Keithley 7012 Datasheet

Page 1
7012-C 7012-S
4×10 2-pole matrix
Available with screw terminal or
mass terminated connections
Rows connect to 7001/7002
backplane for easy matrix expandability
500nV, 100pA offsets
Use with 7001 and 7002 switch mainframes
Ordering Information
7012-C 4×10, 2-Pole
7012-S 4×10, 2-Pole Matrix
FOR 7012-C
7011-KIT-R 96-pin Female Connector Kit 7011-MTC-1 96-pin Mass Terminated Cable, Female to
7011-MTC-2 96-pin Mass Terminated Cable, Female to
Matrix with 96-pin Mass Terminated Connector Board
with Screw Terminal Connector Board
ACCESSORIES AVAILABLE
Female, 1m
Female, 2m
4×10 Matrix Cards
The 7012 provides 4 rows by 10 columns of 2-pole matrix switching. The four rows of this card can be connected to the analog backplane within the 7001 or 7002 to make a larger matrix (4×20) or use it with the 7011 multiplexer card for greater flexibility through row expansion. Each row is connected to the backplane with its own jumpers that can be removed to isolate an individual row from the backplane.
MATRIX CON FIG U R A TION: 4 rows by 10 columns. Jumpers can be removed to isolate any row
from the backplane.
CONTACT CON FIG U R A TION: 2-pole Form A (Hi, Lo). CONNECTOR TY PE:
7012- C: 96-pin male DIN connector. 7012-S: Screw terminal, #16AWG maximum wire size, with .092 inch O.D. 28 conductors
per card maximum. #22AWG typical wire size with .062 inch O.D. 88 conductors per card maximum.
MAXIMUM SIGNAL LEVEL:
DC Signals: 110V DC between any t wo pins, 1A switched. 30VA (re sis tive load).
AC Signals: 125V rms and 175V AC peak, between any two pins, 1 A switched, 60VA (resistive load). COMMON MODE VOLTAGE: 175V peak, any pin to chassis. CONTACT LIF E: Cold Switching: 10 CHANNEL RESISTANCE (per conductor): <1W. CONTACT POTENTIAL:
7012- C: <1µV per channel contact pair 7012-S: <500nV per channel contact pair
<3µV typical per single contact. <1.5µV typical per single contact.
OFFSET CURRENT: <100pA. ACTUATION TIME: 3ms. ISOLATION: Path: >109W, <50pF. Differential: >109W, <200pF. Common Mode: >109W, <4 00pF. CROSSTALK (1MHz, 50W Load): <–40dB. INSERTION LOSS (50W Source, 50 Load): <0.1dB below 1MHz, <3dB below 2MHz. RELAY DRIVE CURRENT (per relay): 16m A. EMC: Conforms to European Union Directive 89/336/EEC. SA FE TY: Conforms to European Union Directive 73/23/EEC (meets EN61010-1/IEC 1010). ENVIRONMENT: Operating: 0° to 50°C, up to 35°C <80% RH. Storage: –25°C to 65°C.
1 2 3 4 5 6 7 8 9 10
B
C
D
HI
8
closures. At Maximum Signal Levels: 105 closures.
J
Backplane
J
Backplane
J
Backplane
J
Backplane
Use with 7001 and 7002 switch mainframes
SERVICES AVAILABLE
7012-C-3Y-EW 1-year factory warranty extended to 3 years
7012-S-3Y-EW 1-year factory warranty extended to 3 years
1.888.KEITHLEY
from date of shipment
from date of shipment
(U.S. only)
www.keithley.com
Matrix Crosspoint
LO
SWITCHING AND CONTROL
A Greater Measure of Confidence
Loading...