Kemppi ARC Euro Adapter-CV Quick Manual

ARC Euro Adapter -CV
Quick guide
The ARC Euro Adapter allows you to use Kemppi's WeldEye welding management software for monitoring any welding machine equipped with a Euro connector. For more information about Kemppi's welding quality management solutions, please visit www.weldeye.com.
1. Three wire liners are included in the package. Select one of them according to the ller wire size you are using, and install the liner into the adapter.
2. Connect the ARC Euro Adapter to the Euro connector on the wire feeder. Push the connector and turn clockwise until it's rmly seated.
3. Connect the welding gun to the ARC Euro Adapter. Push the connector and turn clockwise until it's rmly seated.
4. Attach the ARC Control Cable to the adapter and turn clockwise until it is rmly seated.
The plug installation and all installations inside Kemppi welding machines may be carried out only by an authorized electrician.
The maximum allowed welding current is 500 A.
The 'CV' stands for the qualities being measured (Current and Voltage).
8.
1. L1
1. L2
1. L3
5. Connect the ARC Control Cable to the Adapter Power Source.
6. Connect the Smart Reader or the Digital Connectivity Module (DCM) to the ARC Control Cable.
7. Connect the branch connector to the welding equipment and connect the voltage sensing cable between the branch connector and the Adapter Power Source.
8. Install the plug and plug in the Adapter Power Source to a 220 – 415 V wall socket. Alternatively the Adapter Power Source can be connected to the mains connector inside the power source.
9. Test that the system works.
1.
2.
5.
3.
7.
4.
6.
(Turn the page for a full setup overview.)
Wire path maintenance
You must know the correct tension torques before you start repairing the connections.
Only an authorised electrician may repair the machine.
To service or change the wire guide, remove the 3 adaptor bushes.
SP011107 wire guide set
1 pc wire guide (0.8 – 1.0)
1 pc wire guide (1.0 – 1.4)
1 pc wire guide (1.2 – 1.6)
1 pc adaptor bush
1 pc adaptor bush
1 pc adaptor bush
Clean every three months:
Clean the parts from dust and dirt e.g. with a soft brush and avacuum cleaner. Do not use compressed air because there is the danger that the dirt is packed even more tightly in the gaps of the cooling proles. Do not use a pressure washer.
Three wire guide sizes are available in packages of 5 pcs.
Wire guides
wire ø mm guide markings length colour pcs code
0.8 – 1.0 KEMPPI 5.9/1.5 120 orange 5 W007111
1.0 – 1.4 KEMPPI 5.9/2.0 120 orange 5 W007112
1.4 – 1.6 KEMPPI 5.9/2.5 120 orange 5 W007113
B
F
A
A. Arc control cable
2 m 6185940
25 m 6185941
50 m 6185942
B. Voltage sensing cable
1.5 m SP007898
C. Universal Sensor
MMA KIT
D. Digital Connectivity
Module (DCM)
E. Smart Reader 6265043
F. Adapter power
source
SP008897
6265051
6185950