Printed in Japan9242-4889-11
©2002 KONICA MINOLTA SENSING, INC.
8
Units : mm
217
40.2
32
100
255
73
Data Processor DP-400
Measuring Head CR-400 Measuring Head CR-410
DimensionsSpecifications
Color Data Software CM-S100w
SpectraMagicTMNX
CR-400 Utility Software
CR-S4w
White Calibration Plate
CR-A43
White Calibration Plate
CR-A44
Protective Cap
CR-A72
Protective Cap
CR-A104
RS-232C Cable
CR-A101(Head-DP)
RS-232C Cable
CR-A102(for PC)
AC Adapter AC-A17
AC Adapter AC-A23(for Korea)
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Hard Case
CR-A103
Roll Paper (one roll)
Roll Paper
DP-A22(five rolls)
4 AA Size Batteries
4 AAA Size Batteries
Glass Light-Projection Tube
CR-A33a/f
Light-Projection Tube
CR-A33c/d
Glass Light-Projection Tube
CR-A33e
Granular-Materials Attachment
CR-A50
Pivoting Base
CR-A12
Color Tiles
Standard accessor y
Optional accessor y
M
e
a
su
r
i
n
g
H
e
a
d
C
R
-
4
0
0
M
e
a
su
r
i
n
g
H
e
a
d
C
R
-
4
1
0
D
a
t
a
P
r
o
ce
sso
r
D
P
-
4
0
0
Standard/Optional
accessories
63 102 63 102
67.5
244
32
Name Data Processor
Model DP-400
Display range Y : 0.01 to 160.00% (reflectance)
Measurement time∗2 1 Seconds.
Minimum measurement interval∗2 3 Seconds.
Battery performance Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
Illuminants C, D65
Display Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
Tolerance judgment∗2 Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Color space/ XYZ,Y x y, L∗a∗b∗, Hunter Lab, L∗C∗h, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
colorimetric data LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C),YI ASTM E313 (only illuminant C),
User index (up to six registered in the Measuring Head can be used)
Languages Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
Storable data sets Max. 2000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Color difference target colors∗2 Only for the operating function (100 pieces of data when the measuring head is connected; input of
measurement values or numeric) (independent of page function)
Calibration channels∗2 Only for the operating function (20 channels when the measuring head is connected)
(ch00: white calibration; ch01 to ch19: user calibration)
Page function 100 pages
Display Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384 dot line thermal printer (
can also print graphs
) Automaticallyprints out all measurement results(
can be set not to print
)
Statistical function Maximum, minimum, average, and standard deviation
Automatic measurement
∗
2
Date and time display: year, month, day, hour, minute
Timer: 3seconds. to 99 minutes.
(Some measurement modes require more than 3 seconds.)
Interface RS-232C compliant Baud rate (bps) : 19200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the measurement head
Power source 4 AA size alkaline or Ni-MH batteries,
AC adapter (AC-A17) AC120V 50-60Hz 0.4A (for N.America and Japan)
AC230V 50-60Hz 0.4A (for worldwide except N.America)
Size 100(W) x 73(H) x 255(D)mm
Weight Approx. 600g (not including batteries and paper)
Operating temperature/ 0 to 40°C, relative humidity 85% or less (at 35
°C)
with no condensation
humidity range
∗
Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation
Storage temperature/humidity range
-20 to 40°C, relative humidity 85% or less (at 35
°C)
with no condensation
Other User calibration function (multi-calibration/manual calibration)∗2, Measurements for automatic average
function, Print ON/OFF function. CR-400 measurement data impor t function∗2, All color space print ON/OFF
function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display
color limit function, Remote mode (stored data output), Character input function (alphanumeric)
∗
2 indicates that part of or all functions are not available when the measurement head is not connected.
Name Chroma Meter Measuring Head
Model CR-400 Head CR-410Head
Illuminating/viewing system
d/0 (Diffuse illumination/0°viewing angle)
Wide-area illumination/0° viewing angle
(Specular component included) (Specular component included)
Detector Silicone photo cells (6)
Display range Y: 0.01 to 160.00% (reflectance)
Light source Pulsed xenon lamp
Measurement time 1 seconds.
Minimum measurement interval
3 seconds.
Battery performance Approx. 800 measurements
(when using batteries under company testing Konica Minolta's conditions)
Measurement/illumination area
φ8/φ11 φ50/φ53
Repeatability Within ∆E*ab0.07 standard deviation (when the white calibration plate
is measured 30 times at intervals of 10 seconds)
Inter instrument ∆E*ab: within 0.6 ∆E*ab: within 0.8
agreement Average of 12 BCRA series II colors
Observer 2 degrees Closely matches CIE 1931 Standard Obser vers: ( x2λ, yλ, zλ)
Illuminant∗1 C, D65
Display∗1 Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgment∗1 Color difference tolerance (box tolerance and elliptical tolerance)
Color space/
XYZ, Y x y, L∗a∗b∗, Hunter Lab, L∗C∗h, Munsell (only illuminant C), CMC(l:c), CIE1994, Lab99,
colorimetric data
LCh99, CIE2000, CIE WI•Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages Operating keys : English
LCD : English (default)
(LCD : German, French, Italian, Spanish, Japanese) *1
Storable data sets 1000 (measuring head and data processor save different data)
Color difference target colors
100
Calibration channels
*1 20 channels (ch00 : white calibration, ch01 to ch19 : user calibration)
Display
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface RS-232C compliant (for data processor/PC)
* Baud rate : 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
Power source 4 AAA size alkaline or Ni-MH batteries,
AC adapter (AC-A17) AC120V 50-60Hz 0.4A (for N.America and Japan)
AC230V 50-60Hz 0.4A (for worldwide except N.America)
Size
102(W) x 217(H) x 63(D)mm 102(W) x 244(H) x 63(D)mm
Weight Approx. 550g Approx. 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operating temperature/
0 to 40°C, relative humidity 85% or less (at 35°C) with no condensation
humidity range
∗
Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation
Storage temperature/humidity range
-20 to 40°C, relative humidity 85% or less (at 35°C) with no condensation
Other LCD back light ON/OFF function (when ON, back light stays ON for 30
seconds after last key or measurement operation)
∗
1 indicates when connected to the Data Processor or when not set using the Data Processor or the optional software,
that some of the function are not available when the measuring head is not connected.