Konica Minolta F-2900 User Manual

9224-2885-11 H-A909
E
INSTRUCTION MANUAL
Thank you for purchasing the Minolta Dimâge Scan Elite.The Dimâge Scan Elite F-2900 is a dual format film scanner capable of scanning 35mm and with the optional AD-10 APS Adapter, Advanced Photo System film.
This manual has been designed to help you understand the operation of your scanner. Please read this manual thoroughly to realise all the benefits of your scanner.
The instructions in this manual assume you have a working knowledge of the operating system for your computer (Macintosh OS, Windows 95, Windows 98, or Windows NT) and its conventions. Familiarity with the mouse and standard operating system menus and commands is necessary before operating the driver software for the Dimâge Scan Elite.
This manual does not instruct in the:
• basic use of personal computers.
• use of Windows 95, Windows 98, Windows NT, or Macintosh OS.
• use of Adobe Photoshop, Paint Shop Pro, or Corel Draw.
The examples in this manual use Windows 95.The appearance of some screens may differ from the examples when using Windows 98, Windows NT, or the Macintosh operating system.
This mark certifies that this product meets the requirements of the EU (European Union) concerning interference causing equipment regulations. CE stands for Conformité Européenne.
This Class B digital apparatus complies with Canadian ICES-0003. Cet appareil numérique de la classe B est comforme à la norm NMB-003 du Canada.
• Changes or modifications not approved by the party responsible for compliance could void the user’s authority to operate the equipment.
• This manual may not be copied in part or whole without pr ior written per mission from Minolta Co., Ltd. ©1999 Minolta Co., Ltd.
• Every necessar y caution has been taken to ensure the accuracy of this instruction manual. Please contact us if you have any questions, find any errors, or notice missing information.
• Minolta is not responsible for loss, damage, or other results occurring during the operation of this product.
Tested by the Minolta Corporation 101 Williams Drive Ramsey, New Jersey 07446 USA
This device complies with Part 15 of the FCC Rules.Operation is subject to the following conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To meet FCC regulations, the SCSI cables used with this scanner must be equipped with ferrite cores.
Microsoft, Windows®, Windows 95®, Windows 98®, and Windows NT®are registered trademarks of the Microsoft Corporation. Macintosh™, Apple®, and Power Macintosh®are registered trademarks of Apple Computer, Inc. Adobe®and Photoshop™ are registered trademar ks of Adobe Systems Incor porated. Corel Draw™ is a trademark of the Corel Cor poration. Paint Shop Pro is the copyright of Met’s Corporation. Other corporate and product names are the trademarks and registered trademarks of their respective companies.
1
FOR PROPER AND SAFE USE
Please read and understand each caution before using this product.
To avoid fire or electric shock:
• Use only within the voltage range specified on the back of unit.
• Do not expose this unit to liquids.
• Do not insert metal objects into this unit.
• Do not touch the cord or plug if your hands are wet.
• Unplug this unit when it is not in use.
Improper use of the power cord may result in fire or electric shock.
• Insert the plug securely into an electrical outlet.
• Do not pull on the cord. Grasp the plug when removing the power cord from an outlet.
• Do not scratch, twist, modify, heat, or place a heavy object on the power cord.
• Do not connect the ground to a gas pipe, telephone ground, or a water pipe.Improper grounding can result in electric shock.
This product must have sufficient ventilation while in use. Blocked ventilation ducts may cause the unit to overheat, increasing the risk of fire.
• Do not use or store this product in dusty or very humid areas.
• This product should be operated in the upright position only. Do not stack any objects on this product.
If there is smoke, a strange smell, or any other unusual conditions, shut down and unplug the unit, then contact a Minolta Ser vice Facility.
CAUTION
Unexpected damage may occur if this unit is left unattended near young children.
Do not attempt to disassemble this product. It contains high-voltage circuits.Take the product to a Minolta Service facility for repairs.
WARNING
2
SYSTEM REQUIREMENTS – PC AT
CPU:
Operating System:
Memory:
Monitor:
Other:
Windows 95 (incl. OSR2), Windows 98, or Windows NT 4.0.
