Kenmore 580.72127200, 580.72087200 Owner's Manual

Owner's Manual Manual del Propietario
®
THROUGH-THE-WALLAIRCONDITIONER ACONDICIONADODEAIREA TRAVESDEPARED
ModeI, Modelo 580.72087200 580.72107200 580.72127200
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com
Features ................................................. 13
ImportantSafety Instructions...................... 3
Installation Requirements ......................... 5
Installation ................................................ 6
Procedure A ............................................. 7
Procedure B ............................................. 9
Procedure C ........................................... 11
OPERATION ...........................................12
How and Why ......................................... 12
Normal Sounds ...................................... 12
Capacity and Running Time ................... 12
Using the Air Conditioner ....................... 13
Air Conditioner Features ........................ 14
MAINTENANCE .....................................16
Air Filter Cleaning ................................... 16
Air Conditioner Cleaning ........................ 16
How to Remove the Front Grille ............. 16
How to Replace the Front Grille ............. 16
TROUBLESHOOTING .........................17
Before Calling for Service ...................... 17
ESPANOL ................................................18
MASTER PROTECTION
AGREEMENTS ......................................35
SERVICE NUMBERS ............ Back Cover
FULL ONE YEAR WARRANTY ON THROUGH-THE-WALL AIR CONDITIONER
For one year from the date of purchase, when this air conditioner is operated and maintained for
normal room cooling according to instructions in this owner's manual, Sears will repair this air conditioner, free of charge, if defective in material or workmanship.
WARRANTY SERVICE IS AVAILABLE BY
CONTACTING SEARS SERVICE AT 1-800-4-MY-HOME ®.
This warranty applies only while this product is in
use in the United States.
This warranty gives you specific legal rights, and
you may also have other rights which vary from state to state.
Sears, Roebuck and Co., D/817WA,
Hoffman Estates, IL 60179 U.S.A.
-2-
IMPORTANT SAFETY INSTRUCTIONS
The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER.
V!_W:_:t_II_[_FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Read product labels for flammability and
other warnings.
PREVENT ACCIDENTS
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow
basic precautions, including the following:
Be sure the electrical service is adequate for the model you have chosen.
If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a
screen panel included, you may want to remove the screen completely before installation.
Be sure the air conditioner has been securely and correctly installed according to the instructions in this manual.
Save this manual and installation instructions for possible future use in removing or reinstalling this
unit.
Use gloves when handling the air conditioner. Be careful to avoid cuts from sharp metal fins on
front and rear coils.
V!_W,.1;i_ll_[dELECTRICAL INFORMATION
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the
rating when checking the electrical requirements.
Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
Your air conditioner must be plugged into a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately
grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle.
Do not run air conditioner with packing sheet of the back of the sleeve, and packing corner and
blue tape of the air conditioner. This could result in mechanical damage within the air conditioner.
Do not use an extension cord or an adapter plug.
_ Avoid fire hazard or electric shock.
Do not use an extension cord or an adapter plug. Do not remove any prong from the power cord.
Grounding type
wall receptacle
grounding plug
Do not under any circumstances cut, remove, or bypass the grounding prong
from this plug.
ENERGY SAVING IDEAS
The capacity of the room air conditioner must fit the room size for efficient and satisfactory
operation.
install the room air conditioner on the shady side of your home. A window that faces north is best
because it is shaded most of the day.
Do not block air flow inside with blinds, curtains, or furniture; or outside with shrubs, enclosures, or other buildings.
Close the floor and wall registers and the fireplace damper so cool air does not escape up the chimney and into the duct work.
Keep blinds and drapes in other windows closed during the sunniest part of the day.
Clean the air filter as recommended in the
MAINTENANCE section of this manual.
Proper insulation and weather stripping in your home will help keep warm air out and cool air in.
External house shading with trees, plants or awnings will help reduce the air conditioner's work
load.
Operate heat producing appliances such as ranges, washers, dryers, and dishwashers during the coolest part of the day.
-3-
OBSERVEALL LOCAL CODES AND
ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE.
