Kenwood KD-CU-546-BT, KD-CBT-645-U, KD-CBT-40-U Service Manual

CD RECEIVER
KDC-BT40U/BT645U KDC-U546BT
© 2010-1 PRINTED IN JA PAN B53-0781-00 (N) 341
Panel assy KDC-BT40U (A64-5015-02)
Bluetooth
Panel assy KDC-U546BT (A64-5017-02)
Bluetooth
Mounting hardware assy (J22-0789-03)
KDC-BT40U
KDC-U546BT
Escutcheon (B07-3271-01)
TDF SPARE-PANEL
MAIN UNIT NAME TDF PARTS No. TDF NAME KDC-BT40U Y33-3272-72 TDF-BT40U KDC-BT645U Y33-3270-10 TDF-BT06D KDC-U546BT Y33-3270-21 TDF-U546BT
* Carrying case (W01-1710-05)
Panel assy KDC-BT645U (A64-5013-02)
KDC-BT645U
Bluetooth
* Remote controller assy (RC-405) (A70-2104-05)
* Screw (4x16) (N84-4016-48)
* Depends on the model. Refer to the parts list.
* Screw set (N99-1757-15)
* DC cord (E30-6934-05)
Lever (D10-7106-04) x2
* DC cord (E30-6933-05)
This product complies with the
* Plastic cabinet assy (A02-2755-23)
This product uses Lead Free solder.
RoHS directive for the European market.
KDC-BT40U/BT645U KDC-U546BT

BLOCK DIAGRAM

ELECTRIC UNIT (X34- )
ANT.
IC501
TUNER
(ATOMIC)
2
SW5
1
IC7
RDS DECODER
2
IC1
3
IC8
RESET IC
BU5
OEM REMOTE
S3
RESET
J3
J4
J2
FRONT AUX
REMOTE
to GND
S1
ROTARY ENCODER
PAN SW5
PAN SW5
PANEL DET
IC2
SWITCH UNIT (X16- )
A8V
A8V
8
12
J4
LX-BUS
IC2
E-VOL
2
SYSTEM u-COM
111
Q301
PANEL5V
USB5V
SW5
2
USB CN
ED1
J3
BU
MUTE
1
5
BU5
CONNECTOR
PANEL5V
5
9
ILLUMI+B
FL
R15
FL+B
1
1
1/2W Rx1
1/2W Rx2
1
FL+B
R31,32
KEY MATRIX
BU5
13
BU5
KEY ILLUMI
9
DME1
CD MECHA
SERVO+B
2
CN1
BT MIC CN
1
1
Q104,105
2
IC6
POWER IC
Q707
PRE MUTE
MUTE
1
IC900
LPF
Q902
LEVEL SHIFT
BU5
BU
Q701-706
PRE-OUT
FRONT REAR REAR/SW
BU DET
RESET
DC-CN etc
PHONE ACC-DET / BU-DET PS1-1 / PS1-2 PS1-3 / PS2-1
A8V
A900
BLUETOOTH MODULE
BT3.3V
USB5V
FL+B
ACC DET
PS1-1 / PS1-2 PS1-3 / PS2-1
SW5
A8V
SW5
BU5V
ILLUMI+B
SERVO+B
IC901
BT3.3V
IC52
HI-SIDE SW
PHONE
BU DET
P-STBY
2
R118
Q101
ACC DET
Q103
Q102
IC4
POWER SUPPLY IC
Q2,3
Q11,12
DC/DC5V
PHONE
BU DET
SURGE DET
CD SERVO
SW14V
IC51
SW5
BU5
SW5V
J1
DC-CN
PHONE
SP-OUT FRONT L/R REAR L/R
ACC
BU
P-ANT P-CON
DPU1
ACB
EF
FO COIL
TR COIL
DM1
SPINDLE MOTOR
DM2
LOADING & SLED MOTOR
CD PLAYER UNIT (X32-6260-01)
IC2
SIGNAL A/B/C/E/F
Q7
APC
IC3
FOO
TRO
MOTOR DRIVER
DMO
FMO
PD
LD
VREF
FOO
TRO
DMO
FMO
X3
CLOCK
16.934MHz
Q3
SW
RF AMP
+ SERVO PROCESSOR
+ MP3 DECODER