A minimum of 32 MB RAM.
XGA (1024 x 768) or better.VGA (640 x 480) can be used.
SCSI Board: The following Adaptec SCSI boards are recommended for this
device:
AVA-1505AE AVA-2902E AHA-1510B AHA-1520B AHA-1540CP AHA-2940 AHA-2940J AHA-2940U AHA-2940N AHA-2940AU AHA-2940W AHA-2940UW AHA-2910B AHA-2910C AHA-2920C
• The AHA-2940N SCSI board has been tested and approved for use on NEC PC-9821 series machines.
• Do not use AVA-1505AE, AHA-1520B, and AHA-1540CP SCSI boards with NEC PC98NX Series machines.
• Support will not be provided for malfunctions or problems caused by the use of untested SCSI boards.
• Depending upon the SCSI board an optional adaptor may be required.
Hard Disk Space: 90 MB of available hard disk space.
IBM PC/AT compatible with An Intel Pentium or later processor or better. An Intel Pentium or later when Windows NT 4.0 is installed.
• Support cannot be provided for custom or home built machines.
TWAIN driver is compatible with Photoshop ver. 3.05, 4.0.1, and
5.0.2. Photoshop LE Ver. 5.0 Paint Shop Pro 5.0E, Corel Photo Paint 8.
SYSTEM REQUIREMENTS – MACINTOSH
3
Power PC
A minimum of 8 MB application RAM in addition to the requirements for the Mac OS and Adobe Photoshop™
13 inch monitor capable of displaying 32,000 colors.
CPU:
Operating System:
Memory:
Monitor:
Other:
Hard Disk Space: 90 MB of available hard disk space.
Mac OS 7.5 to 8.6
Standard SCSI board (SCSI expeansion card inserted in PCI/NuBus must not be used)
New Power Macintosh G3 series (Blue and White) use:
Adaptec PowerDomain 2940UW, PowreDomain 1940U2W, PowerDomain 2930U or SCSI Card 2906.
SCSI board:
Plug-in is compatible with Photoshop ver. 3.05, ver.4.01 or ver.5.02. Photoshop LE Ver. 5.0. ColorSync profile (DS Elite profile) is included. Turn off Virtual Memor y and the Moder n Memor y Manager.
4
PACKAGE CONTENTS
1. Minolta Dimâge Scan Elite
2. 35mm Slide and Negative holders
3. SCSI cable SC-11
4. AC power cord
5. DS_Elite driver software and manuals CD ROM
6. Quick Reference Guide
7. Warranty card
8. Photoshop LE CD ROM
The following contents should be included in this package.
Software Registration
Please register this software before using it… Once registered, you will receive technical support, software upgrade and product information. Complete and return the enclosed Product & Software Registration form after detaching it form the Warranty. No postage is necessary.
• The information you provide is confidential and will only be used by Minolta Customer Service and Product Research & Development.
5
TABLE OF CONTENTS
FOR PROPER AND SAFE USE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SYSTEM REQUIREMENTS PC/AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
SYSTEM REQUIREMENTS Macintosh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
PACKAGE CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
TABLE OF CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
NAMES OF PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
SCANNER SETUP
Setting the SCSI ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Connecting the Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Installing the Software PC/AT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Installing the Software Macintosh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
STANDARD OPERATION
Launching the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Main Window Command Window - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20
Setting the Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Loading the Film Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Inserting the Film Holder into the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Setting the Film Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Prescan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Auto-Exposure Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
AE Area Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
Orienting the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Image Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Image Correction - Tone Curves/Histogram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Image Correction - Brightness/Contrast/Color Balance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Image Correction - Hue/Saturation/Lightness . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Image Correction - Var iation Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Image Correction - Snapshot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Image Correction - Full-Screen View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Image Correction Job - Job Save/Job Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Final Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
SCANNING APS FILM
Launch Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Specify Film Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Preferences - APS Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
APS Adapter - Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Loading the APS Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Inserting the APS Adapter into the Scanner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Index Scan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Index tab – Names of Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Preview and Image Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Scanning the Image . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Removing the APS Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
APPENDIX
Color Matching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Scan Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Creating/Deleting Scan Job Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .73
Scan Job File List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .78
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .81
User Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .82
6
SCANNER – NAMES OF PARTS
1. Indicator lamp
2. Film slot
3. Film door
4. Power switch
5. SCSI por t - DB25
6. Terminator power switch
7. SCSI ID switches
8. SCSI por t - SCSI-1
9. AC socket
SCANNER SETUP
8
Setting the SCSI ID
Tur n off the computer and all the devices in the SCSI chain before changing SCSI IDs, connecting, or disconnecting SCSI cables.Hardware damage may occur if this precaution is not followed.
