Color Data Software CM-S100w
TM
SpectraMagic
NX
Color Quality control like never before:Color Quality control like never before:
Color Quality control like never before:
• Unprecedented ease of use Unprecedented ease of use
• Unprecedented ease of use
• Prefixed Templates Prefixed Templates
• Prefixed Templates
• Step by step Navigation help Step by step Navigation help
• Step by step Navigation help
• Customized Reports including Digital Images Customized Reports including Digital Images
• Customized Reports including Digital Images
• Includes Includes “Precise Color CommunicationPrecise Color Communication” tutorial tutorial
• Includes “Precise Color Communication” tutorial

Information input for measurement data
Additional items of information can be input for measurement data, which is useful for
organizing, sorting, or searching for data. These added items can also be displayed
on a graph. Information such as model name, item name, product No., code No.,
name, order No., color No., production lot No., customer name, product name, visual
judgment result (pass/fail input), temperature, humidity, etc. can be input.
temperature
temperature
Printing example of
a shipment slip
Pre-configured templates for various applications
Various printing functions
Like the display view, the printing view can be used to create your own format by
placing and editing objects as desired. This function is useful for preparing easy-toread reports or for filling in shipment slips. Moreover, several pieces of data can be
combined and printed on one sheet.
Comprehensive graphs and color difference assessments
SpectraMagic™ NX helps you to make color quality control easy and comprehensive at
once. You can choose from several graphs together with the latest Pass/Fail color
difference assessment equations, such as CIE 1994 or CIE DE2000 and several
industry- related indices. Tolerances, both in box or elliptical form can be automatically
calculated or manually adjusted to approved standards. Furthermore, SpectraMagic™
NX features a “User Index” function that allows you to configure up to 3 customized
color equations to meet industry-specific requirements for color evaluation. Auto Target
is an additional feature that makes QC with SpectraMagic™ NX so easy and fast.
Spectral graph
Color graph
Status window shows Instrument Information at a glance
Data compatibility with the former SpectraMagic
Trend graph
Color difference
graph

Pre-configured templates for various applications
Te mplates designed for various applications are ready for immediate use.
Support for the CM-512m3
(multi-angle spectrophotometer)
The SpectraMagic™ NX also supports the CM512m3 multi-angle spectrophotometer, which
provides measurement values using three
illumination angles with one measurement. The
data of the three angles can be displayed
simultaneously, and the angle characteristics
specific to multi-angle spectrophotometer can be
displayed visually with line graphs.
E00 (CIE DE2000) display
It is now possible for display E00 (CIE DE2000).
This is an improved color-difference equation
based on the L*a*b* color space which provides
better correlation between the color difference
value and visual evaluation for subtle color
differences.
Te mplate sample for the automobile industry
Status window shows Instrument Information at a glance
With SpectraMagic™ NX, all Instrument Information (status,
measurement options, last calibration, comunication status and
instrument settings) can be seen at a glance.
Data compatibility with the former SpectraMagic
The SpectraMagic™ NX is data-compatible with the former SpectraMagic™ software.
The old data can be used without any treatment.
Data displayed with the old SpectraMagic™
Data displayed with the SpectraMagic™ NX

Comprehensive reporting and easy data export
SpectraMagic™ NX allows you to insert digital pictures with the measured data, opening
totally new dimensions to color communications with customers. The data list view
allows you to swiftly export measurement data into Excel by copy and paste function.
Reports as well can be created by the user with total freedom to meet traceable
evidence of color consistency demanded by customers. Furthermore, SpectraMagic™
NX can share data within a local area network (LAN) and operates under Windows
2000 Professional and XP Professional.
SpectraMagic™ NX Color Data Software
Specifications:
Minimum Computing Requirements
OS Windows
CPU Pentium
Memory 128 MB (256 MB recommended)
Hard disk 450 MB of available disk space (At least 400 MB of available space is required in the system drive.)
Display Display unit capable showing at least 1024 x 768 dots/256 colors
Other CD-ROM drive (required for installation), One free USB port or printer port (for protection key),
One free serial port (for instrument), Internet Explorer Ver. 5.01 or later
Compatible Instruments
CM-3700d; CM-3600d; CM-3610d; CM-3630; CM-3500d; CM-700d/600d; CM-2600d/2500d/2500c;
CM-2002; CM-500 Series; CM-512m3; CR-400/410, DP-400; CR-300/CR-200 Series (The CR-300/200
Features
Color space L*a*b*, L*C*h, XYZ, Hunter Lab, Yxy, L*u'v', L*u*v*, Lab99, LCh99, Munsell, and their color differences
Index MI, WI (CIE 1982, ASTM E313-73, ASTM E313-96, HUNTER, BERGER, TAUBE, STENSBY, Ganz), Tint
®
* With some instrument types, the illuminating/light-receiving optical system may not satisfy the definition of haze (ASTM D1003-97).
