If you have questions when
installing, operating or
maintaining your reverse
osmosis system, call this
toll-free number...
1-800-426-9345
(M - F, 7 am - 8 pm, CST)
For repair or replacement
parts, call this toll-free num
ber. ..
1-800-366-7278
See back cover for other
Sears service numbers.
WWW. Ken more Wate r.com
SAVE THIS MANUAL
Reverse Osmosis
Drinking Water System
♦ Warranty
♦ Flow To Install
♦ How It Works
♦ Care Of
♦ Repair Parts
System tested and certified by NSF International
to NSF/ANSI Standard 58 for the reduction of the
claims specified on the performance data sheet.
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U. S. A.
PRINTED IN U.S.A.Part No. 7266615 (Rev. F 8/4/05)
WARRANTY -
FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM
(except filter cartridges and R. O. membrane)
For one year from the date of purchase, when the Reverse Osmosis Drinking Water System is installed
and maintained in accordance with our instructions, Sears will repair, free of charge, defects in material
and workmanship, except filter cartridges and the R. O. membrane.
TO OBTAIN WARRANTY SERVICE, SIMPLY CONTACT THE NEAREST SEARS SERVICE CENTER
THROUGHOUT THE UNITED STATES, This warranty applies only while this product is in use in the
United States.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
Sears, Roebuck and Co., D/817 WA, Hoffman Estates, IL 60179
All installation labor arranged by Sears shall be per
formed in a neat, workmanlike manner in accor
dance with generally accepted trade practices. Fur
ther, all installations shall comply with all local laws,
codes, regulations, and ordinances. Customer shall
also be protected during installation by insurance re
lating to Property Damage, Workman's Compensa
tion and Public Liability.
SEARS INSTALLATION WARRANTY
In addition to any warranty extended to you on the
Sears merchandise involved, which warranty be
comes effective the date the merchandise is installed,
should the workmanship of any Sears arranged
installation prove faulty within one year. Sears will,
upon notice from you, cause such faults to be cor
rected at no additional cost to you.
I
- SAFETY GUIDES -
Read all steps and guides carefully before instal
ling and using your reverse osmosis system. Follow
all steps exactly to correctly install. Reading this
manual will also help you to get all the benefits from
the reverse osmosis system.
^ Do not attempt to use this product to make safe
drinking water from non-po table water sources. Do
not use the system on microbiologically unsafe wa
ter, or water of unknown quality without adequate
disinfection before or after the system. This system
is certified for cyst reduction and may be used on
disinfected water that may contain filterable cysts.
^ Check with your local public works department
for plumbing and sanitation codes. You must fol
low their guides as you install the system. Follow
your local codes if they differ with guides in this
manual. Massachusetts plumbing code 248 CMR
shall be adhered to. Please consult your licensed
plumber.
This system shall only be used for arsenic reduc
tion on chlorinated water supplies containing de
tectable residual free chlorine at the system inlet.
Water systems using an inline chlorinator should
provide a one minute chlorine contact time before
the RO system.
Problems, Questions? Call 1
800-426-9345 Ken more Water Line
^ This system is acceptable for treatment of influ
ent concentrations of no more than 27 mg/L nitrate
and 3 mg/L nitrite in combination measured as N
and is certified for nitrate/nitrite reduction only for
water supplies with a pressure of 280 kPa (40 psig)
or greater. This system is supplied with a nitrate/nitrite test kit. Product water should be monitoredperiodically according to the instructions provided
with the test kit.
The reverse osmosis system works on water pres
sures of 40 psi (minimum) to 100 psi (maximum). If
your house water pressure is over the maximum,
install a pressure reducing valve in the water supply
pipe to the reverse osmosis system.
"Y Do not install the reverse osmosis system out
side, or in extreme hot or cold temperatures. Temper
ature of the water supply to the reverse osmosis sys
tem must be between 40 °F and 100°F. Do not install
on hot water.
Read the other limits (pH, hardness, etc.) in the
specifications and be sure your water supply con
forms. Also see "Water Supply" on page 4.
^ The reverse osmosis membrane contains a pre
servative for storage and shipment. Be sure to purge
as instructed on page 9 before using product water.