A 208/230-volt and 115-volt 60 Hz, AC only,
15A fused and properly grounded electrical supply is required. A time delay fuse or time delay circuit breaker is recommended. Use a dedicated circuit, serving only this appliance.
DO NOT USE AN EXTENSION CORD. RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must be grounded. This appliance has a power
supply cord with a 3-prong grounding plug. To minimize possible shock hazard, the cord must
be plugged into a mating grounding type wall receptacle and grounded in accordance with
the National Electrical Code (ANSt/NFPA 70) latest edition and all local codes and
ordinances. If a mating wall receptacle is not available, it is the personal responsibility and
obligation of the customer to have a properly grounded 3-prong wall receptacle installed by a
qualified electrician.
Electrical Shock Hazard Plug into a grounded 3 prong outlet.
Do not remove ground prong. Do not use an adapter.
Do not use an extension cord. Failure to follow these instructions can result
in death, fire, or electrical shock.
Ground prong I/! _ 'fl
/ 3-prong
_..k I \"--J I grounding
,J-prong _ I _ ] type wall
gg.rounalng k _'T'F I receptacle
Power_ "_
supply
cord
-4-
INSTALLATION REQUIREMENTS
If you use an existing wall sleeve, you should
measure its dimensions. install the new air conditioner according to these
installation instructions to achieve the best performance. All wall sleeves used to mount the
new air conditioner must be in good structural
condition and have a rear grille to securely attach the new air conditioner. (FIG. 1)
With the Kenmore folding sleeve, you can
maintain the best performance of the new air
conditioner.
19-2//32"
(499 mrn)
Air Conditioner
ELECTRICAL SERVICE
Check your available electrical service. The power
supply available must be the same as that shown on the unit nameplate (found on left side of cabinet).
All models are equipped with a 3-prong service plug to provide proper service and safe positive grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does not match your plug, call a qualified electrician to
make the necessary corrections. SAVE CARTON
for storage and this OWNER'S MANUAL for future
reference. The carton is the best way to store unit
during winter or when not in use.
(626 ram)
6mrn)
FIG. !
INSTALLATION HARDWARE
j 2 Size options
; s,zeo t,on
ITEM NAME OF PARTS Q'TY
(1_ PLASTIC GRILLE 1
HORIZONTAL iNSULATION STRIPS 2 AROUND INSULATION STRIPS 2
suPPORTBLOCK 2
BAFFLE 1
_6_ TRIM FRAME 2
SHIM 2
_8_ PLASTIC NUTS AND WASHER SCREWS 4
To avoid riskof personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
Air conditioners covered in this manual pose an excessiveweight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
Carefully inspectlocation where air conditioner
will be installed. Be sure itwill support the weight of the unitover anextended periodof time.
Handle air conditioner with care. Wear protective gloves whenever lifting or carryingthe
unit. AVOID the sharp metal fins offront and rear coils.
Make sure air conditioner does not fall during installation.
REQUIRED TOOLS:
Tight Fitting gloves
Standard screwdriver
Phillips screwdriver
Pliers
Sharp knife
-5-
3/8-inch open end wrench or adjustable
wrench
1/4-inch hex socket
and ratchet
Tape measure
Electric drill
1/4-inch drill bit
INSTALLATION
We strongly recommend the removal of the
oldwall sleeve and the installationof a new Kenmore folding Wall Sleeve,
If you decide to keep the existing wall sleeve,
you haveto redirect the louvers at the back of the wall sleeve illustration. The use of pliers is
recommended. If you DO NOT redirect, you run
the risk of poor performance or product failure. This is not covered under the terms of the
Kenmorewarranty.
Pick a location which will allow the conditioned air to blow into the area you want. Good installation with
special attention to the proper position of the unit will
lessen the chance that service will be needed.
Assemble the folding sleeve for this unit according to
the instructions provided.
ITEMS IN INSTALLATION HARDWARE
You may not need all parts in the kit. Discard unused
_arts
ITEM (inches)
Plastic grille Horizontal insulation Strips
Around insulation Strips
Support Block 13/4x 13/8 x 45/18
Baffle 14 x 41/2 x 1/8
Shim 13 x 1 x 3/4 Trim Frame Washer Screw
Nuts(Plastic)
263/4 x 161/2
13/8x 5/8x 273/18 13/8x 13/8 x 273/18
13/8X 3/4X 611/2 13/8X 13/8 X 611/2
Qty.
