kenwood KDC-V6090R, KDC-V6090RY, KDC-V7018R Service Manual

©
2001-3 PRINTED IN JAPAN
B51-7754-00 (N) 3394
CD RECEIVER
KDC-V6017
,
V6090R/RY
KDC-V7018R
47W 4
X
KDC-V6017
DAB
47W 4
X
KDC-V7018R
DAB
PTY
K
3i
TI VOL ADJ
47W 4
X
KDC-V6090R
DAB
PTY
K
3i
TI VOL ADJ
KDC-V7018R
KDC-V6090R/RY
ESCUTCHEON ASSY (B07-3007-03)
PANEL ASSY (A64-2168-02)
ESCUTCHEON ASSY (B07-3007-03)
FRONT GLASS (B10-3274-01)
PANEL ASSY (A64-2172-02)
DC CORD (E30-4940-05) : KDC-V6017
DC CORD (E30-4941-05) : KDC-V7018R
ANTENNA ADAPTOR (T90-0523/0534-05) : KDC-V6090R/RY
BATTERY (SIZE: AAA) Not supplied as service parts
SCREW SET (N99-1704-05)
SCREW SET (N99-1700-05) : KDC-V6017 KDC-V7018
LEVERx2 (D10-4562-04)
ESCUTCHEON (B07-3010-02) : KDC-V6017 KDC-V7018R
REMOTE CONTROLLER ASSY (A70-0883-05) : KDC-V6017 KDC-V7018R
MOUNTING HARDWARE ASSY (J21-9641-13)
PLASTIC CABINET ASSY (A02-1497-03)
STAY (J54-0606-04) : KDC-V6017 KDC-V7018R
DC CORD (E30-4943-05) : KDC-V6090RY (E30-4957-05) : KDC-V6090R
KDC-V6017
ESCUTCHEON ASSY (B07-3007-03)
FRONT GLASS (B10-3266-01)
PANEL ASSY (A64-2164-02)
FRONT GLASS (B10-3270-01)
The MECHANISM OPERATION DESCRIPTION is the same as model KDC-S3007 and KDC-5050RG. Please refer to the service manual for model KDC-S3007(B51-7029-00) or KDC-5050RG(B51-7099-00).
KDC-V6017,V6090R/RY,V7018R
2

BLOCK DIAGRAM

PLL+B
FM+B
Q45,47
Q46,48
AM+B
DIMMER
MUTE
2WAY
DET.
ACC
BU DET.
A8V
A8V
Q14,15
Q18
Q16,17
Q19-22
SERVO AVRSERVO+B
SW5V
Q13
Q55,56
Q33
Q11,12
SW5V
BU5V
BU5V
P CON
ANT-CON
Q27,29,30
Q32
MUTE
IC3
Q7
DRIVER
MUTE
Q1,2,5,6
POWER IC
IC4
u-COM
CD
CH
F/E
A1
E-VOL
IC2
PRE OUT
SP-OUT
DIMMER
TEL-MUTE
ACC
ANT-CONT
Q28,31
P-CONT
BACK UP
A-CONT
P-CONT
DECODER
RDS
(M,E)TYPE
IC1
IC7
Q51
EX.AMP CONTROL
ILLUM
+B
PANEL u-COM
RESET
SW
RESET IC
IC8
IC3
IC1
IC2
Q2,3
Q1
LCD
DRIVER
REMO
G/R SW
BUFFER
NOISE
Q43
PRE OUT OUTPUT VOLTAGE
CONTROL
EX.AMP
Q25
Q26
Q34
(M,E) TYPE
(M,E) TYPE
(M,E) TYPE
(K) TYPE
NAVI-MUTE
PANEL 5V
PANEL 5V
KEY MATRIX
SW14V
PANEL POSITION DET.
