Kemppi MIG 2530 User Manual

Kempact
MIG 2530
Operating manual
Käyttöohje
Bruksanvisning
Bruksanvisning
Brugsanvisning
Gebrauchsanweisung
Gebruiksaanwijzing
Manuel d’utilisation
Instrukcja obsługi
Инструкции по эксплуатации
EN
FI
SV
NO
DA
DE
NL
FR
ES
PL
RU
操作手册
Manual de utilização
Manuale d’uso
ZH
PT
IT
OPERATING MANUAL
English
EN
CONTENTS
1. Preface ...................................................................................................................................... 3
1.1 General ....................................................................................................................................... 3
1.2 Product introduction ............................................................................................................ 3
2. Before you start using the unit ............................................................................... 3
2.1 Unpacking ................................................................................................................................. 3
2.2 Placement of the unit ........................................................................................................... 3
2.3 Serial number ........................................................................................................................... 4
2.4 Connection to the mains supply ...................................................................................... 4
2.5 Distribution network ............................................................................................................. 4
2.6 Ground cable ............................................................................................................................ 4
2.7 Wire feeding mechanism components .......................................................................... 4
2.8 Installation of welding gun ................................................................................................. 6
2.9 Mounting and locking of wire reel .................................................................................. 6
2.10 Automatic wire feed to gun................................................................................................ 6
2.11 Adjustment of pressure ........................................................................................................ 6
2.12 Adjustment of tightness of reel brake ............................................................................ 7
2.13 Shielding gas ............................................................................................................................ 7
3. Operation ............................................................................................................................... 8
3.1 Main switch and signal lights............................................................................................. 8
3.2 To select polarity for welding ............................................................................................ 8
3.2.1 Changing the polarity ..................................................................................................... 8
3.3 Panel ............................................................................................................................................ 9
3.4 Selecting the welding procedure (2T/4T) ..................................................................... 9
3.5 Adjusting welding dynamics ...........................................................................................10
3.6 Thermostat ..............................................................................................................................10
3.7 Wire feed switch ....................................................................................................................10
4. Maintenance ......................................................................................................................11
4.1 Daily maintenance ...............................................................................................................11
4.2 Regular maintenance ..........................................................................................................11
4.3 Disposal of the machine ....................................................................................................11
5. Ordering numbers .........................................................................................................11
6. Technical data ...................................................................................................................12
2
Kempact MIG 2530
1. PREFACE
1.1 General
Congratulations on choosing Kempact series welding equipment. Used correctly, Kemppi products can signicantly increase the productivity of your welding, and provide years of economical service.
This operating manual contains important information on the use, maintenance and safety of your Kemppi product. The technical specications of the equipment can be found at the end of the manual.
Please read the operating manual and the safety instructions booklet carefully before using the equipment for the rst time. For your own safety and that of your working environment, pay particular attention to the safety instructions in the manual.
For more information on Kemppi products, contact Kemppi Oy, consult an authorised Kemppi dealer, or visit the Kemppi web site at www.kemppi.com.
For Kemppi’s standard safety instructions and warranty terms and conditions, please visit our web site at www.kemppi.com.
The specications presented in this manual are subject to change without prior notice.
NOTE! Items in the manual that require particular attention in order to minimise damage and
personal harm are indicated with this symbol. Read these sections carefully and follow their instructions.
Disclaimer
While every eort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the specication of the product described at any time without prior notice. Do not copy, record, reproduce or transmit the contents of this guide without prior permission from Kemppi.
EN
1.2 Product introduction
The Kempact MIG 2530 is compact MIG inverter suitable for repair and installation use, and for light and medium industrial use. The power source and the wire feeding mechanism are contained in the device. The power regulation of the power source is implemented with IGBT transistors operating at a frequency of approximately 30 kHz.
Disclaimer
While every eort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions. Kemppi reserves the right to change the specication of the product described at any time without prior notice. Do not copy, record, reproduce or transmit the contents of this guide without prior permission from Kemppi.
2. BEFORE YOU START USING THE UNIT
2.1 Unpacking
The equipment is packed in durable packages, designed specially for it. Nevertheless, before using the equipment, always make sure it was not damaged during transport. Also check that you have received what you ordered and that there are instructions for it. NOTE! The packaging material of the products is suitable for recycling.