+ WMA DECODER
+ AAC DECODER
+ 1Mbit SRAM
DVSS
BU1.5V
SW1.5V
D3.3V
AVSS
S
D
G
CD REQ
SRAMSTB
BSIF ST REQ
BSIF GATE BSIF DATA
BSIF BCK
BSIF LRCK
A3.3VLORO
SW3.3V
SO
SI
BUCK
CCE
RST
Z DET
IC4
iPod AUTHENTICATION
IC1
CD SO CD CLK DSP REQ CE CD SRAMSTB CD RST ZDET IN
BSIF ST REQ BSIF GATE BSIF DATA BSIF BCK BSIF LRCK
CD DRIVE MUTE IPOD SDA IPOD SCL
IC9
MECHANISM u-COM
DVCC3A
PWE
RVIN1/RVIN2
PON
DVSS
Q5
SW
SW3.3V REG
X2
CLOCK
9.000MHzX132.768kHz
CLOCK
USB VBUS SW
CD LOE LIM SW
DVCC3B
BU3.3V
BU1.5V
DATA SCD SI
REQ A
MSTOP
MRST
DATA M
REQ M
CLK
CD MUTE
USB D+
USB D-
USB OC
IC7
BU3.3 / BU1.5V REG
IC5
LEVEL SHIFT
IC6
LEVEL SHIFT
MOTHER BOARD (X34- )
SO CCE MSTOP MRST
SI REQ BUCK MUTE L/R
USB+ USB­VBUS OC VBUS SW
Lch Rch
BU5V
Q9
DGND
INV
S1
S2
S3
AGND
LOS SW
12EJE SW
LOE SW
LO/EJ
MOTOR
S7.5V
S.GND
2
KDC-BT40U/BT645U KDC-U546BT

COMPONENTS DESCRIPTION

SWITCH UNIT (X16-678x-xx)

Ref. No. Application / Function Operation / Condition / Compatibility
IC2 Remote Control Sensor
Q20 Key Scan Timing Adjust When the base is Hi, key scan starts.
Q21 Grid Reversing Driver When the base is Hi, GRID1 is ON.
Q22 Grid Reversing Driver When the base is Hi, GRID2 is ON.
Q23 Grid Reversing Driver When the base is Hi, GRID3 is ON

ELECTRIC UNIT (X34-662x-xx)

Ref. No. Application / Function Operation / Condition / Compatibility
IC1 System μ-COM Controls FM/AM tuner, CD mechanism, Panel, volume and tone.
IC2 E-VOL Controls the source, volume and tone.
IC4 Power Supply IC Outputs 5Vx2, 8.3V, 10.2V, P-CON and P-ANT.
IC6 Power IC Amplifi es the front L/R and the rear L/R to 50W maximum.
IC7 RDS IC RDS decoder.
IC8 Reset IC Lo when detection voltage goes below 3.6V.
IC51 SW REG Power supply for D+5.1V. (to USB and panel)
IC52 Hi-side SW Detection of USB over-current.
IC501 Tuner IC (ATomIC) Tuner IC.
IC900 LPF Bluetooth outputs low pass fi lter.
IC901 D+3.3V AVR IC Power supply for BT+3.3V.
Q2,3 Servo+B AVR When Q3'base goes Hi, AVR outputs 7.5V.
Q11,12 Control SW for Servo+B ON when the base goes Hi.
Q13 Control SW for IC4 ON when the base goes Hi.
Q14 Control SW for IC4 ON when the base goes Lo.
Q53 FREQ CONT SW for IC51
Q101 ACC DET ON when the base goes Hi during ACC is applied.
Q102 Surge DET When the base goes Hi, surge voltage is detected.