(BACK LIGHT V-ILL)
LCD
ED1
CH
QUAL
SERVO+B
MUTE R
STOP
SW2
LO/EJ
MUTE L
RST
SW3
SW1
SDA
SCL
A8V BU5V
SW5V
RST
REQ C
CLK
CH-CON
DATA H
REQ H
CD
AM
FM
P MUTE
MUTE
SW5V
PANEL5V
MC REQ/PANEL
PANEL RST
SC REQ
MC CLK
SC DATA
REMO
RESET
ILL+B
SRT-SW1
SRT-SW2
RDCK
RDDA
QUAL
SDA
SCL
AFS
AFS
A8V
PLL DATA
PLL CLK
IFC OUT
S-METER
SW5V
DATA C
BACK UP
BU5V
PANEL 5V
600mV
3600mV
CHANGER
AM
1800mVFM
230mV
1200mV
1200mV
251mV (E TYPE)
470mV (K,M TYPE)
AUDIO OUT
FM+B
NOISE
3600mVCD
K,M TYPEMODEL
3600mV
3600mV
855mV
1372mV
E TYPE
DRIVER
MUTE
MO SW
LCD AVR
(X13- )
KDC-V6017,V6090R/RY,V7018R
3

COMPONENTS DESCRIPTION

Ref.No. Component Name Application/Function Operation/Condition/Compatibility
IC1 UPD780076GK501 Panel MI-COM. IC2 LC75878W LCD driver IC3 RS-171 Remote sensor IC
Q1 2SC2412K or 2SD601A VLCD AVR Q2 2SD2114K Green LED SW When a base goes "Hi", GREEN LEDs are turned on. Q3 2SD2114K Red LED SW When a base goes "Hi", RED LEDs are turned on.
Q4 DTA144EUA or KRA304 REMO SW
While
a
base goes "Lo", PAN 5V is supplied to the Remote
sensor IC. Q5 2SC2412K or 2SD601A CONT R SW When a base goes "Hi", RED LEDs are turned on. Q6 2SC2412K or 2SD601A CONT G SW When a base goes "Hi", GREEN LEDs are turned on. Q7 2SC2412K or 2SD601A CONT B SW When a base goes "Hi", BLUE LEDs are turned on.
Ref.No. Component Name Application/Function Operation/Condition/Compatibility
IC1 UPD703033GC076 System MI-COM. IC2 TDA7407D E.VOL & N.C.MPX IC IC3 HD74HC02FP
or TC74HC02AF
Mute logic 2-input NOR x 4
IC4 TA8263BH Power AMP. IC IC7 TDA7479D RDS decoder IC8 S-80837ANNP Reset IC When BU 5V voltage is less than 3.7V, IC outputs "Lo".
Q1 DTC143TUA or KRC410 Pre mute (Front L) When Q1's base goes "Hi", Pre-output is muted. Q2 DTC143TUA or KRC410 Pre mute (Front R) When Q2's base goes "Hi", Pre-output is muted. Q5 DTC143TUA or KRC410 Pre mute (Rear L) When Q5's base goes "Hi", Pre-output is muted. Q6 DTC143TUA or KRC410 Pre mute (Rear R) When Q6's base goes "Hi", Pre-output is muted.
Q7 DTA124EUA or KRA303 Mute driver
When BU detection SW or System RESET or MI-COM.'s
Pre-mute is working, a base goes "Lo", and Q7 is turned on.
Q11 2SC4081 or 2SD1819A
BU 5V AVR
While BACKUP is applied, AVR outputs +5V.
Q12 2SB1548(P) Q11 and Q12 are inverted Darlington connection.
Q13 2SA1576A or 2SB1218A SW 5V
While a base goes "Lo", SW 5V is supplied to the
microprocessor peripheral circuits.
Q14 2SC4081 or 2SD1819A
A8V AVR When Q14's base goes "Hi", A8V AVR outputs 8V.
Q15 2SB1548(P) Q16 DTC124EUA or UN5212 A8V AVR and SERVO +B AVR ON/OFF control
Q17 DTA124EUA or KRA303
SW14V SW While Q16's base goes "Hi", Q17 is turned on,
A8V AVR and SERVO +B AVR are working.
Q18 2SD2375 SERVO +B AVR
When Q18's base goes "Hi", SERVO +B AVR outputs 8V.
Q19 DTC124EUA or UN5212 ILL +B AVR ON/OFF control
Q20 DTA124EUA or KRA303
ILL +B SW While Q19's base goes "Hi", Q20 is turned on,
and ILL +B AVR is working.