2.2 Placement of the unit
Place the unit on a horizontal, solid, and clean surface. Shield it from heavy rain and scorching sun. Make sure that cooling air circulates freely.
© Kemppi Oy / 1204
3
EN
2.3 Serial number
The serial number of the unit is marked on the rating plate of the unit. The serial number makes it possible to trace product manufacturing series. You might need the serial number when placing spare parts orders or when planning maintenance.
2.4 Connection to the mains supply
The Kempact 2530 is equipped with a ve metre mains cable without a plug. Installation of the plug should be carried out only by a competent electrician. For fuse and cable sizes, see the technical data in the end of this document.
2.5 Distribution network
All regular electrical devices without special circuits generate harmonic currents into distribution network. High rates of harmonic current may cause losses and disturbance to some equipment.
WARNING: This equipment does not comply with IEC 61000-3-12. If it is connected to a public
low voltage system, it is the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be connected.
2.6 Ground cable
Fasten the earth clamp of the return current cable carefully, preferably direct onto the piece to be welded. The contact surface of the earth clamp should always be as large as possible. Clean the fastening surface from paint and rust. Use at least 35 mm² cables. Thinner cross-sectional areas cause overheating of connectors.
2.7 Wire feeding mechanism components
1.
2.
3.
4.
5.
1. Clamp screw
2. Clamping lever
3. Feed rolls
4. Gun connector (Euro)
5. Wire guides
4
Kempact MIG 2530
DuraTorque™ 400, 4 wheel wire feed mechanism
Wire guide tubes
Ss, Al, Fe, Mc, Fc
Fe, Mc, Fc ø 0,6 ... 0,8 mm ø 1.0/67 mm,
ø 0,6 ... 1,6 mm ø 2.5/64 mm,
W000762, silver, plastic
ø 1,6 ... 2,4 mm ø 3.5/64 mm,
W001430, silver, plastic
W001432, white, steel
ø 0,9 ... 1,6 mm ø 2.0/64 mm,
W001433, orange, steel
ø 1,6 ... 2,4 mm ø 4.0/63 mm,
W001434, blue, steel
2.
ø 2.5/33 mm, W000956, silver, plastic
ø 3.5/33 mm, W001431, silver, plastic
ø 2.0/33 mm, W001435, orange, steel
ø 4.0/33 mm, W001436, blue, steel
ø 2.0 mm, W000624, plastic
ø 3.5 mm, W001389, plastic
ø 2.0 mm, W000624, plastic
ø 3.5 mm, W001389, plastic
ø 3.5 mm, W001391, brass
EN
Wire feed rolls
Fe, Ss, Al, V-groove
Fe, Fc, Mc, knurled
Fe, Fc, Mc, Ss, Al, U-groove
1.
ø mm Colour Drawing Pressing
0.6 pale grey W001045 W001046
0.8/0.9 white W001047 W001048
1.0 red W000675 W000676
1.2 orange W000960 W000961
1.4 braun W001049 W001050
1.6 yellow W001051 W001052
2.0 grey W001053 W001054
2.4 black W001055 W001056
1.0 red W001057 W001058
1.2 orange W001059 W001060
1.4/1.6 yellow W001061 W001062
2.0 grey W001063 W001064
2.4 black W001065 W001066
1.0 red W001067 W001068
1.2 orange W001069 W001070
1.6 yellow W001071 W001072
© Kemppi Oy / 1204
5
EN
2.8 Installation of welding gun
Make sure the gun wire conduit and the ow nozzle match the manufacturer’s recommendations for the type and diameter of wire you use. Too small a conduit may overload the wire feed device and disturb the wire feeding. Tighten the gun quick connector to eliminate voltage losses. A loose joint will make the gun and the wire feeder warm.
NOTE! Do not use a damaged gun.
2.9 Mounting and locking of wire reel
LOCKED OPEN
• Release locking nails of wire reel hub by turning locking knob a quarter round.
• Mount the reel at its place. Note rotating direction of reel!
• Lock the reel with locking knob, locking nails of hub remain to outside position and will
lock the reel.
2.10 Automatic wire feed to gun
Automatic wire feed makes change of wire reel more rapid. In reel change the pressure of feed rolls need not to be released and ller wire goes automatically to correct wire line.
• Make sure that groove of feed roll matches the diameter of welding wire used.
