Kenmore 625.38356 User Manual

OWNER'S MANUAL

Water Softeners

With Deluxe Valve
MODEL NOS.
IntelliSoft 350 Series 625.383560 IntelliSoft 350 Series 625.393560
Caution: Read and follow all safety rules and operating instructions before first use of this product.
Questions ? Visit www.KenmoreWater.ram or call toll free 1-800^26-9345 (M - F, 7AM - 8 PM CST)
Repair or Parts ? Call toll free 1-800-469-4663
See back cover for other Sears service numbers.
SAVE THIS MANUAL
Use the plastic bag and tie provided, to hang manuals nearby the softener for future reference.
Sears, Roebuck and Co., 3333 Beverly Road, Hoffman Estates, IL 60179 U.S.A.
PRINTED IN U.S.A.
www.KenmoreWater.com
Warranty
Installation
Start Up / Setting Timer
How It Works Care Of Specifications
Repair Parts
Systems Tested and Certified by NSF International against
NSF/ANSI Standard 44 for softener performance.
Part No. 7282598 (Rev. J 11/12/08)
WARRANTY ON WATER SOFTENER

ONE YEAR LIMITED WARRANTY ON WATER SOFTENER

When installed, operated and maintained according to all instructions supplied with the product, if this
Kenmore appliance fails due to a defect in material and workmanship within one year from the date of pur
chase, call 1-800-4-MY-HOME® to arrange for free repair.

TEN YEAR LIMITED WARRANTY AGAINST LEAKS

When installed, operated and maintained according to all instructions supplied with the product, if the water
softener tank or salt storage drum develops a leak within ten years from the date of purchase, call 1-800-4­MY-HOME® to arrange for free tank or drum replacement. After the first year you must pay an initial trip charge.
All warranty coverage does not include water softener resin, which is an expendable item.
If this water softener is ever used for other than private family purposes, all warranty coverage applies for only 90 days from the date of purchase.

This warranty covers only defects in material and workmanship. Sears will NOT pay for:

1. A service technician to instruct the user in correct product installation, operation or maintenance.
2. A service technician to clean or maintain this product.
3. Damage to or failure of this product if it is not installed, operated or maintained according to the all instruc tions supplied with the product.
4. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intend ed purpose.
5. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
6. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.

Disclaimer of implied warranties; limitation of remedies

Customer’s sole and exclusive remedy under this limited warranty shall be product repair as provided herein. Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential dam ages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential dam ages, or limitation on the duration of implied warranties of merchantability or fitness, so these exclusions or
limitations may not apply to you. This warranty applies only while this appliance is used in the United States or Canada. This warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.

Sears, Roebuck and Co., Hoffman Estates, IL 60179 Sears Canada Inc., Toronto, Ontario, Canada MSB 2B8

Questions? Call The Kenmore Water Line 1-800-426-9345

TABLE OF CONTENTS

Safety Guides..................................................................................................................................................4
Unpack and Check Shipment .........................................................................................................................5
Plan Your Installation: Tools Needed, Materials Needed..........................................................................6-10
Install InIet/Outlet Adapters or Bypass Valves, Three Way Valves.........................................................11-12
Install Softener and Connect Pipes...............................................................................................................13
Connect Valve and Salt Tank Drains............................................................................................................ 14
Leak Test.......................................................................................................................................................15
Electrical Requirements.................................................................................................................................16
Install Covers and Restart Water Heater...................................................................................................... 17
Program the Timer................................................................................................................................... 17-18
Sanitize the Water Softener...........................................................................................................................19
Add Salt to Storage Tank...............................................................................................................................20
Install Checklist.............................................................................................................................................21
Faceplate Timer Features........................................................................................................................22-25
How Your Water Softener Works.............................................................................................................26-28
Care of Your Water Softener....................................................................................................................29-32
Specifications...........................................................................................................................................33-34
Service Tech Information.........................................................................................................................35-41
Exploded Views and Parts Lists...............................................................................................................42-47
Sears Tech Support..........................................................................................................................Back Cover
FACTS AND FIGURES TO KEEP
Fill in the blanks below and keep this book in a safe place so
you always have these facts.
Water Softener Model No.* Serial Number______________________________________________ Date Installed Water Hardness Iron Content
pH
__________
Water Pressure _ Water Flow Rate
The model number is on the rating decal, located on the rim, under the salt hole cover.
___
___________________________________
Grains Per Gallon
Parts Per Million
Taste and/or Odor
Pounds/Square Inch
Gallons Per Minute

Questions?

