Kodak 7020, 9020, 9010, 7010 User Manual 2

KODAK EKTAPRO 7010/7020/9010/9020 Slide Projector

SUPPLEMENT TO THE MANUAL

©Eastman Kodak Company, 2000

Function Codes

This label is designed to be fixed on the rear of your IR Remote System (transmitter).
Function Code
• Dissolve times (0.1 - 9.9 s) CUT
Random Access 0-160
Fade: MASTER SLAVE
Alternate 777 Freeze 789
• Independent Projector Control Mode
• Parallel projection Focus Slave
• Reactivating dissolve mode
• Remote Security Mode
Reset 999 Autotimer
(1-60 s)
----- off
*
801 - 899 800
770 707
980
970 666*
990
989
601 - 660 600
* Function is inactivated for models
7010 and 9010!
5

Presentations with KODAK EKTAPRO 7010, 7020, 9010 and 9020 Slide Projectors

Oneoftheimportant newfeatures ofthe KODAKEKTAPRO 7010,7020, 9010and 9020Slide Projectorsis theintegrated dissolver for a 2-projector dissolve. You just have to link two projectors using the KODAK Dissolve Cable (accessory) and you can immediately run more interesting and lively live presentations using the infrared remotecontrol. It is also possible to play automatic slide shows with a fixed dissolve time. However, it is not
possible to record the IR-commands.
Projection with a single projector (Soft Slide Change)
If you are just presenting with a single EKTAPRO 7010, 7020, 9010or 9020, youcan fade yourslides out andback in again (e.g. bysetting a dissolve timeto smoothly change the slides). This means the hard light change is avoided during slide transport. The commands and notes which relate to the control of an individual projector are marked with an *.

Projection with two projectors

Choosing projectors (MASTER/SLAVE)
All commandsfor dissolving etc.are only transmittedto one projector. This projector is called the MASTER. It passes the commands onto the second projector which isknown as the SLAVE.
• You can use either the KODAK EKTAPRO 7010, 7020,
9010 or 9020 projector as a MASTER
• However, you can use all EKTAPRO models with a
P-Bus-in interface as a SLAVE!
Note: The use of all functions is only possible via EKTAPRO IR-Remote Control! With the KODAK EKTAPRO Cable Remote only dissolves in the default setting (0.5 sec) can be carried out.
Setting up
Putting your 2 projector dissolve systemtogether is fast and easy.Connect the twoprojectors viathe P-bus-ininterface to the KODAK Dissolve Cable (accessory) as shown in the illustration! Connect your remote control to the MASTER projector! Switch the projectors on. Your 2 projector dissolve system is now ready to use.
Comments
Evenwhen the two projectors are linkedwith the dissolve cable, theybehave like individual projectorsand can also be operated individually as usual via the keypad.
If your SLAVE projector has a built-in timer, it must be switched off!
If you want to use only one projector in single mode, simply switch off the SLAVE and use the MASTER!
Aligning the projectors
It is important to align the two slide projectors before beginning a presentation such that both projected images cover the same area. This is easiest using so-called aligning slides which your AV dealer will certainly carry in stock (it is useful to load the aligning slide in the tray compartment 80):
• Place the slide trays onto the projectors.
• Pressthe slide reverse transport buttonon both projectors.
• Focus both slides using the focus buttons on your projectors.
• Nowalign theprojectors toproject bothslides on the same area.
• Now return both slide trays to their initial position (zero position).
You can now begin your presentation using the remote control.
Comment (EKTAPRO 7010, 7020, 9010 or 9020)
If it is necessary to carry out any additional adjustment during the presentation push both transport buttons on the “dark” projector for longer than one second. The “dark” projector is now faded in too. Switch-off the lamp again by pressing standby.
Sorting slides into the slide trays
Once you have decided on the order of your slides, number them through. Then sort all the slides with uneven numbers in sequence into the slide tray for the MASTER projector. The slides with even numbers are sorted in order into the slide tray for the SLAVE projector (see the table page 34).
6

