Kenmore 79681392610, 79681393610, 79691392610, 79691393610 Owner’s Manual

Use & Care Guide

Manual de Uso y Cuidado

English / Español

Models/Modelos: 796.8139*, 796.9139*

Kenmore® Steam Dryer

Secador con vapor

* = color number, número de color

MFL67731087

Sears Brands Management Corporation

Ho man Estates, IL 60179 U.S.A.

www.kenmore.com

www.sears.com

Sears Canada Inc.

Toronto, Ontario, Canada M5B 2C3

www.sears.ca

®

TABLE OF CONTENTS

 

 

IMPORTANT SAFETY INSTRUCTIONS ....................

 

3-6

GROUNDING REQUIREMENTS ...................................

 

4

FEATURES AND BENEFITS

 

 

Key Parts and Components ........................................

 

7

INSTALLATION INSTRUCTIONS

 

 

Key Dimensions and Specifications ..........................

 

8

Location Requirements ................................................

 

8

Choose the Proper Location .......................................

 

8

Clearances ....................................................................

 

8

Installation with Optional Pedestal Base

 

 

or Stacking Kit .............................................................

 

9

Optional Accessories ..................................................

 

9

Connecting Gas Dryers ........................................

 

10-11

Gas Requirements ...............................................

 

10

Electrical Requirements for Gas Models Only .... 10

Connecting Electric Dryers .................................

 

12-13

Electrical Requirements.......................................

 

12

Venting the Dryer .................................................

 

14-15

Connecting the Inlet Hose.........................................

 

16

Leveling the Dryer .....................................................

 

17

Reversing the Door Swing ........................................

 

17

Moving the Control Panel ....................................

 

18-19

Final Installation Check ...........................................

 

20

HOW TO USE

 

 

Control Panel Features .............................................

 

21

Operating the Dryer .................................................

 

22

Sorting Loads .............................................................

 

23

Loading the Dryer .....................................................

 

23

Cycle Guide ........................................................

 

24-25

Time and Status Display .........................................

 

26

Cycle Modifier Buttons ............................................

 

27

Cycle Options and Special Features .....................

 

28

Wrinkle Guard ...................................................

 

28

Control Lock .......................................................

 

28

Damp Dry Signal ................................................

 

28

Energy Saver .......................................................

 

28

Installing and Using the Drying Rack...............

 

28

Steam Features .........................................................

 

29

Steam Cycle Guide...................................................

 

30

USER MAINTENANCE INSTRUCTIONS

 

 

Regular Cleaning ......................................................

 

31

Cleaning the Exterior ..........................................

 

31

Cleaning the Interior ...........................................

 

31

Cleaning Around and Under the Dryer

............31

Cleaning the Lint Filter .......................................

 

31

Maintaining the Exhaust System..............................

 

32

DIAGNOSTICS...............................................................

 

33

TROUBLESHOOTING GUIDE

 

 

FAQs ...........................................................................

 

34

Before Calling for Service ................................

 

34-37

WARRANTY ...................................................................

 

38

SERVICE..........................................................

Back Cover

PRODUCT RECORD

 

 

In the space below, record the date of purchase, model,

and serial number of your product. You will find the

model and serial number printed on an identification

plate located inside the dryer door. Have these items of

information available whenever you contact Sears

concerning your product.

 

 

Model No.

 

 

Date of Purchase

 

 

Serial No.

 

 

Save these instructions and your sales receipt for future reference.

PROTECTION AGREEMENTS

Master Protection Agreements

Congratulations on making a smart purchase. Your new Kenmore® product is designed and manufactured for years of dependable operation. But like all products,

it may require preventive maintenance or repair from time to time. That’s when having a Master Protection Agreement can save you money and aggravation.

The Master Protection Agreement also helps extend the life of your new product. Here’s what the Agreement* includes:

Parts and labor not just for repairing defects, but to help keep products operating properly under normal use. Our coverage goes well beyond the product warranty. No deductibles, no functional failure excluded from coverage – real protection.

Expert service by experienced service technicians trusted in millions of homes every year.

Unlimited service calls and nationwide service, as often as you want us, whenever you want us.