Q21 2SB1184
ILL +B AVR
While Q22's base goes "Hi", AVR outputs +10.5V.
Q22 2SC4081 or 2SD1819A
Works during POWER ON mode with a panel attached to the set.
SWITCH UNIT (X13-99XX-XX)
ELECTRIC UNIT (X25-87XX-XX)
KDC-V6017,V6090R/RY,V7018R
4
Ref.No. Component Name Application/Function Operation/Condition/Compatibility
Q25 DTA123JK or KRA105S EXT. AMP CON. SW When a base goes "Lo", Q25 is turned on. Q26 DTC144EUA or UN5213 Small lamp detection SW When vehicle small lamps turn on, Q26 is turned on . Q27 DTC114YUA or UN5214
P-CON SW
When Q27's base goes "Hi", Q32 is turned on . Q32 2SB1277(Q,R) Works during POWER ON mode. Q29 DTA124EUA or KRA303 P-CON. protection inhibit SW
Prevents Q30 tuning ON during start-up after power ON. Q30 2SA1576A or 2SB1218A P-CON. protection SW
Protect Q32 by turning ON when P-CON output is grounded. Q28 DTC114YUA or UN5214
ANT-CON. SW
When Q28's base goes "Hi", Q31 is turned on. Q31 2SB1277(Q,R) Works during TUNER mode.
While BACKUP is applied, a base goes "Hi", and Q33 is turned on. Q33 2SC4081 or 2SD1819A BU detection SW
When momentary power down has detected, a base goes "Lo",
and Q33 is turned off. Q34 2SC4081 or 2SD1819A ACC detection SW
While ACC is applied, a base goes "Hi", and Q34 is turned on.
Q42 DTC124EUA or UN5212 E. VOL mute SW
When BU detection SW or MI-COM.'s mute is working,
a base goes "Hi", and Q42 is turned on. Q43 2SC4081 or 2SD1819A Noise buffer Q45 DTC124EUA or UN5212
FM +B SW
When Q45's base goes "Hi", Q47 is turned on . Q47 2SB1277(Q,R) Works during FM reception mode. Q46 DTC124EUA or UN5212
AM +B SW
When Q46's base goes "Hi", Q48 is turned on . Q48 2SB1277(Q,R) Works during AM reception mode. Q51 DTC144EUA or UN5213 IFC buffer Waveform shaping Q52 2SC4081 or 2SD1819A Composite signal output buffer Q55 2SA1576A or 2SB1218A
PAN 5V SW
While a panel is attached to the set, Q56's base goes "Hi", Q56 DTC124EUA or UN5212
and Q55 is turned on.
Ref.No. Component Name Application/Function Operation/Condition/Compatibility
Generation of RF signal based on the signals from the APC
circuit and pickup, and generation of servo error (focusing
IC1 AN22000AA RF amplifier
error and tracking error)signals.
Detection of dropout, anti-shock, track crossing and off-track
conditions, Gain control function building in.
IC2 MN662773KF1
CD signal processor bult-in MI-COM.
IC4 BA5917AFP 4CH BTL driver
Focusing coil, tracking coil, spindle motor and sled motor driver
IC5 TA78L05AFP 5V AVR AVR outputs +5V for D/A converter analogue part. IC6 NJM4565MD OP Amp. Low pass filter
Q1 MCH6101 APC LD power control
Q2 DTC124EUA P ON SW
When CD source is selected, Q2's base goes "Hi",
Q3 and Q4 are turned on.
Q3 2SA1362(Y) A.8V SW
A8V ON/OFF control. When a base goes "Lo", Q3 is turnde on.
Q4 2SA1362(Y) D.5V SW
D5V ON/OFF control. When a base goes "Lo", Q4 is turnde on.
Q5 DTC124EUA MOTOR SW
When CD loading or eject operation is activating,
Q5's base goes "Hi", Q4 is turned on.
