Kohler K-1375 User Manual

Homeowners Guide
Bath with Airjets
K-1375
Write model number here: Écouter le numéro du modèle ici: Escribir el número del modelo aquí: ___________________ M product numbers are for Mexico (i.e. K-12345M)
Los números de productos seguidos de M corresponden a México (Ej. K-12345M) Français, page “Français-1” Español, página “Español-1”
1038265-5-B
Important Information
INSTRUCTIONS PERTAINING TO A RISK OF FIRE,
ELECTRICAL SHOCK, OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
WARNING: When using electrical products, basic precautions should always be followed, including the following:
WARNING: Risk of personal injury. Do not permit children to use this unit unless they are
closely supervised at all times.
WARNING: Risk of personal injury. To avoid injury, exercise care when entering or exiting the whirlpool.
WARNING: Risk of electric shock. Do not permit electric appliances (such as a hair dryer, lamp, telephone, radio, or television) within 5’ (1.5 m) of this bath with airjets.
WARNING: The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include: (a) failure to perceive heat, (b) failure to recognize the need to exit the bath, (c) unawareness of impending hazard, (d) fetal damage in pregnant women, (e) physical inability to exit the bath, and (f) unconsciousness resulting in the danger of drowning.
An equipment grounding terminal is provided in the field wiring compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply panel with a conductor equivalent in size to the circuit conductors supplying this bath with airjets.
A pressure wire connector is provided on the exterior of the blower motor or control within this unit to permit connection of a bonding conductor between this unit and all other exposed metal in the vicinity, as needed to comply with local requirements.
Use this bath with airjets only for its intended purpose as described in this manual. Do not use attachments not recommended by the manufacturer.
Never drop or insert any object into any opening. The bath with airjets must be connected only to a supply circuit that is protected by a Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD). Such a GFCI or RCD should be provided by the installer and should be tested on a routine basis. To test the GFCI or RCD, press the test button. The GFCI or RCD should interrupt power. Press the reset button. Power should be restored. If the GFCI or RCD fails to operate in this manner, the GFCI or RCD is defective. If the GFCI or RCD interrupts power to the bath without the test button being pressed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this bath. Disconnect the bath and have the problem corrected by a qualified service representative before using.
Your new Kohler bath with airjets has been listed by Underwriter’s Laboratories, thus ensuring safety for you and your family. Your new bath with airjets also conforms to rigid ANSI and IAPMO standards set within the plumbing industry.
1038265-5-B 2 Kohler Co.
Table of Contents
Important Information .............................................................. 2
Thank You For Choosing Kohler Company .............................................. 3
Your Kohler Bath with Airjets ........................................................ 4
User Keypad And Bath Modes/Features ................................................ 5
Operating Your Bath ............................................................... 7
Chromatherapy Operation (if Equipped) ................................................ 8
Care and Cleaning Instructions ....................................................... 8
Warranty ....................................................................... 9
Warranty ....................................................................... 9
Troubleshooting Procedures ........................................................ 10
Service Parts ................................................................... 14
Thank You For Choosing Kohler Company
Thank you for choosing Kohler Co. Your Kohler Co. product reflects the true passion for design, craftsmanship, artistry, and innovation Kohler Co. stands for. We are confident its dependability and beauty will surpass your highest expectations, satisfying you for years to come.
All information in this guide is based upon the latest product information available at the time of publication. At Kohler Co. we strive to fulfill our mission of improving the level of gracious living for each person who is touched by our products and services. We reserve the right to make changes in product characteristics, packaging, or availability at any time without notice.
Please take a few minutes to review this guide. Pay special attention to the care and cleaning instructions.
Kohler Co. 3 1038265-5-B
Bath
Chromatherapy Light
Airjet
User Keypad
Blower Motor
Control
Level Sensor
Your Kohler Bath with Airjets
Your new bath with airjets is designed to stimulate, invigorate, and energize your body. You will use the following components:
Bath - Allows the bather to relax in comfort while enjoying the air massage.
User Keypad - Located within easy reach, the keypad allows you to turn the bath on and off. It also
allows you to access the airjet modes and adjust the airflow.
