Kern FKB 15K0.5A, FKB 15K1A, FKB 30K1A, FKB 30K2A, FKB 60K2A User guide

...
KERN & Sohn GmbH
Ziegelei 1 D-72336 Balingen E-Mail: info@kern-sohn.com
KERN FKB_A
Version 1.1 07/2007
GB
Tel: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com
FKB_A-BA-e-0711
GB
KERN FKB_A
Version 1.1 07/2007
Operating instruction Compact balance
Table of Contents
1 Technical data__________________________________________________ 4 2 Declaration of conformity ________________________________________ 6 3 Basic Information (General)_______________________________________ 7
3.1 Proper use _________________________________________________ 7
3.2 Improper Use _______________________________________________ 7
3.3 Warranty___________________________________________________ 7
3.4 Monitoring of Test Resources _________________________________ 8
4 Basic Safety Precautions_________________________________________ 8
4.1 Pay attention to the instructions in the Operation Manual __________ 8
4.2 Personnel training___________________________________________ 8
5 Transport and storage ___________________________________________ 8
5.1 Testing upon acceptance _____________________________________ 8
5.2 Packaging__________________________________________________ 8
6 Unpacking, Setup and Commissioning _____________________________ 9
6.1 Installation Site, Location of Use_______________________________ 9
6.2 Unpacking _________________________________________________
9
6.2.1 Setup ____________________________________________________ 9
6.2.2 Scope of delivery __________________________________________
10
6.2.3 Basic structure ____________________________________________ 10
6.3 Mains connection __________________________________________ 10
6.4 Operation using a (rechargeable) battery (optional) ______________
6.5 Connection of peripheral devices _____________________________
10 11
6.6 Initial Commissioning _______________________________________ 11
6.7 Adjustment________________________________________________ 11
6.8 Adjustment________________________________________________ 12
6.9 Underfloor weighing ________________________________________
7 Operation_____________________________________________________
13
14
7.1 Overview of display_________________________________________ 14
7.2 Weighing__________________________________________________ 14
2
FKB_A-BA-e-0711
7.3 Taring ____________________________________________________ 15
7.4 PRE-Tare function __________________________________________ 15
7.5 Plus/minus weighings_______________________________________ 15
7.6 Parts counting _____________________________________________ 16
7.7 Net-total weighings _________________________________________ 17
7.8 Percent weighings__________________________________________ 17
7.9 Weighing units (Unit)________________________________________ 18
7.10 Display background illumination______________________________
7.11 Animal weighing function____________________________________
20 21
7.12 Default setting _____________________________________________ 22
8 Settings ______________________________________________________ 23
8.1 Menu structure: ____________________________________________ 23
8.2 Leave menu structure _______________________________________
8.3 Dosing and Zero-tracking____________________________________
24 24
8.4 Selection of the adjustment weight ____________________________ 25
8.5 Interface RS232C___________________________________________ 26
8.5.1 Data transfer mode ________________________________________ 26
8.5.2 Baud rate ________________________________________________ 26
8.6 Selection printed edition_____________________________________ 27
9 Data output RS 232 C ___________________________________________ 28
9.1 Technical data _____________________________________________ 28
9.2 Pin allocation of the balance output socket (front view), __________
28
9.3 Explanation of the data transfer _______________________________ 28
9.3.1 Pr PC ___________________________________________________
28
9.3.2 AU Pr___________________________________________________ 28
9.3.3 AU PC__________________________________________________
9.3.4 rE Cr ___________________________________________________
29 29
9.4 Output on bar code printer___________________________________ 30
10 Service, maintenance, disposal_________________________________ 31
10.1 Cleaning __________________________________________________ 31
10.2 Service, maintenance _______________________________________ 31
10.3 Disposal __________________________________________________ 31
11 Instant help _________________________________________________ 32
FKB_A-BA-e-0711
3

