For one year from the?date of purchase, when this
air conditioner is operated and maintained for
normal room cooling according to instructions in this
owner's manual, Sears will repair this air
conditioner, free of charge, if defective in material or
workmanship.
FULL FIVE-YEAR WARRANTY ON
SEALED REFRIGERATION SYSTEM
For five years from the date of purchase, when this
air conditioner is operated and maintained for
normal room cooling according to instructions in this
owner's manual, Sears will repair the sealed
refrigeration system (consisting of refrigerant,
connecting tubing, and compressor), free of charge,
if defective in material or workmanship.
WARRANTY SERVICE IS AVAILABLE BY
CONTACTING THE NEAREST SEARS
SERVICE CENTER IN THE UNITED STATES.
Warranty coverage applies only to air conditioners
used for non-commercial, private household
purposes.
This warranty applies only while this product is in
use in the United States.
This warranty gives you specific legal rights, and
you may also have other right which vary from state
to state.
Sears, Roebuck and Co., D/817WA,
Hoffman Estates, IL 60179 U.S.A.
-2-
SAFETY
IMPORTANT SAFETY INSTRUCTIONS
The safety instructions below wilt tell you how to use your room air conditioner to avoid harm to yourself or
damage to your ROOM AIR CONDITIONER.
Awarning
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance. Read product labels for flammability and
other warnings.
Awarning
To reduce the risk of fire, electrical shock, or injury
to persons when using your air conditioner, follow
basic precautions, including the following:
• Be sure the electrical service is adequate for the
model you have chosen.
• If the air conditioner is to be installed in a window,
you will probably want to clean both sides of the
glass first. If the window is a triple-track type with a
screen panel included, you may want to remove
the screen completely before installation.
• Be sure the air conditioner has been securely and
correctly installed according to the separate
installation instructions provided with this manual.
Save this manual and installation instructions for
possible future use in removing or reinstalling this
unit. .
• When handling the air conditioner, be careful to
avoid cuts from sharp metal fins on front and rear
coils.
Awarning
The complete electrical rating of your new room air
conditioner is stated on the serial plate. Refer to the
rating when checking the electrical requirements.
• Be sure the air conditioner is properly grounded.
To minimize shock and fire hazards, proper
grounding is important. The power cord is
equipped with a three-prong grounding plug for
protection against shock hazards.
• Your air conditioner must be plugged into a
properly grounded wall receptacle. If the wall
receptacle you intend to use is not adequately
grounded or protected by a time delay fuse or
circuit breaker, have a qualified electrician install
the proper receptacle.
• Do not run air conditioner with outside protective
cover in place. This could result in mechanical
damage within the air conditioner.
• Do not use an extension cord or an adapter
plug.
FOR YOUR SAFETY
PREVENT ACCIDENTS
ELECTRICAL INFORMATION
Awarning
Do not use an extension cord or an adapter plug.
Do not remove any prong from the power cord.
Grounding type
wall receptacle
Avoid fire hazard or electric shock.
Do not under any
circumstances cut,
remove, or bypass
the grounding prong
from this plug.
Power supply cord '
with 3-prong
grounding plug
ENERGY SAVING IDEAS
• The capacity of the room air conditioner must fit
the room size for efficient and satisfactory
operation.
• Install the room air conditioner on the shady side
of your home. A window that faces north is best
because it is shaded most of the day.
• Do not block air flow inside with blinds, curtains, or
furniture, or outside with shrubs, enclosures, or
other buildings.
• Close the floor and wall registers and the fireplace
damper so cool air does not escape up the
chimney and into the duct work.
• Keep blinds and drapes in other windows closed
during the sunniest part of the day.
• Clean the air filter as recommended in the
MAINTENANCE section of this manual.
• Proper insulation and weather stripping in your
home will help keep warm air out and cool air in.
• External house shading with trees, plants or
awnings will help reduce the air conditioner's work
load.
• Operate heat producing appliances such as
ranges, washers, dryers, and dishwashers during
the coolest part of the day.
-3
ELECTRICAL REQUIREMENTS
OBSERVE ALL LOCAL CODES AND
ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
A 115-volt 60 Hz, AC only, 15A fused and
properly grounded electrical supply is required.
A time delay fuse or time delay circuit breaker
is recommended. Use a dedicated circuit,
serving only this appliance.
DO NOT USE AN EXTENSION CORD.
RECOMMENDED GROUNDING METHOD
For your personal safety, this appliance must
be grounded. This appliance has a power
supply cord with a 3-prong grounding plug. To
minimize possible shock hazard, the cord must
be plugged into a mating grounding type wall
receptacle and grounded in accordance with
the National Electrical Code (ANSI/NFPA 70)
latest edition and all local codes and
ordinances. If a mating wall receptacle is not
available, it is the personai responsibility and
obligation of the customer to have a properly
grounded 3-prong wall receptacle installed by a
qualified electrician.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result
in death, fire, or electrical shock.
‘3-prong
grounding
type wall
receptacle
cord
-4-
INSTALLATION
INSTALLATION REQUIREMENTS instal l a tio n h a r d w a r e
Your air conditioner wül install into standard double
hung windows with actual clear opening widths of
27 to 39 inches (686mm to 990mm) (FIG. 1).