Q103 BU DET ON when the base goes Hi during BU is applied.
Q104,105 Mute Control ON when the base goes Hi.
Q301 Panel 5V SW ON when the base goes Lo.
Q707~706 Pre-out Mute SW When a base goes Hi, Pre-out is muted.
Q707 Mute Driver for Pre-out ON when the base goes Lo.
Q901 BT Module Reset Control When the base goes Hi, BT module is reset.
Q902 Level Shift (5V→3.3V) Dual FET.
When the base goes Lo, switching frequency becomes 1.3MHz.
When the base goes Hi, switching frequency becomes 1.8MHz.

CD PLAYER UNIT (X32-6260-01)

Ref. No. Application / Function Operation / Condition / Compatibility
IC1 Mechanism μ-COM
IC2 Servo DSP with Built-in Audio DAC
IC3 4ch BTL Driver
IC4 iPod Authentication
Controls DSP and peripheral circuit.
USB host controller. (Compliant with Universal Serial Bus Specifi cation Rev2.0)
Built-in MP3·WMA·AAC decoder.
Built-in 1M-bit-SRAM.
Driver for focusing & tracking coil, driver for sled & spindle motor, and operation
for disc loading & ejection.
Connection authentication for iPod.
MFI341S2162: iPhone-compliant.
3
KDC-BT40U/BT645U KDC-U546BT
COMPONENTS DESCRIPTION
Ref. No. Application / Function Operation / Condition / Compatibility
IC5 3.3V→5.0V Level Shift Converts communication signal from 3.3V to 5.0V.
IC6 5.0V→3.3V Level Shift Converts communication signal from 5.0V to 3.3V.
IC7 BU1.5V / BU3.3V Regulator
IC8 E2PROM (Not used)
IC9 A3.3V Regulator Power supply for digital, analog and audio line.
Q3 D1.5V Output
Q5 B.3.3V Output
Q6 Control signal Inverter Controls Q5.
Q7 APC (Auto Power Control) Laser diode driver.
Q9 Control signal Inverter
D1 Laser Diode Protection
D2,3
Countermeasure against Static Elec-
tricity
Power supply for digital back-up.
Power supply for mechanism μ-COM.
Memory for ROM correction.
Countermeasure for software malfunction.
The output voltage in which the power supply that diverges from the BU1.5V line
is turned on and off is used as D1.5V.
The output voltage in which the power supply that diverges from the BU3.3V line
is turned on and off is used as D3.3V.
Because the detection logic of LOE/LIM_SW is different in the mechanism μ-COM
and the system μ-COM, the logic to the mechanism μ-COM side is reversed.
Prevents reverse bias which is applied to laser.
Laser destruction prevention.
The potential difference between DGND and AGND is absorbed, and the malfunc-
tion by static electricity is prevented.
4
KDC-BT40U/BT645U KDC-U546BT

MICROCOMPUTER’S TERMINAL DESCRIPTION

SYSTEM μ-COM : IC1 on X34- (ELECTRIC UNIT)
Truth Value
Pin No. Pin Name I/O Application
1~3 NC - Not used Output L fi xed
4 REMO I Remote control input Detects pulse width
5 NC - Not used Output L fi xed
6 BYTE - Setting of memory extension bus Connects to VSS
7 CNVSS -
8 XCIN - 32.768kHz
9 XCOUT - 32.768kHz
10 RESET - L: Reset
11 XOUT - 16.0MHz
12 VSS -
13 XIN - 16.0MHz
14 VCC1 -
15 NC - Not used Output L fi xed
16 LX REQ S I Communication request from slave unit
17 RDS CLK I RDS decoder clock input
18 PANEL DET I Panel communication detection H: Panel detached, L: Panel attached
19~22 NC - Not used Output L fi xed
23 RDS QUAL I RDS decoder qualifi cation input
24 F SYNC - Not used Output L fi xed
25 RDS DATA I RDS decoder data input
26 BEEP O Beep output 2kHz / 1kHz
27 TUN SCL I/O ATOMIC I2C clock output
28 TUN SDA I/O ATOMIC I2C data input/output
29 VFD SYS DATA O VFD data output
30 VFD PAN DATA I VFD data input
31 VFD CL O VFD clock output 125kHz
32 VFD BLK O VFD driver reset output
33 BT SYS DATA O Data output to Bluetooth
34 BT BT DATA I Data input from Bluetooth
35 NC - Not used Output L fi xed
36 ROTARY CW I VOL encoder input Detects pulse width
37 ROTARY CCW I VOL encoder input Detects pulse width
38 PON PANEL
39 EPM I Flash ROM EPM input
39 ROMCOR DET I E2PROM writing request H: Writing
40~43 NC - Not used Output L fi xed
44 VFD CE O VFD control request
45 S SYS DATA O Serial output to Bolero
46 S SOC DATA I Serial input from Bolero
I/O Panel 5V control
Table
Processing / Operation / Description
Connects to VSS
H: Rewritable (Only when fl ash ROM is used)
Communication begins after 500ms after VFD_BLK
becomes Hi.