Call the Kenmore Water Line at 1-800-426-9345
or visit KenmoreWater.com
For repair or replacement parts, call toll-free 1-800-366-7278
See back cover for other Sears service numbers.
Questions? Call The Kenmore Water Line 1-800-426-9345

Safety Guides

^ Read all steps, guides and rules carefully before installing and using your new water softener.
Follow all steps exactly to correctly install. Failure to follow them could cause personal injury or property damage. Reading this book will also help you to get all of the benefits from your
water softener.
^ Your Kenmore Water Softener will remove hardness minerals from water. This is measured in
grains per gallon (gpg). It will also remove some clear water iron*. This is measured in parts per million(ppm). See the specifications page for the maximum limits of hardness and iron removal.
^ A water softener will not improve other water problems such as acidity, tastes and odors, or
iron other than clear water iron. It will not purify contaminated water, or make unsafe water safe to drink.
^ Check with your local public works department for plumbing, electric and sanitation codes.
You must follow their guides as you install your softener. Use only LEAD FREE SOLDER AND FLUX, as required by federal and state codes, when installing soldered copper plumb ing.
^ Protect the softener and piping from freezing. Damage from freezing voids the softener war
ranty. See how to protect from freezing on page 31.
CAUTION: Please read and comply with the following guides to prevent damage to the sof tener or other property, personal injury, or possible fatal shock.
^ This softener works on 24 volts only. Be sure to use only the transformer included.
Plug it into a nominal 120V, 60 cycle household outlet that is grounded and properly protected by an overcurrent device such as a circuit breaker or fuse. If transformer is replaced, use only the authorized service Class II, 24 volt, 10 VA transformer.
^ Unplug the transformer right away if the power cable should become damaged or frayed.
Make repairs, or replace the transformer, before plugging back into the power outlet.
^ Always unplug the softener from electrical power before removing outer valve covers. ^ This system is not intended to be used for treating water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system.
* The capacity to reduce clear water iron is substantiated by WQA test data.
♦X
European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic Equipment (WEEE)
requirements. This directive or similar laws are in place nationally and can vary from region to region. Please refer to your state and local laws for proper disposal of this equipment.

Unpack and Check Your Carton

INSPECT SHIPMENT

Your water softener is shipped complete in one carton. Use care when handling the softener. DO NOT turn upside down. DO NOT drop, or set on sharp objects that could make a hole in the bottom. The water softener is heavy, do not try to lift it or move more than is necessary.
Remove all items from your shipping carton. Check all items against the packing list below. Note any items lost or damaged in shipment.
Note any damage to the shipping carton. Refer to the exploded view and parts list in the back of the manual for the part names and numbers of missing or damaged items.
Contact the store where purchased if problems exist.
Packing List
Salt Hole