CD PLAYER UNIT (X32-5030-00)
COMPONENTS DESCRIPTION
KDC-V6017,V6090R/RY,V7018R
5
IC1 (SWITCH UNIT : X13-99XX-XX)

MICROCOMPUTER'S TERMINAL DESCRIPTION

Pin No. Pin Name I/O Description Processing Operation
1 REMO ON O Remote sensor IC on/off control
"Lo": PAN 5V is supplied to the Remote sensor IC. 2 RED O Red LED on/off control "Hi": Red LEDs are turned on. 3 GREEN O Green LED on/off control "Hi": Green LEDs are turned on. 4 KR5 I Key return 5 5 KR4 I Key return 4 6 KR3 I Key return 3 7 KR2 I Key return 2 8 KR1 I Key return 1 9 AVSS - Ground connection terminal Connected to GND lines.
10 VDD - Positive power supply connection terminal Connected to PAN 5V lines. 11 KS4 O Key scan 4 12 KS3 O Key scan 3 13 KS2 O Key scan 2 14 KS1 O Key scan 1 15 MC DATA I Data input from system MI-COM. 16 SC DATA I/O Data output to system MI-COM. 17 MC CLK I Clock input from system MI-COM. 18 L CE O CE output to LCD driver IC 19 L DATA O Data output to LCD driver IC 20 L CLK O Clock output to LCD driver IC 21 NC O Not used(N.C.) 22 TYPE I Destination type input terminal Not used(pull down to GND lines) 23 L INH O Inhibit output to LCD driver IC "Lo": LCD indication off 24 VDD - Positive power supply connection terminal Connected to PAN 5V lines. 25 AVSS - Ground connection terminal Connected to GND lines. 26 NC I Not used (connected to GND lines) 27 NC I Not used (connected to GND lines) 28 NC I Not used (connected to GND lines) 29 NC I Not used (connected to GND lines) 30 NC I Not used (connected to GND lines) 31 NC I Not used (connected to GND lines) 32 NC I Not used (connected to GND lines) 33 NC I Not used (connected to GND lines) 34 AVREF I
A/D converter reference voltage input terminal
Connected to GND lines.
35 NC O Not used (N.C.) 36 RESET I Reset input "Lo": Panel MI-COM. reset 37 XT2 - Sub clock resonator connection terminal Not used (N.C.) 38 XT1 I Sub clock resonator connection terminal Not used (connected to PAN 5V lines) 39 TEST I Test terminal Not used (connected to GND lines) 40 X2 - Main clock resonator connection terminal 41 X1 I Main clock resonator connection terminal 42 VSS - Ground connection terminal Connected to GND lines. 43 MC REQ I Request input from system MI-COM. 44 SC CON I Panel MI-COM. on/off control "Hi": Operation mode, "Lo": Standby mode 45 SRC I SRC key detection "Hi": SRC key pressed 46 OPEN-EJECT I OPEN-EJECT key input "Hi": EJECT key pressed 47 CONT G O
Green LED control output for variable illumination 48 SC REQ O Request output to system MI-COM. 49 NC O Not used(N.C.) 50 CONT B O
Blue LED control output for variable illumination 51 NC O Not used(N.C.) 52 CONT R O
Red LED control output for variable illumination 53 EJECT I EJECT key detection "Hi": EJECT key pressed 54 NC O Not used(N.C.) 55 NC O Not used(N.C.) 56 NC O Not used(N.C.) 57 NC O Not used(N.C.) 58 NC O Not used(N.C.)
KDC-V6017,V6090R/RY,V7018R
6
Pin No. Pin Name I/O Description Processing Operation
Pin No. Pin Name I/O Description Processing Operation
MICROCOMPUTER'S TERMINAL DESCRIPTION
IC1 (ELECTRIC UNIT : X25-87XX-XX)
59 NC O Not used(N.C.) 60 NC O Not used(N.C.) 61 NC O Not used(N.C.) 62 NC O Not used(N.C.) 63 NC O Not used(N.C.) 64 NC O Not used(N.C.)