COMMANDS AND EFFECTS

Overview
The following table gives and overview of all commands andeffects. All commands with * can also be used for projection with a single EKTAPRO 7010, 7020, 9010 or 9020 Projector!
Function Code
* Setting dissolve times (Soft Slide Change in single projection)
* Random Access 0 - 160 Fade (MASTER) 770 Fade (SLAVE) 707 Alternate (Crossfading
without slide change) * Freeze 789 Independent Projector
Control Mode Parallel Projection Mode
Activate Focusfor SLAVE˚
Reactivatingof the dissolve mode
* Remote Security Mode 989 * Rest 999 * Auto-Timer 600 - 660
Function is inactivated for
˚
models 7010 and 9010!
Tip
801 - 899
777
980
970 666˚
990
• Thelast codeinput viathe numerical keypad of the IR remote control remains stored. If the command has to be reinput, it is only necessary to press the <*> key.
• If you input an incorrect figure on the numerical keypad of the IR remote control, press clear <C> before reinputting your figure.
DISSOLVE
Basic setting
After switching on you can immediately begin a dissolve presentation. Dissolving takes place with a default time of 0.5 seconds. As soon as you press the transport forwards button of the remote control both slidetrays go toposition 1 and the MASTER projector fades the no. 1 slide up at the specified time. If you push the button again the first dissolve happens: slide no. 1 is faded down in the specified time andat the same time slide 2 is automatically faded up.Then theslide trayof theMASTER projector is automatically transported one position further and the projector is ready for the next dissolve. The dissolve process also functions in the same way when youpush the transport backwards button.
Notes:
You can interrupt a presentation if the dissolve time is greater than one second. If a dissolve has already started, it can be interrupted by pressing the forward button again at lest 1 sec into the dissolve. The presentation will move on to the next slide. Continuously pressing the forward button will interrupt each dissolve after one second and move on to the next.
Dissolve times with IR remote control
You can input dissolve times of 0 seconds(so-called hard cut) up to a long dissolve of
9.9 seconds in increments of a tenth of a second.
The numerical combinations of 800 ...899 on your remote control are reservedfor this.Please ensurethat you press the ENTER button <*> after inputting the relevant combination. Only then is the command received by the projector and the time stored. As soon as you press the transport button on your remote control, the first dissolve takes place.
Examples:
If you want a dissolve time of
1 s : Input <810> and confirm with <*>.
5.5 s : Input <855> and confirm with <*>. 0 s (Hard Cut) : Input <800> and confirm
with <*>.
Important
The dissolve time you have input is retained until you overwrite it with a new time (via the IR remote control). After areset (switchingoff and backon again) the timeyou have input with the IR remote control is deleted (see Basic setting).
SELECTING SLIDES
As in the case ofindividual projection, you can transport backwards and forwards at will, or select slides directly (random access). The slide sequence is always retained and the projector which is currently “dark” is automatically carried to the next slide in your presentation.
7
*Random Access
Youselect slidesin 2projectordissolve according to the slide number of your presentation and not according to the slide tray number (see the table on page 34)!
Of course, if the slide you are looking foris in the slide tray of the projector which is currentlyprojecting a slide, a dissolveis
not possible. The slide will first be faded down and the new slide faded up. In this case, the screen will stay blank during the transport period. However, if the slide you are looking for is in the slide tray of the projector which is currently “dark”, it will dissolve with the slide you are currently projecting.
Zero compartment
If there is a slide in the zero compartment of the slide tray, this can be selected by entering the following:
161 for the MASTER projector; 0 for the SLAVE projector.
Note: it is not possible to dissolve from 0 to 161 or vice versa.
Note: (EKTAPRO 7010 and 9010)
If theslide tray (SLAVE)is transported on after a random access by pressing the transport buttons on the projector once or more, the previously selected slide cannot be accessed with a repeated random access command. (Example: on slide 36 with RA, transport forwards to slide 38, then back to slide 36 with RA cannot be done.)

