8.Non Contact Voltage (NCV): > 25V AC

SYMBOLS USED ON LCD

~

AC Measurement

 

DC Measurement

-

Negative DC Value

AT

Auto Range Active

O.L.

Overload: Range Exceeded

Apo

Auto Power-Off Active

 

Low Battery

HOLD

Hold Active

MIN

Minimum Reading

MAX

Maximum Reading

%

Duty Cycle Mode

 

Frequency Mode

V

Voltage Measurement

A

Current in Amps

Ω

Resistance in Ohms

 

Diode Test

F

Capacitance in Farads

 

Continuity Test

n

Nano 10-9

µ

Micro 10-6

m

Milli 10-3

k

Kilo 103

M

Mega 106

 

 

 

 

ELECTRICAL SPECIFICATIONS

DC Voltage Measurement

 

 

Range

 

Resolution

Accuracy

 

400mV ˜ 400V

0.1mV ˜ 0.1V

± (0.5% + 4 digits)

1000V

 

1V

± (0.8% + 10 digits)

Overload Protection: 1000V

 

 

AC Voltage Measurement

 

 

Range

 

Resolution

Accuracy

 

400mV ˜ 750V

0.1mV ˜ 1V

± (2.0% + 5 digits)

Overload Protection: 750V RMS

Frequency Response: 40 to 400 Hz

Minimum Voltage for Frequency Measurement: 200mV

Response: Averaging

DC Current Measurement

 

Range

Resolution

Accuracy

400µA

0.1µA

± (1.2% + 3 digits)

2000µA

1µA

 

Overload Protection:

Voltage: 600V RMS

Current: 2000µA

AC Current Measurement

 

 

Range

Resolution

Accuracy

400µA

0.1µA

± (2.0%

+ 5 digits)

2000µA

1µA

± (1.5%

+ 5 digits)

40A

0.01A

± (2.9%

+ 15 digits)

400A

0.1A

± (1.9%

+ 8 digits)

Overload Protection:

Voltage: 600V RMS

Current: 2000µA Frequency: 45 to 400Hz

Minimum Current for Frequency Measurement: 400µA or 20A Response: Averaging

Resistance Measurement

 

Range

Resolution

Accuracy

400Ω ˜ 4MΩ

0.1Ω ˜ 0.001MΩ

± (1.0% + 4 digits)

40MΩ

0.01MΩ

± (2.0% + 4 digits)

Overload Protection: 600V RMS

 

Capacitance Measurement

 

Range

Resolution

Accuracy

40nF ˜ 4000µF

0.01nF ˜ 1µF

± (3.5% + 6 digits)

Overload Protection: 600V RMS

 

 

Frequency Measurement

 

 

Range

Resolution

Accuracy

9.999Hz ˜ 999.9kHz

0.001Hz ˜ 0.1kHz

± (0.1% + 4 digits)

Overload Protection: 600V RMS

 

 

Duty Cycle Measurement

 

 

Range

Resolution

Accuracy

 

0.1 ˜ 99.9%

0.1%

± (0.2% per kHz + 0.1% + 5 digits)

Overload Protection: 600V RMS

 

 

Diode Test

 

 

 

Overload Protection Range

Test Current

Open Circuit Voltage

600V RMS

2.0V

Appx. 0.25mA

< 1.6V DC

Continuity Test

 

 

 

Overload Protection

Open Circuit Voltage

600V RMS

 

< 0.44V

 

Non Contact Voltage Detector

On Voltage

Appx. 25V AC

WARRANTY www.kleintools.com/warranty

CLEANING

Turn instrument off and disconnect test leads. Clean the instrument by using a damp cloth. Do not use abrasive cleaners or solvents.

STORAGE

Remove the batteries when instrument is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the Specifications section, allow the instrument to return to normal operating conditions before using it.

DISPOSAL / RECYCLE

Caution: This symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal.

CUSTOMER SERVICE

KLEIN TOOLS, INC.

450 Bond Street

Lincolnshire, IL 60069

www.kleintools.com

CL1000

Instruction Manual

ENGLISH

AUTO /MANUAL RANGE

NON CONTACT VOLTAGE TESTER

DATA HOLD

MAX / MIN

BAR GRAPH

3-3/4 DIGIT

3999 COUNT LCD

BACKLIGHT

WORKLIGHT

750V

1000V

400A

600V

CATIII

400A

 

 

CL1000

 

 

 

 

V

AT

 

 

 

 

Apo

 

 

 

 

0

10

20

30

40

139537T Rev. 11/13 B