SETTING THE SCSI ID
A SCSI ID is a unique address you assign to each SCSI device connected to your computer.The SCSI ID range of your computer is from 0 to 7, however some ID's are already occupied.
1. Turn off the computer and all connected SCSI devices.
SCSI ID Dip Switch Settings
3. Using a pointed object, set the switches to an unused SCSI ID.
• The Dimâge Scan Elite’s SCSI ID is factory preset to 5. If 5 is not
occupied, there is no need to change the SCSI ID.
• Two operating SCSI devices in the same SCSI chain cannot share a
SCSI ID.
2. Determine which SCSI IDs are not being used.
IBM PC/AT
Macintosh
Occupied SCSI ID
7 - SCSI host adapter 0 - internal hard drive*
3 - internal CD ROM drive** 7 - operating system
* IDE Macintosh systems do not use SCSI ID 0 for the hard drive. ** SCSI ID 3 is available on the external bus on Macintosh systems with a dual bus.
9
CONNECTING THE HARDW ARE
2. Connect one end of the SCSI cable to either SCSI port on the back of the scanner
• Either SCSI port can be used for other configurations, there is no
dedicated in or out port.
1. Place the scanner on a level surface.
3. Connect the other end of the SCSI cable to the SCSI port on the computer or the last device in the SCSI chain.
Continued on the following page.
Connecting the SCSI Cable
This scanner has been packaged with the SCSI cable SC-11 (DB25-to-SCSI-1).See your dealer if you require a different SCSI cable.
• To meet FCC regulations, the SCSI cables used with this scanner must be equipped with ferrite cores.
BEFORE Y OU BEGIN… TURN THE COMPUTER AND ALL CONNECTED DEVICES OFF.
10
CONNECTING THE HARDW ARE
4. Plug the SCSI cable from the next device into the open port on the back of the scanner.
If there are other devices in your SCSI chain…
5. Plug the power cord into the scanner’s AC socket, then plug it into a grounded outlet.
This decive is to be used with a power source within the
voltage as specified on
the back of unit.
11
Ter minating the SCSI chain
helps to suppress electronic
noise in the SCSI chain.
Not terminating the SCSI chain
can cause slowdowns, data
errors, crashes, and other
unpredictable errors.
5. Plug the power cord into the scanner’s AC
socket, then plug it into a grounded outlet.
4. Turn the terminator power switch (switch 4) to ON.
• An external ter minator is not necessar y with
this scanner.
If the Dimâge Scan Elite is the last or only device in your SCSI chain…
CONNECTING THE HARDW ARE
This decive is to be
used with a power
source within the
voltage as specified on
the back of unit.
• The Device Wizard dialog box will appear.
INSTALLING THE SOFTWARE – PC/AT
12
WINDOWS 95/ WINDOWS 98 WINDOWS NT
1. Turn on the scanner, then turn on the PC.
2. Start the Windows operating system.
This step varies with your specific operating software...
Windows 95
Windows 95 Release 2 (OSR2) and Windows 98
• The New Hardware Found dialog box will appear.
3. Click on Cancel.
• This dialog box may appear several times. Repeat step 3 until the dialog box no longer appears.
3. Click on Next until the Unknown Device window appears…
…then click on Finish.
• This dialog box may appear several times.
Repeat step 3 until the dialog box no longer appears.
Windows NT
3. Select Start > Settings > Control Panel, then double-click on the SCSI Adapters icon. Confirm that Minolta #2885 appears as a connected device for your SCSI board.