2
- TABLE OF CONTENTS —
Where To install the RO System
Tools and Materials Needed
6 Steps to Install ..................................................... 4
Your Reverse Osmosis (RO) Drinking Water System
is a water treatment unit. It uses household water
pressure to reverse a natural physical process called
osmosis. Water, under pressure, is forced through a
semi-permeable membrane where minerals and im
purities are filtered out. Clean drinking water goes to
the faucet or storage, while minerals and impurities
are sent to the drain with RO waste water. The miner
als and impurities are measured in water as total dissolved solids (TDS).
The system includes replaceable pre and postfilter
sediment-carbon cartridges. The prefilter removes
sand, silt, dirt, rust particles, other sediments, and
chlorine from the water supply before it can enter the
Repair Parts ............................................................. 18
RO membrane. The postfilter removes any tastes
and/or odors that may remain in the water, after
passing through the RO membrane, and just before
going to the RO faucet. To prevent water waste, an
automatic shutoff valve closes when the RO faucet is
closed and the storage tank is full.
Your reverse osmosis system gives you a continuous
supply of sparkling clear, delicious water for drink
ing, cooking and other uses. Foods will look and
taste better too. Fiaving high quality RO product wa
ter at your fingertips eliminates the need to buy
bottled water. The storage tank holds over 2 gallons
of RO product water for your needs.
...................................
................................
10
17
BEFORE YOU BEGIN TO INSTALL THE RO SYSTEM
FOR OPTIMUM PERFORMANCE YOUR KENMORE REVERSE OSMOSIS SYSTEM SHOULD BE
INSTALLED ON
CAUTION: A refrigerator icemaker may not operate
properly when connected to a reverse osmosis sys
tem that has been installed on a water system that op
erates outside of the specified pressures listed on
page 16.
Check Your Water Supply: The cold water supply to
the RO system must be within certain quality limits.
See the specification table on page 16. If supply water
is not within limits, the RO system can not make
product water as it should and reduced RO mem
brane life will result.
Trained sales people at Sears can perform a free water
analysis. This basic test can help determine if any
additional water treatment is required before the RO
system.
CAUTION: Chlorine in the water will destroy the
RO membrane. Most cities add chlorine to the water
supply to kill bacteria. The prefilter removes chlorine
up to the limits shown in the specifications before it
enters the RO membrane. It is important to replace
SOFTENED WATER.
the prefilter cartridge at least every 6 months. See
the RO care guide on page 13.
Check Parts Included: Unpack the carton and re
move the RO system. In addition to the assembled
RO and the storage tank, the system includes the
parts illustrated below, a separate length of tubing,
and this manual.
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
_ i"Q installtherosystem “
The RO assembly and storage tank is designed for
installation under the sink, usually in the kitchen or
bathroom. The RO assembly mounts on a wall sur
face, or can lay on the cabinet floor next to the storage
tank. Hanger washers and wood screws are included
for cabinet wall mounting. The RO product water
faucet installs on the sink, or on the countertop next
to the sink (page 6).
Note: Tubing lengths allow for the removal of the as
sembly from the hanger washers for servicing. If tub
ing lengths are shortened for neater appearance, it
may be necessary to keep the assembly on the hanger
washers for service.
You can also locate the RO assembly and storage tank
in any remote location from the faucet, observing
safety guides on page 2. You do need a nearby water
source and drain point (see page 17).
Water Supply: To provide supply water to the RO
system inlet use the included feed supply fitting or
install pipe fittings for tubing connection, as typical
ly shown on page 5.
Drain Point: A suitable drain point is needed for re
ject water from the RO membrane. A floor drain,
laundry tub, standpipe, sump, etc., is preferred, as
shown in the remote locations drawing, page 17. A
sink p-trap drain adaptor is included to install where
codes permit, as an optional drain point (page 6).
- TOOLS AND MATERIALS NEEDED -
^ adjustable wrench, standard pliers, and larger ^ electric drill and bits, if hole is needed for the RO
adjustable jaw pliers or pipe wrench to fit sink drain faucet, page 6.