1 1
1 1
1
2
1
2 2
4 4
HOW TO INSTALL
NOTE: All wall sleeves used to mount the new Air
Conditioner must be in sound structural condition and have a rear grille that securely attaches to
sleeve, or rear flange that serves as a stop for the Air Conditioner,
I_11 Remove old air conditioner from existing wall
sleeve.
I_j Clean the interior of an existing sleeve.
(Do not disturb seals.)
D Wall sleeve must be securely fastened in wall
before installing the air conditioner. Use the nails or screws through sleeve into wall, if needed. Repaint sleeve if needed.
I_ Prepare the wall sleeve for installation of the
unit. If you plan to use your existing wall sleeve, and it is not Kenmore, use procedure B or C
below.
Procedure Brand Depth(inches)
A Sears/Kenmore 16-23/32
White-Westinghouse
Frigidaire Carrier 16, 17-1/2
(52F series)
B General Electric
/Hotpoint
Whirlpool 17-1/8 or 23 Carrier (51S series) 18-5/8
Fedders/Emerson
C
Q Install new unit into wall sleeve. CAUTION: When installation is completed,
replacement unit MUST have a rearward slope as shown.
Emerson/Fedders 15 Friedrich 16-3/4
or 22
16-7/8
16-3/4
or 19-3/4
O Identify the existing wall sleeve before installing
the unit from the listed below.
Brand
White-Westinghouse
Frigidaire Carrier (52F series) General Electric
/Hotpoint
Whirlpool 25-7/8
Fedders/Emerson 27
Sears/Kenmore 25-7/8
Emerson/Fedders 26-3/4 Carrier (51S Series) 25-3/4
Friedrich 27
Wall Sleeve Dimensions (inches)
Width
25-1/2
26
Height Depth
15-1/4 16, 17-1/2
15-5/8 16-7/8
16-1/2
16-3/4 16-3/4
15-17/32 16-23/32
15-3/4 15 16-7/8 18-5/8
16-3/4 16-3/4
or 22
17-1/8
or 23
or 19-3/4
UNIT Wall Sleeve
1/4"__j
FIG. 2
-6-
PROCEDURE A
D Install the new unit into the wall sleeve.
O If you are using a new Kenmore folding sleeve
with your unit, skip to step 3. Otherwise, install the plastic grille from the kit. Cut the plastic
grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the inside of the wall sleeve at the rear flange.
FIG. 3
B Fasten the 4 washer screws to secure the grille
to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation
kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of the rear flanges.
_41To assemble trim, snap the tab of each piece
into the slot of the other piece as shown below. Slide trim over the front of the air conditioner
until trim is flush with sleeve as shown below.
Trim (2 ea)
Wall
or
_1 Remove the backing from the Horizontal
Insulation strip 13/8X 3/8X 273/16 and attach that to the inside bottom of the sleeve as shown
below. Remove the backing from the Around Insulation strip 13/8X 3/4X 611/2 and attach that
to the inside front of the sleeve as shown below.
FIG. 6
FIG. 4
Air conditioners covered in this manual pose an excessive weight hazard. Two or more
people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and
rear coils.
Make sure air conditioner does not fall during
removal.
FIG. 5
-7-
PROCEDURE B
H Redirect the louvers at the back of the wall
sleeve to 60 ° angle as shown in the FIG 7. The use of pliers is recommended.
7 51/6"
_6_
Rear Louvers
(Top View)
FIG. 7
_lf the wall sleeve already has a rear grille, skip
to step 4. If the wall sleeve does not have a rear grille or Iouvered panel, install the plastic grille
from the kit. Cut the plastic grille to 25-1/2" wide and 15-1/4" high. Place the plastic grille to the
inside of the wall sleeve at the rear flange.
_J Remove the backing from the Horizontal
insulation strip 13/8 x 5/8 x 273/16 and attach that
to the inside bottom of the sleeve as shown
below. Remove the backing from the Around insulation strip 13/8 x 3/4 x 611/2 and attach that to
the inside front of the sleeve as shown below.