Further control facilities

With the commands “Fade MASTER”, “Fade SLAVE” and
Alternate” you can carry out dissolves without a slide transport afterwards. When adissolve command follows this will be carried out via forward transport key on the next slide andwith the backwardtransport keyon the previous slide. Therefore it is guaranteed, that the synchronicity will also be maintained by individual lamp status. The fade in andout time will be that of the dissolve time last set. With these commands you also can changethe lampstatus ofthe projectors when operated in the parallel mode (code 970) or in the individual control mode (code 980), whereby the new lamp status will be kept by further transport or soft slide changes. This opens up interesting possibilities for your presentation.
FADE MASTER (770)
The MASTER projector's lamp can be faded in or faded out according to status. By re-pressing the button the command will be reversed.
Press <770> and <*> on your remote
control.
FADE SLAVE (707)
The SLAVE projector's lamp can be faded in or faded out according to status. By repressing the button the command will be reversed.
Press <707> <*> on your remote
control.
*ALTERNATE (Dissolve
without transport) (777)
With the Alternate command the existing lamp status can be changed (see chart).
Press <777> and <*> on your remote
control.
*FREEZE (789)
With the Freeze command a soft dissolve can be stopped at any time (resp. fade in and fade out by single projection) and in any position. The dissolve can be continued by pressing the forward transport key. With the backwards transport key you can fade back accordingly.
Press <789> and <*> on your remote
control.
Note: Mode switch-overs cannot be done in FREEZE. FREEZEcan onlybe releasedby pressingthe standby button or the transport buttons. If you release FREEZE by pressing the standby button, giving the standby command again will not return to FREEZE but will continue the dissolve.
With SoftSlide Change thelamp lights up whenFREEZE is endedby pressing the transportforwards button, andgoes dark if the transport backwards button is pressed. No slide transportis carried out. Special feature: You can use the transport buttons during the dissolve procedure to change the direction of dissolve more than once. Once the dissolve procedure has finished, however, the slide is not transported. This only happens the next time you press the transport button. Pressing it again continues your presentation as normal.

