Kenmore 625383500, 625384200, 625383001, 625383000 Installation Guide

Installation Instructions Instrucciones de Instalaci6n
Instructions d'installation
English / Espafiol / Fran_:ais
Models / Moclelos / ModUles
625.383000
625.383500
625.384200
625.75116
625.75126
625.75130
625.75230
625.75390
625.75490
specifications, programming and parts list, go to:
www.sears.com (U.S.A.) www.sears.ca (Canada)
or call the Kenmore Water Line at
1-800-426-9345
Para obtener el manual detellado de uso y
cuidado, con especificaciones, programaci6n
y lista de piezas, visite el sitio:
www.sears.com (Estados Unidos) www.sears.ca (Canad6)
o Ilame a la linea directa de Kenmore Water al
1-800-426-9345
Pour obtenir un guide d6taill6 d'utilisation
et d'entretien, y compris les sp6cifications,
la programmation, et la liste des pi_ces, visitez :
www.sears.com (l_tats-Unis) www.sears.ca (Canada)
ou appelez la ligne d'assistance de Kenmore au
1-800-426-9345
I{enrnore
d_ Agua
Sears Brands Management Corporation 3333 Beverly Road
Hoffman Estates, IL 60179 U.S.A www.kenmorewater.com www.kenmore.com
www.sears.com
Sears Canada Inc. 290 Yonge Street
Toronto, Ontario M5B 2C3 Canada www.sears.ca
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
P/N 7338268 (Rev. B 10/23/13)
WARRANTY ON KENMORE WATER SOFTENER
ONE YEAR LIMITED WARRANTY ON WATER SOFTENER
When installed, operated and maintained according to all instructions supplied with the product, if this
Kenmore appliance fails due to a defect in material and workmanship within one year from the date of pur-
chase, call 1-800-4-MY-HOME ® to arrange for free repair. TEN YEAR LIMITED WARRANTY AGAINST LEAKS
When installed, operated and maintained according to all instructions supplied with the product, if the water softener tank or salt storage drum develops a leak within ten years from the date of purchase,
call 1-800-4-MY-HOME ®to arrange for free tank or drum replacement. After the first year you must pay an initial trip charge.
All warranty coverage does not include water softener resin, which is an expendable item.
If this appliance is used for other than private family purposes, this warranty applies for only 90 days from
the date of purchase.
This warranty covers only defects in material and workmanship. Sears will NOT pay for:
1. A service technician to instruct the user in correct product installation, operation or maintenance.
2. A service technician to clean or maintain this product.
3. Damage to or failure of this product if it is not installed, operated or maintained according to the all instructions supplied with the product.
4. Damage to or failure of this product resulting from accident, abuse, misuse or use for other than its intend-
ed purpose.
5. Damage to or failure of this product caused by the use of detergents, cleaners, chemicals or utensils other than those recommended in all instructions supplied with the product.
6. Damage to or failure of parts or systems resulting from unauthorized modifications made to this product.
Disclaimer of implied warranties; limitation of remedies
Customer's sole and exclusive remedy under this limited warranty shall be product repair as provided herein.
Implied warranties, including warranties of merchantability or fitness for a particular purpose, are limited to
one year or the shortest period allowed by law. Sears shall not be liable for incidental or consequential dam- ages. Some states and provinces do not allow the exclusion or limitation of incidental or consequential dam-
ages, or limitation on the duration of implied warranties of merchantability or fitness, so these exclusions or limitations may not apply to you.
This warranty applies only while this appliance is used in the United States or Canada. This warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.
Sears Brands Management Corporation, Hoffman Estates, IL 60179 U.S.A. Sears Canada Inc., 290 Yonge Street, Toronto, Ontario MSB 2C3 Canada
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
Read all steps and guides carefully before installing and using your new water softener. Follow all steps exactly to correctly install. Failure to follow them could cause personal injury or property damage.
Reading this manual will also help you to get all the
benefits from your water softener.
Do not attempt to use this product to make safe drinking water from non-potable water sources. Do
not use the system on microbiologically unsafe water, or water of unknown quality without adequate disin-
fection before or after the system.
Check with your local public works department for plumbing and sanitation codes. You must follow
their guides as you install the system. Follow your local codes if they differ with guides in this manual.
