Klein Tools ET130 Instruction Manual

INSTRUCTION MANUAL
ET130
FRANÇAIS pg. 13
ESPAÑOL pg. 7
Light Meter
• MEASUREMENTS IN FOOT CANDLES (FC) AND LUX
• DATA HOLD
• MAX/MIN
• BACKLIT LCD SCREEN
ENGLISH
2
GENERAL SPECIFICATIONS
Klein Tools ET130 is an easy-to-use precision light meter that measures illuminance levels in both Foot Candles (FC) and Lux.
• Spectral Range: 400 to 760 nm; white light CIE standard
• Range: 0 to 4,000 FC; 0 to 40,000 Lux (1 FC = 10.76 Lux)
• Resolution: 0.01 FC / 0.1 Lux
• Repeatability: +/- 3%
• Accuracy: +/- 5% reading +/-10 digits @ <10,000 Lux
+/- 10% reading +/-10 digits @ >10,000 Lux
• Sample Rate: 2 times per second
• Sensor: Silicon photodiode with spectral response filter
• Battery: 9V
• Operating Altitude: 6562 ft. (2000 m)
• Relative Humidity: <80% non-condensing
• Operating Temp: 32° to 104°F (0° to 40°C)
• Storage Temp: 14° to 140°F (-10° to 60°C)
• Dimensions: 8.1" x 2.1" x 1.4" (206 x 54 x 36 mm)
• Weight: 5.5 oz. (156 g) including batteries
• Tripod Mount: 1/4-20 UNC
• Calibration: Accurate for one year
• Drop Protection: 3.3 ft. (1m)
Specifications subject to change.
WARNINGS
To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death.
• Read the instructions to ensure safe operation.
• Meter is NOT insulated. Avoid contact with areas where
energized conductive elements may be present.
• Always wear approved eye protection.
ENGLISH
3
FEATURE DETAILS
NOTE: There are no user-serviceable parts inside meter.
1.
Photodiode Sensor
6.
RANGE/FC/LUX Button
2.
3-3/4 Digit LCD Screen
7.
Backlight Button
3.
HOLD Button
8.
1/4-20 UNC Tripod Mount
4.
MAX/MIN Button
9.
Battery Cover
5.
Power Button
A.
Measurement
B.
Bar Graph
C.
Low Battery Indicator
D.
Units (FC/Lux)
E.
Function
(HOLD/MAX/MIN)
F.
Range (Auto/Manual)
G.
Auto Power-Off Icon
H.
Resolution (40/400/4K/40K)
LCD Display Detail
A
B
F
EGC
H D
1
2
3 4
7 6
5
8
9
Front of Meter Back of Meter
4
FUNCTION BUTTONS
ON/OFF
A short press of the Power Button 5 will power on and off the meter.
AUTO POWER-OFF
Auto Power-Off will automatically turn off the meter after 10 minutes of inactivity. When powered on, Auto Power-Off is enabled by default. A long press of the Power On/Off Button 5 for more than three seconds will disable the Auto Power-Off function, and the Auto Power-Off icon G will disappear from the display. A second long press will re-enable Auto Power-Off, and the Auto Power-Off icon will reappear.
BACKLIGHT
When powered on, the backlight is off by default. Press the Backlight button 7 to turn the backlight on or off. Backlight will remain on until it or the meter itself is turned off.
RANGE/FC/LUX
When powered on, the meter defaults to measuring in Foot Candles (FC). To switch to Lux, long-press the RANGE/FC/LUX button 6 for more than three seconds. A second long-press will switch back to FC. Note the Units icon D on the display.
Short presses of the RANGE/FC/LUX button will toggle the meter between Auto-ranging and Manual-ranging modes. Note the Range icon
F
on
the display.
• When in Lux mode, short-pressing will toggle (in order) between Auto, Manual (400), Manual (4k) and Manual (40k).
• When in Foot Candle (FC) mode, short-pressing will toggle (in order) between Auto, Manual (40), Manual (400) and Manual (4k).
Note the measurement resolution icon(s) H on the display when toggling between Manual modes.
DATA HOLD
Press the HOLD button 3 to hold the current measurement on the display. Press again to return to live measuring mode.
MAX/MIN
Short presses of the MAX/MIN button 4 will toggle (in order) between Maximum Value (MAX), Minimum Value (MIN) and Measurement mode.
ENGLISH
FEATURE DETAILS
SPECTRAL SENSITIVITY CHARACTERISTIC
The meter's spectral response aligns with the C.I.E. (International Commission of Illumination) standard.
400 450 500 550 600 650 700
1
0.8
0.6
0.4
0.2
0
RELATIVE
RESPONSE
WAVELENGTH (nm)
ET130 Response C.I.E. Response
5
OPERATING INSTRUCTIONS
1. Power on the meter, then use the RANGE/FC/LUX to select FC
or Lux and to select Auto or Manual range, as described in FUNCTION BUTTONS section.
2. If desired, press the backlight button to turn on the display
backlight, as described in FUNCTION BUTTONS section.
3. Face the photodiode sensor horizontal to the light source, and
read LCD display.
4. If desired, use the function buttons to select HOLD or
MAX/MIN, as described in FUNCTION BUTTONS section.
5. If desired, the meter can be mounted to any standard 1/4-20
tripod via the tripod mount 8 on the back of the unit.
LIGHTING TYPE CORRECTION FACTORS
The meter is calibrated under a standard tungsten light source of 2856°K. If the meter is to be used under a different type of light, the correction factors below should be applied for maximum accuracy:
Incandescent 1.00
Daylight uorescent
0.99
Daylight 1.00
Mercury Lamp
1.14
Metal Halide 1.00
Sodium Lamp
1.22
White uorescent 1.00
IES RECOMMENDED ILLUMINATION*
Location Lux FC
Ofce Conference Room 200-750 18-70
Office area 500-750 47-70 Lobbies, lounges 100-200 9-18
School Auditorium, Gymnasium 100-300 9-28
Class room 200-750 18-70 Library, Drafting, Laboratory 500-1500 47-140
Hospital Rooms 100-300 9-28
Emergency Room 500-1000 47-93 Operating Room 1000-2000 93-186
Factory Packing work 150-300 14-28
Parts assembly 1500 -3000 140-280 Inspection work 750-1500 70-140
Store Stairs, Corridor 150-200 14-18
Stockroom 100-300 9-28 Merchandising 750-1500 70-140
NOTE: 1 Foot Candle (FC) = 10.76 Lux
*The Lighting Handbook 10th Edition, Illuminating Engineering Society
6
ENGLISH
CLEANING
Be sure meter is turned off and wipe with a clean, dry lint-free cloth.
Do not use abrasive cleaners or solvents.
Remove the battery when the meter is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the meter to return to normal operating conditions before using.
WARRANTY
www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please see www.epa.gov or www.erecycle.org for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
customerservice@kleintools.com
www.kleintools.com
MAINTENANCE
BATTERY REPLACEMENT
When the indicator is displayed on the LCD, the battery must be replaced.
1. Remove screw
and remove battery door 9.
2. Remove and recycle
spent 9V battery.
3. Install new 9V battery.
4. Replace battery door and
fasten securely with screw.