• Release the wire end from reel and cut o the bent length. Be careful that the wire does
not spill from the reel to sides!
• Straighten about 20 cm of the wire and see that the end of it has no sharp edges (le o if necessary). A sharp edge may damage the wire guide tube and contact tip of the welding gun.
• Draw a bit of loose wire from wire reel. Feed wire through back liner to feed rolls. Do not release pressure of feed rolls!
• Press the gun switch and feed a bit wire until wire goes through feed rolls to gun. See that wire is in grooves of both feed roll pairs!
• Press still the gun switch until wire has come through contact tip.
Automatic feed may sometimes fail with thin wires (Fe, Fc, Ss: 0.6...0.8 mm, Al: 0.8...1.0 mm). In that case you might have to open feed rolls and feed wire manually through feed rolls.
NOTE! Check that the wire or wire reel does not touch the equipment body, there is a danger of
short circuit
6
2.11 Adjustment of pressure
Adjust the pressure of feed rolls with the control screw so that the wire is fed into the wire guide tube evenly and allows a little braking when coming out from the contact tip without slipping at the feed rolls.
NOTE! Excessive pressure causes attening of the ller wire and damage to the coating. It also
causes undue wear of the feed rolls as well as friction.
Kempact MIG 2530
2.12 Adjustment of tightness of reel brake
A
Brake force is adjusted through hole in locking device of reel hub by screwing the control screw (A) with screwdriver.
Adjust brake force as so big that the wire is not allowed to become too loose on the reel so that it would spill from the reel when the rotation of the reel stops. Need for brake force is increased with increase of wire feed speed.
Since the brake loads for its part the motor, you shouldn’t keep it unnecessarily tight.
2.13 Shielding gas
The MIG shielding gas consists of carbon dioxide, mixed gases and argon. Shielding gas ow rate is determined by the amount of welding current. The typical ow rate of gas in the welding of steel is 8–15 l / min.
The following installation instructions are valid for most gas ow regulator types:
EN
A C
Parts of gas ow regulator
A. Gas bottle valve B. Pressure regulation screw C. Connecting nut D. Hose spindle E. Jacket nut F. Gas bottle pressure meter G. Gas hose pressure meter
F
G
B
E D
1. Step aside and open the bottle valve (A) for a while to blow out possible impurities.
2. Turn the press regulation screw (B) of the regulator until no spring pressure can be felt.
3. Close the needle valve if there is one in the regulator.
4. Install the regulator on bottle valve and tighten the connecting nut (C) with a wrench.
5. Install the hose spindle (D) and jacket nut (E) into the gas hose and tighten with a hose clamp
6. Connect the hose with the regulator and the other end with the wire feed unit. Tighten jacket nut.
7. Open the bottle valve slowly. The gas bottle pressure meter (F) shows bottle pressure.
© Kemppi Oy / 1204
7
EN
NOTE! Do not use the whole contents of the bottle. Bottle should be lled when bottle pressure is
2 bar.
8. Open the needle valve if there is one in the regulator.
9. Turn the regulation screw (B) until the hose pressure meter (G) shows the required ow (or pressure). When regulating the ow amount, the power source should be switched on and the gun switch pressed simultanously.
NOTE! Close the bottle valve after welding is nished. If the machine will not be in use for a long
time, unscrew the pressure regulation screw. Always fasten the gas ottle tightly in vertical position, to a wall stand or bottle cart, specially designed for it. For safety reasons, always remove the gas bottle from the transport stand of the machine before lifting of transport of the machine by car!
3. OPERATION
3.1 Main switch and signal lights
With the switch in the ‘I’ position, the primary and control circuits of the machine become live and the ‘ON’ signal light on the panel lights up. The welding circuit receives voltage when the gun switch is operated or when the wire feed test switch is pressed.
Always use the main switch to turn the machine on and o with the main switch; do not use the power plug for this purpose.
3.2 To select polarity for welding
Solid wire is usually welded in + pole and cored wire in – pole gun. Check for the recommended polarity on the package or consult the supplier of the product. The welding of very thin plates (0.5 to 0.7 mm) – polarity might also work best for solid wire.
3.2.1 Changing the polarity
1. – pole
2. + pole
NOTE! Only a service shop authorised by Kemppi may change the polarity.
1.