H: Reset canceled, L: Reset, Momentary power-down
or panel detached or 11 minutes after ACC OFF: L
ON: L, Momentary power-down or panel detached or
11 minutes after ACC OFF: Hi-Z
L: Rewritable (Only when fl ash ROM is used)
Connects to VSS
5
KDC-BT40U/BT645U KDC-U546BT
MICROCOMPUTER’S TERMINAL DESCRIPTION
Truth Value
Pin No. Pin Name I/O Application
47 S SOC CLK I Serial clock input from Bolero
48 NC - Not used Output L fi xed
49 S SOC REQ I
50 CD LOS SW I CD loading detection
51 CD DISC12 SW I 12cm disc detection
52 SOC MUTE I SOC mute request L: Mute request, H: Normal
52 CD MUTE I CD mute request L: Mute request, H: Normal
53 SOC RST O SOC reset H: Normal, L: Reset
54 S SYS REQ O
55 NC - Not used Output L fi xed
56 CD MOTOR O CD motor control
57 CD LOEJ I/O CD motor control
58 SOC S STOP O SOC stop H: Normal, L: SOC stopped
59 CD LOE LIM SW I CD detection (Chucking SW) H: Loading completed, L: No disc
60 VCC2 -
61 NC - Not used Output L fi xed
62 VSS -
63~65 NC - Not used Output L fi xed
66 BT RST O Bluetooth module reset L: Normal, H: Bluetooth reset
67 PON FL O Key illumination power supply control H: ON, L: OFF
68 PS1 1 O Power supply IC control
69 PS1 2 O Power supply IC control
70 PS1 3 O Power supply IC control
71 PS2 1 O Power supply IC control
72 NC (PS2 2) - Not used Output L fi xed
73 BU DET I Momentary power-down detection BU found: L, No BU or momentary power-down: H
74 ACC DET I ACC power supply detection ACC found: L, No ACC: H
75 AUD SDA I/O I2C data input/output MAX 400kHz
76 AUD SCL I/O I2C clock input/output MAX 400kHz
77 NC - Not used Output L fi xed
78 FSEL O SW-REG frequency SW H: 2.04MHz, L: 1.68MHz
79 PON SWREG O SW-REG ON/OFF H: ON, L: OFF
80 LINE MUTE I Line mute detection Normal: Below 2.5V, NAVI mute: Over 2.5V
81 TYPE 1 I Destination SW
82 NC (TYPE 2) - Not used Output L fi xed
83 PWIC DC ERR I
84 AUD DC ERR I DC offset detection
85 TUN SMETER I S-meter input
86 NC - Not used Output L fi xed
Communication request from mecha-
nism to system μ-com
Communication request from system
μ-com to mechanism
Detection of power IC short-circuited
+B/GND
Table
q
q
w
w
w
w
Processing / Operation / Description
Refer to the truth value table
Refer to the truth value table
Refer to the truth value table
Refer to the truth value table
Refer to the truth value table
Refer to the truth value table
If DC offset is detected 20 times in 100ms with
condition below 1.0V, it will be judged as DC offset is
detected.