FIG. 10
_Jlf the depth of your existing wall sleeve is less
than or equal to 18", skip to step 7. Otherwise,
cut the baffles and the support blocks according
to length "A" in the table below.
Depth"D"oftheexisting wallsleeve(inches)
18 <D _<18-5/8
18-% <D_<19-3/4
19-3/4<D _<22
Length"A"
(inches)
3/4
1-3/4
4
_ upport
Block
_[_ Baffle
FIG.11
Place the plastic grille
_J Fasten the 4 washer screws to secure the grille
to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall sleeve, there are plastic nuts in the installation
kit. The nuts are installed from the inside of the sleeve and are pressed into the square holes of
the rear flanges.
or
Fasten the screws
FIG. 8
FIG. 9
r_ Remove the backing from the support blocks
and attach them to the inside of the wall sleeve as shown FIG 8. Slide the baffle into slots of the
support blocks.
Wall
Sleeve
H Install the new unit into the wall sleeve.
-8-
(7 5Sl6")
Support
Block
FIG. 12
PROCEDURE B
_JTo assemble trim, snap the tab of each piece
into the slot of the other piece as shown below. Slide trim over the front of the air conditioner
until trim is flush with sleeve as shown below.
Wall
FIG. 13
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and
rear coils.
Make sure air conditioner does not fall during removal.
-9-
PROCEDURE C
H Redirect the louvers at the back of the wall
sleeve to 60 ° angle as shown in the FIG 14. The use of pliers is recommended.
7 13,/6 **
Lt0°
Rear Louvers
(Top View)
FIG. 14
_J Remove the backing from the Horizontal
insulation strip 13/8 x 13/8 x 273/16 and attach that
to the inside bottom of the sleeve as shown
below. Remove the backing from the Around insulation strip 13/8 x 13/8 x 611/2 and attach that
to the inside front of the sleeve as shown below.
I_lf the wall sleeve already has a rear grille, skip
to step 4. If the wall sleeve does not have a rear grille or Iouvered panel, install the plastic grille
from the kit. Cut the plastic grille to 26-1/2" wide and 15-1t2" high. Place the plastic grille to the
inside of the wall sleeve at the rear flange.
Place the plastic grille
I[_ Fasten the 4 washer screws to secure the grille
to the wall sleeve. If you need plastic nuts to mount plastic grille to the inside of the wall
sleeve, there are plastic nuts in the installation kit. The nuts are installed from the inside of the
sleeve and are pressed into the square holes of the rear flanges.
FIG. 15
FIG. 17
If the depth of your existing sleeve is less than
El
or equal to 18", skip to step 7. Otherwise, cut the baffles and the support blocks according to
Length "A" in the table below.
Depth"D"of the existing wailsleeve(inches)
18 <D_<18-%
18-5/8<D <19-3/4
19-3/4<D <_22
r_ Remove the backing from the support blocks
and attach them to the inside of the wall sleeve as shown FIG 19. Slide the baffle into slots of
the support blocks
Length"A"
(inches)
3/4
1-3/4
4
_ upport
Block
_ Baffle
FIG. 18
13_/6" )
Wall
Sleeve
or
Fasten the screws FIG. 16
-10-
PROCEDURE C
W Remove the backing from the 13" shim strips
and attach them as shown below in Fig. 21. The higher portion of shim is to be placed in front of the rib on the base of wall sleeve.
h'0h E--' 'I'"0h
FIG. 20
FIG. 21
_r_ Install the new unit into the wall sleeve
_"_To assemble trim, snap the tab of each piece
into the slot of the other piece as shown below. Slide trim over the front of the air conditioner
until trim is flush with sleeve as shown below.
Trim (2 ea)
Wall
[!_ [_f_,_liI [.] _I
Air conditioners covered in this manual pose an excessive weight hazard. Two or more people are needed to move and install the unit. To prevent injury or strain, use proper lifting and carrying techniques when moving unit.
When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and
rear coils.
Make sure air conditioner does notfall during removal.
-11-
FIG. 22