“No-lemon” guarantee – replacement of your covered product after three separate product failures occur within twelve months and a fourth repair is required. Includes free delivery and installation, if necessary, of replacement product.

Product replacement if your covered product can’t be fixed.

Annual Preventive Maintenance Check at your request

– no extra charge.

Fast help by phone—phone support from a service agent on all products to help troubleshoot problems. Think of us as a “talking owner’s manual.”

Power surge protection against electrical damage due to power fluctuations.

$300 food loss protection for any food spoilage that is the result of mechanical failure of any covered refrigerator or freezer.

Service Promise: $50 if first attempt repair of your covered product can’t be accomplished and product is not usable while awaiting further repair service.

25% discount o the regular price of any non-covered repair service and related installed parts.

Once you purchase the Agreement, a simple phone call is all that it takes for you to schedule service. You can call anytime day or night.

The Master Protection Agreement is a risk-free purchase. If you cancel for any reason during the product warranty period, we will provide a full refund, or a prorated refund anytime after the product warranty period expires.

Purchase your Master Protection Agreement today!

Some limitations and exclusions apply.

For prices and additional information in the U.S.A. call 1-800-827-6655.

*Coverage in Canada varies on some items.

For full details call Sears Canada at 1-800-361-6665.

Sears Installation Service

For Sears professional installation of home appliances, garage door openers, water heaters, and other major home items, in the U.S.A. call 1-844-553-6667, and in

2 Canada call 1-800-469-4663.

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

Your safety and the safety of others is very important.

We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol.

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word DANGER or WARNING. These words mean:

DANGER: Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING: Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION: Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire, explosion, or electric shock, or to prevent property damage, personal injury,

or loss of life.

WARNING

FIRE HAZARD

Failure to follow safety warnings exactly could result in serious injury, death or property damage.

Do not install a booster fan in the exhaust duct.

Install all clothes dryers in accordance with the installation instructions of the manufacturer of the dryer.

WARNING

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, death or property damage.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WHAT TO DO IF YOU SMELL GAS:

1.Do not try to light a match or cigarette, or turn on any gas or electrical appliance.

2.Do not touch any electrical switches. Do not use any phones in your building.

3.Clear the room, building, or area of all occupants.

4.Immediately call your gas supplier from a neighbor’s phone. Carefully follow the gas supplier’s instructions.

5.If you cannot reach your gas supplier, call the fire department.

Do not install a clothes dryer with flexible plastic venting materials. If a flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with clothes dryers. Flexible venting materials are known to collapse, be easily crushed, and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.

SAVE THESE INSTRUCTIONS

3

IMPORTANT SAFETY INSTRUCTIONS

BASIC SAFETY PRECAUTIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Read all instructions before using the dryer.

Before use, the dryer must be properly installed, as described in this manual.

Do not place items exposed to cooking oils in your dryer. Items contaminated with cooking oils may contribute to a chemical reaction that could cause a load to catch fire.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances, as they give o vapors that could ignite or explode.

Do not reach into the dryer if the drum or any other part is moving.

Do not repair or replace any part of the dryer or attempt any servicing unless specifically recommended in this Use and Care Guide or in published user-repair instructions that you understand and have the skills to carry out.

Do not tamper with controls.

Before the dryer is removed from service or discarded, remove the door to the drying compartment.

Do not allow children to play on or in the dryer. Close supervision of children is necessary when the dryer is used near children.

Do not use fabric softeners or products to eliminate static unless recommended by the manufacturer of the fabric softener or product.

Do not use heat to dry articles containing foam rubber or similarly textured rubber-like materials.

Keep area around the exhaust opening and adjacent surrounding areas free from the accumulation of lint, dust, and dirt.

The interior of the dryer and exhaust vent should be cleaned periodically by qualified service personnel.

Do not install or store the dryer where it will be exposed to the weather.

Always check the inside of the dryer for foreign objects.

Clean the lint filter before or after each load.

WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling.

CALIFORNIA SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

This act requires the Governor of California to publish a list of substances known to the state to cause cancer, birth defects, or other reproductive harm and requires businesses to warn customers of potential exposure

to such substances. Gas appliances can cause minor exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde, and soot, caused primarily by the incomplete combustion of natural gas or LP fuels.