Airjets - Holes through which the air flows. Chromatherapy Lights (if provided) - Adds ambience to your bath with a specific color or set the
bath to continuously cycle through all eight colors. Level Sensor - Determines when the bath has been drained and starts the timing for the automatic
purge cycle. Blower Motor - Provides quiet, variable speed power to force air through the airjets into the water
and create the soothing bubbling action.
1038265-5-B 4 Kohler Co.
Air Flow Mode
Activates Mode Selected
Rotate Outer Ring to Access Desired Mode
Power On/Off
Zone 1
Zone 2
Zone 3
Surge Mode
Increase Flow or Surge
Indicator Bar
Chromatherapy Specific Color (if provided)
Decrease Flow or Surge
Chromatherapy Cycle (if provided)
Purge Mode
User Keypad And Bath Modes/Features
Power On/Off - Turns the blower motor on and off. Symbols illuminated in blue indicate available modes/features. Modes which are operating will display in green.
Activate Button - Press “OK” to activate the desired mode. The active mode will flash (green). Up Arrow - Increases the air flow when the air flow mode is active. Increases the pulse speed when
the surge mode is active. Down Arrow - Decreases the air flow when the air flow mode is active. Decreases the pulse speed
when the surge mode is active.
Outer Ring - Rotate the outer ring to the desired mode. The selected mode will flash (blue). Indicator Bar - Shows the air flow volume when operating in the air flow mode. Shows the surge
speed when operating in the surge mode. Purge Mode - Select to initiate the purge mode manually. The purge cycle will not start if there is
water in the bath with airjets. The purge mode blows any residual water out of the air channels. The blower motor starts and runs at a low speed for about two minutes. An automatic purge cycle occurs when the bath is drained and the water level falls below the level sensors.
Air Flow Mode - In this mode, air flow is directed through any combination of the airjets in the selected zones. Air flow can be adjusted with the arrow buttons. When the surge mode is selected, the air flow mode stops. When the air flow mode is selected while operating in the surge mode, the surge mode stops.
Zone 1 - This mode is used to select or deselect the air flow through Zone 1. Zone 2 - This mode is used to select or deselect the air flow through Zone 2. Zone 3 - This mode is used to select or deselect the air flow through Zone 3. Surge Mode - When active, the air flow ramps up from minimum to maximum and then down
again to minimum. The surge speed is adjustable between approximately 10 seconds to 60 seconds by using the up or down buttons. The up and down arrow buttons can be used to adjust the surge speed. Zones can be selected or deselected when in the surge mode.
Chromatherapy Cycle (if provided) - Chromatherapy lights will automatically and continuously cycle through the eight colors; white, violet, indigo blue, aqua blue, green, yellow, orange and red. One cycle through all eight colors takes approximately one minute.
Chromatherapy Specific-Color (if provided) - When this mode is selected, you may choose a specific color for the bath.
Kohler Co. 5 1038265-5-B
User Keypad And Bath Modes/Features (cont.)
User Keypad “Sleep” Modes - To enhance your bathing experience, the keypad is programmed to darken after approximately 15 seconds of inactivity. Only the last feature selected will remain illuminated. To resume normal operation, press any key or turn the outer ring. Approximately 60 seconds after all equipment is turned off, the keypad will darken completely to conserve power. Press the power button or turn the outer ring to reactivate the keypad.
1038265-5-B 6 Kohler Co.
Air Flow Mode
Activates Mode Selected
Rotate Outer Ring to Access Desired Mode
Power On/Off
Zone 1
Zone 2
Zone 3
Surge Mode
Increase Flow or Surge
Indicator Bar
Chromatherapy Specific Color (if provided)
Decrease Flow or Surge
Chromatherapy Cycle (if provided)
Purge Mode
Operating Your Bath
Starting the Unit
If the unit does not function properly, please refer to the “Troubleshooting” section.
Close the drain.
