Keating Of Chicago 2006 series, 10x11 BB, 14 BB, 18 BB, 20 BB User Manual

...
1-800-KEATING
www.keatingofchicago.com
Users Manual
INSTANT RECOVERY®ELECTRIC FRYER SERIES 2006
READ AND SAVE THIS MANUAL FOR FUTU RE R EFE RENCE.
INTROD UCTION
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
STAN DARD FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
MODEL VARIATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
INSTALLATION
DAMAGE DURING SHIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
DROP-IN INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
POSITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
LEVELING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
RESTRAINING DEVICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
ELECTRICAL CONNECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
WIRE SIZE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
OPERATING THE FRYER
FILLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
MELTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
COOKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6
SHUTDOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
DRAINING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-7
CLEANING AND BOIL-OUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8
ELECTRONIC TIMERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
MAINTENANCE
WARRANTY REPAIRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
PREVENTIVE MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
OIL BREAKDOWN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
LIMITED CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
THERMOSTAT BULB POSITIONING . . . . . . . . . . . . . . . . . . . . . . . .9
SERVICE DIAGNOSIS
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
TROUBLE SHOOTING CHARTS . . . . . . . . . . . . . . . . . . . . . . .10-11
PARTS LIST
ORDERING PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
WARNING AND OPERATING PLATES . . . . . . . . . . . . . . . . . . . . .12
ELECTRIC FRYER PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
ELECTRIC FRYER ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
BB CONTROL PANEL PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . .14
TS CONTROL PANEL PARTS LIST . . . . . . . . . . . . . . . . . . . . . .15-17
CPU CONTROL PANEL PARTS LIST . . . . . . . . . . . . . . . . . . . .18-19
BASKET-LIFT HOUSING AND
ROLLER GUIDE & PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . .20-21
WIRING D IAGRAM S
SINGLE BASKET LIFT POWER SUPPLY BOX . . . . . . . . . . . . . . .22
BB WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23-28
TS WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-35
CPU WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35-36
FRYER SPECIFICATIONS
BB MODELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
TS MODELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
CONTENTS:
IMPORTANT:
Keep a copy of your bill of sale. The date on the bill establishes the warranty period should service be required. If service is performed, it is in your interest to obtain and keep all receipts. Keating commercial fryers are not intended for household use.
The Owner’s Guide provides specific operating instructions for your model. Use the Instant Recovery
®
Electric Fryer only as instructed in this Owner’s Guide.
electricFryer2006
06/12
part# 057641
RECORD THE MODEL AND SERIAL
NUMBERS OF THIS INSTANT RECOVERY
®
ELECTRIC FRYER IN THE SPACES PROVIDED.
SERIAL NO. ______________________________
MODEL NO. _____________________________
KEEP THESE NUMBERS FOR FUTURE REFERENCE.
i
This operating, installation, and service manual should be given to the user. The operator of the fryer should be familiar with the functions and operation of the fryer. This manual must be kept in a prominent, easily reachable location near the fryer.
Keating of Chicago, Inc. (manufacturer) reserves the right to change specifications at any time.
*As continuous product improvement occurs, specifications may be changed without notice.
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
FOR YOUR SAFETY, DO NOT STORE GASOLINE OR ANY OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
POST THIS LABEL IN A
PROMINENT LOCATION ON
YOUR UNIT.
WARNING
Improper installation can cause damage, injury or death.
WARNING
Do not store flammable
liquids near this or any
other appliance.
1
INTRODUCTION
GENERAL
Instructions in this manual should be read thoroughly before attempting to operate this Keating Electric Fryer. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel.
Operating information for Keating equipment has been prepared for use by qualified and/or authorized personnel.
Keating equipment is made in the U.S.A. and has American sizes of hardware. All metric conversions are approximate.
STANDARD FEATURES
Highly polished stainless steel fryer vesselHighly polished stainless steel frontHighly polished stainless steel elementsHighly polished stainless steel thermostat bulbHighly polished stainless steel Hi-Limit sensorTrue Cold Zone for proper sedimentationGrid screen over elementsMelt cycle1” full port front drain valve on 10x11 and 14;
1-1/4” for 18 and larger
High temperature limit control with manual resetPatented accurate temperature control system ±7°FIdeal 35” working heightOne pair of split baskets or one full-size basket (18”
model only)
Circuit breaker protection for 208-240V 10×11 to
34×24 Models.
STANDARD ACCESSORIES
Keating Klenzer SampleKeating Sea Powder SampleDrain clean out rod
STANDARD FRYERS
Sizes: 10×11 to 34×24Oil capacity 30 to 210 poundsNSF, ETL and ETLS listed.
MODEL VARIATIONS
BB Model: BB Model Fryers feature Power On
indicating light, a melt cycle and an electric stainless steel thermostat. The 14BB model can cook up to 72 lbs. of frozen fries or 75 lbs. of chicken per hour.
TS Model: TS Model Fryers have the highest input of all Keating fryers. The TS Model features a melt cycle, and electric stainless steel thermostat, two electronic timers and three indicating lights which display the status of the fryer’s operation. The 14TS Model can cook up to 90 lbs. of frozen fries or 75 lbs. of chicken per hour.
TS Basket-Lift Model: TS Basket-Lift Model Fryers come with all the same features as the TS Model. The Basket-Lift mechanism lowers the baskets of food into the oil when the timer button is pressed and raises the baskets when the cooking cycle is complete. Split baskets are used for all models.
CM Model: BB and TS Counter Model Fryers are equipped with all of the same features as the BB and TS Models respectively, but take up less than three square feet of counter space. The 10x11CM Model can cook up to 36 lbs. of frozen fries per hour and the 14CM Model can cook up to 72 lbs. per hour.
CPU Model: CPU Model Fryers have the same input as the TS Models, and features an over max temperature light. A programmable computer replaces the two timers and thermostat.
SAFETY PRECAUTIONS
THIS SYMBOL WARNS YOU THAT SERIOUS BURNS OR OTHER INJURIES MAY RESULT IF SAFETY INSTRUCTIONS ARE NOT FOLLOWED.
This service manual should be retained in a safe place
for future reference. The installation of your new fryer must conform to current codes, with the current National Electrical Codes and regulations as applicable.
Your ventilation hood, when installed, must conform to
the current standards.
You must maintain this appliance free and clear from
combustibles.
Adequate clearance for servicing and proper operation
must be maintained. Your fryer is designed to be serviced from the front.
Keating commercial fryers are not intended for household
use.
ALWAYS instruct new employees on proper fryer operation.A fryer should be operated ONLY by properly trained
personnel.
ALWAYS turn fryer off each night.ALWAYS turn fryer off at customer power panel before
servicing.
NEVER leave a fryer unattended during operation.NEVER move a fryer when full of hot oil.NEVER introduce objects or liquids into fryer, while
operational, which are not designed or made for cooking.
THIS FRYER MAY NOT BE ALTERED, MODIFIED OR
CHANGED IN ANY WAY.
2
IMPROPER INSTALLATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ THESE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.
INSTALLATION
This fryer MUST be installed, inspected, calibrated and serviced by qualified and/or certified and/or licensed service personnel - you may void your Keating warranty if installation is not completed per local, national and Keating specifications. Contact your dealer for assistance.
IF EQUIPMENT ARRIVES DAMAGED
Keating does not assume responsibility for loss or damage incurred in transit.
IMPORTANT
This merchandise has been thoroughly inspected and carefully packed before leaving our plant. Responsibility for its safe delivery was assumed by the carrier at the time of shipment. Claims for loss or damage to the contents should, therefore, be made upon the carrier, as follows:
CONCEALED LOSS OR DAMAGE
Concealed loss or damage means loss or damage which does not become apparent until the merchandise has been unpacked. The contents may be damaged in transit due to rough handling even though the carton may not show external damage. When the damage is discovered upon unpacking, make a written request for inspection by the carrier’s agent within fifteen days of the delivery date. Then file a claim with the carrier since such damages are the carrier’s responsibility. By following these instructions carefully, we guarantee our full support of your claims to protect you against loss from concealed damage.
