OWNER'S
MANUAL
MODEL NO.
UltraFilter 150
625.385700
UltraFilter 350
625.385720
Caution:
Read and Follow
All Safety Rules and
Operating Instructions
Before First Use of
This Product.
If you have questions when
installing, operating or
maintaining your reverse
osmosis system, call this
toll-free number...
1-800-426-9345
(M-F, 7am-8pm, CST)
For repair or replacement
parts, call this toll-free num-
ber...
1-800-366-7278
See back cover for other
Sears service numbers.
www.KenmoreWater.com
Reverse Osmosis
Drinking Water System
_i,Warranty
_i, How To Install
_i, How It Works
_i, Care Of
_i, Repair Parts
System tested and certified by NSF International
to NSF!ANSl Standard 58 for the reduction of the
claims specified on the performance data sheet.
SAVE THIS MANUAL
PRINTEDtNU.S.A. Part No. 7266568 (Rev. H 8/4/05)
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U. S. A.
- WARRANTY-
F iiiiiiiii iiiiiiiiiiii iiiiiiii _
I I
i (except filter cartridges and R. O. membrane) i
i For one year from the date of purchase, when the Reverse Osmosis Drinking Water System is installed I
and maintained in accordance with our instructions, Sears will repair, free of charge, defects in material
i and workmanship, except filter cartridges and the R. O. membrane. I
I I
I TO OBTAIN WARRANTY SERVICE, SIMPLY CONTACT THE NEAREST SEARS SERVICE CENTER I
THROUGHOUT THE UNITED STATES. This warranty applies only while this product is in use in the
I United States. o
I I
I Thiswarrantygivesy_uspecific_egalrights_andy_umayhave_therrightswhichvaryfr_mstatet_state. I
! I
I Sears, Roebuck and Co., D/817 WA, Hoffman Estates, IL 60179 !
i I il iilll il Ill I il iilll il liliil i J
FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM
SEARS INSTALLATION POLICY SEARS INSTALLATION WARRANTY
All installation labor arranged by Sears shall be per-
formed in a neat, workmanlike manner in accor-
dance with generally accepted trade practices. Fur-
ther, all installations shall comply with all local laws,
codes, regulations, and ordinances. Customer shall
also be protected during installation by insurance re-
lating to Property Damage, Workman's Compensa-
tion and Public Liability.
In addition to any warranty extended to you on the
Sears merchandise involved, which warranty be-
comes effective the date the merchandise is installed,
should the workmanship of any Sears arranged
installation prove faulty within one year, Sears will,
upon notice from you, cause such faults to be cor-
rected at no additional cost to you.
I
I
- SAFETY GUIDES -
• Read all steps and guides carefully before instal-
ling and using your reverse osmosis system. Follow
all steps exactly to correctly install. Reading this
manual will also help you to get all the benefits from
the reverse osmosis system.
• Do not attempt to use this product to make safe
drinking water from non-potable water sources. Do
not use the system on microbiologically unsafe wa-
ter, or water of unknown quality without adequate
disinfection before or after the system. This system
is certified for cyst reduction and may be used on
disinfected water that may contain filterable cysts.
• Check with your local public works department
for plumbing and sanitation codes. You must fol-
low their guides as you install the system. Follow
your local codes if they differ with guides in this
manual. Massachusetts plumbing code 248 CMR
shall be adhered to. Please consult your licensed
plumber.
• This system shall only be used for arsenic reduc-
tion on chlorinated water supplies containing de-
tectable residual free chlorine at the system inlet.
Water systems using an inline chlorinator should
provide a one minute chlorine contact time before
the RO system.
• This system is acceptable for treatment of influ-
ent concentrations of no more than 27 mg/L nitrate
and 3 mg/L nitrite in combination measured as N
and is certified for nitrate/nitrite reduction only for
water supplies with a pressure of 280 kPa (40 psig)
or greater. This system is supplied with a nitrate/ni-
trite test kit. Product water should be monitored pe-
riodically according to the instructions provided
with the test kit.
• The reverse osmosis system works on water pres-
sures of 40 psi (minimum) to 100 psi (maximum). If
your house water pressure is over the maximum,
install a pressure reducing valve in the water supply
pipe to the reverse osmosis system.
• Do not install the reverse osmosis system out-
side, or in extreme hot or cold temperatures. Temper-
ature of the water supply to the reverse osmosis sys-
tem must be between 40°F and 100°F. Do not install
on hot water.
• Read the other limits (pH, hardness, etc.) in the
specifications and be sure your water supply con-
forms. Also see "Water Supply" on page 4.