PARTS DESCRIPTIONS

Nozzle
Assembly
Valve
Assembly
owner’s manual
n
SMALL PARTS
Installation
Adaptors (2)
Clips (4)
n
Bypass Valve
J
Drain Tubing
Tube Clamp
Ground Clamp Kit
Questions? Call The Kenmore Water Line 1-800-426-9345
Grommet
Tube Adaptor
Tube Clamp
FIG. 1
Plan Your Installation
PLAN YOUR INSTALLATION
It is recommended to read through the entire manual before beginning your installation. Follow all steps exactly. Reading this manual will also help you get all the benefits from your system.
TOOLS NEEDED:
• Safety glasses
• Flathead screw driver
• Phillips screw driver
• Adjustable slip joint pliers
• Tape measure or ruler
Safety Glasses Flathead Screwdriver Phillips Screwdriver Adjustable Slip Joint Pliers Tape Measure or Ruler
ADDITIONAL TOOLS NEEDED FOR THE FOLLOWING INSTALLATIONS:
SOLDERED COPPER THREADED PIPE CPVC OR PVC PLASTIC
• Tubing Cutter • Flacksaw or Pipe Cutter • Flacksaw
• Propane Torch • Pipe Wrenches • Adjustable Wrench
• Solid Core LEADFREE Solder • Pipe Threading Tool • Primer and Solvent Cement
• Paste Flux • Pipe Joint Compound approved approved for use on potable water-
• Emery Cloth
• or Sandpaper
for use on potable water
THE PROPER ORDER TO INSTALL WATER TREATING EQUIPMENT
(Shows sequence of equipment only. Seldom, if ever, would all items be needed.)
Kitchen or Bathroom
Sediment or Taste & Odor Cartridge Filter
Cold, soft water
Hot, soft water
a
Water
Softener
Always place an Iron Filter UPSTREAM of the water softener.
Always place a Neutralizer UPSTREAM of an Iron Filter, etc., as shown.
• Place a Taste & Odor Filter UPSTREAM of a water softener on a chlorinated water supply
and DOWNSTREAM of a water softener on a non-chlorinated water supply.
V Cold Faucet
l I I I I I 1 r
*Taste &
Odor Filter
Iron
Filter
Hard Water to
Outside Faucets
Q Q Q Q
Neutralizer Clarifying
Filter
Sediment
Cartridge Filter
(Optional Location)
Well Water Supply
Pressure or Dispensing
Captive Air System
Solution
FIG. 2
Questions? Call The Kenmore Water Line 1-800-426-9345
outside faucet
Plan Your Installation
WHERE TO INSTALL THE WATER SOFTENER
Review the following points before you choose a place to put your softener.
1. Place as close as possible but always after, the pressure tank (well water) or water meter (city
water). See Fig. 3.
2. Place as close as possible to a water drain such as a floor drain, laundry tub, sump or standpipe. See
Fig. 3.
3. Connect to the house main water pipe BEFORE TFIE WATER FIEATER. See Fig. 3. Temperature of
water going through the softener must not be
more than 120°F (49°C). Plot water will damage
inner softener parts. To reduce the risk of hot water
backup, piping between the softener and water
heater should be as long of a run as possible.
4. Keep outside faucets on hard water to save soft water and salt. See Fig. 3.
5. Do not install in a place where the softener could freeze. Damage caused by freezing voids the war
ranty by Sears, Roebuck and Co.
6. Put the softener in a place where water damage is least likely to occur if it develops a leak. Sears or the manufacturer will not repair or pay for water damage.
7. A grounded, 120V electrical outlet is needed within 10 feet of the softener. See Fig. 3. This is to plug in the transformer. The softener has a 10 foot power cable. Be sure the outlet and transformer are in an inside place, to protect from wet weather. Use a continuously “live” outlet, which cannot be acci dentally switched off.
8. When installing in an outside location, you must take the steps necessary to assure the softener, installa tion plumbing, and wiring, are protected from the elements, contamination, vandalism, etc.
9. Keep the softener out of direct sunlight. The sun’s heat can melt plastic parts.
FIG. 3
Questions? Call The Kenmore Water Line 1-800-426-9345
Plan Your Installation
Suggested Slab Foundation Installation
outside
- hard
p-trap inside home, if possible. Otherwise, run to a dry well.
DRAW IN YOUR PIPES AND FITTINGS
Draw the plans for your “IN" and “OUT” piping here. Include all pipe, fittings and accessories you will use.
Make a list of all materials you will need and buy them before you begin to install the water softener.
120V-60Hz
Electrical
Outlet
FIG. 4
Your House Main Water Pipe
Left
Right
* In what direction does the water flow?
Be sure to plan “IN" and “OUT” piping so water flow is to the softener valve inlet. Plan a crossover If flow Is from left to right.
CROSS-OVER
Main Water Pipe
Valve Outlet Side
Valve Inlet
Questions? Call The Kenmore Water Line 1-800-426-9345
FIG. 5
Plan Your Installation
PIPE, FITTINGS, OTHER MATERIALS NEEDED
You must first decide how to run “in” and “out” pipes to the softener. Look at your house main water pipe at the point you will connect the softener. Is the pipe soldered copper, glued plastic, or threaded galvanized or brass? What is the pipe size? What kind of pipe and fittings is it easiest for you to work with, and what tools do you have?
Now look at the common plans for “in” and “out” piping on soldered copper. See Fig. 6. Use it as a guide to plan what materials you will need. Get all the materials you will need before you start.
Use Fig. 5 to make a plan drawing for your specific installation. “In” and “out” fittings included with the soften er are 1” NPT threaded adaptors. You should maintain the same, or larger, pipe size as the water supply pipe, up to the softener inlet and outlet. Use copper, brass, galvanized or PVC plastic pipe and fittings for the “in” and “out” pipes. Be sure to check local codes.
Note: If converting from galvanized to copper pipe use approved dielectric insulating connectors.
ALWAYS install the bypass valve (that is included with the unit) or a three valve bypass. See Fig. 9 to13. Bypass valves let you turn off water to the softener if needed for repairs, but still have water in the house pipes.
SOLDERED
1" NPT sweat
adaptor (2)*
OUT IN
Drain tubing (3/8” inside diameter), is needed for the valve and salt tank drains. See Fig. 16. If a rigid valve drain is needed to comply with plumbing codes, you can buy the parts needed (see Fig. 16) to change the soften er to a 1/2 inch minimum copper tubing drain.
FIG. 6
»NOTE:
For plumbing connection, buy 2 sweat adaptors and plumb directly to the inlet - outlet adaptors. Threads on the inlet - outlet adaptors are 1" NPT.
CAUTION: DO ALL SOLDERING BEFORE CONNECTING SWEAT ADAP TORS TO INLET-OUTLET ADAPTORS OR BYPASS VALVE.
Questions? Call The Kenmore Water Line 1-800-426-9345

