Contents
1 Technical data ................................................................................................... 4
2 Appliance overview display unit ...................................................................... 6
2.1 Keyboard overview .................................................................................................... 7
3 Basic Information (General ) ............................................................................. 7
3.1 Proper use ................................................................................................................. 7
3.2 Improper Use ............................................................................................................. 7
3.3 Warranty .................................................................................................................... 8
3.4 Monitoring of Test Resources .................................................................................... 8
4 Basic Safety Precauti on s .................................................................................. 9
4.1 Pay attention to the instructions in the Operation Manual .......................................... 9
4.2 Personnel training ...................................................................................................... 9
5 Transport and storage ...................................................................................... 9
5.1 Testing upon acceptance ........................................................................................... 9
5.2 Packaging / return transport ....................................................................................... 9
6 Unpacking and placing ................................................................................... 10
6.1 Installation Site, Location of Use ...............................................................................10
6.2 Unpacking/installation ...............................................................................................10
6.3 Scope of delivery / serial accessories: ......................................................................10
6.4 Mains connection ......................................................................................................10
6.5 Adjustment ................................................................................................................11
7 Operation ......................................................................................................... 13
7.1 Start-up .....................................................................................................................13
7.2 Switching Off ............................................................................................................
13
7.3 Zeroing .....................................................................................................................13
7.4 Simple weighing ........................................................................................................13
7.5 Weigh ing with tare ....................................................................................................14
7.6 Hold function (animal weighing function) ...................................................................15
8 Menu ................................................................................................................. 16
8.1 Navigation in the menu .............................................................................................16
8.2 Menu overview..........................................................................................................17
9 Servicing, maintenance, disposal .................................................................. 18
9.1 Cleaning ...................................................................................................................18
BIC-BA-e-1610 3
9.2 Servicing, maintenance .............................................................................................18
9.3 Disposal ....................................................................................................................18
10 Error messages, troubleshooting guide .................................................... 19
11 Declaration of conformity ........................................................................... 20
1 Technical data
KERN BIC 600K-1S BIC 600K-1 BIC 1T-4S
Readability (d) 100 g; 200 g 100 g; 200 g 200 g; 500 g Weighing range (max) 300 kg; 600 kg 300 kg; 600 kg 600 kg; 1,500 kg Reproducibility 100 g; 200 g 100 g; 200 g 500 g Linearity ± 300g; 600 g ± 300g; 600 g ± 1 kg Recommended
adjustment weight, not added (class)
600 kg
(M2)
600 kg
(M2)
1.5t
(M2)
Warm-up time 10 minutes Stabilization time (typical) 2 s Weighing unit kg, lb Auto Off 3 min. Ambient temperature -10°C – 40°C Humid environment 0 % - 80 % (non-condensing)
Electric Supply
Input voltage 100 V - 240 V, 50 / 60 Hz
Power pack secondary voltage 9V, 100mA
Dimensions display unit (B x D x H) mm
235 x 114 x 51 235 x 114 x 51 235 x 114 x 51
Weighing surface mm 1000 x 1000 1200×1500 1000 x 1000 Net weight kg 130 150 130
BIC-BA-e-1610 5
KERN BIC 1T-4 BIC 3T-3 BIC 3T-3L
Readability (d) 200 g; 500 g 500 g; 1,000 g 500 g; 1,000 g Weighing range (max) 600 kg; 1,500 kg 1,500 kg; 3,000
kg
1,500 kg; 3,000
kg
Reproducibility 500 g 500 g; 1,000 g 500 g; 1,000 g Linearity ± 1 kg ± 1.5 kg; 3 kg ± 1.5 kg; 3 kg Recommended
adjustment weight, not added (class)
1.5t
(M2)
3000 kg
(M2)
3000 kg
(M2)
Warm-up time 10 minutes Stabilization time (typical) 2 s Weighing unit kg, lb Auto Off 3 min. Ambient temperature
-10℃ – 40℃
Humid environment 0 % - 80 % (non-condensing)
Electric Supply
Input voltage 100 V - 240 V, 50 / 60 Hz
Power pack secondary voltage 9V, 100mA
Dimensions display unit (B x D x H) mm
235 x 114 x 51 235 x 114 x 51 235 x 114 x 51
Weighing surface mm 1200×1500 1200×1500 1500 x 1500 Net weight kg 150 150 150
2 Appliance overview display unit
1. Weight display
2. Buttons
3. Battery compartment
4. Guide rail support base / stand
5. End stop support base / stand
6. Mains adapter connection
7. Connection load cell cable
BIC-BA-e-1610 7
2.1 Keyboard overview
Button Function
Turn on/off balance
Hold/ animal weighing function
Tare balance
Switch-over weighing unit Back to weighing mode, or menu
3 Basic Information (General)
3.1 Proper use
The display unit acquired by you is used in combination with a weighing plate and serves to determine the weighing value of material to be weighed. It is intended to be used as a “non-automatic weighing system”, i.e. the material to be weighed is manually and carefully placed in the centre of the weighing plate. As soon as a stable weighing value is reached the weighing value can be read.
3.2 Improper Use
Do not use display unit for dynamic weighing. In the event that small quantities are removed or added to the material to be weighed, incorrect weighing results can be displayed due to the “stability compensation“ in the display unit. (Example: Slowly draining fluids from a container on the balance.) Do not leave permanent load on the weighing pan. This may damage the measuring system. Impacts and overloading exceeding the stated maximum load (max) of the weighing plate, minus a possibly existing tare load, must be strictly avoided. Both, the weighing plate and the display unit may be damaged during this process. Never operate display unit in explosive environment. The serial version is not explosion protected. Changes to the display unit's design are not permitted. This may lead to incorrect weighing results, safety-related faults and destructi on o f the dis pl ay unit. The display unit may only be operated in accordance with the described default settings. Other areas of use must be released by KERN in writing.