1 AM+B O AM+B control "Hi": During AM reception. 2 FM+B O FM+B control
"Hi": During FM reception, "Hi": Last FM mode (only RDS model)
3 AFS O
Noise detection time constant switching terminal
"Hi": During FM reception, "Lo": During FM seek or AF search 4 PLL-DATA I/O Data input/output with F/E 5 PLL-CLK I/O Clock input/output with F/E 6 EVDD - Power supply connection terminal Connected to BU 5V lines. 7 EVSS - Ground connection terminal Connected to GND. 8 NC O Not used(N.C.) 9 BEEP O BEEP sound output
10 REMO I
Data input from the remote control light sensor 11 CH-REQH O Request output to changers "Lo": Request 12 CH-RST O Reset output to changers : Reset 13 IC2-SDA I/O
Data line with IC2, IC5 and CD MECHA. MI-COM. 14 IC2-CLK I/O
Clock line with IC2, IC5 and CD MECHA. MI-COM. 15 CH-MUTE I Mute request from changers "Hi": Mute request 16 CH-CON O Changer control "Hi": Operation mode, "Lo": Standby mode
17
DIMMER-CON/
O Panel MI-COM. ON/OFF control
"Hi": POWER ON mode
SC-CON
"Lo": POWER OFF mode or panel detached or panel mask position 18 TEST - Test terminal Not used(Connected to GND) 19 P-MUTE O Power IC mute control output "Lo": Mute (POWER OFF, TEL MUTE) 20 P-STBY O Power IC standby control output
"Hi": POWER ON mode except panel detached or panel mask position 21 MUTE O IC2 mute control output "Hi": Mute on 22 NC O Not used(N.C.) 23 PRE-MUTE O Pre-output Mute control output "Lo": Mute 24 ACC-DET I ACC detection input "Hi": ACC OFF, "Lo": ACC ON 25 DIMMER I Small lights detection input "Lo": During vehicle small lamps turn on. 26 SW5V O SW 5V control output
"Lo": POWER ON mode or during CD loading/eject action
Bass boost OFF__"Hi": 160msec, "Lo": 40msec 27 EXT-AMP-CON O External amp. control output Bass boost LOW__"Hi": 130msec, "Lo": 70msec
Bass boost HI__ "Hi": 100msec, "Lo": 100msec 28 P-CON O Power control output "Hi": POWER ON mode except ALL OFF mode 29 ANT-CON O Antenna control output "Hi": During FM/AM reception or TI reception 30 P-ON O SW 14V control output
"Hi": POWER ON mode or during CD loading/eject action 31 RESET I Reset input terminal "Lo": System reset 32 XT1 I Sub clock resonator connection terminal Clock count during POWER OFF mode 33 XT2 - Sub clock resonator connection terminal 34 REGC - C terminal
35 X2 - Main clock resonator connection terminal
Oscillation stop: POWER OFF mode or momentary
power down detected 36 X1 I Main clock resonator connection terminal 37 VSS - Ground connection terminal Connected to GND lines. 38 VDD - Power supply connection terminal Connected to BU 5V lines. 39 CLKOUT O Internal system clock output 40 NC O Not used(N.C.) 41 NC O Not used(N.C.) 42 TYPE0 I Destination type input terminal 0 43 TYPE1 I Destination type input terminal 1 44 TYPE2 I Destination type input terminal 2
KDC-V6017,V6090R/RY,V7018R
7
Pin No. Pin Name I/O Description Processing Operation
MICROCOMPUTER'S TERMINAL DESCRIPTION
45 TYPE3 I Destination type input terminal 3 46 IC2TYPE0 I IC2 setting terminal "Lo": Initial value 47 IC2TYPE1 I IC2 setting terminal "Lo": Initial value 48 NC O Not used(N.C.) 49 NC O Not used(N.C.) 50 NC O Not used(N.C.) 51 NC O Not used(N.C.)
52 ILL-ON O Illumination AVR ON/OFF control output
"Hi": POWER ON mode except panel detached or panel mask position
53 M-MUTE L I
Mute request (Lch) from CD MECHA. MI-COM.
"Lo": Mute request
54 M-MUTE R I
Mute request (Rch) from CD MECHA. MI-COM.