Read Before Beginning Installation

BEFORE INSTALLING CHECKS & TESTS

Your water supply needs to be checked for chemical analysis, water pressure and water flow rate. To accom plish this, complete the following steps:
Check Water’s Chemical Analysis: Sears sells a com plete line of water treating equipment to correct various water problems. To be sure you have the proper type and size equipment. You must have your water tested. Your Sears store can give you a water test results for hardness, iron and acidity, and tell you what equipment you need. Simply take at least a 4 oz. sample of your water to Sears, and they will test it while you wait. If you need help to get your water tested, or if you have other questions about your water, ask at your Sears store.
NOTE: Add these readings to the Facts and Figure tabie on page 3.
Check Your Water Pressure: For your softener to work right, a water pressure of no lower than 20 pounds per square inch (psi) is needed in the house water pipes. The highest pressure allowed in the water pipes is 125 psi. If pressure is over 125 psi, buy and install a pres sure reducing valve in the water inlet pipe to the soften er.
NOTE: if water pressure during the day is 100 psi or more, pressure during the night may go over 125 psi.
Adding a pressure reducing vaive may reduce the
fiow.
NOTE: Add these readings to the Facts and Figure
tabie on page 3.
If you have a well water system, look at the pressure gauge to find the water pressure. Call your local water department if you have city water. They will tell you what the water pressure is where you live.
NOTE: Add these readings to the Facts and Figure
tabie on page 3.
Check your water flow rate: A water flow of at least 3 gallons per minute is needed. A lower flow will keep your softener from working as well as it should. Complete the following steps to make an easy check of your flow rate.
1. Fully open two cold water faucets close to the point water enters the house.
2. With both faucets open, fill a gallon container at one faucet while looking at a watch or clock to see how many seconds it takes.
3. Empty the container and go to the second faucet (be sure BOTFI faucets are still on). Fill the gallon container at the second faucet and see how many seconds it takes.
4. Turn off both faucets. Now add the number of seconds it took to fill the container at both faucets.
5. A total of 90 seconds, or less, means the system flow rate is good.
NOTE: Add these readings to the Facts and Figure
tabie on page 3.
NOTE: Codes in the state of Massachusetts require instaiiation by a iicensed piumber. For instaiiation, use piumbing code 248CMR of the Commonweaith of Massachusetts.
10
Questions? Call The Kenmore Water Line 1-800-426-9345

Install Single Bypass Valve

iMr Hr ■

ASSEMBLE INLET OUTLET ADAPTORS,

OR SINGLE BYPASS VALVE

Complete the following steps to assemble the adaptors or bypass valve.
1. Close the shutoff valve on the house main water pipe, near the water meter or pressure tank, to turn off the
water. See Fig. 7.
2. Shut off the gas or electric supply to the water heater. See Fig. 7.
3. Open the highest and lowest water faucets in your
house. This will let water drain from the pipes. Close
faucets after water has drained.
4. Remove the main cover. See Fig. 8.
Pull outward on two (2) tabs to release.
The salt hole cover remains attached to the main cover when removed. Set both covers aside so they will not get scratched or broken.
INSTALL SEARS BYPASS VALVE AND / OR THE INLET OUTLET THREADED ADAPTORS
NOTE: If you will not install the bypass valve because
you will have a three (3) valve bypass, skip steps 6 &
7, but do steps 5 and 8.
5. Visually check and remove any foreign materials from the valve inlet and outlet ports. See Fig. 9. Carefully
remove the two large plastic clips (you will use them). Check to be sure the turbine and turbine support are firmly in place. See Fig. 10.
Shutoff
Valve
Valve
Gas
\
V V
Water Meter
Electrical
Panel
FIG. 7
Salt Hole Cover
FIG. 8

BYPASS VALVE:

6. Put a light coating of silicone grease on the o-ring seals and slide onto the bypass valve.
7. Push the bypass valve into the softener valve as far as it will go. Snap the two large holding clips into place,
from the top down as shown. See Fig. 11.
CAUTION: Be sure the clips snap firmly into place so the bypass valve will not pull out. See Fig. 11.