Properly adjusted dryers will minimize incomplete combustion. Exposure to these substances can be minimized further by properly venting the dryer to the outdoors.

GROUNDING REQUIREMENTS

This appliance must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance must be

equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

WARNING: Improper connection of the equipment-grounding

conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance. If it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance must be connected to a grounded metal, permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the appliance. Electrical shock can result if the dryer is not properly grounded.

4

IMPORTANT SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS FOR INSTALLATION

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

• Properly ground dryer to conform with all governing

• Remove all packing items and dispose of all shipping

codes and ordinances. Follow details in the installation

materials properly. Failure to do so can result in death,

instructions. Electrical shock can result if the dryer is not

fire, explosion, burns, or death.

properly grounded.

• Place dryer at least 18 inches above the floor for a

• Before use, the dryer must be properly installed as

garage installation. Failure to do so can result in fire,

described in this manual. Electrical shock can result if

explosion, burns, or death.

the dryer is not properly grounded.

• Keep all packaging from children. Packaging material

• Install and store the dryer where it will not be exposed

can be dangerous for children. There is a risk of

to temperatures below freezing or exposed to

su ocation.

the weather.

• Do not install near items that produce heat or open

• All repairs and servicing must be performed by an

flame such as stoves or cooking ovens. Failure to follow

authorized service technician unless specifically

this warning can cause product deformation, smoke and

recommended in this Use & Care Guide. Use only

fire.

authorized factory parts. Failure to follow this warning

• Do not place candles or cigarettes on top of the

can cause serious injury, fire, electrical shock, or death.

• To reduce the risk of electrical shock, do not install the

product. Failure to follow this warning can cause

product deformation, smoke and fire.

dryer in humid spaces. Failure to follow this warning

• Remove all protective vinyl film from the product.

can cause serious injury, fire, electrical shock, or death.

• Connect to a properly rated, protected, and sized

Failure to do so can cause product deformation, smoke

and fire.

power circuit to avoid electrical overload. Improper

 

power circuits can melt, creating risk of electrical shock

 

and/or fire hazard.

 

Exhaust/Ducting:

Gas dryers MUST be exhausted to the outside. Failure to follow these instructions can result in fire or death.

The dryer exhaust system must be exhausted to the outside of the dwelling. If the dryer is not exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

Use only rigid metal or flexible metal 4-inch diameter duct inside the dryer cabinet or for exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation.

Ductwork is not provided with the dryer, and you should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer.

Failure to follow these instructions can result in fire or death.

Rigid or semi rigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will a ect drying time. Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the e ciency of the exhaust system. Secure all joints with duct tape. For complete details, follow the Installation Instructions. Failure to follow these instructions can result in fire or death.

5

IMPORTANT SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS FOR STEAM FUNCTIONS

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not open the dryer door during steam cycles.

Failure to follow these instructions can result in a burn hazard.

Do not dry articles that have been previously cleaned in, washed in, soaked in, or spotted with gasoline, dry-cleaning solvents, or other flammable or explosive substances, as they give o vapors that could ignite or explode. Failure to follow these instructions can result in fire or death.

Do not fill the steam feeder with gasoline, drycleaning solvents, or other flammable or explosive substances. Failure to follow these instructions can result in fire or death.

Do not touch the steam nozzle in the drum during or after the steam cycle. Failure to follow these instructions can result in a burn hazard.

Do not fill the steam feeder with hot water (over 86°F/30°C). Failure to follow these instructions can result in a burn hazard.

SAFETY INSTRUCTIONS FOR CONNECTING ELECTRICITY

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Do not, under any circumstances, cut or remove the ground prong from the power cord. To prevent personal injury or damage to the dryer, the electrical power cord must be plugged into a properly grounded outlet.

For personal safety, this dryer must be properly grounded. Failure to do so can result in electrical shock or injury.

Refer to the installation instructions in this manual for specific electrical requirements for your model.

Failure to follow these instructions can create an electrical shock hazard and/or a fire hazard.

This dryer must be plugged into a properly grounded outlet. Electrical shock can result if the dryer is not properly grounded. Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded. Failure to follow these instructions can create an electrical shock hazard and/or a fire hazard.

