VL +3.3VL
B.18 B.19 B.20 C.13 C.14 C.15 C.16 C.17 C.18 C.19 C.20
22 25
+3.3VL +12VL
-12VL N/C DEG INT (internally connected) +3.3VL +3.3VL +3.3VL +12VL
-12VL +5VL OVL
RID 24139 PD04, Rev. 01 © 2002 PEP Modular Computers GmbH Page 5
Page 6
PD04: CP3-SVE-M180AC CPCI Power Supply

2.3 Installation

Thanks to its plug-in compatibility this DIN M-type power supply unit allows for an easy instal­lation, by which the power supply unit’s male DIN M24/8 power connector is inserted into the backplane’s mating female connector without the need of any intermediate adaptation.
Warning!
To ensure a safe 5 V operation of your equipment it is necessary th at
on the backplane 5VL is connected to 5VF and 0VL to 0VF. PEP sys-
tems provide this configuration by default.
The maximum voltage compensation is 0.25V per line.

2.4 Electrical Specifications

Input
V
Input voltage ranges
= 187V..264V AC
EU
= 99V..138V AC
V
US
Frequency: 50Hz..60Hz Voltage switching Autoranging Efficiency Typ. 82% Input current limitation
Typ. 15A
Typ. 20A
(cold state)
peak
(hot state)
peak
Fuse 6.3 AT
Output
Adjustment range V
o1
, V
o2
Status indication Green LED’s for V
± 5%
, Vo2, Vo3, V
o1
Ripple Vo1, Vo2 < 50mVpp,
, Vo4 < 30mV
V
o3
pp
Noise voltage Typ. 50mVpp (band width 20MHz)
o4
Temperature coefficient 0.025% / K Switch on / switch off performance No overshooting of V
(soft-start)
o
Rise-delay time < 0.5s Run-up time ≤ 50ms
Page 6 © 2002 PEP Modular Computers GmbH RID 24139 PD04, Rev. 01
Page 7
CPCI Power Supply PD04: CP3-SVE-M180AC
Figure 3: Output Power Diagrams
Regulation
Line regulation < 0.2% for V
< 0.5% for Vo3, V
Load regulation < 0.1% for V
< 0.1% for V < 5.0% for Vo3, V
o1
o1 o2
, V
o2 o4
o4
Response time < 0.5ms at Io 20..80%
Protection and Control
Overvoltage protection 125% ± 5% for V
125% ± 10% for Vo3, V
o1
, V
o2
o4
Automatic repetition
Current limitation Typ. 110% of I
Typ. 200% of I Typ. 140% of I
Rated Rated Rated
for Vo1, V
for V
o3
for V
o4
o2
Effective for all outputs, outputs short-circuit proof, max. 10 min.
Overtemperature protection Switches off when inside temperature
becomes too high, switches on again with
hysteresis Mains buffering > 20ms at 100% load Signal DEG (Derate) Open-collector, I
Low during start-up of V
high 100-200ms after start-up of V
low 5ms before break-down of V
max
= 48mA
,
o
,
o o
(mains failure/switch-off) Permitted switch off/on cycle time ≥ 2s
RID 24139 PD04, Rev. 01 © 2002 PEP Modular Computers GmbH Page 7
Page 8
PD04: CP3-SVE-M180AC CPCI Power Supply
EMC
Interference suppression/immunity EN 50082-2: 1992
EN 61000-4-2:Intensity 4 EN 61000-4-3:Noise level 10V/m EN 61000-4-4:Intensity 4 EN 61000-4-5:Intensity 3 EN 61000-4-11 VDE (with switch-off and re-start)
Interference emission EN 50081-1:1992
EN 55011/EN 55022: ClassB, interference transmission depends on assembly
Safety
EN 60950/VDE 0805 Safety Class I, VDE 0100 CSA NRTL/C / UL 1950 / CSA 22.2-950
Operating Data
Temperature range 0°C..+70°C with free convection Temperature derating 2% / K at +50°C (see diagram)
Warning!
Adequate thermal cooling of the power supply must be ensured. Therefore do not obstruct or hinder cooling air circulation or heat con­duction within the power supply or surrounding equipment.
Failure to comply with this warning may result in damage to yo ur equipment.
Page 8 © 2002 PEP Modular Computers GmbH RID 24139 PD04, Rev. 01
Loading...