In Massachusetts, plumbing code 248-CMR 3.00 and
10.00 shall be adhered to. Consult with a licensed plumber.
Use only lead-free solder and flux for all sweat-sol- der connections, as required by federal codes, when
installing soldered copper plumbing.
Use care when handling the water softener. Do not turn upside down or drop.
Avoid installing in direct sunlight. Excessive heat may cause distortion or other damage to non-metallic parts.
This water softener works on water pressures of 20 psi to 125 psi (In Canada, 100 psi maximum). If your house
water pressure is over the maximum, install a pressure reducing valve in the water supply pipe to the softener.
Temperature of the water supply to the softener must be between 40°F and 120°F. Do not install on hot water.
If installing the water softener outdoors, do not locate where it will be exposed to wet weather, direct sunlight or extreme hot or cold temperatures.
This softener works on 24 volt, 60 Hz electrical power only, supplied by a direct plug-in transformer (includ- ed). Be sure to use the included transformer and plug
it into a nominal 120% 60 cycle household outlet that is properly protected by an overcurrent device such as a circuit breaker or fuse. If transformer is replaced,
use only the authorized service, Class II, 24V 1OVA transformer.
This water softener has a non-metallic valve system.
Installing it on metal plumbing will break electrical continuity, which may interrupt grounding for the
home. You must restore electrical continuity in your metal plumbing system (See Page 9).
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
(Shows sequence of equipment only - not all items are needed in all applications)
Cold Water
to House
Hot Water
to House
Water Water Central Iron Heater Softener Water Filter
Always locate an Iron Filter UPSTREAM of the water softener.
Locate a Central Water Filtration System UPSTREAM of the water softener on a chlorinated water supply, or DOWNSTREAM of the water softener on a non-chlorinated water supply.
j_
Untreated Water to
Outside Faucets
Sediment Cartridge
Filter
Filtration
System
City Water Supply
t
Pressure
Tank OR
_Well Wate! Supply
Well E_
Pump
Figure 1
t
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
3
TYPICAL INSTALLATION
WHERE TO INSTALL THE WATER SOFTENER
Review the following points before you choose a place
to put your softener:
1. Place as close as possible to, but always downstream from, the pressure tank (well water) or water meter
(city water).
2. Place as close as possible to a water drain such as a
floor drain, laundry tub, sump or standpipe (See Fig.
2).
3. Connect to the house main water pipe UPSTREAM
OF THE WATER HEATER (See Fig. 1). The tempera-
ture of water going through the softener must not be
more than 120°F (49°C). Hot water will damage inner softener parts. To reduce the risk of hot water
backup, piping between the softener and water heater should be as long as possible.
4. Keep outside faucets on hard water to save soft
water and salt. See Fig. 2.
5. Do not install in a place where the softener could freeze. Damage caused by freezing voids the war-
ranty by Sears Brands Management Corporation.
6. Put the softener in a place where water damage is
least likely to occur if it develops a leak. Sears or
the manufacturer will not repair or pay for water damage.
7. A grounded, 120V, 60 Hz. electrical outlet is needed near the softener to plug in the transformer
(See Fig. 2). Be sure the outlet and transformer are in an inside location, protected from wet weather.
Use a continuously "live" outlet, which cannot be accidentally switched off.
8. When installing in an outside location, you must take the steps necessary to assure the softener, installation
plumbing, and wiring, are protected from the ele- ments, direct sunlight, contamination, vandalism, etc.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
4
CHECK YOUR WATER PRESSURE BEFORE INSTALLING
For your water softener to work properly, incoming
water pressure in your house pipes must be no lower than 20 pounds per square inch (psi). The highest
allowable pressure is 125 psi (In Canada, 100 psi). If pressure is above the maximum, buy and install a pres-
sure reducing valve in the pipe supplying water to the softener's inlet.
NOTE: If water pressure during the day is 100 psi or
more, pressure during the night may go above 125 psi.
INSTALL SINGLE BYPASS VALVE AND/OR THREADED INSTALLATION ADAPTORS
Complete the following steps to assemble the adaptors and/or the included single bypass valve.
1. Close the shutoff valve on the house main water pipe, near the water meter or pressure tank, to turn off the water.
2. Shut off the gas or electric supply to the water
heater.
3. Open the highest and lowest water faucets in your
house. This will let water drain from the pipes. Close faucets after water has drained.