The dryer should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate. This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

Never unplug your dryer by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet. The power cord can be damaged, resulting in a risk of fire and electrical shock.

Repair or replace immediately all power cords that have become frayed or otherwise damaged. Do not use a cord that shows cracks or abrasion damage along its length or at either end. The power cord can melt, creating electrical shock and/or fire hazard.

When installing or moving the dryer, be careful not to pinch, crush, or damage the power cord. This will prevent injury and prevent damage to the dryer from fire and electrical shock.

SAVE THESE INSTRUCTIONS

6

Kenmore 79681392610, 79681393610, 79691392610, 79691393610 Owner’s Manual

FEATURES AND BENEFITS

KEY PARTS AND COMPONENTS

There are several important components that are referenced in this manual.

AEASY-TO-USE CONTROL PANEL

Rotate the cycle selector knob to select the desired dry cycle. Add cycle options or adjust settings with the touch of a button.

BTIME AND STATUS DISPLAY

The easy-to-read LED display shows cycle status and estimated time remaining.

CCYCLE MODIFIERS

Adjust the cycle settings such as temperature and dry level with the touch of a button.

NOTE: Not all settings are available for all cycles.

DCHECK VENT

(Duct Blockage Sensing System)

The Check Vent (Duct blockage sensing system) detects and alerts you to blockages in the exhaust system that reduce airflow from the dryer. Maintaining clean exhaust system ducts improves operating e ciency and helps minimize service calls, saving you money.

EULTRA-CAPACITY DRUM

The ultra-large drum o ers superior durability.

FEASY-ACCESS REVERSIBLE DOOR

The wide-opening, see-through glass door provides easy access for loading and unloading. Door swing can be reversed to adjust for installation location.

GFRONT-MOUNT LINT FILTER

The front-mount lint filter allows for easy access and cleaning between loads.

HLEVELING FEET

Four leveling feet (two in front, and two in back) adjust to improve dryer stability on uneven floors.

B

E

A D

C

 

F

 

G

H

 

Power Cord

Terminal Block

Location

Access Panel

(Gas Models)

(Electric Models)

 

Exhaust Duct

Gas Connection Outlet

Location

(Gas Models)

Rear of Dryer

7

INSTALLATION INSTRUCTIONS

KEY DIMENSIONS AND SPECIFICATIONS

Description

Dryer (Gas and Electric)

Electrical Requirements

Refer to the rating label

Gas Requirements* NG:

4–10.5 inches WC (Water Column)

Gas Requirements* LP:

8–13 inches WC

Dimensions

27 in. (W) X 32.1 in. (D) X 40.8 in. (H), 49.4 in. (D with door open)

 

68.6 cm (W) X 81.5 cm (D) X 103.6 cm (H), 125.5 cm (D with door open)

Net Weight

Electric : 127.9 lb. (58 kg) Gas : 131 lb. (59.4 kg)

 

 

Drying Capacity

IEC 7.3 cu. ft.

*Gas Models Only

LOCATION REQUIREMENTS

IMPORTANT: Read all installation instructions completely before installing and operating your dryer. It is important that you review this entire manual before installing and using your dryer. It contains detailed instructions concerning electrical connections, gas connections and exhaust requirements.

CHOOSE THE PROPER LOCATION

Store and install the dryer where it will not be exposed to temperatures below freezing or exposed to outdoor weather conditions.

Choose a location with a solid, level floor.

If the dryer is being installed in a garage, place the dryer at least 18 inches (45.7cm) above the floor.

Properly ground the dryer to conform with all governing codes and ordinances.

To reduce the risk of electric shock, do not install the dryer in damp or wet locations.

NOTE: Installing the dryer in a humid space, or installing or storing the dryer where it will be exposed to the weather or freezing temperatures, may result in rust or other damage that is not covered by the product warranty.

IMPORTANT: If you are installing your dryer in a manufactured or mobile home, please refer to the

Special Electrical Requirements for Mobile or Manufactured Homes section.

CLEARANCES

Most installations require a minimum 4 inch (10 cm) clearance behind the dryer for the exhaust ducting.