6
KDC-BT40U/BT645U KDC-U546BT
MICROCOMPUTER’S TERMINAL DESCRIPTION
Truth Value
Pin No. Pin Name I/O Application
87 PWIC MUTE O Power IC mute
88 NC - Not used Output L fi xed
89 PWIC STBY O Power IC standby control POWER ON: H, POWER OFF: L
90 MUTE I/O Mute L: Mute OFF, Hi-Z: Mute ON
91 LX MUTE I Mute request from slave unit H: Mute ON, L: Mute OFF
92 LX CON O Start-up request to slave unit H: Slave unit ON, L: Slave unit OFF
93 LX RST O Forced reset to slave unit H: Reset, L: Normal
94 AVSS -
95 LX REQ M O Communication request to slave unit
96 VREF -
97 AVCC -
98 LX DATA S I Data from slave unit
99 LX DATA M O Data to slave unit
100 LX CLK I/O LX-BUS clock
Table
Processing / Operation / Description
STANDBY source or momentary power-down: L,
TEL mute: L
• Truth value table
CD motor control
q
CD MOTOR (Pin 56) CD LOEJ (Pin 57)
Stop L L
Load H L
Eject H H
Brake H Hi-z
Power supply IC (IC4) control
w
SEL1 (Pin 10)
PS1-2 PS1-3 PS2-1 ILLUMI P-CON P-ANT
L L L OFF OFF OFF
L L H ON OFF OFF
H L H ON ON OFF
HHHONONON
SEL2 (Pin 11)
PS1-1 PS2-2
L L OFF OFF
H L ON OFF
H H ON ON
AUDIO/SW5
AM
7
KDC-BT40U/BT645U KDC-U546BT

TEST MODE

Example
Key Description of display Description
÷÷÷÷÷÷÷
A symbol “■” in the key column indicates that the key should be pressed and held.
Key Description of display Description
5
5
Disc Eject times
display
EJCNT :XXXXX
Disc Eject times display (Max. 65535 times).
While Disc Eject times is displayed, press and hold for 2
seconds or longer to clear Disc Eject times.
SEARCH
SRC
BAND
RETURN
How to enter the Test mode
Procedure Note
Press and hold the [1] key and [3] key and reset.
All lamps blinks when it is detected that the sub-clock resonator is disconnected.
When having started up in the Test mode, change the LINE MUTE inhibition time from 10 seconds to 1 second.
In the Test mode, do not write the detection information in the Data Flash ROM even if a DC Offset Error is detected.
Do not operate the DEMO mode in the Test mode, CD Mechanism Error Log Information Clear Mode, or DC Offset Error Detection Information
Clear Mode.
Also, when the source is STANDBY in the above mode, do not display DEMO ON/OFF switching items in the FUNCTION.
In the Test mode, the forced disc ejection operation is prohibited.
VOICE
EJECT
How to clear the Test mode
Procedure Note
Reset, Momentary power down, ACC OFF, Power OFF, Panel detached. Clearing the Test mode
Test mode default condition
Description Default values
Source STANDBY
Display Display lights are all turned on.
VOL -10dB (“30” is displayed.)
8
KDC-BT40U/BT645U KDC-U546BT
TEST MODE
Description Default values
BASS BOOST OFF
AUX ON1
SystemQ / dB EQ NATURAL (FLAT)
BEEP Beeps when the key is pressed briefl y.
PREOUT REAR
Test mode specifi cation in STANDBY source
Key Description of display Description
Common
(forward
rotation)
BAND
All lights ON.