1 Technical data

KERN FKB 15K0.5A FKB 15K1A FKB 30K1A
Readability (d) 0.5 g 1 g 1 g Weighing range (max) (d) 15 kg 15 kg 30 kg Taring range (subtractive) 15 kg 15 kg 30 kg Reproducibility 0.5 g 1 g 1 g Linearity 1.5 g 3 g 3 g Minimum unit weight at
piece counting Warm-up time 2 hours 30 minutes 2 hours Reference quantities at
piece counting Weighing Units Recommended adjustment weight,
not added (class) Details for „Selection of the
Adjustment weight“ in chapter
8.4 Stabilization time (typical) 3 sec. Operating temperature +5°C….. + 35° C Humidity of air max. 80 % (not condensing)
1 g 2 g 2 g
5, 10, 25, 50
Details „Weighing units“ chapter 7.9
15 kg
(F2)
15 kg
( M1 )
30 kg
(F2)
Housing (B x D x H) mm 350 x 390 x 120 Weighing plate mm 340 x 240 Weight kg (net) 6.5
4
FKB_A-BA-e-0711
KERN FKB 30K2A FKB 60K2A FKB 60K5A
Readability (d) 2 g 2 g 5 g Weighing range (max) (d) 30 kg 60 kg 60 kg Taring range (subtractive) 30 kg 60 kg 60 kg Reproducibility 2 g 2 g 5 g Linearity 6 g 6 g 15 g Minimum unit weight at piece
counting Warm-up time 30 minutes 2 hours 30 minutes Reference quantities at
piece counting Weighing Units Recommended adjustment weight,
not added (class) Details for „Selection of the
Adjustment weight“ in chapter
8.4 Stabilization time (typical) 3 sec. Operating temperature +5°C... + 35° C Humidity of air max. 80 % (not condensing)
4 g 4 g 10 g
5, 10, 25, 50
Details „Weighing units“ chapter 7.9
30 kg
( M1 )
60 kg
(F2)
60 kg
( M1 )
Housing (B x D x H) mm 350 x 390 x 120 Weighing plate mm 340 x 240 Weight kg (net) 6.5
FKB_A-BA-e-0711
5

2 Declaration of conformity

Declaration of conformity
The electronic balances
fulfill the requirements of the following CE guideline: CE-EMC guideline (directive
Applied harmonized standards, in particular EN 55022 : 1998
Any modifications of the appliances described above that are carried out without prior
permission by KERN will render this declaration invalid.
Date: 19.12. 2006 Signature: Gottl. KERN & Sohn GmbH Management
Gottl. KERN & Sohn GmbH, Ziegelei 1, D-72322 Balingen-Frommern, Tel. +49-07433/9933-0, Fax +49-07433/9933-149
Type : KERN FKB 15K0.5A
KERN FKB 15K1A KERN FKB 30K1A KERN FKB 30K2A KERN FKB 60K2A KERN FKB 60K5A
about electromagnetic compatibility)
EN 61000-3-2: 1995/A1: 1998/A2 : 1998/A14 :2000
EN 61000-3-3 : 1995
EN 55024 :1998
in the version 89/336/EWG
6
FKB_A-BA-e-0711

3 Basic Information (General)

3.1 Proper use

The balance you purchased is intended to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic“ balance, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read.

3.2 Improper Use

Do not use balance for dynamic weighings. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the balance. (Example: Slowly draining fluids from a container on the balance). Do not leave permanent load on the weighing plate. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the balance, minus a possibly existing tare load, must be strictly avoided. Balance may be damage by this. Never operate balance in explosive environment. The serial version is not explosion protected. The structure of the balance may not be modified. This may lead to incorrect weighing results, safety-related faults and destruction of the balance. The balance may only be used according to the described conditions. Other areas of use must be released by KERN in writing.

