Klaxon Nexus 110 Low Voltage Installation Instruction

Nexus110
1. Technical Specification: Low Voltage AC Sounder
Supply Voltage Range 20-53V AC, 50/60Hz Current 10-50mA* (Typ. 45mA @ 24V, Tone 1) Peak Sound Level: 104-116 dBA at 1m* (Typ. 110dBA @ 24V, Tone 1) Number of Tones: 64 Frequency Range 340-2900 Hz* Volume Control 20dBA typical Remote Tone Switching Provision for 3 volt-free contact activated alarm stages Operating Temperature: - 25°C to +55°C Casing: High Impact Polycarbonate/ABS IP Rating: IP66 with suitable cable glands Synchronisation Automatic with Klaxon Nexus and Sonos Sounders
*depends on selected tone and supply voltage
2. Installation
a. The sounder is installed by first mounting the base unit and making the external wring connections to
the base. The head unit then automatically connects when it is attached to the base.
b. The sounder head is separated from the base by unlocking the four ¼-turn fasteners in the corners of
the sounder. (Recommended screwdriver: Philips No. 2, min 100mm long).
c. Note that the head only fits onto the base one way around.
3. Wiring
4. Controls
a. Power
Device Common (Neutral) 20-50V AC
Sounder
AC1 AC2
Each power terminal is duplicated to enable simple ‘daisy-chain’ connection of multiple units
b. Remote Tone Switching (If required): Externally link control terminals as shown below.
Alarm Stage Example Signal Activation
Stage 1 ‘Alert’ No connection (Default) Stage 2 ‘Evacuate’ Stage 3 ‘All Clear’
Link terminal Link terminal
to terminal
to terminal
a. Tone Selection
m
The first and second stage alarm tones are independently set using 6-way dipswitches S1 and S2 respectively. The required settings are shown in the table overleaf. The third stage alarm tone is pre-set to complement the selected first stage tone as shown in the table.
j
b. Volume Control
y
The sound output of the unit can be reduced by up to 20dBA by adjusting the potentiometer. At low sound levels the sound may take a few seconds to decay away after power is removed from the sounder.
18-186508/4
1H[XV/RZ 9ROWD J H $& Tone Table
TONE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
34.
35.
36.
37.
38.
39.
40.
41.
42.
43.
44.
45.
46.
47.
48.
49.
50.
51.
52.
53.
54.
55.
56.
57.
58.
59.
60.
61. Power Only – Use with Stage 3 control for manual/intermittent chime triggering
62. Power Only – Use with Stage 3 control for manual/intermittent chime triggering
63. Power Only – Use with Stage 3 control for manual/intermittent horn triggering
64. Reserved for future use
TONE
TYPE
970Hz (BS5839-1:2002) 800Hz/970Hz @ 2Hz (BS5839-1:2002) 800Hz – 970Hz @ 1Hz (BS5839-1:2002) 970Hz 1s OFF/1s ON (Apollo Fire Systems Alert Tone, BS5839-1:2002)
970Hz, 0.5s/ 630Hz, 0.5s (Apollo Fire Systems Evacuate Tone, BS5839-
1:2002) 554Hz, 0.1s/ 440Hz, 0.4s (France – AFNOR NF S 32 001 ) 500 – 1200Hz, 3.5s/ 0.5s OFF (Netherlands – NEN 2575:2000) 420Hz 0.625s ON/0.625s OFF (Australia AS1670 Alert tone)
500 – 1200Hz, 0.5s/ 0.5s OFF x 3/1.5s OFF (Australia AS1670 Evacuation
