I. DESCRIPTION
This kit contains the cables and terminations required to operate two identical 750 Watt Model 26600
BOP power supplies in parallel, effectively multiplying the output current capacity by two.
Refer to the associated technical manual supplied with the 750 Watt Model 26600 BOP power supply
for all instructions regarding installation and operation of multiple units in parallel.
!
CAUTION: Failure to install the ground cable supplied can result in damage to the power supply.
II. SPECIFICATIONS
Table 2 lists the general specifications for the parallel combination of two identical 750 Watt Model
26600 BOP Power Supplies. For specifications not listed in Table 2, refer to the General Specifications
provided in the associated technical manual supplied with the Model 26600 BOP power supply
TABLE 1. EQUIPMENT SUPPLIED
Item Quantity Purpose
Output and Common
Power cable
(1.5 ft.)
Parallel Control Cable
(1.5 ft.)
Protection Cable
(1 ft.)
Master - IN Parallel
Control Termination
Protection - OUT
Termination (Slave)
Protection - IN
Termination (Master)
Instruction
Manual
Nut 2
Output Sense Cable 1 Connects Output sense terminal to Common sense terminal of next unit. 118-1271
Chassis Ground Cable 1 Connects chassis ground terminals of all units. 118-1272
Ground Cable mounting
hardware
2
1
1
1
1
1
1
2 sets Each set consists of eight parts, mounted in the following order: No. 10 star lock-
Connects the OUTPUT and COMMON terminal of the Master to the OUTPUT
and COMMON terminals of the Slave. 118-1112
Provides control signals required for parallel operation.
Provides interlock protection signals required for multiple unit operation.
Provides proper termination for Parallel Control Cable.
Provides proper termination for the slave connection to the Protection Cable.
Provides proper termination for the master connection to the Protection Cable.
Lists material supplied.
Overcomes tight space for output cable connections. After securing bottom cable
to output terminal stud using one nut, additional cables can be oriented for best
layout and secured with separate nut.
washer P/N 103-0106 (at chassis), No. 10 flat washer P/N 103-0031, No. 10 split
lockwasher P/N 103-0033, 10-32X3/8 nut P/N 102-0008, No. 10 flat washer P/N
103-0031, [lug(s) from ground cable], No. 10 flat washer P/N 103-0031, No. 10
split lockwasher P/N 103-0033, and 10-32X3/8 nut P/N 102-0008.
Kepco Part
Number
118-1202
118-1126
195-0109
195-0108
195-0107
228-1634
102-0046
(See
Purpose
at left for part
numbers)
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
©2012, KEPCO, INC
Data subject to change without notice
http://www.kepcopower.com email: hq@kepcopower.com
228-1634 REV 2 051412

TABLE 2. GENERAL SPECIFICATIONS FOR TWO (2) IDENTICAL BOP 1000 WATT UNITS (PARALLEL)
SPECIFICATION RATING/DESCRIPTION CONDITION
INPUT CHARACTERISTICS
Current 176 Va-c 15.0A a-c maximum
264 Va-c 10A a-c maximum
Leakage current 7mA a-c 230V a-c, 47-63 Hz
OUTPUT CHARACTERISTICS
d-c Output Range E
O Max
I
O Max
Closed Loop Gain Voltage Channel 0.6
Current Channel 25.0
Source/sink
adjustment range
Programming
resolution / accuracy
Voltage –6V to +6V
Current –250A to +250A
Voltage ±6mV
Current ±375mA
Voltage Limit ±6mV linearity ±120mV Full Scale tolerance
Current Limit ±375mA linearity ±2.75A Full Scale tolerance
Readback
resolution / accuracy
Voltage Same as individual unit Independent readings for each unit
Current Same as individual unit Independent readings for each unit
Current stabilization in current mode
Source effect ±125mA Min - max input voltage
Load effect ±500mA 0 to 100% load current
Time effect (drift) ±125mA 0.5 through 24 hours
Temperature effect ±125mA / °C 0° to 50°C
Ripple and noise ±5Ap-p Includes switching noise.
Voltage stabilization in voltage mode Same as individual unit
Rise/Fall Time
Voltage 250
Current 1.5mS/1.5mS
Frequency bandwidth
Voltage 2KHz
Current 400Hz Short circuit, I
±6V d-c
±250A d-c
µS/250µS
Nominal resistive load, measured from
10 to 90%, 0 to ±100% of rating
Short circuit, measured from 10% to
90%, 0 to ±100% of rating
Nominal resistive load, E
I
OPK
= I
ONOM
@ 60Hz
= I
OPK
ONOM
OPK
@ 60Hz
= E
ONOM
,
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000
FAX (718) 767-1102 email: kepcopower@aol.com
2 228-1634 REV 2 051412