Fill the bath to a level at least 2” (5.1 cm) above the top of the airjets. Use your hand to test the water temperature for comfort and safety. Carefully enter the bath basin. Press the On/Off button on the user keypad. Observe that the air system starts and air begins to flow to all zones. Observe that the chromatherapy lights (if provided) also begin operation in the cycling mode. If desired, adjust the air flow rate using the up button or the down button. After about 15 seconds, observe that only the last feature selected remains illuminated on the user
keypad.
Selecting Air Flow Modes
Rotate the outer ring to select a desired mode. Observe that the selected icon is flashing blue. Press the OKbutton to activate the mode. Observe that the active mode flashes green and the mode is implemented. Observe that, after about 15 seconds, the icon stops flashing. To turn off a mode, rotate the outer ring until the icon is flashing green and then press the “OK”
button again. The icon will then turn blue indicating the mode is off.
Stopping the Bath
When ready, press the power button a second time to stop the air system. Carefully exit the bath. Open the drain to empty the bath.
Kohler Co. 7 1038265-5-B
Operating Your Bath (cont.)
Observe that, when the bath drains below the level sensors, the automatic two-minute purge cycle occurs. The air system operates at a low speed to blow any residual water out of the air channels.
Observe that, about 60 seconds after shutdown, all user keypad lights extinguish.
Initiating a Manual Purge Cycle
After stopping the air system and draining the bath, rotate the ring on the user keypad to the purge icon.
Observe that the purge cycle icon is flashing blue. Press the OKbutton once. The purge icon flashes green and the mode is implemented. The air system operates at a low speed
to blow any residual water out of the air channels. After about two minutes, the air system stops automatically.
Chromatherapy Operation (if Equipped)
NOTE: Chromatherapy may be used with all modes of operation. Chromatherapy may also be used when the air system is not operating.
Chromatherapy Cycle - When this mode is activated, the chromatherapy lights automatically and continuously cycle through the eight colors: white, violet, indigo blue, aqua blue, green, yellow, orange, and red. One cycle through all eight colors takes about one minute. Rotate the outer ring to select this mode and press “OK” to activate it. To turn off the lights, press the “OK” button while the chromatherapy mode is selected and active.
Chromatherapy Specific Color Selection - When this mode is activated, you may choose a specific color for the bath. Rotate the outer ring to select this mode, press the “OK” button, and use the up/down buttons to reach the desired color. To turn off the lights, press the “OK” button while the chromatherapy mode is selected and active.
Care and Cleaning Instructions
Do not use powdered cleaners unless the cleaner is fully dissolved in water. Solid substances could block the airjets.
Do not use full strength bleach or ammonia cleaning solutions. Chemically active cleaning solutions can damage the bath surface.
Do not use abrasive cleansers or solvents on acrylic surfaces. Abrasive cleaners and solvents can damage the bath surface.
Wipe out your acrylic bath with a soft cloth after each use. Avoid detergents, disinfectants, or cleaning products in aerosol cans.
NOTE: To restore dull or scratched units: Apply white automotive polishing compound with a clean rag. Rub scratches and dull areas vigorously. Wipe off residue. Follow with a coat of white automotive paste wax. Do not wax areas where you walk or stand.
Cleaning Your User Keypad and Remote Control
Use a soft cloth to wipe the keypad and remote control after each use. If the surface becomes dirty, use a non-abrasive soap and warm water to clean.
Maintaining the Airjets
If cleaning the airjets is required due to hard water deposits, use a small between-the-teeth dental brush and white vinegar. Dip the brush in the vinegar, brush the hole, rinse the brush in clean water, and then use the wet rinsed brush to rinse the hole.
1038265-5-B 8 Kohler Co.
Care and Cleaning Instructions (cont.)
Fill the bath with water to the top row of airjets. Drain the bath and press the purge button.
For detailed cleaning information and products to consider, visit www.kohler.com/clean. To order Care & Cleaning information, call 1-800-456-4537.
Warranty
ONE-YEAR LIMITED WARRANTY
KOHLER plumbing products are warranted to be free of defects in material and workmanship for one year from date of installation.
Kohler Co. will, at its election, repair, replace or make appropriate adjustment where Kohler Co. inspection discloses any such defects occurring in normal usage within one (1) year after installation. Kohler Co. is not responsible for removal or installation costs. Use of in-tank toilet cleaners will void the warranty.
