Konica Minolta CM3600D User Manual

Built for Precision, Priced for Economy
The result:
n A highly accurate, reliable, rugged spectrophotometer. n Versatile enough for all colorimetric applications. n Simplified operation.
And
n LOW PRICE
KONICA MINOLTA Innovative Optical System "World first" technology :
n Numerical Gloss Control measurement within a few seconds. n Numerical UV Control for calibration and measurements. n Soft-flash mode to avoid triplet adsorption in fluorescent materials.
New Enhanced Performance Technology teams patented performance features with simplified design and advanced cost-reducing manufacturing techniques.
Technology
UV-adjusted data
ON
POWER
OFF
244
54 89
35 378
208
17
Performance
Fast, simultaneous measurement of Specular Included and Specular Excluded components (SCI/SCE)
Versatility
Full wavelength range 360-740nm with 10nm pitch
Reliability
The Innovative CM-3600d Spectrophotometer Brings You Highest Quality Levels in Color Measurement along with Unsurpassed Versatility, User Comfort and Low Cost!
High reliability design with fewest moving parts of any benchtop spectrophotometer
Large (6") sphere; d/8° geometry Reflectance and transmittance sample measurements Changeable measurement areas (ø4mm,ø8mm,or ø25.4mm) View finder design for easy sample viewing Compact and lightweight
Fast, Instantaneous numerical UV adjustment enables UV-included, UV-excluded, and UV-adjusted data to be obtained simultaneously Precise inter-instrument agreement. All CM-3600d's meet published inter-instrument agreement.
The CM-3600d is equipped with maintenance-free technology and solid state components to withstand rugged conditions. The monolith polychromator unit assures highest durability and stability. With one exception (Observing Lens), the CM-3600d does not use any moving parts. Furthermore, each CM-3600d passes a hard endurance test program to comply with KONICA MlNOLTA's highest quality standards in accordance with ISO-9001.
Compact but yet Powerful
Behind the compact and space­saving design, you'll find the skills of a top-class instrument with 6" large sphere and other functions so far only found in much larger and more expensive instruments.
Full range of application coverage
For high-accuracy color control The newly designed Monolith Polychromator Unit
Maintenance free technology and ruggedness concept
LAV
25.4mm
MAV 8mm
SAV 4mm
Konica Minolta's Innovative Optical System, including Numerical Gloss Control and Numerical UV Control, opens the way to unlimited application versatility at a price level never seen before.
Whatever your sample looks like, with the CM-3600d you can measure it! Reflectance of opaque samples, Transmittance of transparent liquids or solids and Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is truly versatile.
Transmittance Measurement-The CM-3600d employs the d/0° geometry (diffused lighting, 0° viewing), which conforms to ISO, DIN, CIE, and ASTM standards.
Reflectance Measurement-The CM-3600d employs d/8° geometry (diffused lighting, 8° from normal viewing) which conforms to JlS, ISO, DIN, CIE and ASTM standards.
consists of a diffraction grating with a full wavelength range, 360-740 nm, at 10nm pitch, and 10nm half-band width, both for sample and reference light, and dual-channel sensor array.
The retro mirror's reflected and illuminated sample viewing screen minimizes fatigue and allows trouble-free sample observation.
The compact and space-saving body as well as all functions of the CM-3600d have been designed to ensure easy and fatigue-free operation in daily use. The bright mirror sample viewing system, the sample holder for up to A4 size samples with full 90° lock down, and the versatile Transmittance chamber for liquid or translucent samples are all just where you expect them to be for easy operation.
1.Numerical Gloss Control
Enhanced Performance Technology Konica Minolta Innovative Optical System
2.Numerical UV Control
SCI
………
specular component included
SCE
………
specular component excluded
The CM-3600d is equipped with Minolta Innovative Optical System technology. For users, this means high accuracy and repeatability, improved performance, additional features, simple operation, and - low, affordable pricing.
Instead of using a mechanically driven gloss trap, the CM-3600d is equipped with a patented numerical Gloss (SCl/SCE) control system. By sequentially firing two flashes, within a few seconds the system provides both SCI and SCE values for each sample.