• If Minolta #2885 does not appear, turn the system off and check all the connections. Repeat the
procedure.
4. Insert the Dimâg e Scan Elite CD-ROM into the CD­ROM drive.
Dimâge Scan Elite for Windows Setup installs the Twain and Twain_32 driver software into the drive and folder you select.
• The appearance and/or wording of some dialog boxes may vary depending on the version of Windows running
on your machine.
• These installation instr uctions assume drive D is the CD-ROM drive.
then click on Next.
9. Click on Browse to select another destination directory…
• An install director y and path can also be entered
directly into the install path list box.
8. After reading the agreement, click on Y
es.
• If you do not agree to the conditions stated in the
End-User License Agreement, click on No and the software will not be installed.
6. Select D:\DRIVER\ENGLISH\Setup.exe from the Open drop-down list, then click on O
K.
• If your CD-ROM drive is not the D drive, replace
the D with the appropriate designation for your CD-ROM drive.
INSTALLING THE SOFTWARE – PC/AT
13
5. Select Run form the Start menu.
The Run dialog box will appear.
The Software License Agreement will appear.
The Choose Destination Location dialog box will appear.
Continued on the following page.
7. Click on Next.
The installer flash will appear.
13. Click on Yes.
12. Click on Close.
11. Click on Next.
• Setup will begin.
INSTALLING THE SOFTWARE – PC/AT
14
10. Choose either Typical or TWAIN Files install, then click on N
ext.
The Setup Type dialog box will appear.
The Select Program Folder dialog box will appear.
The Setup Successful dialog box will appear.
The following dialog box will appear.
INSTALLING THE SOFTWARE – MACINTOSH
15
1. Turn on the Dimâge Scan Elite, then turn on your Macintosh.
2. Quit any open applications.
3. Insert the Dimâg e Scan Elite CD-ROM into the CD-ROM drive.
will appear on the desktop.
4. Double-click on .
• The dr iver folders will appear.
7. Click on .
8. Click on .
• If you do not agree to the conditions stated in the End-User License Agreement, click on Decline and the software will not be installed.
The End-User License Agreement will appear.
The installer’s start-up screen will appear.
6. Open the English language folder, then double click on the Dimâge Scan Elite Installer.
Continued on the following page.
Please remove or disable any antivirus system extensions before launching this installer.These extensions may conflict with the operation of this installer. Replace or re-enable them when installation is complete.Hold the shift key down during startup to disable the extensions.
5. Double-click on Driver folder.
• The language folders will appear.
16
10. Click on .
11. Click on .
• The software will be installed in a new folder titled Dimâge Scan Elite.
• If Easy Install was chosen, the Dimâge Scan Elite folder will contain the following items: DS_Elite Utility, DS_Elite Plug-in, and Read Me file.
INSTALLING THE SOFTWARE – MACINTOSH
9. Select the install drive (or folder) and type from the pulldown menus.
• You can also click on to select an install drive.
The following dialog box will appear.
Install type pulldown menu
Install location pulldown menu
Name and icon of the selected install drive or folder.
The following message appears when the installer is finished.
12. Drag the DS Elite Plug-in to the Import/Export folder in the Adobe Photoshop Plug-ins folder.
• If you have Power Book G3, select the DS Elite for PBG3 from the Install type pulldown menu.
STANDARD OPERATION
SCAN FLOW
Set the Preferences
Launch the Software
Load the Film Holder
Insert the Film Holder
Specify the Film Type
Prescan
Specify the Job Type
Orient the Image
Correct the Brightness,
Contrast, and Color
Save
Scan
18
LAUNCHING THE SOFTWARE
The TWAIN driver lets you control the software through another application, such as your image editing software.
Launching the TWAIN Driver — Windows
This manual uses Adobe Photoshop 4.0.1 as the host application. Commands may vary among applications.
1. Open the host application.
2. Select File > Import > Select TWAIN_32 Source...
3. Select DS_Elite, then click on Select.
4. Select File > Import > TWAIN_32.
The Select Source dialog box appears.
The software is ready for use when the Main window appears (p.20).