• The reverse osmosis membrane contains a pre-
servative for storage and shipment. Be sure to purge
as instructed on page 11 before using product water.
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
- TABLE OF CONTENTS -
Where To Install the RO System ............ 4
Tools and Materials Needed ............... 4
6 Steps to Install ......................... 4
Install Cold Water Supply Fitting ......... 5
Install Drain Adapter ................... 6
Install Faucet ........................... 6
Install RO Assembly .................... 9
Install Storage Tank, Make Tubing
Connections ........................... 10
Sanitizing, Pressure Test, Purging ........ 11
How the RO System Works ............... 12
Care of Your RO System .................. 13
Dimensions, Specifications ................ 18
Remote Installation Locations ............. 19
Repair Parts ............................. 20
- WHAT YOUR REVERSE OSMOSIS SYSTEM WILL DO -
Your Reverse Osmosis (RO) Drinking Water System
is a water treatment unit. It uses household water
pressure to reverse a natural physical process called
osmosis. Water, under pressure, is forced through a
semi-permeable membrane where minerals and im-
purities are filtered out. Clean drinking water goes to
the faucet or storage, while minerals and impurities
are sent to the drain with RO waste water. The miner-
als and impurities are measured in water as total dis-
solved solids (TDS).
The system includes replaceable pre and postfilter
sediment-carbon cartridges. The prefilter removes
sand, silt, dirt, rust particles, other sediments, and
chlorine from the water supply before it can enter the
RO membrane. The postfilter removes any tastes
and/or odors that may remain in the water, after
passing through the RO membrane, and just before
going to the RO faucet. To prevent water waste, an
automatic shutoff valve closes when the RO faucet is
closed and the storage tank is full.
Your reverse osmosis system gives you a continuous
supply of sparkling clear, delicious water for drink-
ing, cooking and other uses. Foods will look and
taste better too. Having high quality RO product wa-
ter at your fingertips eliminates the need to buy
bottled water. The storage tank holds over 2 gallons
of RO product water for your needs.
- BEFORE YOU BEGIN TO INSTALL THE RO SYSTEM -
FOR OPTIMUM PERFORMANCE YOUR KEN-
MORE REVERSE OSMOSIS SYSTEM SHOULD BE
INSTALLED ON SOFTENED WATER.
CAUTION: A refrigerator icemaker may not operate
properly when connected to a reverse osmosis sys-
tem that has been installed on a water system that op-
erates outside of the specified pressures listed on
page 18.
Check Your Water Supply: The cold water supply to
the RO system must be within certain quality limits.
See the specification table on page 18. If supply water
is not within limits, the RO system can not make
product water as it should and reduced RO mem-
brane life will result.
Trained sales people at Sears can perform a free water
analysis. This basic test can help determine if any
additional water treatment is required before the RO
system.
CAUTION: Chlorine in the water will destroy the
RO membrane. Most cities add chlorine to the water
supply to kill bacteria. The prefilter removes chlorine
up to the limits shown in the specifications before it
enters the RO membrane. It is important to replace
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
the prefilter cartridge at least every 6 months. See
the RO care guide on page 15.
Check Parts Included: Unpack the carton and re-
move the RO system. In addition to the assembled
RO and the storage tank, the system includes the
parts illustrated below, a separate length of tubing,
and this manual.
TEFLON
TAPE
HANGER WASHERS
& SCREWS
TUBING
ADAPTER
2
ULTRAFILTER 350
Figure 1
3
DRAIN
ADAPTER
WATER SUPPLY
FITTING
ULTRAFtLTER 150
RO PRODUCT
WATER FAUCET
- WHERE TO INSTALL THE RO SYSTEM -
The RO assembly and storage tank is designed for
installation under the sink, usually in the kitchen or
bathroom. The RO assembly mounts on a wall sur-
face, or can lay on the cabinet floor next to the storage
tank. Hanger washers and wood screws are included
for cabinet wall mounting. The RO product water
faucet installs on the sink, or on the countertop next
to the sink (page 6).
Note: Tubing lengths allow for the removal of the as-
sembly from the hanger washers for servicing. If tub-
ing lengths are shortened for neater appearance, it
may be necessary to keep the assembly on the hanger
washers for service.
You can also locate the R© assembly and storage tank
RO product RO product
water faucet _ o_ water faucet
UItraFilter 350 UItraFilter 150
/ x
in any remote location from the faucet, observing
safety guides on page 2. You do need a nearby water
source and drain point (see page 19).
Water Supply: To provide supply water to the RO
system inlet use the included feed supply fitting or
install pipe fittings for tubing connection, as typical-
ly shown on page 5.