Lower sash must open sufficiently to allow a clear
vertical opening of 16 inches (406mm). Side louvers
and the rear of the air conditioner must have clear
air space to allow enough airflow through the
condenser for heat removal. The rear of the unit
must be outdoors, not inside a building or garage.
■ Sasti
- Window
-Offset
Sill
■ Exterior
FIG. 1
ELECTRICAL SERVICE
Check your available electrical service. The power
supply available must be the same as that shown
on the unit nameplate (found on right side of cabinet).
All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections.
SAVE CARTON and this OWNER'S MANUAL for
future reference. The carton is the best way to store
unit during winter or when not in use.
A CAUTION
To avoid risk of personal injury, properly damage.
or product damage due to the weight of this
device and sharp edges that may be exposed:
• Air conditioners covered in this manual pose an
excessive weight hazard. Two or more people
are needed to move and install the unit.
To prevent injury or strain, use proper lifting and
carrying techniques when moving unit.
• Carefully inspect location where air conditioner
will be installed. Be sure it will support the
weight of the unit over an extended perior of
time.
• Handle air conditioner with care. Wear
protective gloves whenever lifting or carrying the
unit. AVOID the sharp metal fins of front and
rear coils.
• Make sure air conditioner does not fall during
installation.
ITEM
A
B
C
D
E
F
G
H
1
J
REQUIRED TOOLS:
Tight Fitting gloves
Standard screwdriver
' Phillips screwdriver
■ Pliers
■ Sharp knife
■ 3/8-inch open end wrench or adjustable wrench
' 1/4-inch hex socket and ratcher
' Tape measure
' Electric drill
' 1/4-inch drill bit
NAME OF PARTS
SIDE CURTAIN
SILL SUPPORT
BOLT
LOCK NUT2
SCREW; 25/64"
SCREW: 5/8"
SCREW: 5/8"
FOAM SEAL
FOAM STRIP
L BRACKET
Q'TY
2
2
2
13
3
5
1
1
1
- 5 -
INSTALLATION
INSTALLATION
Pick a location which will allow you to blow the cold
air into the area you want. Windows used for
installation must be strong enough to support the
weight of the air conditioner. Good installation with
special attention to the proper position of the unit
will lessen the chance that service will be needed.
When cooling more than one room, installation
location is very important since cold air will not turn
corners. To cool your rooms, cold air must be blown
from the air conditioner in a straight path.
HOW TO INSTALL
Remove the screws which fasten the cabinet at
both sides and at the back. Save side screws.
Discard back screws.
insert the side curtain (ITEM A) into the upper
guide and lower guide of the air conditioner. Fasten
the curtains to the unit with screws (ITEM E).
window inner sill (or desired air conditioner location).
Carefully place the cabinet on the window inner sill
and align the center mark on the angle front with the
center line marked in the window inner sill.
Slide the unit out of the cabinet by gripping the
base pan handle and pull forward while bracing the
cabinet.
Cut the FOAM STRIP (ITEM I) to fit the
underside of the window sash. Peel off the backing
and attach the FOAM STRIP as shown in Fig. 5.
k!l Pull the bottom window sash down behind the
upper guide until they meet.
NOTE: Do not pull the window sash down so tightly
that the movement of side curtain is restricted.
Loosely assemble the sill supports using the
parts in FIG. 9.
INSTALLATION
Select the position that will place the sill
supports near the outermost point on sill (FIG. 10).
Attach the sill supports to the cabinet track hole
closest to the selected position using screw ITEM E,
Lower guide
FIG, 10
Place the sill supports with the cabinet on the
window sill's selected position.
KE
The cabinet should be installed with a very slight
tilt {about 1/4") downward toward the outside (FIG. 11).
Adjust the bolts and the nuts of sill supports to level
the cabinet.
ED Attach the cabinet to the inner sill by driving the
screws (ITEM F) through tine front lower guide into
^Sasti
Tfack
Be sure to insert the drain pipe into base pan before
installation.
The air conditioner must be installed with a slight tilt
to the outside for proper water drainage.
The air conditioner will drain the excess condensed
water through the drain pipe. (FIG. 15)
-BASE PAN REAR
DRAINPIPE
tZ^ZZZZZZZZZZZZ2i
BASE PAN BOTTOM
CIH
iCi Slide the air conditioner into the cabinet. (FIG. 16)
CAUTION; For security purposes, reinstall side screws
you removed in step 1.
FIG. 15
^—lowef Guide
ITEM B ^
m Pull each side curtain fully to each side of
window opening. Attach each side curtain to the
window sash using screws (ITEM G). (FIG. 13)
m Attach the L bracket (ITEM J) with screw
(ITEM G). (FIG. 14)
ITEMF
FIG. 12
Cut the foam seal (ITEM H) to the proper
length and insert between the upper window sash
and the lower window sash. (FIG. 17)
ITEM H
iB
The vent control handle must be straightened
before the decorative front is attached.
-7
FIG. 17