To obtain warranty service contact Kohler Co. either through your Dealer, Plumbing Contractor, Home Center or E-tailer, or by writing Kohler Co., Attn.: Customer Care Center, 444 Highland Drive, Kohler, WI 53044, USA, or by calling 1-800-4-KOHLER (1-800-456-4537) from within the USA and Canada, and 001-800-456-4537 from within Mexico, or visit www.kohler.com within the USA, www.ca.kohler.com from within Canada, or www.mx.kohler.com in Mexico.
IMPLIED WARRANTIES INCLUDING THAT OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. KOHLER CO. AND/OR SELLER DISCLAIM ANY LIABILITY FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states/provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state/province to state/province.
This is Kohler Co.’s exclusive written warranty.
Warranty
For Mexico
KOHLER CO. It is recommended that at the time of purchase, you verify that all accessories and components are complete
in this package. This Kohler product is warranted to be free of defects in material and workmanship for one (1) year from the
date of purchase as shown on the invoice or receipt.
1. Kohler Co. will only service its commercialized products through its authorized distributors.
2. To obtain warranty service, please present the invoice and corresponding warranty.
3. Through its authorized distributors, Kohler Co. promises to repair the defective product or provide a new replacement or an equivalent model (in those cases that the model has been discontinued) when the product is beyond repair, without any charge to the consumer.
4. The time of repair will not exceed six (6) weeks commencing on the date the product is received.
5. It is recommended that the consumer save the invoice or receipt as additional protection, as it may substitute the warranty in the case that there is a discrepancy in the validity of the warranty.
EXCEPTIONS AND RESTRICTIONS The Warranty will not be valid in the following cases:
1. When the product is not operated in accordance with the instructions concerning use and operation set forth in the owner’s manual or installation instructions, and when the recommendations and warnings included are not observed.
Kohler Co. 9 1038265-5-B
Warranty (cont.)
2. When the product has been modified or dismantled partially or totally; or has been used in a negligent fashion and as a consequence has suffered damages attributable to the consumer, individual, or hardware not authorized by Kohler Co.
3. This warranty does not cover the damages as a result of disaster such as fire or acts of God, including flooding, earthquake, or electric storms, etc. To obtain a list of distributors in your area where you can exercise your rights under this warranty, please call 001-800-456-4537.
KOHLER CO., KOHLER, WI 53044 U.S.A.
IMPORTER:
INTERNACIONAL DE CERÁMICA, S.A.B. DE C.V. AV. CARLOS PACHECO NO. 7200 CHIHUAHUA, CHIH., MEXICO C.P. 31060 TEL: 52 (14) 29-11-11
Troubleshooting Procedures
This troubleshooting guide is for general aid only. A Kohler Authorized Service Representative or qualified electrician should correct all electrical problems. For warranty service, contact your dealer or wholesale distributor.
Troubleshooting the Bath System
Symptoms Probable Causes Recommended Action
1. User keypad does not
illuminate when power button is pressed or the outer ring is rotated.
2. Ground-Fault
Circuit-Interrupter (GFCI) or Residual Current Device (RCD) trips when unit is turned on.
A. No power to control. A. Check wiring and connect power.
B. Ground-Fault Circuit-Interrupter
(GFCI) or Residual Current Device (RCD) tripped.
C. Wiring harness from user
keypad to control is loose, disconnected or damaged.
D. User keypad does not work. D. Replace the user keypad. Refer to
E. Control does not work. E. Replace the control. Refer to your
A. Electrical harness is wet or
damaged.
B. Electrical wiring to the junction
box is wet or damaged.
C. Electrical wiring to the power
cord is wet or damaged.
D. Blower motor does not work. D. Replace the blower motor. Refer to
B. Reset GFCI or RCD. If it trips
again, refer to Ground-Fault Circuit-Interrupter (GFCI) or Residual Current Device (RCD) trips when unit is turned on.
C. Check wiring for proper
connections. Replace the wiring harness if necessary. Refer to your installer or wholesale dealer.
your installer or wholesale dealer.
installer or wholesale dealer.