INLET AND OUTLET THREADED ADAPTORS:

8. Put a light coating of silicone grease on the o-ring seals and slide into the threaded adaptors. Push the adaptors
into the valve inlet and outlet ports, or bypass valve ports, as far as they will go. Both adaptors are the same
and fit either port. Snap the two large holding clips
into place, as shown. See Fig. 11.
CAUTION: Be sure the clips snap firmly into place so the tubes will not pull out. See Fig. 11.
Questions? Call The Kenmore Water Line 1-800-426-9345
INSTALLING BYPASS VALVE, AND/OR
INLET AND OUTLET THREADED ADAPTORS
Clip (2)
Included with Softener
Included with Softener
FIG. 9
11

Install Single Bypass Valve

Before installing the bypass valve, or copper tube, be sure the turbine and support are firmly in place in the valve outlet port.
iMr Hr ■
Bypass Valve or Installation Adaptor

INSTALLING HOLDING CLIPS

Black Clip
Cross Section of Valve
Inlet or Outlet
\
Turbine Support
Sensor Port
/
\
]
\
Turbine
FIG. 10

Install 3-Valve Bypass

INSTALLING 3 VALVE BYPASS AND PIPES

Complete the following steps to install the three (3) valve bypass:
• Cut the house main water pipe where you will con
nect the softener.
• Loosely put together pipe, fittings, and the three
(3) valves.
• Place valve(s) within easy reach.
Clip Snaps into Place
Between Larger Diameter Rings

BYPASS VALVE TURNED DOWNWARD

0-Ring
Turn bypass valve upside down to connect to floor level plumbing.
FIG. 11
FIG. 12
When all pipe, fittings and valves make a good fit together, tighten all threaded joints (use pipe dope on outside threads), or solder all sweat joints.
Questions? Call The Kenmore Water Line 1-800-426-9345
12

Locate Water Softener and Connect Pipes

POSITION SOFTENER INTO PLACE

Complete the following steps to position the softener.
1. Grip under the ridge on the salt tank sidewall.
2. Carefully rock back and forth into position.
3. Move the softener into position.
4. Place on a level and smooth surface. If needed, put a
piece of 3/4” plywood, at least 17" x 20", under the tank. Then put spacers under the plywood to level the softener. See Fig. 14.
NOTE: Do not put shims or spacers directly under
the tank, without the plywood. The weight of the sof tener, when full of salt and water, may cause the tank to puncture or break at the shim or spacer.

MOVE SOFTENER INTO PLACE

Grip under ridge jr
to move softener.

CONNECT THE SOFTENER

Refer to your plan drawing. See Fig. 5. Measure, cut (thread if needed) and put all pipe and fit tings together up to the main water pipe, or to the bypass valve(s) you installed in the previous step.
CAUTION: Never solder fittings while connected to
nonmetallic parts. Wait until soldered pipe has cooled before connection. See Fig. 15.
CAUTION: Be careful when putting pipe fittings together. Do not cross thread, and do not overtight
en.
Plywood
TYPICAL SOLDERING
CONNECTIONS
Main Water Pipe
Solder NOTE: To be certain heat will not travel down the pipe and into the bypass valve (or Installation adaptors), wrap the bottom of the pipe and the bypass valve In a wet rag.
Shims
Hard Water
1. Cut pipe to correct length.
2. Solder (WHEN COOL, do Step 3).
Questions? Call The Kenmore Water Line 1-800-426-9345
3. Put threaded adaptor Into bypass valve port.
FIG. 15
13