Color difference equation E*ab (CIE 1976), E*94 (CIE 1994) and each component of lightness, saturation and hue,
Automated operation by macro function
You can easily register routine operation flows as macros using the menu screen to
automate operation processes. This is effective for reducing working time as well as
preventing operation mistakes.
Calibration
(Operation flow example)
Calibrate the instrument
before measurement,
repeat measurement 30
times at 10-minute
intervals, and then save
the data.
Wait for 10 minutes.
30 times
Measurement
Save data by overwriting old data.
Navigation function & Color tutorial for total workflow control
With the exclusive Navigation function, you have total control of the flow of operations with
online step-by-step instructions including picture illustrations. This unique feature can be
customized by the user according to his needs. The Navigation window of SpectraMagic™
NX also includes a link to the HTML version of “Precise Color Communication” with many
illustrations and explanations that contribute to a clearer understanding of basics and
technical terms related of color and color measurement technology.
Ep (degree) (DIN 6175-2)
Observer 2 degree, 10 degree
Illuminants A, C, D50, D55, D65, D75, F2, F6, F7, F8, F10, F11, F12, U50
Graph display Spectral reflectance (transmittance) and its difference, K/S and its difference, Absorbance and its
Image display Link between measured value and image data (JPEG or BMP format), Insertion of custom images
Instrument control Measurement/calibration
Automatic average measurement: 1 to 999 measurements
Manual average measurement: Any number of measurements (Standard deviation and average value are
Remote measurement (Excluding the CM-3000 Series)
Instrument setting (Excluding the user-calibrated UV Adjust)
Upload of data stored in the instrument (Excluding the CM-3000 Series)
List view of data stored in the instrument (Excluding the CM-3000 Series)
Target
Data list List view and editing of target/measured data (delete, sort, averaging, copy & paste), Link between JPEG
Visual judgement result writing function, Additional data information inputting/listing function
External I/O Loading/saving data files in original format (Extension: mes) (Several files can be loaded.)
Loading/saving template files in original format (Extension: mtp) (Several files can be loaded.)
Saving of data in text format (CSV, TXT), saving of data in XML format, Copy of listed data in the clipboard
Help function Navigation display
Other
Screen display Number of files that can be opened simultaneously: 20
Number of data that can be stored in a file: Target data: 5,000, Measurement data: 5,000
Instrument status details window display, “Precise Color Communication” Tutorial
Operation Operation is easy thanks to an operation screen with large buttons, use of function-assigned keys instead
2007

SpectraMagic™ NX Color Data Software
Specifications:
Minimum Computing Requirements
OS Windows® 2000 Professional SP 4
CPU Pentium® III 600 MHz or higher (recommended)
Memory 128 MB (256 MB recommended)
Hard disk 450 MB of available disk space (At least 400 MB of available space is required in the system drive.)
Display Display unit capable showing at least 1024 x 768 dots/256 colors
Other CD-ROM drive (required for installation), One free USB port or printer port (for protection key),
One free serial port (for instrument), Internet Explorer Ver. 5.01 or later
Compatible Instruments
CM-3700d; CM-3600d; CM-3610d; CM-3630; CM-3500d; CM-700d/600d; CM-2600d/2500d/2500c;
CM-2002; CM-500 Series; CM-512m3; CR-400/410, DP-400; CR-300/CR-200 Series (The CR-300/200
Features
Color space L*a*b*, L*C*h, XYZ, Hunter Lab, Yxy, L*u'v', L*u*v*, Lab99, LCh99, Munsell, and their color differences
Index MI, WI (CIE 1982, ASTM E313-73, ASTM E313-96, HUNTER, BERGER, TAUBE, STENSBY, Ganz), Tint
* With some instrument types, the illuminating/light-receiving optical system may not satisfy the definition of haze (ASTM D1003-97).