tone) 550Hz/440Hz @ 0.5Hz 970Hz, 0.5s ON/0.5s OFF x 3/ 1.5s OFF (ISO 8201 Low tone) 2850Hz, 0.5s ON/0.5s OFF x 3/1.5s OFF (ISO 8201 High tone) 1200Hz – 500Hz @ 1Hz (DIN 33 404) 400Hz 550Hz, 0.7s/1000Hz, 0.33s 1500Hz – 2700Hz @ 3Hz (Vandal Alarm)
Simulated Bell 2130Hz 660Hz 660Hz 1.8s ON/1.8s OFF 660Hz 0.15s ON/0.15s OFF 510Hz, 0.25s/ 610Hz, 0.25s 800/1000Hz 0.5s each (1Hz) 250Hz – 1200Hz @ 12Hz 500Hz – 1200Hz @ 0.33Hz. 2400Hz – 2900Hz @ 9Hz 2400Hz – 2900Hz @ 3Hz 800Hz – 970Hz @ 100Hz 800Hz – 970Hz @ 9Hz 800Hz – 970Hz @ 3Hz 800Hz, 0.25s ON/1s OFF 500Hz – 1200Hz, 3.75s/0.25s OFF (AS2220) 340Hz 1000Hz 1400Hz – 1600Hz, 1s/1600Hz – 1400Hz, 0.5s (NF 48-265) 660Hz 6.5s ON/13s OFF 1000Hz/2000Hz, 1s each 720Hz, 0.7s ON/0.3s OFF 970Hz, 0.25s ON/OFF 2800Hz, 1s ON/OFF 2800Hz 0.25s ON/OFF 2400/2900 @ 2Hz Chime, 554Hz/440Hz Single shot ‘ding dong’ Chime, 554Hz/440Hz Repeating ‘ding dong’ Chime, 970Hz/800Hz Single shot ‘ding dong’ Chime, 970Hz/800Hz Repeating ‘ding dong’ Hooter, Repeating Gentle alarm - Tone 2, rises slowly to full volume over 30s Time-Out Alarm – As Tone 2, cuts off after 10 mins Time-Out Alarm – As Tone 2, cuts off after 2 mins 750Hz 0.33s ON/0.51s OFF 750Hz 0.51s ON/0.33s OFF 550Hz, 0.33s/1000Hz, 0.7s 600Hz – 900Hz/ 0.9s 660Hz – 680Hz/ 0.9s 670Hz – 725Hz/ 0.9s 920Hz – 750Hz/ 0.9s 700Hz - 900Hz, 0.3s/0.6s OFF 900Hz - 760Hz, 0.6s/0.3s OFF 750Hz
TONE DESCRIPTION/ APPLICATION
DIP SWITCH
(S1/S2)
1_2_3_4_5_6
O-O-O-O-O-O O-O-O-O-O-I O-O-O-O-I-O O-O-O-O-I-I
O-O-O-I-O-O O-O-O-I-O-I O-O-O-I-I-O O-O-O-I-I-I
O-O-I-O-O-O O-O-I-O-O-I O-O-I-O-I-O O-O-I-O-I-I O-O-I-I-O-O O-O-I-I-O-I O-O-I-I-I-O O-O-I-I-I-I O-I-O-O-O-O O-I-O-O-O-I O-I-O-O-I-O O-I-O-O-I-I O-I-O-I-O-O O-I-O-I-O-I O-I-O-I-I-O O-I-O-I-I-I O-I-I-O-O-O O-I-I-O-O-I O-I-I-O-I-O O-I-I-O-I-I O-I-I-I-O-O O-I-I-I-O-I O-I-I-I-I-O O-I-I-I-I-I I-O-O-O-O-O I-O-O-O-O-I I-O-O-O-I-O I-O-O-O-I-I I-O-O-I-O-O I-O-O-I-O-I I-O-O-I-I-O I-O-O-I-I-I I-O-I-O-O-O I-O-I-O-O-I I-O-I-O-I-O I-O-I-O-I-I I-O-I-I-O-O I-O-I-I-O-I I-O-I-I-I-O I-O-I-I-I-I I-I-O-O-O-O I-I-O-O-O-I I-I-O-O-I-O I-I-O-O-I-I I-I-O-I-O-O I-I-O-I-O-I I-I-O-I-I-O I-I-O-I-I-I I-I-I-O-O-O I-I-I-O-O-I I-I-I-O-I-O I-I-I-O-I-I I-I-I-I-O-O I-I-I-I-O-I I-I-I-I-I-O I-I-I-I-I-I
Klaxon Signals Ltd Wrigley St., Oldham, OL4 1HW Telephone: Sales - 0161 287 5555 Technical Support - 0161 287 4029 Fax: 0161 287 5511 E-Mail: sales@klaxonsignals.com Web:www.klaxonsignals.com
3rd
STAGE
TONE
18
1 1 1
1 1
1 1
1
19
1 1 1
18
1 1 1
1 10 19 19
1
1
1
1
1
1
1
1
1
1
1
1 18
1 19
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1 18 43 43 47
PEAK SOUND
LEVEL
(dBA @ 1m)
110 110 110 110
110 107 110 105
110 107 110 112 110 105 111 116 112 113 109 108 107 107 111 105 110 116 116 110 110 110 108 110 106 111 110 108 113 106 110 113 113 115 104 107 106 106 107 109 44 109 44 109 44 106 107 111 109 105 107 110 109 110 107
SOUNDER CURRENT
(mA AVG)
45 44 43 25
39 24
28
9 13 26
19 16 34 21 33 46 26 34 31 16 17 28 44 24 31 45 45 42 43 43 10 29 18 47 44 31 41 26 25 22 21 43 15 15 36 36 13
12 25 41 37 33 33 41 15 28 39
Loading...