System μ-com
version display
1
BT module version
display
Mechanism model
name and mecha-
nism version display
Design version
1
display mode
ON/OFF
2 Serial No. display
Power ON time
3
display
DISC operation
4
times
display
5
DISC EJECT times
display
5
Data Flash ROM
6
writing-in times
display
ROM correction
version display
Design version information display mode
(sub-mode) ON/OFF
SR0001 MR0001
<System μ-com> <Mechanism μ-com>
SR–––– MR––––
<System μ-com> <Mechanism μ-com>
SR
<System μ-com> <Mechanism μ-com>
÷÷÷÷÷÷÷
SYS0 1–3.00
BT :HXXXSXXX
9B30:
SN :00000000
PONTM :0 HXX
PONTM :XXXXX
CDTM :0H XX
CDTM :XXXXX
E
JCNT :XXXXX
DFCNT :XXXXX
∗∗∗∗
MR
∗∗∗∗
All lights ON.
System μ-com version display
BT module version display
Mechanism model name and mechanism version display
Press and hold this key for 1 second to display the design
version information.
Refer to “Design version information display mode” for the
details of display and operation procedure.
Serial No. displayed (8 digits)
The 00~50 is displayed for “xx”. When less than 1 hour,
displayed by increments of 10 minutes.
The 00001-10922 is displayed for “xxxxx”. MAX 10922 (hours)
The 00~50 is displayed for “xx”. When less than 1 hour,
displayed by increments of 10 minutes.
The 00001-10922 is displayed for "XXXXX". MAX 10922
(hours)
Disc Eject times display. MAX 65535 (times)
While disc EJECT times is displayed, press and hold for 2
seconds or longer to clear disc EJECT times.
The number of data writing-in the Data Flash ROM is
displayed. MAX 10000 (times)
The number is the ROM correction version number.
When not written in yet.
When data not matched
Due to the difference in versions.
9
KDC-BT40U/BT645U KDC-U546BT
Key Description of display Description
(The display blinks)
SEARCH I NG
BAND BT device search
Audio data
initialization
Clear the BT related
memory information
*1
XXXXXXXXXXXXX
UNKNOWN
AUD I O I N I T
INITIALIZE
BT INIT :OK
BT INIT :NG
TEST MODE
Press and hold this key for 1 second to initiate the BT device
search.
The search is terminated when 1 device is found.
When a device is found after the search, the name of that
device is displayed.
Only when no device is found after the search, press the
[ROTARY] key briefl y to re-initiate the search.
After the completion of the search, press and hold the [BAND]
key for 1 second to exit from the test mode.
Audio setting value is re-set to the Test mode default value.
Press and hold this key for 2 seconds.
The character string as shown in the left cell is displayed
while the BT related memory is being initialized.
This is to initialize the BT related memory to its factory de-
fault condition.
When the initialization is successfully completed, “OK” (up-
per) is displayed, and when the initialization is abnormally
completed, “NG” (lower) is displayed.
POFF –––
VOICE
VOICE Clear all of the CD information
SEARCH
SEARCH
RETURN
*1: This is a function to clear the information recorded in the fl ash memory, to clear the data fl ash ROM that has BT memory information to be
• Factory default condition
· To clear the pairing information (in the fl ash memory of the BT module)
· To clear the preset telephone numbers (in the data fl ash ROM)
· To write “KENWOOD BT CD/R-3P2” in the friendly name (in the fl ash memory of the BT module)
· To write “0000” in the PIN code (in the fl ash memory of the BT module)
Forced Power OFF
information display
POF F PNL
Transition to the CD information
CD information
display mode
ON/OFF
Information display
iPod authentication
IC installation
condition display
Preout switching
All lights ON /
All lights OFF
initialized with the “Data fl ash ROM clear” function, and to write the specifi c values in the ROM to initialize it to its factory default condition.
display mode (sub-mode)
iPod :
iPod :OK
iPod :NG
iPod :
SWPRE REAR
SWP RE SU B –W
÷÷÷÷÷÷÷
÷÷÷÷÷÷÷
No forced Power OFF
Forced power OFF by communication error between system
μ-com and panel.
While the forced power OFF data is displayed, press and
hold for 2 seconds to clear the data.