Allow minimum clearances of at least 1 inch (2.5 cm) on the sides and back to minimize vibration and noise.

Allowing additional clearance for installation and servicing is recommended.

Be sure to allow for wall, door, or floor moldings that may increase the required clearances.

Allow at least 17 ½ inches (44.5 cm) in front of the dryer to open the door.

Standard Installation – Side View

17 3/8 in.

(43.9 cm)

32 1/8 in.

(81.5 cm)

49 3/8 in.

(125.5 cm)

Standard Installation – Front View

4 in.

 

 

(10 cm)

 

 

1"

27"

1"

(2.5 cm)

(68.6 cm)

(2.5 cm)

3" (7.6 cm)

Vent

48 sq. in.

(310 sq. cm. )

Vent

24 sq. in.

(155 sq. cm. )

3" (7.6 cm)

Additional instructions for closet installations:

The closet door must allow for su cient airflow. Refer to the diagram above for minimum vent opening requirements. A louvered door is also acceptable.

8

INSTALLATION INSTRUCTIONS

INSTALLATION WITH OPTIONAL PEDESTAL BASE OR STACKING KIT

IMPORTANT: If you are installing your dryer using an optional pedestal base or stacking kit, refer to the instructions included with the accessory.

Required Dimensions for

Required Dimensions for

Installation with Pedestal

Installation with Stacking Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55 7/8 in.

 

(141.7 cm)

 

32 1/8 in.

4 in.

(10 cm)

(81.5 cm)

 

(207.381 5/8"cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1"

 

 

 

 

 

 

 

27"

 

 

 

 

 

1"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(2.5 cm)

 

 

(68.6 cm)

 

 

 

(2.5 cm)

ACCESSORIES

Included Accessories

Y connector

short hose

(steam models)

(steam models)

Optional Accessories

drying rack

side vent kit

(sold separately)

(sold separately)

No. 3750EL0001C

Kit No. D26-49670

Required Accessories

long hose (sold separately) (steam models)

LP conversion kit

Use a pedestal to make

No. D26-17025

laundry easier to reach.

 

White = 796.51022

 

Metallic Silver = 796.51023

Use the stacking kit to mount the dryer on top of

WKH ZDVKHU WR VDYH pRRU space.

Chrome Look = D26 17013

Use the LP conversion kit for changing the dryer gas connections from natural gas (NG) to propane gas (LP). NOTE: Installation of the LP conversion kit must be performed by a qualified service technician.

9

INSTALLATION INSTRUCTIONS

CONNECTING GAS DRYERS

GAS REQUIREMENTS (GAS MODELS ONLY)

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including

the following:

Gas supply requirements: As shipped from the factory, this dryer is configured for use with natural gas (NG). It can be converted for use with propane (LP) gas. Gas pressure must not exceed 8 inches water column for (NG), or 13 inches water column for (LP).

A qualified service or gas company technician must connect the dryer to the gas service. Failure to follow these instructions can result in fire, explosion, or death.

Isolate the dryer from the gas supply system by closing its individual manual shuto valve during any pressure testing of the gas supply. Failure to do so can result in fire, explosion, or death.

Supply line requirements: Your laundry room must have a rigid gas supply line to your dryer. In the United States, an individual manual shuto valve MUST be installed within at least 6 ft. (1.8 m) of the dryer, in accordance with the National Fuel Gas Code ANSI Z223.1 or Canadian gas installation code CSA B149.1. A ⅛ inch NPT pipe plug must be installed.

Failure to do so can result in fire, explosion, or death.

If using a rigid pipe, the rigid pipe should be ½ inch IPS. If acceptable under local codes and ordinances and when acceptable to your gas supplier, ⅜ inch approved tubing may be used where lengths are less than 20 ft. (6.1 m). Larger tubing should be used for lengths in excess of 20 ft. (6.1 m). Failure to do so can result in fire, explosion, or death.

Connect the dryer to the type of gas shown on the nameplate. Failure to do so can result in fire, explosion, or death.

To prevent contamination of the gas valve, purge the gas supply of air and sediment before connecting the gas supply to the dryer. Before tightening the connection between the gas supply and the dryer, purge remaining air until the odor of gas is detected.

Failure to do so can result in fire, explosion, or death.