Color difference equation E*ab (CIE 1976), E*94 (CIE 1994) and each component of lightness, saturation and hue, E00 (CIE
Ep (degree) (DIN 6175-2)
Observer 2 degree, 10 degree
Illuminants A, C, D50, D55, D65, D75, F2, F6, F7, F8, F10, F11, F12, U50
Graph display Spectral reflectance (transmittance) and its difference, K/S and its difference, Absorbance and its
Image display Link between measured value and image data (JPEG or BMP format), Insertion of custom images
Instrument control Measurement/calibration
Automatic average measurement: 1 to 999 measurements
Manual average measurement: Any number of measurements (Standard deviation and average value are
Remote measurement (Excluding the CM-3000 Series)
Instrument setting (Excluding the user-calibrated UV Adjust)
Upload of data stored in the instrument (Excluding the CM-3000 Series)
List view of data stored in the instrument (Excluding the CM-3000 Series)
Target
Data list List view and editing of target/measured data (delete, sort, averaging, copy & paste), Link between JPEG
Visual judgement result writing function, Additional data information inputting/listing function
External I/O Loading/saving data files in original format (Extension: mes) (Several files can be loaded.)
Loading/saving template files in original format (Extension: mtp) (Several files can be loaded.)
Saving of data in text format (CSV, TXT), saving of data in XML format, Copy of listed data in the clipboard
Help function Navigation display
Other
Screen display Number of files that can be opened simultaneously: 20
Number of data that can be stored in a file: Target data: 5,000, Measurement data: 5,000
Instrument status details window display, “Precise Color Communication” Tutorial
Operation Operation is easy thanks to an operation screen with large buttons, use of function-assigned keys instead
SAFETY PRECAUTIONS
For correct use and for your safety,
be sure to read the instruction manual
before usin
Windows® XP Professional SP 2, x64 Edition
Windows® Vista Business 32bit (x86), 64bit (x64)
(English, Japanese, German, French, Spanish, Italian, Traditional Chinese, Simplified Chinese, and
Hangul versions
For Windows® XP Professional x64 Edition, English and Japanese versions only)
Series can be used only when the main unit is version 3.0 or later and is connected via RS-232C. The unit
cannot be used together with a USB converter.)
(excluding Munsell)
(CIE 1982, ASTM E313-96, Ganz), YI (ASTM D1925-70, ASTM E313-73, ASTM E313-96, DIN6167), WB
(ASTM E313-73), Standard Depth (ISO 105.A06), Brightness (TAPPI T452, ISO2470), Opacity (ISO 2471,
TAPPI T425 89% White Plate), Haze (ASTM D1003-97)*, Density (Status A, Status T), Dominant
Wavelength, Excitation Purity, RXRYRZ, 8 degree gloss value (CM-3600d, CM-2600d/2500d only), user
equation, each difference, 555, Strength, Pseudo Strength, Staining degree (ISO 105.A04E), Staining
degree rating (ISO 105.A04E), Grey scale (ISO 105.A05), Grey Scale Rating (ISO 105.A05), K/S strength
(Apparent ( E*ab, L*, C*, H*, a*, b*), maximum absorption, total wavelength, user wavelength),
NC#, NC# Grade, Ns, Ns Grade
However, this presents no problem as long as the value is used as a relative value.
DE2000) and each component of lightness, saturation and hue, E99 (DIN99), E (Hunter), CMC (I:c) and
each component of lightness, saturation and hue, FMC-2, NBS 100, NBS 200, Ec (degree) (DIN 6175-2),
difference, L*a*b* absolute value, L*a*b* (2D/3D color difference distribution, MI), xy chromaticity
diagram, Trend chart and histogram of each color space and color difference equation
displayed in the color space selected during measurement.)
Registration of several target colors (Automatic target color selection), Manual input and registration of colorimetric
data by specifying color space, Target data download to the instrument (Excluding the CM-3000 Series)
images, Display of statistic value and pass/fail ratio
of a mouse, the Navigation function, and the Macro function.
• The specifications and drawings given here are subject
to change without prior notice.
®
is a trademark of Microsoft Corporation in the
USA and other countries.
®
is a trademark of Intel Corporation in the
USA and other countries.
the product.
Certificate No : YKA 0937154
Registration Date : March 3, 1995
Certificate No : JQA-E-80027
Registration Date : March 12, 1997
• Windows
• Pentium
2007 KONICA MINOLTA SENSING, IN
http://konicaminolta.com/instruments/about/network
HLAPA
nted in Japa