Publication Number. MA3211-M33
MODIFICATION INSTRUCTIONS
for the
KODAK MINILOADER 1
Service Codes 3211, 3212
MODIFICATION No. M33
Type 1 SELECTIVE
Issue number 2
PURPOSE:
To replace PCB 101A or PCB 101B with a modified PCB 101C to prevent the CONVEYOR BELT
running in reverse at the end of a cycle. The new PCB has a SOLID STATE RELAY to replace
TIMER T6. This modification replaces Modification M28.
IMPORTANT - The new PCB 101C cannot replace PCB 101, only PCB 101A & PCB 101B.
IMPORTANT: Only qualified service personnel should install this modification!
SERIAL NUMBERS: 1162 - 1412
Plus 1101 - 1161 with a serial number suffix M.
INSTALLATION TIME: Approximately 1 hour.
SPECIAL TOOLS: Test film.
PARTS REQUIREMENT: See Parts list.
PARTS AVAILABILITY: End of September 1992.
© Kodak Ltd. November 1992 MA 3211-33
1

PARTS LIST
PART NO. DESCRIPTION QUANTITY
30090033 MODIFICATION KIT 1
THE KIT CONTAINS:
30015981 PCB 101C 1
HTL 1217 STATIC SENSITIVE LABEL 1
MA3211-33 MODIFICATION INSTRUCTIONS 1
CA UTION
This equipment includes parts and assemblies sensitive to damage from electrostatic
discharge. Use caution to prevent damage during all service procedures.
PLEASE NOTE
The information contained herein is based on the experience and knowledge relating to the subject matter
gained by Kodak Limited prior to publication.
No patent license in granted by this information.
Kodak Limited reserves the right to change this information without notice, and makes no warranty,
express or implied, with respect to this information. Kodak shall not be liable for any loss or damage,
including consequential or special damages, resulting from the use of this information, even if the loss or
damage is caused by Kodak’s negligence or other fault.
MA 3211-33 November 1992
2
© Kodak Ltd.

MODIFICATION INSTRUCTIONS
1.
2.
3.
4.
Switch off the MINILOADER and remove the SUPPLY MAGAZINE and the ELECTRICAL
COVER.
Remove PCB 101A or PCB 101B (whichever is fitted) and replace it with PCB 101C. Re-pack
the old PCB in the ANTI-STATIC BAG and re-seal the BAG with the STATIC SENSITIVE
LABEL supplied in the MODIFICATION KIT. Tick the "UNFIT FOR STOCK" box and write
the SERIAL NUMBER of the MINILOADER on the LABEL. The old PCB must be returned to
your SPARES SERVICES DEPARTMENT.
Load the SUPPLY MAGAZINE with TEST FILM. Run some cycles to check the operation of
the MINILOADER. Check the settings of the TIMERS on PCB 101C. IMPORTANT, if the
MINILOADER is a PROCESSOR INTERFACE MODEL, do not forget to set TIMER T14 to
suit the processing cycle being used.
Replace all parts and circle M 33 on the MODIFICATION LABEL.
5.
© Kodak Ltd. November 1992 MA 3211-33
Use the normal procedure in your country to send the old PCB back to your SPARES
SERVICES so it can be modified. If the old PCB is not returned, with the SERIAL NUMBER
of the MINILOADER which it was removed from written on it, your country will not receive
credit for it.
3

HEALTH SCIENCES DIVISION
CUSTOMER EQUIPMENT SERVICES DIVISION, SWALLOWDALE LANE, HEMEL HEMPSTEAD, HERTFORDSHIRE, ENGLAND.
MA 3211-33 November 1992
4
© Kodak Ltd.