DO NOT use an open flame to inspect for gas leaks. Use a noncorrosive leak detection fluid. Failure to do so can result in fire, explosion, or death.

Use only a new AGAor CSA-certified gas supply line with flexible stainless steel connectors. Failure to do so can result in fire, explosion, or death.

Securely tighten all gas connections. Failure to do so can result in fire, explosion, or death.

Use Teflon tape or a pipe-joint compound that is insoluble in propane (LP) gas on all pipe threads.

Failure to do so can result in fire, explosion, or death.

DO NOT attempt any disassembly of the dryer; disassembly requires the attention and tools of an authorized and qualified service technician or

company. Failure to follow this warning can result in fire, explosion, or death.

ELECTRICAL REQUIREMENTS FOR GAS MODELS ONLY

WARNING: ELECTRIC SHOCK HAZARD

Failure to follow safety warnings could result in serious injury or death.

The power cord of this dryer is equipped with a 3-prong (grounding) plug for protection against shock hazard and should be plugged directly into a properly grounded 3-prong receptacle. Failure to

follow this warning can result in fire, explosion, or death.

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. Failure to follow this warning can result in fire, explosion, or death.

For personal safety, this dryer must be properly grounded. Failure to follow this warning can result in fire, explosion, or death.

This dryer must be plugged into a 120-VAC, 60-Hz. grounded outlet protected by a 15-ampere fuse or circuit breaker. Failure to follow this warning can result in fire, explosion, or death.

Where a standard 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet. Failure to follow this warning can result in fire, explosion, or death.

3-prong grounding type wall receptacle

Ensure proper ground exists before use.

3-prong grounding

plug

10

CONNECTING GAS DRYERS (continued)

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including

the following:

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Failure to do so can result in fire, explosion, or death.

Use only a new stainless steel flexible connector and a new AGA-certified connector. Failure to do so can result in fire, explosion, or death.

A gas shuto valve must be installed within 6 ft. (1.8 m) of the dryer. Failure to do so can result in fire, explosion, or death.

The dryer is configured for natural gas when shipped from the factory. Make sure that the dryer is equipped with the correct burner nozzle for the type of gas being used (natural gas or propane gas).

Failure to do so can result in fire, explosion, or death.

Connecting the Gas Supply

NOTE: This dryer is configured from the factory set for natural gas (NG). If dryer is to be used with propane (LP) gas, it must be converted by a qualified

service technician.

1Make sure that the gas supply to the laundry room is turned OFF and the dryer is unplugged. Confirm that the type of gas available in your laundry room is appropriate for the dryer.

2Remove the shipping cap from the gas fitting at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap.

3Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector with a ⅜ inches NPT fitting.

NOTE: DO NOT use old connectors.

4Securely tighten all connections between the dryer and your laundry room’s gas supply.

5Turn on the gas supply.

6Check all pipe connections (both internal and external) for gas leaks with a noncorrosive leak-detection fluid.

7Proceed to Venting the Dryer.

INSTALLATION INSTRUCTIONS

If necessary, the correct nozzle (for the LP nozzle kit, order part number 383EEL3002D) should be installed by a qualified technician and the change should be noted on the dryer. Failure to do so can result in fire, explosion, or death.

All connections must be in accordance with local codes and regulations. Failure to do so can result in fire, explosion, or death.

Gas dryers MUST exhaust to the outdoors. Failure to do so can result in fire, explosion, or death.

ë LQ 137 Gas

ê LQ 137 3LSH 3OXJ

CRQQeFWLRQ

 

AGA/CSA-CHUWLoeG GDV 6XSSO\

SWDLQOHVV SteHO )Oe[LEOH 6KXWRç VDOve

CRQQector

High-Altitude Installations

The BTU rating of this dryer is AGA-certified for elevations below 10,000 feet.

If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician or gas supplier.

11

INSTALLATION INSTRUCTIONS

CONNECTING ELECTRIC DRYERS ELECTRICAL REQUIREMENTS

WARNING: To help prevent fire, electrical shock, serious injury, or death, the wiring

and grounding must conform to the latest edition of the National Electrical Code, ANSI/NFPA 70 and all applicable local regulations. Please contact a qualified electrician to check your home’s wiring and fuses to ensure that your home has adequate electrical power to operate the dryer.