VISIBLE LOSS OR DAMAGE
Any external evidence of loss or damage must be noted on the freight bill or express receipt, and signed by the carrier’s agent. Failure to adequately describe such external evidence of loss or damage may result in the carrier refusing to honor a damage claim. The form required to file such a claim will be supplied by the carrier.
DO NOT RETURN DAMAGED MERCHANDISE TO KEATING. FILE YOUR CLAIM AS ABOVE.
INSTALLATION
Installation must conform with local codes or, in absence of local codes, with the current National Electrical Codes and regulations as applicable.
NOTE: For safety purposes, all Hi-Limit controls are
manually reset. Always check the Hi-Limit reset button before attempting to use the fryer. It is possible that the Hi-Limit button may have been accidentally activated on a new fryer while in transit.
DROP-IN FRYER INSTALLATION NOTES
1. All drop-in fryers must be 16” from any open flame.
2. Fryers must be located no more than 5” from counter top front.
3. Cabinet must be reinforced to support full weight of fryer in use (fryer, oil, food).
4. Fryers must be properly ventilated and located under an exhaust hood.
DROPPING THE FRYER INTO THE COUNTER TOP
It is only necessary to place the fryer in such a position that the front edge overlaps the front raised edge of the opening.
Push the fryer forward as far as it will go holding the fryer on approximately a 15° angle, and then drop the rear of the fryer into its proper position lowering it down gently so you do not deform the table or equipment stand.
“A” “B”
10×11DI ELECTRIC 13” 211/4
14DI ELECTRIC 16” 231/2
18DI ELECTRIC 20” 29”
5/8"
5/8"
5/8"
CUT LINE
"A"
"B"
BEND UP 90° ON ALL SIDES TO FINAL OPENING SIZE ("A" X "B"), THEN CLOSE CORNERS BY WELDING AN INSERT PIECE (OR OTHER SUITABLE METHODS) FOR A LEAK FREE FIT.
45°
TYP.
DETERMINED BY CUTTING TOOL
USED
5/8"
1/8"
Figure 2-1
POSITIONING
The fryer must be placed under an exhaust hood with a fire retardant system. Your ventilation hood, when installed, must conform to the current standards. ALL connections and placement must comply with current local and national codes. It is the responsibility of the owner and local installer to comply with these regulations when installing the fryer.
Counter model and floor model fryers must be restrained to prevent tipping when installed in order to avoid splashing, spilling, etc. of hot liquid. The restraining method may be a manner of installation or by separate means.
LEVELING
The fryer will operate at its highest efficiency when properly leveled. Place a level on fryer vessel from side to side. For fryers on legs, the bottom foot of the leg is adjustable. Looking from the bottom of the foot, turn clockwise to decrease height or counter clockwise to increase height until level. For fryers on casters, the casters are adjustable by loosening the jam nut and turning the caster in or out. When the desired level is reached, tighten the jam nut. Adjustments of more than
3
/
4” are not recommended on any caster. The same
procedure should be followed to level the fryer from front to back.
Figure 2-2
RESTRAINING DEVICES
On fryer installations with casters, casters and jam nuts must be completely tightened. Adequate means must also be provided to limit the movement of the appliance.
ELECTRICAL
CONNECTION
The Keating Instant Recovery®Electric fryer is equipped with a three wire terminal block for customer connections. The terminal block is located behind the fryer door on the right side behind a panel (held in place by two screws). Compare the fryer terminal connections to the appropriate wiring diagram for the fryer (see pages 22 thru 35) to see if the fryer is connected three phase or single phase. All wires/cords, plugs, receptacles and circuit breakers must be sized adequately for the full load rating of the fryer as specified by local codes, or in the absence of local codes, by the current National and Canadian Electrical Codes as applicable.
The Keating Electric Fryer is also equipped with a grounding lug next to the terminal block. For proper grounding procedures, see local codes or, in the absence of local codes, by the current National and Canadian Electrical Codes as applicable.
NOTE: A copy of your wiring diagram is shipped with
your equipment.
NOTE: For fryers rated at 208-240 volts, the
amperage ratings marked on the nameplates of the fryers are listed at 240 volts as required by ETL. If your fryer is to be fed by a 208 or 220 volt system, consult the Keating Fryer Specifications on pages 36 and 37 to determine the full load rating of the fryer.
NOTE: Fryers with Safe & Easy®Filters (model
BBSE or TSSE) or Central Filters will have separate 120 volt control circuit connections.
NOTE: A copy of your wiring diagram is located on
the inside of the door.
NOTE: A hole has been punched in the rear of the
fryer cabinet for a cord or conduit exit. If a cord is used, the National Electrical Code, ETL standards and most local codes require a bushing or strain relief (not provided by Keating) to protect the cord.
3
LEVEL
LEG
CASTER
4
WIRE SIZE
Use the table below to help determine the proper wire size for electrical service hook-up. Use the largest amp value of the three conductors for 3-phase installations when using the table. The amperage values for a product can be found on its serial number tag. Consult the National Electrical Code Handbook for additional information or to help answer questions about wire size selection.
*For runs greater than 75' up to 125', use the next wire size larger to keep the voltage drop to less than 3%. For runs greater than 125', consult the National Electrical Code Handbook to help determine the proper wire size.
**2/0 wire ambient temperature must be kept at less than 104°F (40°C).
CALIBRATION
For Calibration refer to page 8 - Calibration.
OPERATING
FILLING
NOTE: Before filling the fryer make certain the fryer
vessel is sanitized, dry and the drain valve is completely closed. Refer to figure 3-3 on page 6 for location of drain valve
.valve.
BE SURE THE HEATING ELEMENTS ARE COMPLETELY COVERED WITH OIL BEFORE SWITCHING THE FRYER ON. IF OIL LEVEL DROPS BELOW TOP OF HEATING ELEMENTS, SEVERE DAMAGE TO FRYER AND INJURY TO OPERATOR MAY RESULT.
WATER IN ANY FORM AND HOT OIL DON’T MIX!!!
Oil expands when heated. The “Max Level” line has been provided to ensure optimum cooking while ensuring the safety of the operator. Do not overfill the fryer vessel.
Figure 3-1
Fill Level Line
BB & TS, CPU and Basket-Lift Models
1. Fill the fryer vessel with oil up to the “Max Level” line.
2. If using solid shortening, remove screen and firmly pack solid shortening between the heating elements. Proceed to Melting section for instructions on use of the melt cycle.
Conductor
Current (Amps up to)
Recommended
wire size (AWG)
15 14* 20 12* 30 10* 40 8 55 6 70 4
95 2 125 0 145 2/0 165 2/0** 190 2/0**
5
MELTING
The Keating Melt Cycle safely melts solid shortening in the fryer vessel without scorching.
BEFORE APPLYING POWER TO THE FRYER, MAKE SURE THE ELECTRIC CONNECTIONS ARE SECURE AND THE FRYER HAS BEEN PROPERLY FILLED WITH OIL.
A. BB, TS and Basket-Lift Models
1. Set the thermostat to the desired temperature.
2. If using solid shortening, set Melt-Fry switch to the “MELT” position. Stay in the “MELT” cycle until the shortening has melted completely and is at the “Max Level” line before switching to the “FRY” position for cooking.
B. CPU Models
*See separate computer instructions or call 1-800-KEATING.
NOTE: During the “MELT” cycle, the elements are on
for approximately 5-7 seconds and off for approximately 50 seconds.
COOKING
Keating Instant Recovery®Electric Fryers are designed to provide maximum production efficiency and deliver high quality food products. Low-temperature cooking, highly polished stainless steel and a true COLD ZONE mean extended oil life. Follow cooking procedures below for your model.
OPERATION OF THIS FRYER SHOULD BE LIMITED TO PERSONNEL WHO HAVE BEEN THOROUGHLY TRAINED IN OPERATING PROCEDURES.