"Lo": Mute request 55 BVDD - Power supply connection terminal Connected to BU 5V lines. 56 BVSS - Ground connection terminal Connected to GND lines. 57 M-RST O Reset output to CD MECHA. MI-COM. "Lo": Reset 58 M-STOP O Stop request to CD MECHA. MI-COM. "Lo": Stop mode, "Hi": Operation mode 59 NC O Not used (N.C.) 60 LO/EJ I/O
CD MECHA. loading/Eject switching output
"Lo": Loading, "Hi": Eject, "Hi-Z": Stop or Break 61 MOSW O
CD mechanism loading motor control output
"Hi": CD loading/eject action or Break, "Lo": other 62 NC O Not used (N.C.) 63 CD-SW3 I Down & limit switch detection input "Hi": Chucking, "Lo": Pickup most inner position 64 P-RESET O Reset output to panel MI-COM. "Lo": Reset 65
L-CE/MC REQ/PANEL
I/O Request output to panel MI-COM. 66 NC O Not used (N.C.) 67 NC O Not used (N.C.) 68 NC O Not used (N.C.) 69 NC O Not used (N.C.) 70 AVCONT O
A/D converter reference voltage control output
"Hi": Active, Connected to AVREF terminal.
71 AVDD -
A/D converter power supply connection terminal
Connected to BU 5V lines.
72 AVSS -
A/D, D/A converter ground connection terminal
Connected to GND.
73 AVREF I
A/D converter reference voltage input terminal
74 PHONE I PHONE detection input
1V or less: TEL MUTE, 2.5V or greater: NAVI MUTE 75 NC(GND) I Not used (pull down to GND lines) 76 NC(GND) I Not used (pull down to GND lines) 77 SRT-SW2 I SRT position detection input
Panel: (SW1, SW2)=(Hi, Hi), Slide: (SW1, SW2)=(Hi, Lo) 78 SRT-SW1 I SRT position detection input Mask : (SW1, SW2)=(Lo, Lo) 79 NOISE I FM noise detection input 80 S-METER I S-meter input from F/E 81 R-DATA I Data input from the RDS decoder IC
Except RDS model: Not used(pull down to GND lines) 82 R-QUAL I Quality input from the RDS decoder IC
Except RDS model: Not used(pull down to GND lines) 83 IFC-OUT I IFC OUT of the F/E input terminal "Hi": Station detected, "Lo": Not detected 84 NC(GND) I Not used (pull down to GND lines) 85 NC(GND) I Not used (pull down to GND lines) 86 NC O Not used (N.C.) 87 R-CLK I Clock input from the RDS decoder IC
Except RDS model: Not used (pull down to GND lines) 88 CH-REQC I Request input from changers "Lo": Request 89
KEY-REQ/SC-REQICommunication request input form panel MI-COM. 90 CD-SW1 I Loading detection "Lo": CD chucking. 91 CD-SW2 I 12cm disc detection terminal
When 12cm disc was detected, the input becomes "Lo" temporarily.
92 NC O Not used (N.C.)
93 BU-DET I Momentary power down detection input
"Hi" : When momentary power down detected or BU OFF
"Lo" : BU ON 94 CH-DATAC I Data input from changers 95 CH-DATAH O Data output to changers 96 CH-CLK I/O Clock input/output with changers 97
L-DATAL/SC-DATA
I Data input from panel MI-COM.
98
L-DATAS/MC-DATA
I/O Data output to panel MI-COM.
99
L-CLK/PANEL/MC-CLK
I/O Clock output to panel MI-COM.
100 PAN5V O Panel 5V control "Hi": Panel attached, "Lo": Panel detached
KDC-V6017,V6090R/RY,V7018R
8

TEST MODE

TEST MODE
1. How to enter the test mode While holding the FM and Preset 6 keys, reset the unit.
2. How to exit from the test mode While holding the Preset 6 key, reset the unit. (Note) The test mode cannot be terminated by ACC OFF,
power OFF or momentary power down.
3. Initial status in the test mode
Sources : ALL OFF
Display : All segments are lit.
Volume : -10 dB (displayed as "30")
Loudness : OFF
CRSC : OFF regardless of the presence of
switching function.
SYSTEM Q : Flat
LED : White for no scanning. (VLCD model)
4. Special display in Tuner mode When any of the following messages is displayed in Tuner mode, the F/E may be abnormal.
"TNE2P NG" : The EEPROM is set to the default
(unstable values) because the F/E was shipped without passing through the adjustment process, etc.
"TNCON NG" : Communication with the F/E is not
possible.
