Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
·
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
·
These instructions contain important care, cleaning, and
warranty information -.please leave instructions for the
consumer
RECOMMENDED TOOLS AND MATERIALSRECOMMENDED TOOLS AND MATERIALS
Open end/adjustable wrenches
·
Tape measure
·
Basin wrench
·
Pipe wrench
·
Square
·
Level
·
Pliers
·
Socket wrench with sockets
·
Screw driver
·
Seal tape
·
Connection wire
·
Wire cutter
·
Insulation tape
·
Bushing
·
Drill
·
Sealant
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
-
/
1154809-T01-B
-1-
528137
, 2011
Copyright Kohler China Ltd., 2011
SENSOR SPECIFICATIONSSENSOR SPECIFICATIONS
Model
Power
Liter per flushing
Temperature
Starting pressure
Sensing distance
Testing time
Flushing mode
Water pressure at 0.18~0.55 MPa: Average flushing no more than 0.5L
Environmental temperature: 1 to 55 C
0.05~0.86MPa
70cm away from sensing window (Automatic adjustiment range: 50~70cm)
About 2 seconds or 5 seconds (Automatic adjustment)
Flushing after used
2 "AAA" size alkaline batteries
Note: the sensing distance in the table is measured with a 30 30cm white board as the reflecting surface.
2 7(AAA 2)
16321T-Y
16321T-Y
16321T-YC05
220V AC 50/60Hz
2
16321T-YC05
220V 50/60Hz
0.18~0.55MPa.0.5L
1~ 55 C
0.05~0.86MPa.
70cm(50~70cm)
25()
30 30cm
2
ROUGHING-IN
Reference Value
332
180
G1/2
55
50 ext
145
600
35
80
**
180 5
180
Kohler reserves the right to change marked dimensions without prior notice.
Unit:mm
642
303
Notice: a. The dimensions above are just for reference.
b. The layout dimensions of waterand outlet see
inlet
installation step B(Install the hook).
c. ** Indicates the location of inlet pipe, while inlet
connector size is G 1/2.
I
d. * Recommended dimensions for installation only,
please adjust according to actual situation.
1154809-T01-B
a.
b.B()
c. **G 1/2
d. *
-2-
Notice: To ensure an effective flush performance,
strongly recommended inner diameter of
water supply (including water meter, valve,
etc.) is no less than 25mm, and supplied
water pressure (sensor inlet dynamic
pressure) is 0.18MPa ~0.55MPa.
INSTALLATION
1. Please install 16321T-YC05(AC) as below:
Please directly reference to Step 2 when installing 16321T-Y
(DC).
(
)25mm(
) 0.18MPa ~0.55MPa
A.
Please match 16306T-NA AC power unit when installing
16321T-YC05 (AC).
CAUTION:
a. Outlet of AC power unit upward prohibited.
b. Do not connect 220V AC power supply to DC wiring
terminal.
c. Do not damage the covering of AC power unit or
remove screws to avoid leakage.
1.()
16321T-YC05
16321T-Y
()2
16321T-YC05
()16306T-NAA.
a.
b.220VDC
c.
B
. AC power unit connected to electric control box by
connection wire.
Notice:
The length of the connection wire should keep
the connector out of the urinal. It s convenient
'
connect.
Connect to
Sensor
AC
Outlet Downwards
Connect to AC
Power Supply
Connector
Connect to AC
Power Supply
Wire Prepared
By Customer
Outlet Upwards
Connector
Connect to
Sensor
B.
C
. When installing the power unit on the ceiling, please
chisel out a slot and layout bushing according to Fig., and
thread wire through the bushing.
CAUTION:
One AC power unit can supply two
sensors at most.
C.
1154809-T01-B
16306T-NA
AC Power Unit
-3-
Connect with the same color wire,
and protect connect area by insulation tape.
AC Power Unit
Ceiling
Bushing(In-wall)
()
Slot
Bushing
Slot
Connect With
Control Box
(In-wall)
()
Notice:
a. Keep the connector away from water.
b. Do not connect the DC output of AC power
unit to AC power supply.
c. Do not connect to power supply while
installing. Connection line is not supplied.
AC connection wire with insulating sleeving
is recommended. Wire of which the
nominal section area of conductor is not
less than 0.5mm is also recommended.
2
DC connection line use wire of which the
nominal section area is not less than
2
0.3mm . It is cut according to acted
installation requirements(The length of cut
wire is recommended less than 10m).
d. The head AC power supply must be
protected with appropriate fuse.
e. Please confirm the AC power supply and
water supply should be shut off before
maintaining the products with AC power
related.
f. Don't install the AC power unit in the free
space behind the urinal to avoid damaging
the AC power unit.
2. Install urinal
Notes: a. Observe all local plumbing and building
codes.
b. Shut off the water supply.
c. Carefully inspect the new fixture for any sign
of damage.
d. Be very careful while hand ling vitreous
china products.
a.
b.
c.
d.
e.
f.
0.5mm
2
0.3mm
2
(10m)
2.
a.
b.
c.
d.
A.
Install outlet connection
Ascertain the position for outlet connection according to
rough-in dimension.
Connect the outlet connection with the S-trap way. Insert the
gasket into the S-trap way as shown. Apply sealant on outlet
pipe, connect the outlet connection with outlet pipe.
Maybe different for different outlet connections.
Note:
A.
S
S
30
X1X1
1154809-T01-B
-4-