USE ONLY KEATING APPROVED BASKETS IN YOUR FRYER. NEVER OVERFILL FRY BASKETS. DO NOT BANG BASKETS ON BASKET HANGERS OR FRYER VESSEL.
CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL.
NEVER LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WITHOUT DRAINING AS SEVERE INJURY MAY RESULT.
NOTE: For safety purposes, all Hi-Limit controls are
manually reset. Always check the Hi-Limit reset button before attempting to use the fryer. If the Hi-Limit has tripped, the fryer will not operate.
NOTE: For a fryer with a Central or Safe & Easy
®
Filter, always check the rear drain operating handle before attempting to use the fryer. A safety switch prevents the fryer from operating if the handle is not pushed in completely and locked into place.
A. BB Models
1. Fill fryer as described on page 4 - Filling.
2. Set Power switch to the “ON” position. “POWER
ON” light will be illuminated.
3. Set the Melt-Fry switch to “FRY.”
4. Set thermostat to the desired frying temperature
(between 325°F and 335°F).
5. When the oil reaches the desired frying
temperature, lower filled basket(s) slowly into the
hot oil.
6. When cooking cycle is complete, carefully lift
basket(s) out of oil. Place them on basket hanger
(on splashback of fryer) to allow draining of excess
oil.
6
B. TS Model
1. Fill fryer as described on page 4 - Filling.
2. Set Power switch to the “ON” position. “POWER ON” light will be illuminated.
3. Set the Melt-Fry switch to “FRY.”
4. Set thermostat to the desired frying temperature (between 325°F and 335°F).
5. When the oil reaches the desired frying temperature, the “READY TO COOK” light will illuminate.
6. Lower filled basket(s) slowly into the hot oil.
7. Set timer for left or right side basket, whichever is being lowered into oil. For programming instructions, see page 8.
8. When timer sounds, lift basket out of oil. Place on basket hanger (on splashback of fryer) to allow draining of excess oil.
C. Basket-Lift Models
1. Fill fryer as described on page 4 - Filling.
2. Set Power switch to the “ON” position. “POWER ON” light will be illuminated.
3. Set the Melt-Fry switch to “FRY.”
4. Set thermostat to the desired frying temperature (between 325°F and 335°F).
5. When the oil reaches the desired frying temperature, the “READY TO COOK” light will illuminate.
6. Fill basket(s) to proper level and place on upper bar of lift rod(s).
7. Set timer(s) to desired cooking time. For programming timers see page 8.
8. Push “T1,” “T2” or “T3” buttons on timer(s). Basket(s) will automatically lower into fryer vessel.
9. When cooking cycle is complete, an audible alarm will sound and the basket(s) will raise automatically. Allow oil to drain before removing baskets.
D. CPU Model
* See separate computer instructions or call
1-800-KEATING
SHUTDOWN
A. BB, TS and Basket-Lift Models
1. Turn fryer Power switch to “OFF” position.
B. CPU Model
1. Set Main Power On/Off switch to the “OFF” position.
DRAINING
ALWAYS SHUT THE FRYER OFF COMPLETELY BEFORE DRAINING. THE FRYER SHOULD BE DRAINED ONLY UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED TO ENSURE THE SAFETY OF THE OPERATOR.
1. Operator should be outfitted with proper attire including:
– Oil and heat resistant gloves – Oil and heat resistant apron – Safety goggles – Oil and heat resistant footwear
Figure 3-2
Operator in safety gear
2. Turn off the fryer and open the door.
3. For front drain fryers, put approved container under drain valve. For fryers with a central filter, slide filter drawer in completely.
4. For front drain fryers, slowly turn handle forward to avoid splashing. The drain valve will be completely open after 1/4 turn.
5. For units with rear drain valves, slowly pull drain valve operating handle straight out (unhook from metal latch first). See Safe & Easy operator’s manual for instructions on how to filter.
7
Figure 3-3
Front drain valve
Figure 3-4
Safe & Easy Filter
SIDE VIEW WITH FILTER IN BATTERY AND
SIDE VIEW WITH FILTER UNDER
UNDER NO CIRCUMSTANCES SHOULD YOU PERMIT HOT OIL TO COME IN CONTACT WITH WATER OR ICE. ALL DRAINING SHOULD BE DONE UNDER THE SUPERVISION OF PROPERLY TRAINED PERSONNEL. A DRAIN PIPE AND COVERED CONTAINER SUITABLE FOR USE WITH HOT OIL SHOULD BE USED WHENEVER A FRYER IS DRAINED. ALWAYS DRAIN OIL INTO A COVERED RECEPTACLE APPROVED FOR THE TRANSPORTATION OF HOT OIL.
CLEANING AND BOIL-OUT
When cleaning and boiling out your fryer use Keating Sea Powder and Keating Klenzer to keep your fryer in top condition. Keating Sea Powder dissolves any grease build up—even carbonized grease in fryer vessels—one of the leading causes of premature oil breakdown. And once your fryer vessel is clean, use Keating Klenzer, the finest dry stainless steel polish available, to restore your Keating Instant Recovery
®
Electric fryers’ exterior to its original luster.
To avoid damaging the fryer, do not power wash, spray or hose it down while cleaning.
Figure 3-5
Keating Klenzer and Sea Powder
1. Put on safety attire. See page 6 - Draining.
2. Turn the fryer off.
3. Drain oil from fryer, see page 6. Filtering may be done at this step.
4. Remove oil container to a secure area to prevent accidental spillage.
5. Fill fryer vessel to “Max Level” line with water.
UNDER NO CIRCUMSTANCES SHOULD THE FRYER BE LEFT UNATTENDED DURING BOIL-OUT. TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEATING ELEMENTS.
6. Set thermostat and turn fryer on to bring water to a gentle boil.
7. Once boil has been reached, turn fryer off.
8. Dissolve
2
/3 cup of Keating Sea Powder for every five
gallons of water and let soak for 1/
2 hour. If there is a
large build-up of carbonized grease, allow fryer to soak overnight.
Do not damage or remove thermostat bulb as this may affect the accuracy of the fryer.
9. While soaking, a natural fiber brush may be used to scrub the inside walls of fryer.
10. Drain the water and Sea Powder into a dry, suitable receptacle and remove from cooking area.
DRAIN VALVE
DRAIN VALVE
8
11. Spread Keating Klenzer liberally on sides of fryer vessel.
12. At this point, a non-abrasive scouring pad may be used to remove the now softened carbonized grease.
13. Thoroughly rinse fryer vessel with potable water to remove all Klenzer.
14. Prior to refilling with oil, wipe the inside of the fryer vessel making sure all water and Klenzer has been removed.
WATER IN ANY FORM AND HOT OIL DON’T MIX!!!
15. Close drain valve.
FAILURE TO CLOSE DRAIN VALVE BEFORE REFILLING THE FRYER MAY RESULT IN SERIOUS INJURY.
WHEN YOUR FRYER IS BEING USED IN CONJUNCTION WITH A CENTRAL FILTER, DISCONNECT POWER SUPPLY BEFORE RESETTING MOTOR TO PREVENT SERIOUS INJURY WHEN RESET SWITCH IS ENGAGED (SEE FILTER MANUAL).
16. Check thermostat bulb positioning - see page 9.
17. Refill the fryer with new or filtered oil.
NOTE: MSDS Sheets for Keating Klenzer, Sea
Powder & Acidox are available on-line at www.keatingofchicago.com.
ELECTRONIC CONTROL
TIMERS
The electronic timers provide a clearly visible and accurate display and are very easy to use.
ELECTRONIC TIMERS
Figure 3-6
A. PROGRAMMING
To program the timers, the unit must be in the idle mode. Press and hold the set button for approximately two seconds. The display will show “SEt”. Press T1, T2, or T3 for the cook time to be programmed. The display will show the current setting for that cook time. Use the up or down button to increment or decrement the setting. When the setting is correct, press and hold the set button again for approximately two seconds. The display will show "StO" for approximately two seconds and the timer will return to normal operation. Repeat the process as necessary for the other timers.