Connect Valve and Salt Tank Drains

CONNECT THE VALVE DRAIN HOSE

Take a length of 3/8” inside diameter drain tubing and attach one end to the drain fitting. See Fig. 16. Use a tube clamp to hold it in place. Put the other end of the tubing over a floor drain, into a laundry tub, standpipe, or other suitable drain. Check your local codes.
Leave an air gap of about 1-1/ 2" between the end of the hose and the drain. This gap is needed so you don’t get a backflow of sewer water into the softener.
Do not put the end of the hose into the drain or con
nect without the air gap.
Place and support the hose so it does not kink or have sharp bends. Secure the hose end so water pressure does not cause the hose to “whip”. Tie or wire it in
place. Do not pinch the hose shut. The softener will
not work if this drain hose is pinched, plugged, closed or restricted in any way. Direct drain flow
down into drain from drain line as flow could possibly over shoot the drain cover.
Keep the hose lower than the drain fitting. In some
homes, to get to a drain you must raise the hose and
run it overhead. If you need an overhead drain, do not
raise the hose more than 8' above the floor. A copper drain tube is best to use.
COPPER DRAIN TUBE: Local plumbing codes may
require the use a copper valve drain tube. A copper
tube is also best to use for an overhead drain. Use a
copper drain tube if the softener is installed outside, or in the sunlight. Heat from the sun can soften, flatten and close up some kinds of tubes.
To adapt a copper drain tube to the softener, buy a
compression fitting (1/4" female pipe threads x 1/2"
0. D. tube) and tubing from your local hardware store.
CONNECT SALT TANK OVERFLOW TUBING
1. Locate the rubber grommet, tube adaptor and tube clamp (see Fig. 16) that are in the parts bag.
2. Push the grommet into the hole in the salt tank wall so half is inside and half is outside.
3. Push the bigger end of the tube adaptor into the grommet.
4. Push one end of a length of 3/ 8" I.D. tubing onto the tube adaptor, using the tube clamp to hold it in place.
5. Put the other end of the tubing over the floor drain.
IMPORTANT: Overflow water must run downward through the tubing. Do not raise the tubing higher than the grommet and tube adaptor. See Fig. 16.
IMPORTANT: Do not connect to the valve drain hose you installed in step 1. Both drains must have a separate hose or tube.
NOTE: Overflow drain tubing is available from Sears. See parts list in back of manual.
NOTE: Overflow drain tubing is avai^ able from Sears, Item No. 42-3433 (20 ft).
Overflow Drain Tubing
Clip
Cut Barbs from Drain
Fitting (Puil ciip and
remove fitting from vaive.
FLOOR DRAIN
1/4 NPT Threads
Barbs
>1
Comp F
1/2 in. O.D. Tube
(Not furnished)
To drain point other than floor drain.
■ Support tubing in place as needed.
1/2" Outside Diameter
Copper Tube
(Not furnished)

FIG. 16

14
Questions? Call The Kenmore Water Line 1-800-426-9345

Leak Test

LEAK TEST

To check for leaks, complete the following steps:
CAUTION: To avoid water or air pressure dam
age to softener inner parts, and to flush pipe chips or other residue from the water pipes, be sure to do the following steps exactly as instructed.
1. Fully open two cold, soft water faucets near the softener.
2. Look at the pictures In Fig. 18 and 19 to deter mine your kind of bypass valve(s). Place bypass
valve(s) In “bypass” position. On a single valve, slide the stem inward to bypass. On a three (3) valve system, close the inlet and outlet valves and open the bypass valve.
3. Fully open the house main water pipe shutoff
valve. Observe steady water flow from both open faucets.
4. Place bypass valve(s) in SERVICE EXACTLY as
follows: Keep soft water faucets open. a. Single Bypass Valve: Slowly, slide pull the valve stem outward toward service, pausing sev eral times to allow the softener to pressurize slow
ly­b. Three Valve Bypass: Fully close the bypass
valve and open the outlet valve. Slowly, open the
inlet valve, pausing several times to allow the sof
tener to pressurize slowly.
5. After about three minutes, open a hot water
faucet for about one minute, or until all air is expelled, then close.
6. Close both cold water faucets.
7. Check your plumbing work for leaks and fix right
away if any are found. Be sure to observe previ
ous caution notes.

HOUSE MAIN WATER

VALVE BYPASS

NOTE: If this procedure is performed on a new softener, water coming from the taps may initial ly be discolored. This normally occurs the first
time water runs through the resin bed. The dis colored water is not harmful, and the discol oration will not last more than a few minutes.
Questions? Call The Kenmore Water Line 1-800-426-9345
FOR SERVICE
Close bypass valve.
Open inlet & outlet
valves.
FOR BYPASS
Open bypass valve.
Close inlet & outlet
valves.
FIG. 19
15