Refer to “CD information display mode” for the details of
display and operation procedure. Press [VOICE] key briefl y.
Press and hold this key for 2 seconds in the CD information
display mode to clear all of the CD information.
Press and hold the [VOICE] key.
iPod authentication IC installation condition display
When the display in the left cell is shown, press this key to
return to the normal display.
Blank: Searching and deciding the present status.
OK: Authentication IC has been installed.
NG: This is the iPod compatible model, but the
∗∗
authentication IC is not yet installed.
: This is not the iPod compatible model.
∗ ∗
Pressing and holding this key for 1 second switches the
preout.
Switch from “All lights ON” to “All lights OFF” and vice
versa.
10
KDC-BT40U/BT645U KDC-U546BT
TEST MODE
• CD information display mode (sub-mode)
Key Key Description of display Description
Mechanism error log 1 (Latest)
BAND
(forward
rotation)
CD mechanism error
/
log display
CD load error
/
information display
CD ejection error
/
information display
CD time code error
count information
/
display (Missing
counts)
CD time code error
count information
/
display (Count is not
updated.)
MECH A ER 1 :X X
MECH A ER 2 :X X
MECH A ER 3 :X X
LOAD ER1 :XX
LOAD ER2 :XX
EJ ECT ER1 :XX
EJ ECT ER2 :XX
EJ ECT ER3 :XX
EJ ECT ER4 :XX
CNT L OSE
CDDA :XX
CDROM :X X
CNT STAY
CDDA :XX
CDROM :X X
XX: Error number. The “--” is displayed in case there
is no error.
Mechanism error log 2 (Latest)
XX: Error number. The “--” is displayed in case there
is no error.
Mechanism error log 3 (Latest)
XX: Error number. The “--” is displayed in case there
is no error.
Load error switch 1
XX: The number of errors. The “--” is displayed in
case there is no error.
Load error switch 2
XX: The number of errors. The “--” is displayed in
case there is no error.
Ejection error switch 1
XX: The number of errors. The “--” is displayed in
case there is no error.
Ejection error switch 2
XX: The number of errors. The “--” is displayed in
case there is no error.
Ejection error switch 3
XX: The number of errors. The “--” is displayed in
case there is no error.
Ejection error switch 4
XX: The number of errors. The “--” is displayed in
case there is no error.
CD time code error count information (Missing
counts) mode is display.
Number of CD-DA error counts
XX: The number of errors. The “--” is displayed in
case there is no error.
CD-ROM (Compression fi le) number of count errors
XX: The number of errors. The “--” is displayed in
case there is no error.
CD time code error count information
(Count is not updated) mode display.
Number of CD-DA error counts
XX: The number of errors. The “--” is displayed in
case there is no error.
CD-ROM (Compression fi le) number of count errors
XX: The number of errors. The “--” is displayed in
case there is no error.
11
KDC-BT40U/BT645U KDC-U546BT
TEST MODE
• Design version information display mode (sub-mode)
Key Description of display Description
Destination terminal
condition display
BAND
(forward
rotation)
Test mode in Tuner source
If the following display is shown when the source is TUNER, it indicates an error.
TUNER IC
communication error
The adjustment is not
yet made.
Development ID
condition display
BT module address
BT module PIN code
Status Description of display Description
TYPE21 :1 1
0928WE2 –3.00
BTAD
PIN :
TUN CON NG
ERR
A 9 8.3 A
TYPE indicates μ-com destination, and indicates condition
of the destination terminal in real-time.
Development code - Version (system μ-com)
BT module address information display (in 12 digits)
(The display scrolls to display all of the digits)
BT module PIN code display
This display indicates the status in which the communication with
TUNER IC is not possible.
This display indicates the status in which the TUNER adjustment
has never been made (Adjustment value: 0X00 or 0XFF)
However the following TUNER test mode functions are valid (Note
that the display, “∗ERR∗” remains as it is.)