B. OPERATING LOGIC
When the timer is powered up, the display will show the time setting for the cook time that was operated last and the relay output contacts will be open. To start a cycle, press the desired cook time button (T1, T2, T3). The display will begin to countdown from the preset time setting and the relay output contacts will close. During the countdown the colon will flash at a one­second rate. When the countdown has reached "00:00" the relay output contacts will open, the display will flash, and the audible alarm will sound. To cancel the audible alarm, press any button.
C. PAUSE FEATURE
To pause a cycle in progress, press any button. The relay output contacts will open, the display will flash, and the countdown will pause. To resume the countdown, press any button. The display will resume the normal countdown and the relay output contacts will close.
D. CANCELING A CYCLE
To cancel a cycle in progress press and hold any button for approximately two seconds. The relay output contacts will open and the display will show the time setting for the cook time last used.
MAINTENANCE
WARRANTY REPAIRS
Keating’s warranty begins with the date of installation. In the event that your fryer, under warranty, needs repairs other than routine maintenance or cleaning, you are requested to contact Keating of Chicago (at 1-800-KEATING) before calling a local service company.
PREVENTIVE MAINTENANCE
Preventive maintenance should be done in daily, weekly, monthly and yearly intervals as necessary. Following preventive maintenance procedures will help keep your fryer working efficiently. Proper care and servicing will lead to years of quality performance.
PREVENTIVE MAINTENANCE CHART
* High production facilities should be checked more often.
A. Oil Breakdown
As part of a “Preventive Maintenance Program”, the oil in your fryer needs to be filtered regularly to avoid breakdown. The initial investment in the frying system is less than the total overall costs of oil during the life of the fryer, and with regular filtering, you can realize substantial savings in oil costs as well as maintenance charges.
B. Limited Calibration (less than 15°F off)
Thermostat Calibration
You will need: One standard flat blade screwdriver
One accurate fryer thermometer
1. Set thermostat to desired frying temperature.
2. Allow fryer to cycle three times.
3. Place an accurate thermometer in the oil.
4. If temperature of fryer is found to be more or less than 15°F off, remove the thermostat knob. There are (4) screws holding the dial plate in place. Loosen the screws and reset the dial plate to match the thermometer reading.
DO NOT ADJUST THE THERMOSTAT SET SCREW
- IT VOIDS ANY WARRANTY ON PART.
NOTE: Locate thermometer in same position for
every calibration. Position next to upper heating element is recommended.
C. Thermostat Bulb Positioning
Keating’s patented thermostat application is accurate within ±7°F of the dial setting between 250°F and 350°F. This accuracy is attained only if the thermostat bulb is placed properly against the top element using element clamps. If the bulb is too far away from the element, the fryer will overshoot.
Overshoot: The thermostat takes a long time to cycle and then misses its preset temperature by 20°F - 40°F yielding a poor quality product.
TIME
FRAME
OPERATOR/OWNER SECTION
At least daily
• Check that the oil is up to “Max Level” line.
• Clear all baskets.
• Drain, strain or filter oil.
OPERATION
At least weekly
• Drain and clean fryer.
• Boil-out fryer.
OPERATION
At least monthly
• Check lights and controls.
• Verify Thermostat settings.
• Test Hi-Limit control.
• Verify all thermostat settings.
• Verify wire connections.
MAINTENANCE
At least yearly
QUALIFIED SERVICE PERSONNEL ONLY:
• Calibrate thermostat.
MAINTENANCE
& SERVICE
DIAGNOSIS
9
10
SERVICE DIAGNOSIS
A properly adjusted Keating Instant Recovery®Electric Fryer, with no load, will cycle “on” approximately every 21/2 to 3 minutes. Each cycle will last 15-25 seconds, ensuring that the temperature setting is held within a narrow band.
Every Keating Instant Recovery
®
Electric Fryer has a number of safety controls to ensure safe operation and
guard against component failure.
A. Trouble shooting
The following diagnosis is only to be used as a guide to qualified service personnel. Keating recommends that you use a qualified service company. Call 1-800-KEATING if you need assistance in locating a qualified service company.
PROBLEM PROBABLE CAUSE SOLUTION
Fryer won’t heat. a. No electricity to fryer (“POWER ON”
switch is off).
b. No electricity to control circuit
(models with Basket-Lift or Central Filter).
c. Fryer circuit breakers have tripped.
d. Hi-Limit has been activated.
e. Rear drain valve handle has not been
fully closed (fryers with filter only).
f. On/Off Switch is faulty.
g. Melt-Fry switch is faulty.
h. Contactor is faulty.
i. Thermostat is faulty.
a. Connect fryer to an approved source
of power.
b. Connect 120V terminal block to an
approved source of power.
c. Reset circuit breakers.
d. Push in Hi-Limit Reset button
located behind fryer door. Check calibration of thermostat and operation of Hi-Limit and contactor.
e. Fully close and latch rear drain valve
handle. Turn fryer OFF and then ON to restart.
f. Replace On/Off Switch.
g. Replace Melt-Fry Switch.
h. Replace contactor.
i. Replace thermostat.
Fryer has poor recovery or runs cold.
a. Over-filling baskets.
b. Fryer vessel overfilled with oil.
c. Thermostat out of calibration.
d. Carbon coating on elements.
e. Element is faulty.
f. Thermostat is faulty.
g. Contactor is faulty.
h. Low incoming voltage.
a. Don’t overfill baskets.
b. Fill fryer up to “Max Level” line as oil
expands when heated.
c. Calibrate thermostat. See page 9 –
Calibration.
d. Boil-out fryer. See pages 7-8 –
Cleaning and Boil-Out.
e. Replace Element.
f. Replace thermostat.
g. Replace contactor.
h. Verify proper incoming voltage.
Fryer is overheating. a. Thermostat bulb improperly placed.
b. Thermostat out of calibration.
a. Adjust bulb position. See page 9 –
Thermostat Bulb Positioning.
b. Calibrate thermostat (See page 9 –
Calibration).
11
SERVICE DIAGNOSIS (continued)
PROBLEM PROBABLE CAUSE SOLUTION
Oil in fryer vessel smokes.
a. Oil has begun to break down.
b. High carbon content in oil.
c. Dirty fryer vessel.
d. Inferior grade of oil.
e. Fryer is overheating.
a. Replace oil.
b. Filter oil completely, replace if
necessary.
c. Boil-out fryer. See pages 7-8 –
Cleaning and Boil-Out.
d. Check with oil supplier for higher
grade of oil needed for your cooking applications.
e. Check calibration of thermostat (See
page 9 – Calibration) and replace if necessary. Check if Hi-Limit trips at 425°F. If not, replace Hi-Limit.
Oil in fryer vessel boils over.
a. Baskets are overfilled.
b. Fryer vessel overfilled with oil.
c. Oil is breaking down and foaming.
d. Water in cold zone.
a. Don’t overfill baskets.
b. Fill fryer up to “Max Level” line as oil
expands when heated.
c. Replace oil.
d. Stir oil with a paddle until water boils
off. Filter oil. If water remains, let oil cool and drain a quart of it.
Contactor chatters. a. Voltage is low to fryer.
b. Contactor coil faulty.
c. Connections are loose.
d. Thermostat contacts do not close
properly.
a. Contact your electrician or the local
power company and have the incoming power checked.
b. Replace contactor.
c. Tighten connections.
d. Replace thermostat.
TS MODELS:
PROBLEM PROBABLE CAUSE SOLUTION
Basket-Lift mechanism. a. Connections are loose or timer is
faulty.
b. Actuator is faulty
c. Control circuit breaker has tripped.
d. Relay is faulty.
a. Tighten connections. Replace timer
if it will not operate.
b. Replace actuator.
c. Reset circuit breaker.
d. Replace relay.
12
PARTS LIST
ORDERING PARTS
Parts may be ordered by part number by calling Keating at 1-800-KEATING or your service company. You may also order online at Keating’s Parts Store, www.keatingofchicago.com.