Drain Point: A suitable drain point is needed for re-
ject water from the RO membrane. A floor drain,
laundry tub, standpipe, sump, etc., is preferred, as
shown in the remote locations drawing, page 19. A
sink p-trap drain adaptor is included to install where
codes permit, as an optional drain point (page 6).
HOT :COLD
sink drain
p-trap
Figure 2
- TOOLS AND MATERIALS NEEDED -
• adjustable wrench, standard pliers, and larger
adjustable jaw pliers or pipe wrench to fit sink drain
slotted and Phillips head screwdrivers
plumbers putty
- 6 STEPS TO INSTALL -
STEP 1: - Install Cold Water Supply fittings
STEP 2: - Install Drain Adapter
STEP 3: - Install Faucet
adapter
RO Assembly
• electric drill and bits, if hole is needed for the RO
faucet, page 6.
STEP 4: - Install RO Assembly
STEP 5: - Install Storage Tank, Make Remaining Tub-
ing Connections
STEP 6: - Sanitizing, Pressure Testing, Purging
4
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
- STEP 1: INSTALL COLD WATER SUPPLY FITTING -
Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The
fitting must provide a leak-tight connection to the RO 1/4" tubing (see Figure 10, page 10). A typical connec-
tion using the included water supply fitting is shown in Figure 3A below. An optional connection, using stan-
dard plumbing fittings (not included), is shown in Figure 3B.
Note: Codes in the state of Massachusetts _vquire installation by a licensed plumbe_, and do not permit the use of a saddle
valve. For installation, use plumbing code 248-CMR of the Commonwealth of Massachusetts.
A. WATER SUPPLY FITTING
1. Close the house main water shutoff valve and open
faucets to drain water from the sink cold water pipe.
2. Remove nut that connects the cold water faucet to
cold water plumbing.
3. Use pipe joint compound or Teflon tape on cold water
faucet stud threads and on the mate threads of the water
supply fitting that connect to the cold water pipe.
B. OPTIONAL PIPE FITTINGS (compression type
shown)
Note: Be sure to turn off the water supply and open
a low faucet to drain the pipe.
Complying with plumbing codes, install a fitting on
the kitchen cold water pipe to adapt 1/4" ©D tubing.
A typical connection is shown in Figure 3B. If
threaded fittings are used, be sure to use pipe joint
compound or Teflon tape on outside threads.
4. Thread water supply fitting onto pipe and reconnect
nut to bottom of fitting.
cold water
faucet stud
cold
pipe i ,
waterI I
A. WATER SUPPLY CONNECTION
(using included water supply fitting)
water supply fitting
1/4" green tubing to
RO inlet (see step 2, on
page 8)
B. WATER SUPPLY TYPICAL CONNECTION
(using compression fitting)
- parts not included -
I
1/4" compression
fitting
insert
Figure 3
ferrule
cold _ 1/4" tubing to
&
cold water
shutoff
water RO inlet (see step
pipe 2, on page 8)
5
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
- STEP 2: INSTALL DRAIN ADAPTER -
• Note: Running the drain tubing directly to a floor
drain, sump, standpipe, laundry tub, etc., as shown
on page 19, is preferred. However, if that is not pos-
sible or practical, the included drain adapter installs
in the sink drain pipe, always above or ahead of the
p-trap, Figure 4. Be sure to comply with your local
plumbing codes. Other drain pipe fittings, in addi-
tion to the adapter, may be needed.
• The drain adapter fits 1-1/2" sink drain pipe.
• The adapter installs directly onto the sink tailpiece
as typically shown in Figure 4 and Figure 5.
• Locate so drain tubing from the faucet makes a
straight run to the adapter, without dips, loops, low
spots or kinks.
Note: Consult a plumber if you are not familiar with
plumbing procedures.
1. Use a ferrule and nut to assemble the drain tubing
connector to the drain adapter (Figure 5). Turn the
connector to about 45 ° from the 12:00 position, as
shown (to 10:00 or 2:00 position as needed). Tighten
the nut securely.
P-trap
Figure 4
2. Carefully disassemble the sink drain pipe and
clean the tailpiece to assure a leak-tight fit.
3. Install the drain adapter onto the sink tailpiece,
using a ferrule and nut. Snug the nut, but do not
tighten.
Note: If needed, to make fit, you can cut to shorten the
unthreaded end of the adapter. Do not cut too short
so the adapter will make a leak-tight seal with the
connecting fitting.
4. Assemble the p- trap to the drain adapter, and oth-
er drain pipe fittings as required (check codes) to
complete the drain run.