• TUNER band switching operation
Key Description of display Description
BAND
MODEL (KDC-) BAND1 BAND2 BAND3 BAND4 BAND5 BAND6 Description
BAND switching
operation
BT645U
BT40U
U546BT
q
q
q
FM1–4 A 98.3A
FM1 FM2 FM3
FM1 FM2 FM3
FM1 FM2 FM3
AM
w
MW/LW
w
MW
w
Every time when the [BAND] key is pressed, the BAND is
switched as listed in the next table for each TYPE.
q
w
q
w
e
SW1
r
SW2
q
w e
r
• Switch in injection setting / packs setting
In the TUNER FM source, every time the [5] key is pressed and held for 1 second the injection setting switches in the following sequence of
order: AUTO → H → L → AUTO.
In the TUNER FM source, every time the [6] key is pressed and held for 1 second the packs setting switches in the following sequence of order:
AUTO → 1 → 2 → . . . 7 → AUTO.
In both settings, the default condition is AUTO, which is displayed as shown in the next table.
Key Description of display Description
5
6
Injection setting
switching
Packs setting
switching
FM1–4 A 98.1A
FM1–4 A 98.1H
FM1 – 4 A 9 8.1 L
FM1–4 A 98.1A
FM1–4 7 98.1A
A: Injection setting AUTO
H: Injection setting H
L: Injection setting L
A: Packs setting AUTO
X: Packs setting 1~7
12
KDC-BT40U/BT645U KDC-U546BT
TEST MODE
• TUNER setting adjustment mode
This mode is to adjust TUNER setting.
Key Note
Press this key to change the mode to the TUNER setting adjustment (Press and hold the key for 1 second).
VOICE
Procedures in the TUNER setting adjustment mode are as follows:
• Adjustment mode switching (AUTO/MANUAL)
(forward
rotation)
When the source is FM, frequency is switched to 98.3MHz at the start of the adjustment mode.
Press and hold the [VOICE] key.
Key Description of display Description
Level Offset
adjustment (Auto)
BAND
Level Offset
adjustment (Manual)
A S–XX L–XX
M S–XX L –XX
Press and hold the [BAND] key for 1 second to select the
TUNER adjustment method (A: AUTO / M: MANUAL).
S-XX → Present S meter value (HeX)
L-XX → Level offset value (HeX)
When the level offset value is not yet adjusted (0XFF or
0X00), “--” is displayed.
• Procedure in the AUTO adjustment mode
Key Description of display Description
ROTARY
RETURN
In automatic
adjustment
Completion of
automatic adjustment
Save the adjustment
value.
Failure of the
automatic adjustment
Cannot save the
adjustment value.
Save the failed value
(0XFF).
Mode clear
A S–XX L–XX
ADJ OK :XX
(Level offset value)
ADJ NG
FM1–4 A 97.9A
ERR
A97.9A
Press this key briefl y to start the automatic adjustment.
After the completion of the automatic adjustment, save the
level offset value in the Data Flash ROM and display the
resultant level offset value (HeX).
Display shown when the automatic adjustment failed
(Write OXFF in the Data Flash ROM. → Given the OXFF
saved in the ROM, the adjustment starts with “--” when the
automatic adjustment mode is re-started.)
This is to clear the FST adjustment mode (in normal
operation) (The display returns to the normal display and the
test mode is retained.) Frequency is switched to 97.9MHz.
This is to clear the FST adjustment mode (when failed in the
automatic adjustment) (The display returns to the normal
display and the test mode is retained.)
Frequency is switched to 97.9MHz.
• Procedure in MANUAL adjustment mode
Key Description of display Description
/
/
ROTARY
Level Offset
adjustment (Manual)
Completion of the
adjustment value
saving
Failed to save the
adjustment value
M S–XX L –XX
ADJ OK :XX
(Level offset value)
ADJ NG
Press [/] key for 500ms or longer to continuously increase / decrease the adjustment value.
Display when the adjustment value has been saved in
the Data Flash ROM
The saved level offset value (HeX) is displayed.
Display when the adjustment value has not been saved
in the Data Flash ROM
13
Loading...