Kodak LED II PRINTER 20R - SITE, RP 50 - SITE, PROFESSIONAL LED II 20P, PROFESSIONAL LED II 20R, PROFESSIONAL LED II PROCESSOR 20P Specifications

© Eastman Kodak Company, 2000
{SiteSp ecifications}{Production}{ KodakServiceSup port}
Publication No. SS2616-1
23NOV99
Supersedes SS2616-1
15JUL97
SITE SPECIFICATIONS
KODAK PROFESSIONAL LED II PRINTERS 20P/20R
KODAK PROFESSIONAL LED II PROCESSOR 20P
G130_1000HA
2 23NOV99 – SS2616-1
PLEASE NOTE The information containe d herein is based on the experience and knowledge relating to the
subject matter gained by Eastman Kodak Company prior to publication. No patent license is grante d by this information.
Eastman Kodak Company reserves the right to change this information without notice, and makes no warranty, express or implie d, with respect to this information. Kodak shall not be liable for any loss or damage, including consequential or special damages, resulting from any use of this information, even if loss or damage is caused by Kodak’s negligence or other fault .
Description Page
Table of Contents
Site Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Space Requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operating Environment
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Electrical Requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Plumbing Requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Venting Requirements
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Other
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Site Specifications
SS2616-1 – 23NOV99 3
Section 1: Site Specifications
Space Requirements
Dimens ions and Weight (Uncrated)
Site Access:
Doorways to the site should be 91centimetr es (36 inches) wide, or larger. The front and rear PRINTER FRAME DOORS, SHEET TRANSPORT MODULE DOORS, and the OPERATOR CONTROL PANEL (OCP) must be removed to move the PRINTER through a 36 inch doorway.
Minimum acceptable door size is 71.2 centimetres (28 inches). The enclosures, covers, and subassemblies for the
PAPER SUPPLY MODULE, the KNIFE AND SHEET TRANSPORT MODULE, and the TAKE-UP MODULE must be removed to move the PRINTER through a 28 inch doorway.
Roll-to-roll system only.
Operato r and Service Access:
When fully assembled, the sys tem requir es a minim um of 91 cm (36 in .) on each si de to a llow ac cess for se rvic e and operator maintenance .
Floor:
The system should be installed on a smooth, hard, and level floor surface. Floor pi tch should not exceed 1 inch in 5 feet.
Operating Environment
The unit to be installed is an Insul ation Catagor y Type II machi ne and operates in a Pollut ion Degree 2 environment in accordance with IEC 664 ( Normal Office Environment ).
* Room temperature changes of more than 5 degrees during operation will require recalibra tion of the PRINTER. **Although the PRINTER an d PROCES SOR operate in normal room lighting, access to a darkroom is required for
loading paper into cassettes.
Width Length Weight
Printer:
102 cm (40 in.)
149 cm (58.5 in.) 420 kg (925 lbs)
429 kg (945 lbs) with paper.
Processor:
87.6 cm (34.5 in.)
130 cm (51 in.) without removable print rack. 198 cm (78 in.) with print rack installed.
172 kg (380 lbs) 312 kg (471 lbs) with processing chemicals.
Roll-to-roll Printer:
102 cm (40 in.)
189 cm (74.5 in.) 510 kg (1125 lbs)
519 kg (1145 lbs) with paper.
Description Specification
Temperature* 15.5-26.6°C (60-80° F) for unplum bed
systems15.5-30° C (60-86° F) for plumbed
systems Relative Humidity 15-76% Altitude 0-2000 metres (6562 feet) Lighting maximum of 325 lux **
(30.2 foot-candles)