5. Tighten all connections, but do not overtighten and
break plastic fittings.
- STEP 3: INSTALL FAUCET -
A. PREPARE MOUNTING HOLE
1. Select one of the following places for the faucet. Be
sure it will fit flat against the surface, and there is
space underneath for tubing (see Figure 10, page 10).
0 Use an existing sink top hole for a spray hose or
other faucet. A 1-1/4" diameter hole is needed.
J Drill a new hole in the countertop next to the sink.
t Drill a new hole in the sink top.
CAUTION: Drilling holes into countertops made of
stone or solid surface materials such as granite,
ferrule 0
I_yrain adapter black
cut, if _ t X. i
needed 10:00 ./,_ _2:00
Figure 5
marble, Corian:" or other plastic resin products
should only be performed by a fabricator installer
who is certified for fabricating such materials. Dril-
ling of these type surfaces by any other means may
cause permanent, irreparable damage to the counter-
top surface.
2. If drilling is needed, make the 1-1/4" diameter
hole.
3. Place plumbers putty around the drilled hole
(Figure 6 and Figure 7) to prevent water leakage
around the base of the faucet.
J(__u 45_ 4_.._
dcraoinnnteUbionrg _
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
- STEP 3: INSTALL FAUCET (cont.)-
B. ASSEMBLE FAUCET
ULTRAFILTER 150
UltraFilter 150
1. Loosely assemble the base, spacer, washer and
plastic nut onto the faucet stud.
2. Route the 1/4" red tubing through the sink or
countertop hole and connect to 1/4" barb on faucet.
3. Route the 3/8" black tubing through sink or the
countertop hole and connect to 3/8" barb on faucet.
4. Attach the 3/8" blue tubing to the faucet stud us-
ing the tubing adaptor.
5. Lower faucet into place on the countertop, on the
underside of the countertop or sink slide the slotted
washer into place and tighten plastic nut. Tighten
the nut so the faucet cannot move, but do not over-
tighten.
b__i_ bers
slotted washer _ (_
""
washer -......._(_
hex nut _ (_
faucet & spout
H hole in sink or
tubing adaptor
(connects to
1/4" red tubing
from RO drain
(connect to 1/4"
barb on faucet)
3/8" blue tubing
(connect to stud
on faucet)
Figure 6
/bottom of stud)
3/8" black tubing to
drain point (connect
to 3/8" barb on faucet)
/
7
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
- STEP 3: INSTALL FAUCET (cont.)-
B. ASSEMBLE FAUCET
ULTRAFILTER 350
1. Remove the nut from the faucet threads.
2. Remove the spacer from the threads. To do this,
place a finger on either side of the threads and gently
press thumb against the bottom of the faucet threads
(where the quick connect is). The spacer should slide
past the stop.
3. Slide the two attached tubes through the sink or
countertop hole, aligning gasket under faucet base.
4. On the underside of the sink or countertop, slide
the spacer back onto the faucet threads. The spacer
should align with the tubing in the back. Tighten the
nut so the faucet cannot move, but do not overtigh-
ten.
UltraFilter 350
faucet & spout
bezel
gasket
5. Connect tubing.
a. Connect the 3/8" blue tubing from the RO system
to the quick connect at the bottom of the faucet
threads.
Note: See page 16 for tubing connection instructions.
b. Connect the 3/8" tubing from the faucet to the
drain point (drain adaptor).
c. Connect the 1/4" red tubing (supplied with RO)
to the 1/4" tubing attached to the faucet using the
1/ 4" x 1 / 4" quick connector.
6. Remove the spout from the top of the faucet by
pulling it straight upward.
7. Remove the faucet knob by pinching the two lock-
ing tabs inward and then pulling upward on the
knob while the tabs are pinched inward. See Figure 8.
8. Push the coin cell battery into the battery holder be-
hind the circuit board. NOTE: the + side of the bat-
tery goes against the gold metal bracket.
9. Replace the knob by centering it over the faucet
and aligning the channel on the inside of the knob
with the valve lever.
hole in
sink or
coun
spacer J
TUBING
RO SYSTEM
3/8"
tubing
plumbers
putty
1/4" tubing to
1/4" red tubing
on RO
3/8" tubing
to drain point
nut
1/4" red
tubing
10. Lower the knob making sure the valve lever
slides into the channel then make sure the top hole
in the knob is centered over the locking tabs.
11. Push the spout back into the top of the faucet so
that it is fully seated and push the bezel down until
fully seated. You may have to rotate the bezel until it
is in position to be fully seated.
Problems, Questions? Call 1-800-426-9345 Kenmore Water Line
Figure 7
8