Special Electrical Requirements for Mobile or Manufactured Homes

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:

Any installation in a manufactured or mobile home must comply with the Manufactured Home

Construction and Safety Standards Title 24 CFR, Part 3280 or Standard CAN/CSA Z240 MH and local codes and ordinances.

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996. Failure to do so can result in fire, explosion, or death.

Electrical Requirements for Electric Models Only

WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including

the following:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor must be run with the circuit conductors and connected to the equipment grounding terminal or lead on the dryer. Failure to do so can result in fire, explosion, or death.

The dryer has its own terminal block that must be connected to a separate 240 VAC, 60-Hertz, single phase circuit, fused at 30 amperes (the circuit must be fused on both sides of the line). ELECTRICAL SERVICE FOR THE DRYER SHOULD BE OF THE MAXIMUM RATE VOLTAGE LISTED ON THE NAMEPLATE. DO NOT CONNECT DRYER TO 110-, 115-, OR 120-VOLT CIRCUIT. Failure to follow these instructions can result in fire, explosion, or death.

If branch circuit to dryer is 15 ft. (4.5 m) or less in length, use UL (Underwriters Laboratories) listed No.- 10 AWG wire (copper wire only), or as required by local codes. If over 15 ft. (4.50 m), use UL-listed No.-8 AWG wire (copper wire only), or as required by local codes. Allow su cient slack in wiring so dryer can be moved from its normal location when necessary.

Failure to do so can result in fire, explosion, or death.

The power cord (pigtail) connection between wall receptacle and dryer terminal block IS NOT supplied with the dryer. Type of pigtail and gauge of wire must conform to local codes and with instructions on the following pages. Failure to follow these instructions can result in fire, explosion, or death

A 4-wire connection is required for all new construction after January 1, 1996. A 4-wire connection must be used where local codes do not permit grounding through the neutral wire. Failure to do so can result in fire, explosion, or death.

12

INSTALLATION INSTRUCTIONS

CONNECTING ELECTRIC DRYERS (continued)

WARNING:

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral wire is prohibited for: (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral wire.

Four-Wire Power Cord

• A 4-wire connection is required for all

mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

Use a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

4 Wire

Power

Cord

1Remove the terminal block access cover on the upper back of the dryer.

2Install a UL-listed strain relief into the power cord through-hole.

3Thread a 30-amp, 240-volt, 4-wire, UL-listed power cord with #10 AWG-minimum copper conductor through the strain relief.

Hot

Neutral

Hot

(Black)

(White) (Red)

Green Ground Screw

 

Neutral

Green Wire of

 

 

Grounding

Power Cord

 

Wire

4Transfer the neutral grounding wire from behind the green ground screw to the center screw of the terminal block.

5Attach the two hot leads (black and red) of the power cord to the outer terminal block screws.

6Attach the power cord white neutral wire to the center screw of the terminal block.

7Attach the power cord ground wire to the green ground screw.

8TIGHTEN ALL SCREWS SECURELY.

9Reinstall the terminal block access cover.

Three-Wire Power Cord

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

• A UL-listed strain relief is required.

Use a 30-amp, 240-volt, 3-wire, UL-listed power cord with #10 AWG-minimum copper conductor and closed loop or forked terminals with upturned ends.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

3 Wire

Power

Cord

1Remove the terminal block access cover on the upper back of the dryer.

2Install a UL-listed strain relief into the power cord through-hole.

3Thread a 30-amp, 240-volt, 3-wire, UL-listed power cord with #10 AWG-minimum copper conductor through the strain relief.

Neutral

 

 

Hot

Grounding

Hot

Neutral

Wire

(Black)

(White)

(Red)

Green Ground Screw

External Ground Wire

4Attach the two hot leads (black and red) of the power cord to the outer terminal block screws.

5Attach the power cord neutral (white) wire to the center terminal block screw.

6Connect the external ground (if required by local codes) to the green ground screw.

7TIGHTEN ALL SCREWS SECURELY.

8Reinstall the terminal block access cover.

13

Loading...
+ 29 hidden pages