4. Remove the top cover. Pull outward on the two tabs
to release top cover (see Fig. 3). Set the cover and
salt lid aside so they will not get scratched or bro- ken.
Salt Lid
Top
SINGLE BYPASS VALVE:
6. Lightly coat the o-rings with silicone grease and slide
them onto the bypass valve. Push the bypass valve into the softener valve's inlet and outlet ports as far
as it will go. Snap the two large holding clips into
place, from the top down as shown (see Fig. 6).
CAUTION: Be sure the clips snap firmly into place so
the bypass valve will not pull out.
INLET AND OUTLET THREADED ADAPTORS:
7. Lightly coat the o-rings with silicone grease and slide them onto the installation adaptors. Push the adap-
tors into the valve inlet and outlet ports, or bypass valve ports, as far as they will go. Both adaptors are
the same and fit either port. Snap the two large
holding clips into place, as shown (see Fig. 6).
CAUTION: Be sure the clips snap firmly into place so
the adaptors will not pull out.
Clips
Threaded
Valve Installation Outlet Adaptors
Figure 3
O-Rings
5. Visually check and remove any foreign mate- rials from the valve inlet and outlet ports (see
Fig. 4). Carefully remove the two large plastic
clips (you will use them). Check to be sure the turbine and support are firmly in place
(see Fig. 5).
NOTE: If you will not install the included bypass
valve because you will have a 3-valve bypass in your plumbing, skip step 6, but perform step 7.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
5
INSTALL SINGLE BYPASS VALVE (cont.)
Before installing the bypass valve and/or installation
adaptors, make sure that the turbine and support are firmly in place inside the softener valve's outlet port.
Turbine
Support
Valve Outlet j Turbine /
Figure 5
INSTALL HOLDING CLIPS
Bypass Valve or
Installation Adaptor
Plastic Clip
\
ASSEMBLE INLET AND OUTLET PLUMBING
Measure, cut (thread if needed) and put together all
pipe and fittings up to the main water pipe. Make sure
that the incoming water supply pipe goes to the valve inlet side.
CAUTION: Never solder fittings while connected to
nonmetallic parts. Wait until soldered pipe has cooled before connection. See Fig. 8.
CAUTION: Be careful when putting pipe fittings togeth-
er. Do not cross thread, and do not over- tighten.
______ /Vlain Welter
.
Solder. _ Water NOTE: To be certain
that heat will not travel down the pipe
and into the bypass
valve or installation
adaptors, wrap the bottom of the pipe and the bypass valve
with a wet rag.
Pipe
Incoming Hard
1. Cut pipe to correct length
2. Solder. When
cool, do step 3.
Valve Inlet or Outlet
Plastic clip snaps
into groove in
bypass or adaptor
O-Ring
Figure 6
ALTERNATE BYPASS VALVE INSTALLATION
onnecting to floor
el plumbing, install
bypass valve turned
ownward, as shown
o,um
IN Figure 7
3. Put threaded
y adaptor into
IN bypass valve
Clip
port.
Figure 8
Questions? Call the I<enmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
6
CONNECT THE VALVE DRAIN HOSE
Take a length of 3/8" inside diameter drain tubing (supplied) and attach one end to the drain fitting (see
Fig. 9). Use a tube clamp from the parts bag to hold it
in place. Put the other end of the tubing over a floor drain, into a laundry tub, standpipe, or other suitable
drain. Check your local codes.
Leave an air gap of about 1-1/2" between the end of
the hose and the drain. This gap is needed so you don't get a backflow of sewer water into the softener.
Do not put the end of the hose into the drain or con-
nect without the air gap.
Locate and support the hose so it does not kink or have
sharp bends. Secure the hose end so water pressure does not cause the hose to "whip". Tie or wire it in
place. Do not pinch the hose shut. The softener will not work if this drain hose is pinched, plugged, closed
or restricted in any way. Direct drain flow down into drain from drain line as flow could possibly overshoot
the drain cover.
Keep the hose lower than the drain fitting. In some
homes, to get to a drain you must raise the hose and run it overhead. Do not raise the hose more than 8 feet
above the floor.
COPPER DRAIN TUBE: Local plumbing codes may
require the use a copper valve drain tube. A copper
tube is also best to use if running a drain line overhead. To adapt a copper drain tube to the softener, purchase
a compression fitting (1/4" female pipe threads x 1/2" O.D. tube) and tubing from your local hardware store.