Refer to the Keating Instant Recovery
®
Electric Fryer Limited Warranty for complete service and ordering
information.
The model/serial plate is attached to the inside of the front door. The serial and model numbers are necessary when ordering.
NOTE: On Drop-In fryers, the model/serial plate is attached to the top of the control panel.
WARNING AND OPERATING PLATES
All warning and operating plates on the Keating Instant Recovery®Electric Fryer should be in place at all times. If plates are damaged or lost, replace them immediately.
ELECTRIC FRYER PARTS LIST
13
ITEM DESCRIPTION MODELS PART # 10×11 14 18 20 24 34×24
2 ELEMENT CLAMP ALL 004167 2 2 2 2 2 2 3 ELEMENT SPACER ALL 004145 4 4 4 FRYER VESSEL CALL 1-800-KEATING 1 1 1 1 1 1 5 DRAIN VALVE, FRONT, 1” BB, TS 004553 1 1
DRAIN VALVE, REAR, 1” BB, TS 016341 1 1 DRAIN VALVE, FRONT 1 1/4 BB, TS 004554 1 1 1 2 DRAIN VALVE, REAR, 1 1/
4
BB, TS 016342 1 1 1 2
DRAIN VALVE, FRONT, 2” OPTIONAL 019722 1 1 1 2
6 BASKET HANGER SEE BELOW 1 1 1 1
ITEM DESCRIPTION 10x11 14 18 20 24
6 BASKET HANGER 018553 018477 018556 018559 018562
ITEM DESCRIPTION MODELS
PART # (220V)
ELEMENT
PART # (440V)
ELEMENT
10×11 14 18 20 24 34×24
1 HEATING ELEMENT
2500 W BB 004347 3
BB 006342 3 3800 W TS 005623 004348 3 4350 W BB 004349 004350 3 6000 W BB 004353 004352 3 3
TS 004353 004352 4 4
BB 004355 022287 4 5
TS 004355 022287 5 6 6500 W TS 014493 019256 3 TEFLON RING BB, TS 004318 004318 2 PER ELEMENT 5/8” FLAT WASHER BB, TS 004319 004319 2 PER ELEMENT 5/8” - 16 BRASS LOCKNUT BB, TS 004323 004323 2 PER ELEMENT LCKWSHR, INT, #10 HI-TEMP BB, TS 011562 011562 4 PER ELEMENT RING TERM, #10 HI-TEMP BB, TS 011881 011881 2 PER ELEMENT FLAT WASHER, #10 HI-TEMP BB, TS 059502 059502 2 PER ELEMENT NUT 10-32 BB, TS 000361 000361 2 PER ELEMENT
Exploded view of heating element
wire connection hardware
Splashback
6
1
1
3
4
1
2
5
14
Figure 6-2 BB Control Panel 208/240V & 480V (Not shown to scale)
ITEM DESCRIPTION PART # 10×11 14 18 20 24 34×24
1 SWITCH TOGGLE SEALED ON-OFF 059141 1 1 1 1 1 1 2 INDICATING LIGHT CLEAR ROUND 28V 057863 1 1 1 1 1 1 3 SWITCH TOGGLE SEALED MELT-FRY 059143 1 1 1 1 1 1 4 THERMOSTAT KNOB, BLACK 060612 1 1 1 1 1 1 5 THERMOSTAT DIAL PLATE FRYER 250º-375º 058037 1 1 1 1 1 1 6 THERMOSTAT 031099 1 1 1 1 1 1 7 CONTACTOR 3 POLE 30 AMP 033896 2(208/480)
2(480v) 2(480v) 2(480v) 4(480v)
CONTACTOR 3 POLE 40 AMP 033898 2 CONTACTOR 3 POLE 50 AMP 033899 2 2 4 CONTACTOR 4 POLE 40 AMP 053383 2
(208/480)
8 TRANSFORMER STEP DOWN 056037 1 1 1 1 1 1 9 FAT MELT INFINITE CONTROL 037470 1 1 1 1 1 1 10 HIGH LIMIT RESETTABLE 060806 1 1 1 1 1 1 11 CIRCUIT BREAKER 16 AMP 1 POLE (208-240V) 057338 3
CIRCUIT BREAKER 32 AMP 1 POLE (208-240V) 033885 6 CIRCUIT BREAKER 40 AMP 1 POLE (208-240V) 033881 6 6 8 10 CIRCUIT BREAKER 10 AMP 1 POLE (480V) 057336 3 CIRCUIT BREAKER 16 AMP 1 POLE (480V) 057338 6
CIRCUIT BREAKER 20 AMP 1 POLE (480V) 033920 6 6 8 10 12 MAGNETIC REED SWITCH (Rear Drain Fryers Only) 053777 1 1 1 1 1 2 13 RELAY (Rear Drain Fryers Only) 030844 1 1 1 1 1 1
(Quantity Per Model)
CONTACTOR TRAY (Front View) - Front Drain Unit
CONTACTOR TRAY (Top View) - Front Drain Unit
5
6
11
10
8
7
4
3
2
1
CONTROL PANEL FRONT
12
139
15
Figure 6-3 TS Control Panel 208/240V & 480V with Rocker Switches (Not shown to scale)
ITEM DESCRIPTION PART # 10×11 14 18 20 24 34×24
1 SWITCH ROCKER ON-OFF DPST 035030 1 1 1 1 1 1 2 SWITCH ROCKER SPDT WHITE 025726 1 1 1 1 1 1 3 INDICATING LIGHT GREEN 28V 021255 1 1 1 1 1 1 4 INDICATING LIGHT RED 28V 021209 1 1 1 1 1 1 5 TIMER DIGITAL 24V/120VAC 056921 2 2 2 2 2 2 6 THERMOSTAT KNOB, BLACK 060612 1 1 1 1 1 1 7 THERMOSTAT DIAL PLATE FRYER 250º-375º 058037 1 1 1 1 1 1 8 THERMOSTAT 031099 1 1 1 1 1 1 9 FAT MELT INFINITE CONTROL 037470 1 1 1 1 1 1 10 CONTACTOR 3 POLE 30 AMP 033896 2(208/480v) 2(480v) 4(480v) 4(480v)
CONTACTOR 3 POLE 50 AMP 033899 2 4 4 CONTACTOR 4 POLE 30 AMP 053385 2
(480v)
2
(480v)
CONTACTOR 4 POLE 40 AMP 053383 2 2
11 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 1 1 1 1 1
12
HIGH LIMIT RESETTABLE 060806 1 1 1 1 1 1
13 CIRCUIT BREAKER 16 AMP 1 POLE (208-240V) 057338
CIRCUIT BREAKER 25 AMP 1 POLE (208-240V) 033525 3 CIRCUIT BREAKER 32 AMP 1 POLE (208-240V) 033885 CIRCUIT BREAKER 40 AMP 1 POLE (208-240V) 033881 6 8 8 10 CIRCUIT BREAKER 13 AMP 1 POLE (480V) 057337 3
CIRCUIT BREAKER 20 AMP 1 POLE (480V) 033920 6 8 8 10 12 14 RELAY 030844 1 1 2 2 1 1 15* MAGNETIC REED SWITCH 053777 1 1 1 1 1 2 16* CIRCUIT BREAKER BASKET LIFT 4AMP 1 POLE 058219 1 1 1 1
*Not Shown-Rear Drain Only
(Quantity Per Model)
CONTACTOR TRAY (Top View) - Front Drain Unit
7
8
1
2
3
4
5
5
6
13
12
14
9
10
11
CONTROL PANEL FRONT
CONTACTOR TRAY (Front View) - Front Drain Unit
16
Figure 6-4 TS Control Panel 208/240V & 480V with Toggle Switches (Not shown to scale)
ITEM DESCRIPTION PART # 10×11 14 18 20 24
1 SWITCH TOGGLE SEALED ON-OFF 059141 1 1 1 1 1 2 INDICATING LIGHT CLEAR ROUND 28V 057863 1 1 1 1 1 3 SWITCH TOGGLE SEALED MELT-FRY 059143 1 1 1 1 1 4 INDICATING LIGHT GREEN ROUND 056587 1 1 1 1 1 5 INDICATING LIGHT RED ROUND 057861 1 1 1 1 1 6 TIMER DIGITAL 24V/120V 056921 2 2 2 2 2 7 THERMOSTAT KNOB, BLACK 060612 1 1 1 1 1 8 THERMOSTAT DIAL PLATE FRYER 250º-375º 058037 1 1 1 1 1 9 THERMOSTAT 031099 1 1 1 1 1 10 FAT MELT INFINITE CONTROL 037470 1 1 1 1 1 11 CONTACTOR 3 POLE 30 AMP 033896 2
(208/480v)
2
(480v)
4
(480v)
CONTACTOR 3 POLE 50 AMP 033899 2 4 CONTACTOR 4 POLE 30 AMP 053385 2(480v) 2(480v) CONTACTOR 4 POLE 40 AMP 053383 2 2
12 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 1 1 1 1
13
HIGH LIMIT RESETTABLE 060806 1 1 1 1 1
14 CIRCUIT BREAKER 16 AMP 1 POLE (208-240V) 057338
CIRCUIT BREAKER 25 AMP 1 POLE (208-240V) 033525 3 CIRCUIT BREAKER 32 AMP 1 POLE (208-240V) 033885 CIRCUIT BREAKER 40 AMP 1 POLE (208-240V) 033881 6 8 8 10 CIRCUIT BREAKER 13 AMP 1 POLE (480V) 057337 3
CIRCUIT BREAKER 20 AMP 1 POLE (480V) 033920 6 8 8 10 15 RELAY 030844 1 1 2 2 1 16* MAGNETIC REED SWITCH 053777 1 1 1 1 1 17* CIRCUIT BREAKER BASKET LIFT 4AMP 1 POLE 058219 1 1 1 1
(Quantity Per Model)
14
1211
10
13
15
CONTROL PANEL FRONT
CONTACTOR TRAY (Top View) - Front Drain Unit CONTACTOR TRAY (Front View) - Front Drain Unit
*Not Shown-Rear Drain Only

POWERPOWER
OFF ON ON

READYFRYMELT
OVER MAX
TO COOK
TEMP.