2.
8
Kempact MIG 2530
3.3 Panel
Adjusting voltage and wire feed speed
The welding voltage can be adjusted from 10 to 30 V, and the wire feed speed from 1 to 18 m/min. Adjust the values appropriately by using the table of guideline values on the door of the wire compartment and by testing.
1.
2.3.
6.
EN
4.
5.
1. ON signal light
2. Thermostat signal light
3. Selecting welding procedure (2T/4T)
4. MIG welding dynamics adjustment
5. Wire feed adjustment
6. Welding voltage adjustment
3.4 Selecting the welding procedure (2T/4T)
2T: MIG welding with double action of the start switch of the gun:
1. Switch closed – welding starts.
2. Switch open – welding ends.
4T: MIG welding with quadruple action of the start switch of the gun:
1. Switch closed – ow of shielding gas starts.
2. Switch open – welding starts.
3. Switch closed – welding ends.
4. Switch open – ow of shielding gas ends.
© Kemppi Oy / 1204
9
3.5 Adjusting welding dynamics
The adjustment of MIG welding dynamics inuences the properties of the welding arc and the amount of splatter. The recommended basic setting is ‘0’. The values -> min (-1...-9) provide a softer arc for diminishing the amount of spatter. The values -> max (1...9) provide a coarser arc, suitable when increased arc stability is desired and when using 100% CO₂ shielding gas for welding steel.
EN
3.6 Thermostat
The temperature control of the machine prevents the power source from over-heating.This means that the machine can not become damaged if loading exceeds the specied load factor during welding. When the signal lamp indicating overheating is lit, the welding circuit can not be activated. The lamp will turn o after a pause of about three minutes, and welding can be started again in the usual way by pressing gun switch.
3.7 Wire feed switch
10
The wire feed switch will start the wire feed motor without opening the gas valve. The power source will start up, but without providing welding power.
Kempact MIG 2530
4. MAINTENANCE
4.1 Daily maintenance
NOTE! Be careful of mains voltage when handling electric cables!
Clean the wire channel of the electrode and check the contact tip regularly. Always check the condition of the mains and welding cable before operation and replace defective cables.
NOTE! Only a competent electrician is allowed to remove or install the mains cable!
4.2 Regular maintenance
KEMPPI -service workshops sign special service contracts with customers for regular maintenance. All parts are cleaned, checked and if necessary, repaired. Also the operation of the welding machine is tested.
4.3 Disposal of the machine
Do not dispose of electrical equipment with normal waste! In observance of European Directive 2002/96/EC on waste electrical and electronic
equipment, and its implementation in accordance with national law, electrical equipment that has reached the end of its life must be collected separately and taken to an appropriate environmentally responsible recycling facility.
The owner of the equipment is obliged to deliver a decommissioned unit to a regional collection centre, per the instructions of local authorities or a Kemppi representative. By applying this European Directive you will improve the environment and human health.
EN
5. ORDERING NUMBERS
Kempact MIG 2530 GH 30 Gun holder MMT 25 MMT 25 MMT 27 MMT 27 Earth cable 35 mm² Transport unit ST 7 Transport unit P250 Lift hook Wire spool pole 5 kg spool adapter Gas hose