CONNECT SALT TANK OVERFLOW HOSE
1. Locate the rubber grommet, adaptor elbow and tube clamp (see Fig. 9) that are in the parts bag.
2. Push the grommet into the hole in the salt tank wall
so that half is inside and half is outside.
3. Push the larger end of the adaptor into the grommet.
4. Push one end of a length of 3/8" I.D. tubing (sup-
plied) onto the tube adaptor, using a tube clamp from the parts bag to hold it in place.
5. Put the other end of the tubing over the floor drain.
IMPORTANT: Overflow water must run down by gravity
through the tubing. Do not raise the tub- ing higher than the adaptor (see Fig. 9).
IMPORTANT: Do not connect this hose to the valve
drain hose you just installed (see above). Both drains must have a separate hose.
Grommet Tube
] d_ Adaptor
NOTE: Drain Hose
(12 ft.) is included.
_t Drain
ring
Tube ...._ I
Clamp
\\
\\
xx
\\
\\
X\
X\
\\ Todrain
\\
\\ point other
--_,_V'_lv_ _ than floor Drain Hose
Tie or wire 1-1/2" as needed.
tubing in Air Gap
place
Salt Tank
Overflow Hose FLOOR DRAIN
Clip 1/4 NPT
SUBSTITUTING RIGID DRAIN LINE
Threads CompressionFitting, 1/4 NPTx
Barbs 1/2" O.D. Tube(not supplied)
Cut barbs from drain fit- 1/2" Outside
ring {pullclip and remove Diameter Copper
fitting from valve) Tube (not supplied)
..... STANDPIPE
\\
.... ='_ ____:L
drain.
Support tub-
ing in place
Gap
. , Gap
_ LAUNDRY TUB
Figure 9
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
7
LEAK TEST
To check for leaks, complete the following steps: CAUTION: To avoid water or air pressure damage to
softener inner parts, and to flush pipe chips or other residue from the water pipes, be
sure to do the following steps exactly as instructed.
1. Fully open two nearby cold water faucets down- stream from the softener.
2. Place bypass valve(s) in "bypass" position (see
Figures 10 & 11). On a single valve, slide the stem inward to bypass. On a 3-valve bypass, close the
inlet and outlet valves and open the bypass valve.
3. Fully open the house main water pipe shutoff valve.
Observe steady water flow from both open faucets.
4. Place bypass valve(s) in SERVICE, EXACTLY as fol-
lows: Keep soft water faucets open.
a. Single Bypass Valve: Slowly, slide pull the valve
stem outward toward service, pausing several times
to allow the softener to pressurize gradually.
b. 3-Valve Bypass: Fully close the bypass valve and open the outlet valve. Slowly open the inlet valve,
pausing several times to allow the softener to pres- surize gradually.
5. After about three minutes, open a hot water faucet
for about one minute, or until all air is expelled, then close.
6. Close both cold water faucets.
7. Check your plumbing work for leaks, and fix right
away if any are found. Be sure to observe previous caution notes.
SINGLE BYPASS VALVE
FOR SERVICE
Close bypass valve.
Open inlet & outlet
valves.
FOR BYPASS
Open bypass valve.
Close inlet & outlet
valves.
Pull stem outward
3-VALVE BYPASS
Outlet
Valve
for Service
Push inward
for Bypass
Figure 10
Bypass Valve
Inlet Valve
Figure 11
NOTE: If this procedure is performed on a new softener,
water coming from the taps may initially be dis- colored. This normally occurs the first time
water runs through the resin bed. The discol- ored water is not harmful, and the discoloration
will not last more than a few minutes.
Questions? Call the I<enmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
METAL WATER PIPE GROUNDING
IMPORTANT: This water softener has a non-metallic
valve system. Installing it on metal
plumbing will break electrical continuity,
which may interrupt grounding for the
home. You must restore electrical conti- nuity in your metal plumbing system.
If you installed a 3-valve bypass system (Fig. 11),electri-
cal continuity will be maintained. If you installed the non-metallic bypass valve (Fig. 10), restore the ground
as follows:
METAL PIPE GROUNDING
(parts not included)
Ground Wire
/
Install a #4 copper wire (parts not included) across the
removed section of metal water pipe, securely clamping it at both ends (See Fig. 12). Be sure the pipes are
clean under the clamps, to assure good contact. NOTE: If you are installing a sediment filter or other
item(s) into the plumbing system, along with the water softener, be sure to restore electrical con-
tinuity across all removed metal pipe sections.