To replace the time-consuming traditional UV measurement system that utilizes moving filters, the CM-3600d introduces yet another patented numerical calculation system, never seen before: The measured values of two sequentially fired flashes, one with full UV energy and one with UV cut-off filter at either 400 or 420 nm are combined to obtain the spectral characteristics, and the respective whiteness and tint value of any UV­activated fluorescence sample. To avoid triplet effect on FWA treated samples, the CM-3600d can be set to Soft-Flash mode. Numerical UV Control technology makes faster, more effective and reliable measurements of FWA treated materials such as textiles, papers and detergents.
This technology also provides:
Konica Minolta Innovative Optical System Technology
Designed to meet your highest ergonomic expectations
To cover all kinds of samples, the CM-3600d gives you the choice among three aperture sizes: LAV 25.4mm, MAV 8mm and SAV 4mm with precise measurement spot adjustment by a motorized observing lens.
Multiple measurement area selection
Bright and clear sample viewing system
Dimensions
(Units:mm)
SpectraMagic
TM
NX enables you to perform comprehensive color
inspection a nd analysis of incom ing raw materials, i n process production, and outbound color critical g oods and materials in virtually an y industry. With Spe ctraMagic
TM
NX you can in sert
digital images with measured data. Measure samples in any of 8 universally accepted color spaces. Select from 15 illuminants, and up to 40 ind ices to determ ine specific color a nd appearance properties, such as strength, brightness, haze, yellowness, opacity and strength. You can even configure up to 3 customized color equations. Reports range from simple Pass/Fail to trend charts, histograms, color plots, and spectral graphs. SpectraMagic
TM
NX
comes with predefined templates using skin technology, or you can create your own templates. For illustrations and explanations to understanding color and color measurement technology, there is a link to Konica Minolta's well known and respected “Precise Color Communication”. Step by step navigation help. SpectraMagic
TM
NX
conforms to FDA 21 CFR Part 11 assuring integrity and reliability of data records.
• Windows® is a trademark of Microsoft Corporation in the USA and other countries.
Supports Windows®2000/XP
SpectraMagic
TM
NX
(
Optional
)
Mac OS 10.3.7Jillustrator 10J
CM-3600d_inside.ai2006.11.21
Personal Computer
Unit Driver
CM-A108
Accessory Case
CM-A109
Dust Cover
CM-A110
Spectrophotometer CM-3600d
Standard accessories Optional accessories
Target Mask CM-A105 ( 25.4mm)
AC Adapter AC-A12 AC Adapter AC-A21 (for Korea)
RS-232C Cable IF-A12 (for IBM PC)
White Calibration Plate CM-A103
(with floppy disk containing calibration data)
Target Mask CM-A106 ( 8mm)
Target Mask CM-A107 ( 4mm)
Cell CM-A99 (20mm)
Cell CM-A98 (10mm)
Cell
CM-A97
(2mm)
Plastic Cell
CM-A132
(20mm; set for 100)
Plastic Cell
CM-A131
(10mm; set for 100)
Plastic Cell
CM-A130
(2mm; set for 100)
Transmittance. Zero Calibration Plate CM-A100
Transmittance
Specimen Holder
CM-A96
Zero Calibration Box
CM-A104
RS-232C Cables IF-A13 to IF-A15
Color Tiles
SpectraMagicTMNX
CM-S100w
System Diagram
Specifications
Network construction for color control either within an organization or between organizations
In-house color control
Color control between companies
R&D
Design
Production
Company
A
Company
B
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series CM-3600d CM-3500d CM-2600d/2500d/2500c
"State of the Art" Reference models Laboratory and Production modell Unique Top Port bench-top model Top class accuracy portables
CM-3500d
CM-3700d
CM-2000/2600d/2500c
series 2500d
CM-3600d
High inter-instrument agreement between the same Konica Minolta model and also among all CM models (benchtops and portables): CM-2000 series, CM-3000 series, This inter-instrument agreement is ideal when multiple units will be used for color control either within an organization or between organizations.