5. Forced switching of K3I Each press of the Preset 6 key in Tuner mode should switch K3I from AUTO Forced Wide Forced Middle Forced Narrow AUTO. The initial status is AUTO and the display shows these modes as follows.
AUTO : FMA
Forced Wide : FMW
Forced Middle : FMM
Forced Narrow : FMN
6. Test mode specifications of the CD receiver
Forced ejection is inhibited in the reset start operation.
When the unit is reset while a CD is loaded in it, the CD is not recognized by resetting.
Each press of the Track Up key jumps to the following
track numbers: No. 9No. 15 No. 10 No. 11 No. 12 No. 13 No. 14 No. 9 (The cycle restarts from here.)
Each press of the Track Down key jumps to the previ-
ous track number to the track being played.
7. Audio-related specifications
A short press of the Q key initiates the audio adjustment
mode.
Pressing the ∗ key on the remote initiates the audio
adjustment mode.
Continuous holding of a remote control key is inhibited.
Bass, Middle and Treble are adjusted in 3 steps of
Min/Center/Max with the Track Up/Down keys.
Balance is adjusted in 3 steps of Left Max/Center/Right Max with the Track Up/Down keys.
Fader is adjusted in 3 steps of Rear Max/Center/Front Max with the Track Up/Down keys.
HPF is adjusted in 2 steps of Through/220 Hz with the Track Up/Down keys.
LPF is adjusted in 2 steps of Through/120 Hz with the Track Up/Down keys.
Bass f, Bass Q, Bass EXT, Middle f, Middle Q and Treble f are not dealt with by the audio adjustment.
8. Menu-related specifications
A short press of the CLK key initiates the Menu mode.
Pressing the DNPP/SBF key on the remote initiates the
Menu mode.
Continuous holding of a remote control key is inhibited.
Calendar adjustment, calendar display switching and
calendar memo are eliminated from the targets of con­tinuous key holding. (FL model)
In the color adjustment mode, pressing the Preset 1 key sets Red, 2 sets Blue, 3 sets Green and 4 sets Green. (VLCD model)
Contrast is adjusted in 3 steps of 0/5/10 and the default is 5. (VLCD/LCD model)
Brightness is adjusted in 3 steps of 0/5/10 and the default is 10. (Normal FL model)
9. Backup current measurement When the unit is reset while ACC is OFF (i.e. by turning Backup ON), the MUTE terminal goes OFF in 2 seconds in place of 15 second. (The panel, CD mechanism and TAPE mechanism are not activated at this time.)
10. Special display when the display is all on Pressing the Preset keys while the power is ALL OFF dis­plays the following information.
Version display (8 digits, Month/Day/Hour/Minute)
[PRESET 1] (Display) SYS xxxxxxxx System microcomputer
PAN xxxxxxxx Panel microcomputer
[PRESET 2]
Serial No. display (8 digits)
(Note) CD/RK type eXcelon model
(Display) S. No. xxxxxxxx Short press : View power ON time.
(The All OFF period is not counted.)
[PRESET 3] Long press/hold : Clear power ON time.
(Display) PonTim xxxxx Max. 65535 (hours) Short press
: Display TAPE/CD/MD operation time.
[PRESET 4] Long press/hold
: Clear TAPE/CD/MD operation time
(Display) CDTime xxxxx (CD/R)
TapTim xxxxx (C/R) Max. 65535 (hours)
Short press
: Display TAPE/CD/MD ejection count.
[PRESET 5] Long press/hold
: Clear TAPE/CD/MD ejection count.
(Display) EjeTim xxxxx Max. 65535 (times) Short press : Display Panel open/close count.
[PRESET 6] Long press/hold : Clear Panel open/close count.
(Display) PnCnt xxxxx Max. 655350 (times)
KDC-V6017,V6090R/RY,V7018R
9
TEST MODE
11. Other specifications
Automatic panel closing when a tape/CD is inserted is inhibited. (M&T model)
Panel operation by turning power OFF/ON is inhibited. (M&T model)
Messages such as "CODE OFF" are not displayed when power is turned ON.
