KitchenAid KOWT100ESS00, KOWT104ESS00, KOWT107ESS00 Installation Guide

INSTALLATIONINSTRUCTIONS
24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM)
INDOOR/OUTDOOR ELECTRICWARMING DRAWER
INSTRUCTIONSD'INSTALLATION
TIROIR-RECHAUDELECTRIQUEPOURUSAGE
INTI_RIEUR/EXTI:RIEURDE24" (61 CM),
27" (68,6 CM), ET30" (76,2 CM)
TableofContents/Table des mati@res
Tools and Parts ............................................................................ 3
Location Requirements ................................................................ 3
Electrical Requirements ............................................................... 6
Install Warming Drawer ................................................................ 6
Complete Installation ................................................................... 7
CUSTOM DRAWER FRONT INSTALLATION
Tools and Parts ............................................................................ 7
Install Custom Drawer Front Panel .............................................. 7
EXIGENCES D'INSTALLATION ................................................... 10
Outillage et pieces ...................................................................... 10
Exigences d'emplacement ......................................................... 10
Specifications electriques .......................................................... 13
INSTRUCTIONS D'INSTALLATION ............................................. 13
Installation du tiroir-rechaud ...................................................... 13
Achever I'installation .................................................................. 14
INSTRUCTIONS D'INSTALLATION DE LA FAQADE
DU TIROIR PERSONNALISI_ POUR TIROIR-RECHAUD .......... 14
Outillage et pieces ...................................................................... 14
Installation du panneau de la fa£;ade du tiroir personnalise ......14
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT :
,&,conserver pour consultation par I'inspecteur local des installations 61ectriques.
W10713339A
WARMING DRAWERSAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
2
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools Needed
Phillips screwdriver
Flat-blade screwdriver
Measuring tape
Level
Drill
13/8"(3.5 cm) hole saw
Parts Supplied
Two#8-18 x 1/2"screws
Lens (for panel ready models) Check local codes. Check existing electrical supply. See
"Electrical Requirements." It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
IMPORTANT: Observe all governing codes and ordinances.
Cutout dimensions that are shown must be used. Given dimensions provide minimum clearance with warming drawer.
Recessed installation area must provide complete enclosure around the recessed portion of the warming drawer.
Grounded electrical supply is required. See "Electrical Requirements" section.
Electrical supply outlet should be located in the rear wall on the upper right-hand side of the cutout or in an adjacent
cabinet. The outlet must be recessed. If the electrical outlet is located in an adjacent cabinet, a 13/8"(3.5 cm) minimum
diameter hole should have been drilled in the back of the cutout or support surface to pass the power supply cord
through to the outlet.
Warming drawer support surface must be solid, level and flush with bottom of cabinet cutout.
Warming drawers with oiled bronze, black glass, and white glass panels are approved for indoor use only.
Support surface must be solid, level, and flush with the bottom of the cabinet cutout.
24" (61 cm) minimum cabinet depth.
For best performance results make sure the warming drawer is leveled before completing installation. There is no way to level the warming drawer after it has been installed. If the installation is not
level, the door may slide open or not seal tightly, allowing heat to escape.
NOTE: If installing the warming drawer below another product, refer to that product's literature for any installation requirements.
Product Dimensions
E
/ _--------______
WARMING OVEN RECESSED RECESSED OVERALL DRAWER
DRAWER DEPTH (A) WIDTH (B) HEIGHT (C) WIDTH (D) FRONT
SIZE HEIGHT (E)
24" 231/8" 221/4'' 9" 233/4" 101/4"
(61 cm) (58.7 cm) (56.5 cm) (22.9 cm) (60.3 cm) (26.1 cm)
27" 231/8'' 25%" 9" 263/4'' 101/4'' (68.6 cm) (58.7 cm) (64.1 cm) (22.9 cm) (67.9 cm) (26.1 cm)
30" 231/8" 28%" 9" 293/4" 101/4" (76.2 cm) (58.7 cm) (71.8 cm) (22.9 cm) (75.6 cm) (26.1 cm)
Clearance Dimensions
120 vomt grounded
outlet (or located
in adjacent
cabinet)
Warming
drawer
Toe
A
B
A
-r-
B
±
c
__t_
WARMING MINIMUM CUTOUT MINIMUM/ CUTOUT MINIMUM DRAWER SIZE BETWEEN HEIGHT (B) RECOMMENDED (C) WIDTH (D) CABINET
CUTOUTS (A) WIDTH (E)
24" (61 cm) 21/2'' (6.4 cm) 91/8"(23.2 cm) 1" (2.5 cm)/ 221/2'' (57.1 cm) 24" (61 cm)
27" (68.6 cm) 21/2"(6.4 cm) 91/8'' (23.2 cm) 1" (2.5 cm)/ 251/2"(64.8 cm) 27" (68.6 cm)
30" (76.2 cm) 21/2"(6.4 cm) 91/8'' (23.2 cm) 1" (2.5 cm)/ 281/2"(72.4 cm) 30" (76.2 cm)
Warming drawer can be installed as an indoor single or double installation or installed under asingle oven. Two warming drawers under a single oven are shown.
NOTE: The warming drawer cannot be leveled after being installed.
For outdoor installation, follow the cutout dimensions above. Install the outdoor warming drawer in a permanent fixture.
41/4'' (10.8 cm)
41/4'' (10.8 cm)
41/4"(10.8 cm)
Custom Wood Drawer Front If you plan to install a custom wood panel to match your
cabinets, we recommend consulting a qualified cabinetmaker or carpenter. The back of the wood panel must be sealed to avoid moisture damage.
Clearance Dimensions - Flush Installation
Front View
Side View
[
Top View
--'B
- E
]
E
q_J" 15/8.(4.1o_)
m
27" Models 30" Models
Side Cleat* --
t
7/J(22mm)
f_ Platform*
1" (25mm) r--]/
_SIde Cleats*-_
[ ]
A Width of flush inset cutout (minimum) 271/4'' (69.2 cm) 301/4'' (76.8 cm)
B Height between cutouts (minimum) 21/2'' (6.4 cm) 21/2'' (6.4 cm)
C Height of flush inset cutout (minimum) 103/4'' (27.3 cm) 103/4'' (27.3 cm)
Bottom of cutout to floor (recommended) 81/4'' (21.0 cm) 81/4'' (21.0 cm)
D
Bottom of cutout to floor (minimum) 5" (12.7 cm) 5" (12.7 cm) E Width of opening (minimum) 251/4'' (64.1 cm) 281/4'' (71.8 cm) F Depth of cutout (minimum) 253/8'' (64.5 cm) 253/8'' (64.5 cm)
e Recommended outlet location
Cabinet
Back
Flush Installation Requirements
A 25%" (64.5 cm) minimum cutout depth is required. These dimensions will result in a 1/4"(6 ram) reveal on all sides of the warming drawer. The front face of the cleats and platforms will be visible and should be treated as a finished surface.
Loading...
+ 11 hidden pages