Further presentation features

INDIVIDUAL SLIDE TRANSPORT OF THE TWO PROJECTORS WITH REMOTE CONTROL (980)
With the number combination <980> and <*> you can control the transport of the two projectors individually with the remote control. If this code is transmitted, the dissolve mode is cancelled and the lamps of both projectors remain on. Soft slide change cannot be carried out in this mode.
Press <980> and <*> on your remote
control.
8
Transport control on the MASTER: The slide transport runs, as usual, via the two transport buttons. Transport control on the SLAVE: The slide transport isvia the two focus buttons. It is therefore not possible to focus the two projectors with this setting! Access to individual slides (RA control) is still possible (see *Random Access).
PARELLEL PROJECTION
(970)
You can also program parallel projections via your remote control.
Press <970> and <*>.
Both projectors will then move to the same slide tray setting and both lamps are switched on.
Focussing:
MASTER: With the focus buttons. SLAVE: First press <666> and <*>, then use focus buttons (not possible with models 7010 and 9010!). With a next slide transport this command is inactive again. The slides are numbered from 1 - 80 (or 1 - 140 on a 140 slide tray) in this parallel mode and can be selected as such.If, forexample, no. 13isselected, both projectors will go into search mode and project theslides in the slide tray slot no. 13.
BACK INTO DISSOLVEMODE
(990)
By inputting this combination of numbers and the <*> you can go back to a basic setting for the two projector dissolve. The dissolve time previously set is retained.
Press <990> and <*> on your remote
control.
*SECURITY SETTING FOR PRESENTATIONS USING IR REMOTE CONTROL (989)
If all the preparations for a presentation have been made, it is important for a presentation to run “smoothly”. In spite of the best preparation “small
hitches” can occur if the presenter presses thewrong button onthe remote control by accident.
With thesecurity settingyou can setup your remote control so that when the transport button is pressed, only one transport step or only one dissolve is executed. The focus buttons are also disabled so that if you happen to press the buttons, the focus on the projector is not changed. All other functions remain active (and can be secured by the cover on the remote control). Even novice presenters can now “not put a foot wrong”! This is how to put your remote control into the security position:
Press (989) and <*>.
The following functions are changed:
• Transport forwards: Regardless of how long you press a button, theprojector only carries out a single transport step or the next dissolve. Incase the parallelmode is activated the slides will only be projected if the button is released.
• Transport backwards: Holddown thebutton forat leasttwo seconds. The projector carries out a single step backwards and the slide will be projected in the moment the button is released.
• Focus: Inactive
Note:
Of course the security position can also be used to control projection with a single projector.
For the individual projector control (980) this command cannot be applied.
To cancel the security setting:
The presentation mode can only be cancelled by a reset command or by switching the projectors off and on again [see *RESET (999)].
Press (999) and <*>.
*RESET (999)
When youinput thiscommand, thetwo projectors are automatically reset to their zeroposition. Reset isthe same as switching the projectors off and back on again (see also Basic setting).
Press <999> and <*> on your remote
control.
*AUTOTIMER (600...660)
ATimer functioncan alsobe setvia the IR remote control. This is particularly relevant for theEKTAPRO 7010/7020 as this does not have a built-in timer. Any time from 1 to 6 seconds can be set (in steps of one second). If you transmit such a command to the MASTER projector, the first transport commandor the firstdissolve iscarried out immediately. This is a check for you that the projector is now in autotimer mode.
Example
Youwant a dissolve to takeplace every 22 seconds:
Press <622> and <*> on your remote control.
Theslide traygoes toposition 1and the first picture with the dissolve time is fadedup. Thefirst dissolveoccurs after 22 seconds.
Important
Whilst the MASTER projector is carrying out a slide transport, no commands should be sent with the IR remote control. This can lead to the command not being recognized, especially in the case of very short autotimer times. In this case the projector should be switched off- and on again.
Switching the autotimer off
You can turn theautotimer off again at any time:
Press <600> and <*> on your remote
control.
9

Slide Sorter Aid

Slide
Position
No.
0 0 41 21 82 41 123 62 1 1 42 21 83 42 124 62 2 1 43 22 84 42 125 63 3 2 44 22 85 43 126 63 4 2 45 23 86 43 127 64 5 3 46 23 87 44 128 64 6 3 47 24 88 44 129 65 7 4 48 24 89 45 130 65 8 4 49 25 90 45 131 66
9 5 50 25 91 46 132 66 10 5 51 26 92 46 133 67 11 6 52 26 93 47 134 67 12 6 53 27 94 47 135 68 13 7 54 27 95 48 136 68 14 7 55 28 96 48 137 69 15 8 56 28 97 49 138 69 16 8 57 29 98 49 139 70 17 9 58 29 99 50 140 70 18 9 59 30 100 50 141 71 19 10 60 30 101 51 142 71 20 10 61 31 102 51 143 72 21 11 62 31 103 52 144 72 22 11 63 32 104 52 145 73 23 12 64 32 105 53 146 73 24 12 65 33 106 53 147 74 25 13 66 33 107 54 148 74 26 13 67 34 108 54 149 75 27 14 68 34 109 55 150 75 28 14 69 35 110 55 151 76 29 15 70 35 111 56 152 76 30 15 71 36 112 56 153 77 31 16 72 36 113 57 154 77 32 16 73 37 114 57 155 78 33 17 74 37 115 58 156 78 34 17 75 38 116 58 157 79 35 18 76 38 117 59 158 79 36 18 77 39 118 59 159 80 37 19 78 39 119 60 160 80 38 19 79 40 120 60 161 0 39 20 80 40 121 61 40 20 81 41 122 61
in
MASTER
tray
Position
inSLAVE
tray
Slide
No.
Position
in
MASTER
tray
Position
inSLAVE
tray
Slide
No.
Position
in
MASTER
tray
Position
inSLAVE
tray
Slide
No.
Position
in
MASTER
tray
Position
inSLAVE
tray
34
10
Loading...