17
Figure 6-5 34X24 TS Control Panel 208/240V & 480V with Toggle Switches (Not shown to scale)
ITEM DESCRIPTION PART # 34×24
1 SWITCH TOGGLE SEALED ON-OFF 059141 1 2 INDICATING LIGHT CLEAR ROUND 28V 057863 1 3 SWITCH TOGGLE SEALED MELT-FRY 059143 1 4 INDICATING LIGHT GREEN ROUND 056587 1 5 INDICATING LIGHT RED ROUND 057861 1 6 TIMER DIGITAL 24V/120V 056921 2 7 THERMOSTAT KNOB, BLACK 060612 1 8 THERMOSTAT DIAL PLATE FRYER 250º-375º 058037 1 9 THERMOSTAT 031099 1 10 FAT MELT INFINITE CONTROL 037470 1 11 CONTACTOR 3 POLE 30 AMP 033896 4(480v)
CONTACTOR 3 POLE 50 AMP 033899 4 CONTACTOR 4 POLE 30 AMP 053385
CONTACTOR 4 POLE 40 AMP 053383 12 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 13 HIGH LIMIT RESETTABLE 060806 1 14 CIRCUIT BREAKER 16 AMP 1 POLE (208-240V) 057338
CIRCUIT BREAKER 25 AMP 1 POLE (208-240V) 033525
CIRCUIT BREAKER 32 AMP 1 POLE (208-240V) 033885
CIRCUIT BREAKER 40 AMP 1 POLE (208-240V) 033881
CIRCUIT BREAKER 13 AMP 1 POLE (480V) 057337
CIRCUIT BREAKER 20 AMP 1 POLE (480V) 033920 12 15 RELAY 030844 1 16* MAGNETIC REED SWITCH 053777 2 17* CIRCUIT BREAKER BASKET LIFT 4AMP 1 POLE 058219
*Not Shown-Rear Drain Only
Detail Area
CONTACTOR TRAY (Top View) - Front Drain Unit
CONTACTOR TRAY (Front View) - Front Drain Unit
5
2
4
6
6
7
31
89
10
11
11
15
12
13
14
CONTROL PANEL FRONT
18
Figure 6-6 34X24 CPU Control Panel 208/240V with Toggle Switch (Not shown to scale)
ITEM DESCRIPTION PART # 34×24
1 SWITCH TOGGLE SEALED ON-OFF 059141 1 2 COMPUTER 031125 1 3 INDICATING LIGHT RED ROUND 057861 1 4 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 5 CIRCUIT BREAKER 40 AMP 1 POLE (208-240V) 033881 12 6 HIGH LIMIT RESETTABLE 060806 1 7 RELAY DPDT 24 VAC 030844 1 8 RELAY DPDT 24 VDC 017673 1 9 MAGNETIC REED SWITCH (REAR DRAIN FRYERS ONLY) 053777 2 10 COMPUTER PROBE 004776 1 11 CONTACTOR 50 AMP 3 POLE 033899 4
1
2
3
4
6
7
8
9
10
5
CONTACTOR TRAY (Top View) -
Rear Drain Unit
CONTACTOR TRAY (Front View) - Rear Drain Unit
11
CONTROL PANEL FRONT
6
9
19
Figure 6-7 CPU Control Panel 208/240V with Rocker Switches (Not shown to scale)
1
2
3
4, 5, 6, 7 8
ITEM DESCRIPTION PART # QTY
1 COMPUTER 031125 1 2 SWITCH ROCKER ILLUMINATED GREEN 032242 1 3 SWITCH ROCKER MOMENTARY 015384 1 4 SCREW CARRIAGE 10 - 24 x 1/2” 027490 4 5 WASHER INTERNAL TOOTH LOCK #10 011562 4 6 WASHER .190 I.D. X .563 O.D. 013217 4 7 NUT HEX #10 - 24 009053 4 8 SCREW PAN HEAD PHILLIPS 10 - 24 x 1/2” 030850 2 9 TRANSFORMER STEP DOWN 24VAC 80VA 024032 1 10 CIRCUIT BREAKER 3 AMP 1 POLE (250V) 053338 1 11 HIGH LIMIT MANUAL RESET 060806 1 12 RELAY DPDT 24VAC 030844 2 13 RELAY DPDT 24VDC 017673 2 14 COMPUTER PROBE 004776 1 15 TRANSFORMER STEP DOWN 24VAC 75VA 056037 1 16 CIRCUIT BREAKER 40 AMP 1 POLE (208-240V) 033881 6 17 CONTACTOR 50 AMP 1 POLE 033899 2 18** SPARK IGNITION MODULE 24VAC 058439 1 19** BRACKET SPARK IGNITION MODULE 056000 1 20 MAGNETIC REED SWITCH (REAR DRAIN FRYERS ONLY) 053777 1
**Spark Ignition Model Only
9
10
11
13
SPARK IGNITION
CONTACTOR TRAY (Front View) -
Rear Drain Unit
14
SPARK IGNITION
CONTACTOR TRAY (Top View)
19
12
18
15
16
17
11
12
13
14
20
CONTACTOR TRAY (Front View) - Rear Drain Unit
CONTACTOR TRAY (Top View)
20
20
DESCRIPTION QTY PART #
1 TRANSFORMER 120/208/240/480V 1 056036 2* CIRCUIT BREAKER 3A/250V 1 053338 3 RELAY DPDT 24V AC 2 030844 4 RECTIFIER 1 018321 5 POWER CORD 1 021289 6 CONNECTION 3 CIRCUITS PLUG 1 032210
CONNECTOR CONTACT PIN MALE 3 028309
7 CONNECTOR 2 CIRCUIT CAP 2 032207
CONNECTOR CONTACT PIN FEMALE 2 028308 8 COVER FOR CIRCUIT BREAKER 1 054664 9 PUSH ROD 1 018096 10 SCREW
1
/4"-20" X 11/4" 1 021091
HEX NUT1/4-20 1 016383 11 COUPLER ACTUATOR BL 1 054525
RETAINING RING 2 054540
PIN COUPLER ACTUATOR BL 2 054503 12 ACTUATOR 24V DC 1 054510 13 SHAFT ACTUATOR LOWER BL S/S 1 054522 14 CONNECTOR 2 CIRCUIT PLUG 1 032208
CONNECTOR CONTACT PIN MALE 2 028309 15 PIN BASKET LIFT NON ROTATIONAL 1 054760
*This circuit breaker can be found under the control panel on newer units.