Standard accessories
Size (W x Hx D)/weight
Storage temperature/ humidity range
Operating temperature/ humidity range
(*1)
Power
Interface
Transmittance chamber
UV cut filter
UV adjustment
Temperature dependence
Inter instrument agreement
Repeatability
Measurement/ illumination area
Minimum interval between measurements
Measurement time
Light source
Sphere size
Reflectance range
HaIf bandwidth
Wavelength pitch
Wavelength range
Illumination/ observation system
Light-receiving element Spectral separation device
White Calibration Plate,Target Mask (ø4mm) ,Target Mask(ø8mm) ,Target Mask (ø25.4mm) , Zero Calibration box,AC adapter, Dust Cover,Accessory Case, Unit Driver, RS-232C Cable (9-pin,2m)
Options
SpectraMagicTMNX(software) ,Transmittance Specimen Holder, Cell (2mm) / (10mm) / (20mm), Transmittance Zero Calibration Plate, RS-232C Cable (IBM,PC/AT 5m) / (IBM,PS/22m) / (IBM,PS/2 5m)
244 x 208 x 378 mm(9-5/8 x 8-3/16 x 14-7/8 inch),12 kg(26-7/16 lb.)
0 to 40°C, relative humidity 80% or less (at 33°C) with no condensation
13 to 33°C, relative humidity 80% or less (at 33°C) with no condensation
AC120V/230V 50/60Hz (Using included AC adapter)
RS-232C, D-SUB 9-pin (female) terminal
Width: 133mm; depth: approx. 50mm; measurement dia.: approx. 17mm Transmission sample holder (Optional accessory): Sample holder; for both plate-shaped and liquid samples (removable)
400nm cutoff and 420nm cutoff
Instantaneous numerical adjustment
Spectral reflectance: Within ±0.10%/°C Color difference: Within E*ab 0.05/°C
Mean E*ab0.15 (LAV/SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body.
Spectral reflectance: Standard deviation within 0.1% Colorimetric values: Standard deviation within E*ab0.02
LAV : ø25.4mm/ø30mm MAV: ø8mm/ø11mm (Selectable) SAV : ø 4mm/ø7mm
Approx. 4 seconds;when SCI/SCE measured
Approx. 1.5 seconds
Pulsed xenon lamps (X4)
ø152mm
0 to 200%; resolut ion: 0.01%
Approx.10nm
10nm
360 to 740nm
Reflectance;d/8 (diffused illumination, 8-degree viewing), equipped with simultaneous measurementof SCI (specular componentincluded) / SCE (specular component excluded)Conforms toCIE No.15,lSO7724/1,ASTME1164,DIN5033 Teil7 and JIS Z8722 condition C standard. Transmittance : d/0 (diffused illumination, 0­degree viewing) Conforms to CIE No.15, ASTME1164 and DIN5033 Teil7 standard.
Silicon photodiode array (dual 40 elements) Diffraction grating
The result:
n A highly accurate, reliable, rugged spectrophotometer. n Versatile enough for all colorimetric applications. n Simplified operation.
And
n LOW PRICE
KONICA MINOLTA Innovative Optical System "World first" technology :
n Numerical Gloss Control measurement within a few seconds. n Numerical UV Control for calibration and measurements. n Soft-flash mode to avoid triplet adsorption in fluorescent materials.
New Enhanced Performance Technology teams patented performance features with simplified design and advanced cost-reducing manufacturing techniques.
Technology
*1 Operating temperature/humidity range of products for North America : 13 to 33°C, relative humidity 80% or less (at 31°C) with no condensation
SAFETY PRECAUTIONS
AGMFP
K
Printed in Japan9242-4868-11
©1998 KONICA MINOLTA SENSING, INC.
15
For correct use and for your safety, be sure to read the instruction manual before using the instrument.
Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Certificate No : JQA-E-80027
RegistrationDate: March12, 1997
Certificate No : YKA0937154
RegistrationDate: March3, 1995
Loading...