621853002
6256030
3 m 6252513MMT
4.5 m 6252514MMT
3 m 6252713MMT
4.5 m 6252714MMT
5 m 6184311
6185290
6185268
4298180
4289880
4251270
6 m W000566
© Kemppi Oy / 1204
11
EN
6. TECHNICAL DATA
Kempact MIG 2530 Connection voltage Rated power at max. current Supply current
Connection cable Fuse (delayed) Output 40 °C
Welding range Open circuit voltage Power factor at max. current Efficiency at max. current Wire feed speed Filler wires
Shielding gas Wire spool (max. ø) Thermal class External dimensions Weight Operating temperature range Storage temperature range EMC class Degree of protection Standards
IEC/EN 60974-1 IEC/EN 60974-5 IEC/EN 60974-10
3~, 50/60Hz 380 – 440V ±10%
40% ED 250 A / 12 kVA
I
1max
I
1e
H07RN-F 4G1.5 (5 m)
40% ED 250 A /26.5 V
60% ED 207 A / 24 V
100% ED 160 A / 22 V
Fe, Ss ø 0.6 – 1.0 mm
Cored wire ø 0.9 – 1.2 mm
Al ø 0.9 – 1.2 mm
Cusi ø 0.8 – 1.0 mm
LxWxH 580x280x440
17 A
11 A
16 A
10 – 30 V
30 – 45 V
0.64
87%
1 – 18 m/min
CO₂, Ar, Ar & CO₂ mixed gases
300 mm (15 kg)
H(180 °C) / B (130 °C)
20 kg
-20 °C ... +40 °C
-40 °C ... +60 °C
A
IP23S
12
Kempact MIG 2530
KEMPPI OY
Kempinkatu 1 PL 13 FIN-15801 LAHTI FINLAND Tel +358 3 899 11 Telefax +358 3 899 428 export@kemppi.com www.kemppi.com
Kotimaan myynti:
Tel +358 3 899 11 Telefax +358 3 734 8398 myynti.@kemppi.com
KEMPPI SVERIGE AB
Box 717 S-194 27 UPPLANDS VÄSBY SVERIGE Tel +46 8 590 783 00 Telefax +46 8 590 823 94 sales.se@kemppi.com
KEMPPI NORGE A/S
Postboks 2151, Postterminalen N-3103 TØNSBERG NORGE Tel +47 33 346000 Telefax +47 33 346010 sales.no@kemppi.com
KEMPPI DANMARK A/S
Literbuen 11 DK-2740 SKOVLUNDE DANMARK Tel +45 4494 1677 Telefax +45 4494 1536 sales.dk@kemppi.com
KEMPPI BENELUX B.V.
Postbus 5603 NL-4801 EA BREDA NEDERLAND Tel +31 765717750 Telefax +31 765716345 sales.nl@kemppi.com
KEMPPI (UK) Ltd
Martti Kemppi Building Fraser Road Priory Business Park BEDFORD, MK44 3WH UNITED KINGDOM Tel +44 (0)845 6444201 Telefax +44 (0)845 6444202 sales.uk@kemppi.com
KEMPPI FRANCE S.A.S.
65 Avenue de la Couronne des Prés 78681 EPONE CEDEX FRANCE Tel +33 1 30 90 04 40 Telefax +33 1 30 90 04 45 sales.fr@kemppi.com
KEMPPI GmbH
Otto-Hahn-Straße 14 D-35510 BUTZBACH DEUTSCHLAND Tel +49 6033 88 020 Telefax +49 6033 72 528 sales.de@kemppi.com
KEMPPI SPÓŁKA Z O.O.
Ul. Borzymowska 32 03-565 WARSZAWA POLAND Tel +48 22 7816162 Telefax +48 22 7816505 info.pl@kemppi.com
KEMPPI AUSTRALIA PTY LTD.
13 Cullen Place P.O. Box 5256, Greystanes NSW 2145 SMITHFIELD NSW 2164 AUSTRALIA Tel. +61 2 9605 9500 Telefax +61 2 9605 5999 info.au@kemppi.com
OOO KEMPPI
Polkovaya str. 1, Building 6 127018 MOSCOW RUSSIA Tel +7 495 739 4304 Telefax +7 495 739 4305 info.ru@kemppi.com
ООО КЕМППИ
ул. Полковая 1, строение 6 127018 Москва Tel +7 495 739 4304 Telefax +7 495 739 4305 info.ru@kemppi.com
KEMPPI, TRADING (BEIJING) COMPANY, LIMITED
Room 420, 3 Zone, Building B, No.12 Hongda North Street, Beijing Economic Development Zone, 100176 Beijing CHINA Tel +86-10-6787 6064 +86-10-6787 1282 Telefax +86-10-6787 5259 sales.cn@kemppi.com
肯倍贸易(北京)有限公司 中国北京经济技术开发区宏达 北路12号 创新大厦B座三区420室 (100176) 电话: +86-10-6787 6064 +86-10-6787 1282 传真: +86-10-6787 5259
sales.cn@kemppi.com
KEMPPI INDIA PVT LTD
LAKSHMI TOWERS New No. 2/770, First Main Road, Kazura Garden, Neelankarai, CHENNAI - 600 041 TAMIL NADU Tel +91-44-4567 1200 Telefax +91-44-4567 1234 sales.india@kemppi.com
www.kemppi.com
1910184
1204
Loading...