6
5
1
2
4
3
8
7
10
9
15
11
14
12
13
NOTES
1. A minimum distance of 3/
16" and maximum distance of
1
/
4" should be maintained when actuator
is at full downward stroke. Item 11 should never be bottomed on item 12 when in this location.
2. Actuator shaft should travel 6
1
/2" upward from lowest position.
3. Distance are to be measured when actuator is powered.
4. Apply light coating of food grade grease to Item 9 on entire shaft inside housing.
Housing
Figure 6-8 Basket Lift Power Supply Box Figure 6-9 Basket Lift Assembly
21
DESCRIPTION QTY PART #
1 TRANSFORMER STEPDOWN 24VAC 100VA 1 058359 2 RELAY DPDT 24VAC 2 030844
RELAY DPDT 24VDC (CPU MODEL) 2 017673 3 RECTIFIER 24VDC 1 018321 4 BUSHING STRAIN RELIEF
5
/8” HOLE 2 000470
5 BUSHING STRAIN RELIEF 3/4” HOLE 1 033800
*Circuit breaker is located under the control panel.
Basket Lift Power Supply Box 2007 (CPU & Non-CPU)
4700Y08K18K999
PRI:
COM 120 208 240 480
BLK WHT RED ORG BLK/RED
SEC:
24 VAC
BLU YEL
100 VA 50/60HZ
PRODUCTS UNLIMITED
ASM. IN MEXICO
tyco
Electronis
RU
C
US
1
2
3
4
5
4
TOP VIEW
SIDE VIEW
TO LEFT BASKET
TO CONTROL PANEL BACK/TRAY
TO RIGHT BASKET
22
WIRING DIAGRAMS
NOTE: A separate wiring diagram has been included with this manual and should be saved for troubleshooting and
maintaining the fryer. The wiring diagrams in this section cover standard fryers which may or may not match the diagram sent with the fryer. CPU models on pages 34 & 35.
SINGLE BASKET LIFT POWER SUPPLY BOX
DESCRIPTION QTY PART #
1 AR WIRENUT GRAY 2 027134 2 AP CONNECTOR 6 CIRCUIT PLUG 1 028302 3 CONNECTOR CONTACT PIN MALE 5 028309
23
10×11 BB 2006 208-240V & 480V 3 PHASE FRONT DRAIN
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
10×11, 14, 18 & 20 BB 2000 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY® FILTER
BASKET LIFT
66 BR 67 BL
70
5
7
R
8
6
68
BL
LEFT BASKET
24VAC HOT
RIGHT BASKET
C
2211BL
WH
31
NO NC
42
REAR DRAIN
C
MAGNETIC
BL
RDS
REED SWITCH
NC
12
69
CNC
HL
BR
1 2 3
64BR63YL42
4443 4645
BR
213
5476
RD
BR50BU
52
51TH53OR54YL55RD56
59
BL
MIFMP
58
TS
NEUT
LOAD HOT
12
3
4847 49
65
YLORRDBU
BL WHRD
OR
11
9810
12
119108765432112
WH
BL
57
60
RD
HLT
H
WH
61
BL
WH41
OR62
CONTROL PANEL TRAY
CONTROL PANEL INSERT
HEATING ELEMENTS
36
BL
L1
CR
T1
BL
25
1
2CB4
1
BL BL
TO BASKET LIFT
A1
BL
L2
T2
BL
3
4
12915
WH
WH
L1
L3
A2 A2
CR
A2
T1
T3
40 WH
WH
WH
118
5143
CB
26
10
7
WH
WH
POWER SUPPLY BOX
#4 - BLACK COM #1 - WHITE 120V
NOTCH
WH
39
BR
GND
TRANSFORMER CONNECTIONS
TR
24VAC
BU
FRONT COVER
18
RD
RD
L2
L3
A1
A2
T2
T3
RD
RD
14
17
5
6
16
13
RD
RD
TB
#5 - RED 208V #6 - GRAY 480V
#2 - ORANGE 240V
WH OR
RDBL GY
33112
44665
2
5
TRANSFORMER CONNECTIONS
WH37RD
WIRE COLOR CODES: RD - RED
RP
BL - BLACK BR - BROWN BU - BLUE GR - GREEN OR - ORANGE WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC GND - GROUNDING LUG H - "HEAT" ON LIGHT
120
HL - HIGH LIMIT SWITCH
VAC
HLT - "HIGH LIMIT TEST" SWITCH MIF - "MELT-IDLE-FRY" SWITCH MP - "MAIN POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RP - RECEPTACLE WITH POWER CORD (APPLIES ONLY TO UNITS WITH FILTER) TB - TERMINAL BLOCK TH - THERMOSTAT TR - TRANSFORMER TS - FAT MELT TIMER RELAY SWITCH
SEE
38
HEATING ELEMENTS
#4 - BLACK COM #5 - RED 208V #6 - GRAY 480V
#2 - ORANGE 240V #1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: RD - RED
BL - BLACK BR - BROWN BU - BLUE GR - GREEN OR - ORANGE WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF- "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #6 ARE 10 AWG,
WIRES #7 TO #15 ARE 12 AWG.
2. ALL OTHER WIRES ARE 18 AWG.
10 11 12
20
26 RD
24 OR
BL BL
WH
FM
HOT21LOAD3NEUT
1C2
4
NCNO
HL
BL BL
25
27 28
TRAY
2221 23
BL
WHOR RD
BUBR
312 456789
BL OR BURD WH
3456
2BR1
F
976548321
M
BL1BL
CONTROL
PANEL
CONTROL
PANEL
INSERT
TH
8YL
PPOMF
7BR
WH
L1T3L2 L3NCNC
789
A2
A2
T2A1T1
WH
1
21212
CB
23
WH
POWER CONNECTION BOX
13
WH
WH
19
L1T3L2 L3
456
WH
DB
14 15
RD
CR2CR1
T2A1T1
RD
GRD
RD
FM
SEE
TRANSFORMER
6
GY
CONNECTION
CHART
565
RD
44
BL
NC
A2
A2
NC
WH 18
OR
WH
75VA
TR
24VAC
BR
BU
22
11
1716
33
BL WH
RD
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
24
10×11 BB 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
10×11 BB 2006 208-240V & 480V 1 PHASE FRONT DRAIN
HEATING ELEMENTS
#4 - BLACK COM #5 - RED 208V #6 - GRAY 480V
#2 - ORANGE 240V #1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: RD - RED
BL - BLACK BR - BROWN BU - BLUE GR - GREEN OR - ORANGE WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF- "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #6 ARE 10 AWG,
WIRES #7 TO #15 ARE 12 AWG.
2. ALL OTHER WIRES ARE 18 AWG.
4
NCNO
CONTROL
PANEL
TRAY
CONTROL
PANEL
INSERT
1C2
HL
2221 23
BL
BL OR BURD WH
2BR1
PPOMF
7BR
FM
HOT21LOAD3NEUT
20
26 RD
24 OR
25
27 28
WHOR RD
BUBR
312 456789
3456
TH
8YL
WH
F
976548321
M
10 11 12
BL BL
BL
L1T3L2 L3NCNC
789
BL BL
21212
BL1BL
A2
A2
T2A1T1
BL
1
CB
23
BL
POWER CONNECTION BOX
13
RD
WH
19
L1T3L2 L3
456
RD
DB
14 15
RD
CR2CR1
T2A1T1
RD
GRD
RD
FM
SEE
TRANSFORMER
6
GY
CONNECTION
CHART
565
RD
44
BL
NC
A2
A2
NC
WH 18
RD
OR
WH
75VA
TR
24VAC
BR
BU
22
11
1716
33
BL RD
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
RDS
BLBLRDBR31
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK
BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF- "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #6 ARE 10 AWG,
11
22
WIRES #7 TO #15 ARE 12 AWG.