INSTALL COVERS
After installing your water softener, put the covers on. Angle the covers so the top cover clips onto the back
first, then bring down in front and clip on the tabs inside the rim and lower the salt lid closed (See Fig. 3).
CONNECT TO ELECTRICAL POWER
The softener works on 24 volt, 60 Hz electrical power. The included transformer changes standard 120 volt AC
house power to 24 volts. You must plug the water soft- ener's transformer into a grounded, 120 volt outlet only.
Be sure the outlet is always "live" so it cannot be
switched off by mistake. NOTE: The electrical outlet you plug the transformer
into must be indoors, protected from weather.
Figure 12
RESTART THE WATER HEATER
Turn on the gas (or electric) supply to the water heater and light the pilot.
YOUR PLUMBING INSTALLATION AND
ELECTRICAL WORK ARE NOW COMPLETE.
Questions? Call the I<enmore Water Line 1-800-426-9345 or visit www.kenmorewater.com
9
SANITIZETHEWATERSOFTENER
1. Open salt lid, remove the brinewell cover and pour about 3 oz. (6 tablespoons) of household bleach into the softener brinewell. Replace the brinewell cover.
2. Make sure the bypass valve(s) is in the "service"
(open) position.
3. Start a recharge: Press the REGENERATION button
and hold for 3 seconds, until "RECHARGE", "Serv" and "Fill" begin to flash in the display. This recharge draws the sanitizing bleach into and through the water softener. Any air remaining in the unit is
purged to the drain.
4. After the recharge has completed, fully open a cold
water faucet, downstream from the softener, and
allow 50 gallons of water to pass through the sys- tem. This should take at least 20 minutes. Close the
faucet.
Your new Sears softener is now softening the water for your household needs. However, your WATER HEATER is filled with hard water. To have fully soft water right away, you can drain the water heater so it refills with soft water. If you don't drain the water heater, it will take a few days before you have fully soft water.
NOTE: If this procedure is performed on a new softener,
water coming from the taps may initially be dis- colored. This normally occurs the first time water runs through the resin bed. The discol- ored water is not harmful, and the discoloration
will not last more than a few minutes.
PROGRAM THE SOFTENER
Lift the salt lid and follow the instructions on the decal
to program the following into the electronic controller:
Current time of day
Hardness of your water supply
Time of day when automatic recharges will begin
Type of salt you will be using (only on select models)
NOTE: You can find complete instructions for programming the softener and customizing features of the electronic
controller in the owner's manual. Go to www.sears.com or call 1-800-426-9345.
ADDING SALT TO THE STORAGE TANK
You must keep salt in the tank, but it is not necessary to fill it full. Especially in humid areas, it is best to fill the storage tank no more than half full, and to add salt more often. Salt "bridging" occurs more often when
conditions are humid. Use NUGGET or PELLET water softener salt. DO NOT
use rock salts, as they have dirt and sediments that will stop the softener from working. To maintain optimum
performance of your water softener, the salt tank should be cleaned out every 2 to 3 years.
In the state of California: You must turn the Salt Efficiency Feature setting to ON. This may initiate
more frequent recharges. However, it will operate at 4,000 grains per pound of salt or higher. To turn on the Salt Efficiency Feature, follow the instructions in the "Salt Efficiency" section of the owner's manual.
POTASSIUM CHLORIDE (I(CI) SALT
If you choose Potassium Chloride (KCI) as a regenerant,
following these suggestions will help give you years of
maintenance free service.
1. Place only one bag of I<CI in your softener at a time (the salt storage tank should contain no more than
60 pounds of KCI at any one time).
2. A softener using KCI should not be placed in areas
with temperature fluctuations and high humidity (KCI will harden in these environments and may make the softener inoperable).
3. On select models, set "Salt Type" on the controller to
"KCI". This setting adjusts the regeneration cycle times to compensate for the different rate at which
KCI dissolves. If your softener does not have a KCI salt setting, you must increase your hardness setting
by 25% to ensure continuous soft water.
Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewaterocom
10
Loading...