^ slotted and Phillips head screwdrivers
ing Connections
STEP 6: - Sanitizing, Pressure Testing, Purging
- STEP 1: INSTALL COLD WATER SUPPLY FITTING -
Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The
fitting must provide a leak- tight connection to the RO 1 / 4" tubing (see Figure 8, page 8). A typical connection
using the included water supply fitting is shown in Figure 3A below. An optional connection, using standard
plumbing fittings (not included), is shown in Figure 3B.
Note: Codes in the state of Massachusetts require installation by a licensed plumber, and do not permit the use of a saddle
valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
A. WATER SUPPLY FITTING B. OPTIONAL PIPE FITTINGS (compression type
1. Close the house main water shutoff valve and open shown)
faucets to drain water from the sink cold water pipe. Note: Be sure to turn off the water supply and open
„ r> , ,1 , , ,1 u , r ,, a low faucet to drain the pipe.
2. Remove nut that connects the cold water faucet to ^ ^
cold water plumbing Complying with plumbing codes, install a fitting on
_ , „ , , the kitchen cold water pipe to adapt 1 /4" OD tubing.
3. Use pipe lomt compound or Teflon tape on cold water a . ■ i i ■ r- -»n Vr
. ^ , 1^ , r , A typical connection is shown m Figure 3d. it
faucet stud threads and on the male threads of the water , i j j r-,, • j i , ■ ■ ■ ,
, , , , , - threaded fittings are used, be sure to use pipe loint
supply fittme that connect to the cold water pipe. i Id ^- j ,i j
rf ^ f f compound or Teflon tape on outside threads.
4. Thread water supply fitting onto pipe and reconnect
nut to bottom of fitting.
A. WATER SUPPLY CONNECTION
(using Included water supply fitting)
water supply fitting
1/4” green tubing to
RO inlet (see step 2, on
page 8)
B. WATER SUPPLY TYPICAL CONNECTION
(using compression fitting)
- parts not included -
Figure 3
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
- STEP 2: INSTALL DRAIN ADAPTER -
■ Note: Running the drain tubing directly to a floor
drain, sump, standpipe, laundry tub, etc., as shown
on page 17, is preferred. However, if that is not pos
sible or practical, the included drain adapter installs
in the sink drain pipe, always above or ahead of the
p-trap. Figure 4. Be sure to comply with your localplumbing codes. Other drain pipe fittings, in addi
tion to the adapter, may be needed.
■ The drain adapter fits 1-1/2" sink drain pipe.
■ The adapter installs directly onto the sink tailpiece
as typically shown in Figure 4 and Figure 5.
■ Locate so drain tubing from the faucet makes a
straight run to the adapter, without dips, loops, low
spots or kinks.
Note: Consult a plumber if you are not familiar with
plumbing procedures.
1. Use a ferrule and nut to assemble the drain tubing
connector to the drain adapter (Figure 5). Turn the
connector to about 45° from the 12:00 position, as
shown (to 10:00 or 2:00 position as needed). Tighten
the nut securely.
2. Carefully disassemble the sink drain pipe and
clean the tailpiece to assure a leak-tight fit.
3. Install the drain adapter onto the sink tailpiece,
using a ferrule and nut. Snug the nut, but do not
tighten.
Note: If needed, to make fit, you can cut to shorten the
unthreaded end of the adapter. Do not cut too short
so the adapter will make a leak-tight seal with the
connecting fitting.
4. Assemble the p-trap to the drain adapter, and oth
er drain pipe fittings as required (check codes) to
complete the drain run.
5. Tighten all connections, but do not overtighten and
break plastic fittings.
STEP 3: INSTALL FAUCET
A, PREPARE MOUNTING HOLE
1. Select one of the following places for the faucet. Be
sure it will fit flat against the surface, and there is
space underneath for tubing (see Figure 8, page 8).
^ Use an existing sink top hole for a spray hose or
other faucet. A 1-1/4" diameter hole is needed.
^ Drill a new hole in the countertop next to the sink.
^ Drill a new hole in the sink top.
CAUTION: Drilling holes into countertops made of
stone or solid surface materials such as granite,
marble, Corian™ or other plastic resin products or
sinks made of porcelain and stainless steel should
only be performed by a fabricator installer who is cer
tified for fabricating such materials. Drilling of these
type surfaces by any other means may cause perma
nent, irreparable damage to the countertop surface.
2. If drilling is needed, make the 1-1/4" diameter
hole.
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.