ENGLISH
8.Non Contact Voltage (NCV): > 25V AC
SYMBOLS USED ON LCD
~ |
AC Measurement |
|
DC Measurement |
|
- |
Negative DC Value |
AT |
Auto Range Active |
|
O.L. |
Overload: Range Exceeded |
Apo |
Auto Power-Off Active |
|
|
Low Battery |
HOLD |
Hold Active |
|
MIN |
Minimum Reading |
MAX |
Maximum Reading |
|
% |
Duty Cycle Mode |
|
Frequency Mode |
|
V |
Voltage Measurement |
A |
Current in Amps |
|
Ω |
Resistance in Ohms |
|
Diode Test |
|
F |
Capacitance in Farads |
|
Continuity Test |
|
n |
Nano 10-9 |
µ |
Micro 10-6 |
|
m |
Milli 10-3 |
k |
Kilo 103 |
|
M |
Mega 106 |
|
|
|
|
|
ELECTRICAL SPECIFICATIONS |
||
DC Voltage Measurement |
|
|
||
Range |
|
Resolution |
Accuracy |
|
400mV ˜ 400V |
0.1mV ˜ 0.1V |
± (0.5% + 4 digits) |
||
1000V |
|
1V |
± (0.8% + 10 digits) |
|
Overload Protection: 1000V |
|
|
||
AC Voltage Measurement |
|
|
||
Range |
|
Resolution |
Accuracy |
|
400mV ˜ 750V |
0.1mV ˜ 1V |
± (2.0% + 5 digits) |
Overload Protection: 750V RMS
Frequency Response: 40 to 400 Hz
Minimum Voltage for Frequency Measurement: 200mV
Response: Averaging
DC Current Measurement |
|
||
Range |
Resolution |
Accuracy |
|
400µA |
0.1µA |
± (1.2% + 3 digits) |
|
2000µA |
1µA |
||
|
Overload Protection:
•Voltage: 600V RMS
•Current: 2000µA
AC Current Measurement |
|
|
|
Range |
Resolution |
Accuracy |
|
400µA |
0.1µA |
± (2.0% |
+ 5 digits) |
2000µA |
1µA |
± (1.5% |
+ 5 digits) |
40A |
0.01A |
± (2.9% |
+ 15 digits) |
400A |
0.1A |
± (1.9% |
+ 8 digits) |
Overload Protection:
•Voltage: 600V RMS
•Current: 2000µA Frequency: 45 to 400Hz
Minimum Current for Frequency Measurement: 400µA or 20A Response: Averaging
Resistance Measurement |
|
|
Range |
Resolution |
Accuracy |
400Ω ˜ 4MΩ |
0.1Ω ˜ 0.001MΩ |
± (1.0% + 4 digits) |
40MΩ |
0.01MΩ |
± (2.0% + 4 digits) |
Overload Protection: 600V RMS |
|
|
Capacitance Measurement |
|
|
Range |
Resolution |
Accuracy |
40nF ˜ 4000µF |
0.01nF ˜ 1µF |
± (3.5% + 6 digits) |
Overload Protection: 600V RMS |
|
|
|
Frequency Measurement |
|
|
|
Range |
Resolution |
Accuracy |
|
9.999Hz ˜ 999.9kHz |
0.001Hz ˜ 0.1kHz |
± (0.1% + 4 digits) |
|
Overload Protection: 600V RMS |
|
|
|
Duty Cycle Measurement |
|
|
|
Range |
Resolution |
Accuracy |
|
0.1 ˜ 99.9% |
0.1% |
± (0.2% per kHz + 0.1% + 5 digits) |
|
Overload Protection: 600V RMS |
|
|
|
Diode Test |
|
|
|
Overload Protection Range |
Test Current |
Open Circuit Voltage |
|
600V RMS |
2.0V |
Appx. 0.25mA |
< 1.6V DC |
Continuity Test |
|
|
|
Overload Protection |
Open Circuit Voltage |
||
600V RMS |
|
< 0.44V |
|
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
WARRANTY www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it.
DISPOSAL / RECYCLE
Caution: This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
www.kleintools.com
CL1000
Instruction Manual
ENGLISH
•AUTO /MANUAL RANGE
•NON CONTACT VOLTAGE TESTER
•DATA HOLD
•MAX / MIN
•BAR GRAPH
•3-3/4 DIGIT
3999 COUNT LCD
•BACKLIGHT
•WORKLIGHT
750V
1000V
400A
600V |
CATIII |
400A |
|
|
CL1000
|
|
|
|
V |
AT |
|
|
|
|
Apo |
|
|
|
|
0 |
10 |
20 |
30 |
40 |
139537T Rev. 11/13 B