A. Check for wet connections. Dry the
connections and repair the leak. Check for insulation or connector damage. Replace the harness if damaged. Refer to your installer or wholesale dealer.
B. Have a qualified electrician
diagnose and correct the problem in accordance with applicable building and electrical codes.
C. Have a qualified electrician
diagnose and correct the problem in accordance with applicable building and electrical codes.
your installer or wholesale dealer.
1038265-5-B 10 Kohler Co.
Troubleshooting Procedures (cont.)
Symptoms Probable Causes Recommended Action
3. User keypad is
illuminated, but does not respond to buttons or outer ring.
4. Blower motor will not
start.
5. Blower motor stops
running and will not immediately restart. Keypad is illuminated.
6. Blower motor starts, some
but not all airjets are bubbling.
Blower motor runs but no
7.
air bubbles are formed.
E. Control does not work. E. Replace the control. Refer to your
A. Control program is locked. A. Reset GFCI or RCD.
B. P5 plug assembly harness from
user keypad to control is loose, disconnected, or damaged.
C. User keypad does not work. C. Replace the user keypad. Refer to
D. Control does not work. D. Replace the control. Refer to your
A. No water in the bath. A. Fill the bath at least 2(5 cm)
B. Power cord from blower motor
to control is loose, disconnected, or damaged.
C. Blower motor does not work. C. Replace the blower motor. Refer to
D. Control does not work. D. Replace the control. Refer to your
A. Blower motor overheated and
protection device activated.
A. Blower motor speed is too low. A. Increase speed setpoint to blower
B. Blower motor inlet is blocked. B. Clean blower motor inlet. C. Blower motor does not work. C. Replace the blower motor. Refer to
D. Blower motor discharge is
blocked.
E. Check valve does not work. E. Replace the check valve. Refer to
F. Airjets are clogged. F. Use a small between-the-teeth
A. Blower motor inlet is blocked. A. Clean blower motor inlet.
B. Airjets are clogged. B. Use a small between-the-teeth
C. Check valve does not work. C. Replace the check valve. Refer to
installer or wholesale dealer.
B. Check wiring for proper
connections. Replace the wiring harness if necessary. Refer to your installer or wholesale dealer.
your installer or wholesale dealer.
installer or wholesale dealer.
above the top of the highest air jet.
B. Check wiring for proper
connections.
your installer or wholesale dealer.
installer or wholesale dealer.
A. Check for blockage at motor vents.
Remove blockage and allow motor to cool. Refer to dealer or wholesale distributor. Otherwise, refer to User keypad is illuminated, but does not respond to buttons or outer ring.
motor.
your installer or wholesale dealer.
D. Check blockage.
your installer or wholesale dealer.
dental brush and white vinegar. Dip the brush in the vinegar, brush the hole, rinse the brush in clean water, and then use the wet rinsed brush to rinse the hole.
dental brush and white vinegar. Dip the brush in the vinegar, brush the hole, rinse the brush in clean water, and then use the wet rinsed brush to rinse the hole.
your installer or wholesale dealer.
Kohler Co. 11 1038265-5-B
Troubleshooting Procedures (cont.)
Symptoms Probable Causes Recommended Action
8. Blower motor operates,
air bubbles are formed, zone controls work, but variable speed feature does not work.
9. Blower motor won’t turn
off when the power button on user keypad is pressed.
10. A zone does not produce
air bubbles but another zone operates normally.
11. Surge mode does not
work.
12. Water spillage or damage
observed under the bath.
D. Blower motor does not work. D. Replace the blower motor. Refer to
E. Control does not work. E. Replace the control. Refer to your
A. Blower motor inlet is blocked. A. Clean blower motor inlet.
B. Loose, disconnected, or
damaged wiring harness.
C. User keypad does not work. C. Replace the user keypad. Refer to
D. Blower motor does not work. D. Replace the blower motor. Refer to
E. Control does not work. E. Replace the control. Refer to your
A. User keypad does not work. A. Replace the user keypad. Refer to
B. Loose, disconnected, or
damaged wiring harness.