Pressing the ATT key opens or closes the panel. (M&T model)
Pressing the TI (AUTO) key during changer operation turns 2zone ON. 2zone can be turned OFF by pressing the TI (AUTO) key again. The P/S dot lights while 2zone is ON.
Pressing and holding the CLK key for a second in the ALL OFF status the Mask Key (security) write mode.
• Security-related information
1. Forced Power ON mode (All models) Even when the security (Mask key) is approved, resetting the unit while holding the ATT and Preset 4 keys makes it possible to turn the power ON for 30 minutes. After 30 minutes have elapsed, it is not possible to return to the previous condition unless the unit is reset again.
2. Method of registration of the security code after EEPROM
(Tuner Unit Ass'y) replacement (Code security model)
(1) Enter the test mode. (See " 1. How to enter the test
mode")
(2) Press the CLK key to enter the security registration
mode.
(3) Enter the code using the Preset 1/2/3/4 keys.
Example: To enter "3510"
Press the Preset 1 key 4 times.
Press the Preset 2 key 6 times.
Press the Preset 3 key twice.
Press the Preset 4 key once.
(4) Press and hold the DISP key for 3 seconds until
"APPROVED" is displayed.
(5) Exit from the test mode. (See " 2. How to exit from the
test mode")
(Note) All Clear is not applicable to the security code of
this model.
3. Simplified method of clearing the security code (K Type
only)
(1) While the code entry is requested, press and hold the
VOL UP key for 3 seconds while holding the DISP key pressed. (This should turn "----" off.)
(2) Enter "KCAR" from the remote. (Same way as the 00
model) Press the 5 key on the remote twice, then press the Track Up key. (This enters "K".) Press the 2 key on the remote 3 times, then press the Track Up key. (This enters "C".) Press the 2 key on the remote once, then press the Track Up key. (This enters "A".) Press the 7 key on the remote twice, then press the Track Up key. (This enters "R".)
(3) The security code is cleared and the unit enters the
ALL OFF mode.
(4) If you commit a mistake in the code entry, the unit
enters the code request mode again.
4. Method of writing the Mask key while the EEPROM is in the initial status
(1) Enter the test mode. (See " 1. How to enter the test
mode")
(2) Press the CLK key to enter the Mask key registration
mode. "TRANSMIT1" should be displayed now. The display at this time should show " < > " in place of " [ ] ".
(3) Point the Mask key remote toward the light sensor,
and press and hold its key for more than 0.5 second.
(4) When "TRANSMIT2" is displayed, press and hold the
key on the Mask key remote for more than 0.5 second again. The first and second counter codes are not compared at this time.
(5) When "APPROVED" is displayed, the write operation
is complete. Now the demonstration mode is initiated and the test mode is terminated.
(Note) In the same way as previous models, if 30 minutes
have elapsed with no code written, an error occurs and the power is turned OFF.
5. Method of initializing the Mask key
(How to reset the unit from the Mask key approved condi­tion to the factory condition)
(1) Enter the test mode. (See " 1. How to enter the test
mode")
(2) "TRANSMIT1" is displayed and the Mask key entry
request mode is initiated. The display at this time should show " ∗ ∗ " in place of " [ ] ".
(3) Press and hold the key on the Master key remote for
more than 3 seconds.
(4) When "TRANSMIT2" is displayed, press and hold the
key on the Master key remote for more than 3 sec­onds again.
(5) When "APPROVED" is displayed, the Mask key is
cleared, the demonstration mode is initiated, the test mode is terminated and the unit returns to the factory condition.
6. Method of clearing all Mask key-related data
(1) Enter the test mode. (See " 1. How to enter the test
mode")
(2) Press the CLK key to enter the Mask key registration
mode. "TRANSMIT1" should be displayed now.
(3) Point the Master key remote toward the light sensor,
and press and hold its key for more than 3 seconds (until the level display shows the full condition).
(4) When "TRANSMIT2" is displayed, hold the key on the
Mask key remote for more than 3 seconds again. If "TRANSMIT1" is displayed in place of "TRANS­MIT2", restart the procedure from step (3).
(5) When "APPROVED" is displayed, all security data is
cleared and the unit returns to the condition before Mask key writing with the EEPROM in the initial sta­tus.
Loading...