LAUNCHING THE SOFTWARE
19
The plug-in software lets you access the software through Adobe Photoshop.
Launching the Plug-in — Macintosh
1. Launch Adobe Photoshop.
2. Photoshop 4.0.1 and newer: Select File > Import > DS_Elite Plug-in. Photoshop 3.0.5: Select File > Acquire > DS_Elite Plug-in
The software is ready for use when the Main window appears (p.20).
Launching the Utility Software
Select Start > Programs > Minolta Dimâge Scan Elite > DS Elite Utility
Windows
Double click on .
Macintosh
The software is ready for use when the Main window appears (p.20).
Use the utilty software, as a stand alone application, when you just want to scan the photographic image and store.
MAIN WINDOW—NAME OF PARTS
20
MAIN window
The Command Window part — Name of parts
Film format list box
Film format list box
Index Scan button
Prescan button
Scan button
Navigation button
Close button
Status bar
Help button ( on Macintosh)
Preferences button
APS Rewind button
Index scan (see page 56) / Prescan (see page 26) / Image Correction (see page 34) tab part
Scan Setting part (see page 68)
Command Window part (see below)
SETTING THE PREFERENCES
21
1. Click on .
Auto Expose for Slides checkbox
Close Driver software After Scanning checkbox
Digital ICE Setting box
2. Set the preferences as desired.
Select this checkbox when scanning underexposed slides.
Closes the scanner's driver software after the scan is complete.
Select the DIGITAL ICE (removing dust or scratch) from OFF and ON. This function is not avaialble for monochrome film.
Color depth Setting box
The pixel depth of each color channel used to scan your image (RGB or CMY).Three options are available:
• 8-bit – over 16.7 million colors
• 16-bit – over 2.8 billion colors
• 16-bit linear – same as 16 bit, but image correction is not applied when the image is scanned.
3. Click on to accept the new preference settings.
• Changes to the Preference settings take effect immediately.
Multi-Sample Scanning Setting box
This function reduces the random noise by referring the average of the result while scanning several times. Select the times of scanning operation from OFF, 2 times, 4 times, 8 times and 16 times.
COLOR MATCHING Settings (See page 66.)
APS Settings (See page 57.)
The Preference Dialog Box — Name of parts
LOADING THE FILM HOLDER
22
2. Place the film in the film holder emulsion side up.
• The film holder will accept film
strips up to 6 frames long.
• Br ush dust off the film before
placing it into the film holder.
Using the included 35mm negative and slide holders, the Minolta Dimâge Scan Elite can scan mounted or unmounted…
• 35mm colour negatives • 35mm colour slides
• 35mm black & white negatives • 35mm black & white positives
Advanced Photo System negatives and slides can also be scanned using the optional AD-10 APS Adapter.See page 57.
1. Open the film holder.
3. Align the frames within the scanning windows.
4. Snap the film holder closed.
Loading the Negative Holder
The frame numbers
and text are
backwards when the
film’s emulsion side
is up.
LOADING THE FILM HOLDER
23
Loading the Slide Holder
Do not scan glass
mounted slides. Glass mounts bend the light from the line scanner,
producing bad results.
1. Insert slides into the slide holder emulsion side up.
• Br ush dust off the the slide before placing it into the film holder.
• Slide mounts must be thicker than 1 mm and thinner than 2 mm to fit
into the slide holder.
• Or ient the slides horizontally, not vertically.
INSERTING THE FILM HOLDER INTO THE SCANNER
24
The white mark
should be upright.
The notches in the film and slide holders identify the position of the scanning windows. Push the holder all the way in to scan the last frame on that side of the film holder. Remove, flip, then re-insert the film holder to scan the frames on the other side of the holder.
Remove, flip, then re-insert the negative holder to scan frames 4, 5, or 6.
• Frames 3 or 4 with the slide holder.
• The blue mark should be upright
Insert the negative holder into the scanner’s film slot to scan frames 1, 2, or 3.
• Frames 1 or 2 with the slide holder.
Do not bend
negative holder
when inserting or
removing scanner.
Loading...