C. Control does not work. C. Replace the control. Refer to your
A. Zone is not selected. A. Select the zone according to the
B. Butterfly valve does not work. B. Replace the butterfly valve. Refer
C. Loose, disconnected, or
damaged wiring harness.
D. User keypad does not work. D. Replace the user keypad. Refer to
E. Control does not work. E. Replace the control. Refer to your
A. User keypad does not work. A. Replace the user keypad. Refer to
B. Control does not work.
A. Drain or overflow leaking. A. Repair or replace the drain
B. Wall, deck, and/or shower door
is improperly sealed.
C. Cracked acrylic air channels. C. Refer to the manufacturer.
your installer or wholesale dealer.
installer or wholesale dealer.
B. Check wiring for proper
connections. Replace the wiring harness if necessary. Refer to your installer or wholesale dealer.
your installer or wholesale dealer.
your installer or wholesale dealer.
installer or wholesale dealer.
your installer or wholesale dealer.
B. Check wiring for proper
connections. Replace the wiring harness if necessary. Refer to your installer or wholesale dealer.
installer or wholesale dealer.
instructions in User Keypad and Bath with Airjets Modes/Features.
to your installer or wholesale dealer.
C. Check wiring for proper
connections. Replace the wiring harness if necessary. Refer to your installer or wholesale dealer.
your installer or wholesale dealer.
installer or wholesale dealer.
your installer or wholesale dealer.
B. Replace the control. Refer to your
installer or wholesale dealer.
assembly according to the manufacturer’s instructions.
B. Apply silicone sealant at the seams
between the bath and the wall, deck, or door.
1038265-5-B 12 Kohler Co.
Troubleshooting Procedures (cont.)
Symptoms Probable Causes Recommended Action
13. Noise level from pump
has increased and/or airjet performance has decreased.
A. The check valve is
malfunctioning.
B. The check valve needs to be
replaced.
A. Tap the check valve with a
screwdriver handle. Restart the system. If the symptoms have ceased, the check valve does not need to be replaced.
B. Remove the check valve from the
check valve assembly. Reassemble the check valve assembly without the check valve. Restart the system. If the system properly functions without the check valve, the check valve needs to be replaced. For safety, reinstall the malfunctioning check valve until a replacement check valve can be installed.
For Baths with Chromatherapy
Symptoms Probable Causes Recommended Action
14. Chromatherapy lights do
not work.
A. Loose, disconnected or damaged
wiring/connections.
B. Control does not work. B. Replace control. Refer to your
A. Check wiring for proper
connections. Replace wiring if necessary. Refer to your installer or wholesale dealer.
installer or wholesale dealer.
Kohler Co. 13 1038265-5-B
*Note:
All tubing 1" unless otherwise noted.
1-1/2" Tubing
1039601
Butterfly
1-1/4" Tubing
1-1/2" Tubing
**Finish/color code must be specified when ordering.
1036218
Check Valve Assembly
1-1/2" Tubing
95045
Screw
1038690
Vent Assembly
1-1/2" Tubing
1132320
Check Valve
95045
Screw
95045
Screw
58946
Screw
1035938
Washer
1036216
Blower Kit
Service Parts
1038265-5-B 14 Kohler Co.
93893
Cover
1033678
Screw
93892-A
Electrical Box
93841
Screw
61776
Lock Washer
67065
Ground Lug
93003
Strain Relief
60129
Nut
73519
Water Level Probe
63270
Washer
63270
Washer
1021777
Wire Harness
60129
Nut
1012821
Light Housing
61845-K
Grounding Wire
1010618
Elbow
Butterfly Valve
1016466
Motor
96956
Butterfly
63149
Screw
93836
(1/2")
93838
(1")
93839
(1-1/4")
94853
(1-1/2")
Tube (w/Couplings)
50506
Screw
1032507
Plug/Wire Assembly
1032583
Board
1032645
Control
1019933
Chromatherapy Lights
93841
Screw
1035939
Screw
1036872
Control Kit
1032509
Plug/Wire Assembly
1019447-B
Isolation Mount
**Finish/color code must be specified when ordering
Kohler Co. 15 1038265-5-B
Loading...
+ 33 hidden pages