3.3 Warranty

Warranty claims shall be voided in case
Our conditions in the operation manual are ignored
The appliance is used outside the described uses
The appliance is modified or opened
mechanical damage and damage caused by media, liquids,
natural wear and tear
The appliance is improperly set up or incorrectly electrically connected
The measuring system is overloaded
FKB_A-BA-e-0711
7

3.4 Monitoring of Test Resources

In the framework of quality assurance the measuring-related properties of the balance and, if applicable, the testing weight, must be checked regularly. The responsible user must define a suitable interval as well as type and scope of this test. Information is available on KERN’s home page (www.kern-sohn.com with regard to the monitoring of balance test substances and the test weights required for this. In KERN’s accredited DKD calibration laboratory test weights and balances may be calibrated (return to the national standard) fast and at moderate cost.

4 Basic Safety Precautions

4.1 Pay attention to the instructions in the Operation Manual

Carefully read this operation manual before setup and commissioning, even if you are already familiar with KERN balances.

4.2 Personnel training

The appliance may only be operated and maintained by trained personnel.

5 Transport and storage

5.1 Testing upon acceptance

When receiving the appliance, please check packaging immediately, and the appliance itself when unpacking for possible visible damage.

5.2 Packaging

Keep all parts of the original packaging in case you need to return the appliance. Only use original packaging for returning. Before sending, disconnect all connected cables and loose/movable parts. Attach possibly existing transport safeguards. Secure all parts, e.g. weighing plate, power unit etc., to prevent slipping and damage.
8
FKB_A-BA-e-0711

6 Unpacking, Setup and Commissioning

6.1 Installation Site, Location of Use

The balances are designed in a way that reliable weighing results are achieved in common conditions of use. You will work accurately and fast, if you select the right location for your balance.
Therefore, observe the following for the installation site:
Place the balance on a firm, level surface;
Avoid extreme heat as well as temperature fluctuation caused by installing next to
a radiator or in the direct sunlight;
Protect the balance against direct draughts due to open windows and doors;
Avoid jarring during weighing;
Protect the balance against high humidity, vapours and dust;
Do not expose the device to extreme dampness for longer periods of time. Non-
permitted condensation (condensation of air humidity on the appliance) may occur if a cold appliance is taken to a considerably warmer environment. In this case, acclimatize the disconnected appliance for ca. 2 hours at room temperature.
Avoid static charging of the material to be weighed, weighing container and windshield.
Major display deviations (incorrect weighing results) may be experienced should electromagnetic fields (e.g. due to mobile phones or radio equipment), static electricity accumulations or instable power supply occur. Change location or remove source of interference.

6.2 Unpacking

Carefully remove the balance from the packaging, remove plastic cover and setup balance at the intended workstation.

6.2.1 Setup

The balance must be installed in a way that the weighing plate is exactly in horizontal
position.
FKB_A-BA-e-0711
9

6.2.2 Scope of delivery

Serial accessories:
Balance
Weighing plate
2 x transport security
Mains power supply
Protective cover
Operating Manual

6.2.3 Basic structure

Place the balance on a horizontal and solid base.
Remove the transport security on the 4-point support.
Pull off the protection foil from the weighing plate if existing.
Attach the weighing plate.

6.3 Mains connection

Power is supplied via the external mains adapter. The stated voltage value must be the same as the local voltage. Only use original KERN mains adapters. Using other makes requires consent by KERN.

6.4 Operation using a (rechargeable) battery (optional)

Lift-off the battery cover on the lower side of the balance. Connect 9 V compound battery. Reinsert the battery cover.
For battery operation the balance has an automatic switch-off function which can be activated or deactivated in the menu (chapter 8.1). Proceed as follows:
Switch-on the balance using the
key and wait for the „0“ display. Press the key and keep it pressed until „UNIT“ appears on the display. Press the
key four times, in the display appears „AF“. Confirm by pressing the key. Use the key to choose between the two following settings:
1) „AF on“: To save the battery, the balance switches off automatically 3 minutes after having finished the weighing procedure.
2) „AF off“: Switch-off function deactivated.
Use the key to confirm your selected setting.
10
FKB_A-BA-e-0711