2. ALL OTHER WIRES ARE 18 AWG.
FM
HOT21LOAD3NEUT
29 WH
3
5
1
1C2
FM
R
87
30
32 RD
4
C
NO6NC
NCNO
4
2
HL
33 BR
25
27 28
TRAY
2221 23
BL
BL OR BURD WH
WHOR RD
BUBR
312 456789
3456
2BR1
CONTROL
PAN EL
CONTROL
PAN EL INSERT
TH
8YL
PPOMF
7BR
20
26 RD
24 OR
WH
F
976548321
M
10 11 12
BL BL
WH
L1T3L2 L3NCNC
789
BL BL
21212
BL1BL
A2
A2
T2A1T1
WH
1
CB
23
WH
POWER CONNECTION BOX
WH
14 15
13
WH
RD
19
L1T3L2 L3
T2A1T1
456
RD
WH
DB
RD
FM
SEE
TRANSFORMER
6
GY
CONNECTION
CHART
565
RD
44
BL
NC
A2
CR2CR1
A2
NC
WH 18
RD
OR
WH
75VA
TR
24VAC
BR
BU
22
11
1716
33
BL WH
GRD
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
25
14, 18, 20 BB 2006 208-240V & 480V 1 PHASE FRONT DRAIN
14, 18, 20 BB 2006 208-240V & 480V 3 PHASE FRONT DRAIN
HEATING ELEMENTS
13 14 15
BL BL
BL
L1T3L2 L3NCNC
T2A1T1
789
BL BL RD
21212
23
BL1BL
WH
A2
A2
BL
1
CB
BL
POWER CONNECTION BOX
WIRE COLOR CODES:
BL - BLACK
BR - BROWN
BU - BLUE
GR - GREEN
OR - ORANGE
RD - RED
WH - WHITE
YL - YELLOW
COMPONENT CODES:
CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC
DB - POWER DISTRUBITION BLOCK
FM - FAT MELT TIMER SWITCH
GRD - GROUNDING LUG
HL - HIGH LIMIT SWITCH
MF- "MELT FRY" SWITCH
P - "POWER" SWITCH
PO - "POWER ON" LIGHT (CLEAR)
TH - THERMOSTAT
TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #18 ARE 10 AWG.
2. ALL OTHER WIRES ARE 18 AWG.
4
CONTROL
PAN EL
TRAY
CONTROL
PAN EL
INSERT
1C2
NCNO
HL
2524 26
BL
BL OR BURD WH
PPOMF
7BR
FM
HOT21LOAD3NEUT
28
30 31
WHOR RD
BUBR
312 456789
3456
2BR1
TH
8YL
23
29 RD
27 OR
WH
F
M
976548321
17 18
16
RD
10 112212
RD
RD
RD
RD
L1T3L2 L3
CR2CR1
T2A1T1
RD
1121
22
456
RD
RD
DB
GRD
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER CONNECTION
CHART
FM
SEE
TRANSFORMER
GY
6
CONNECTION
CHART
RD
565
BL
44
2019
33
BL RD
OR
NC
A2
A2
NC
WH 21
22
WH
11
75VA
TR
24VAC
BR
BU
CB
26
14, 18, 20 BB 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY®FILTER
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
T T
24 BB 2006 208-240V & 480V 3 PHASE FRONT DRAIN
HEATING ELEMENTS
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: RD - RED
BL - BLACK BR - BROWN BU - BLUE GR - GREEN OR - ORANGE WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF- "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
2. WIRES #1 TO #6 ARE 10 AWG, WIRES #7 TO #18
3. ALL OTHER WIRES ARE 18 AWG.
FM
11
BL
BL
22
RDBR34
33
ONLY TO UNITS WITH FILTER.
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
C78NO65NC
R
35 RD
13 14 15
WH RD
FM
HOT21LOAD3NEUT
32 WH
4
1
43
C2NCNO
21
HL
36 BR
28
30 31
CONTROL
PAN EL
CONTROL
PAN EL
INSERT
2524 26
BL
WHOR RD
TRAY
BUBR
312 456789
BL OR BURD WH
3456
2BR1
BL BL
23
WH
29 RD
27 OR
L1T3L2 L3NCNC
T2A1T1
789
WH RD
BL BL WH RD
976548321
F
M
BL1BL2WH
1
21212
3
TH
8YL
PPOMF
7BR
POWER CONNECTION BOX
16
WH
WH
L1T3L2 L3
A2
A2
10 112212
CB
1121
22
456
WH RD
DB
17 18
CR2CR1
T2A1T1
GRD
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
24VAC
BR
BU
FILTER
RECEPTACLE
FRONT COVER
NOTCH
TRANSFORMER CONNECTION
CHART
GY
RD
565
BL
44
OR
22
WH
11
75VA
TR
WH
BL
GR
GRWH BL
115/120 VAC
60 HZ.
FM
6
33
SEE
TRANSFORMER
CONNECTION
CHART
2019
BL RD
RD
NC
A2
A2
NC
WH 21
CB
RD
HEATING ELEMENTS
17 18 19
BL BL
BL WH
29
WH
35 RD
33 OR
L1T3L2 L3
CR1
T2A1T1
910 11
BL WH
BL BL WH RD
976548321
F
M
21212
BL1BL2BL
1
3
#4 - BLACK COM #5 - RED 208V #6 - GRAY 480V
#2 - ORANGE 240V #1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES:
RD - RED
BL - BLACK
BR - BROWN
BU - BLUE
GR - GREEN
OR - ORANGE
WH - WHITE
YL - YELLOW
COMPONENT CODES:
CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC
DB - POWER DISTRUBITION BLOCK
FM - FAT MELT TIMER SWITCH
GRD - GROUNDING LUG
HL - HIGH LIMIT SWITCH
MF- "MELT FRY" SWITCH
P - "POWER" SWITCH
PO - "POWER ON" LIGHT (CLEAR)
H - THERMOSTAT R - TRANSFORMER
NOTES: 1. WIRES #1 TO #8 ARE 10 AWG, WIRES #9 TO #24
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
2. ALL OTHER WIRES ARE 18 AWG.
FM
HOT21LOAD3NEUT
1C2
4
NCNO
HL
34
36 37
CONTROL
PANEL
CONTROL
PANEL
INSERT
3130 32
BL
WHOR RD
TRAY
BUBR
312 456789
BL OR BURD WH
3456
2BR1
TH
8YL
PPOMF
7BR
20
WH RD
L4
A2
A2
T4
12
1
2
4
WH
21
WH
WH
L1T3L2 L3T4L4
13 142815
1121
CB
22
567
WH WH
22 23
CR2
T2A1T1
DB
POWER CONNECTION BOX
SEE
FM
TRANSFORMER
6
GY
CONNECTION
CHART
565
24
RD
A2
A2
27 WH
16
RDWH
1
CB
2
8
RD
RD
RD
44
BL
25
26
33
BL
RD
22
OR
11
WH
75VA
TR
24VAC
BR
BU
GRD
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
T T
34×24 BB 2006 208-240V & 480V 3 PHASE FRONT DRAIN
27
24 BB 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY®FILTER
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK
BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF- "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
2. WIRES #1 TO #8 ARE 10 AWG, WIRES #9 TO #24
3. ALL OTHER WIRES ARE 18 AWG.
FM
11
BL
RDBR40
22
BL
39
ONLY TO UNITS WITH FILTER.
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
C78NO65NC
R
41 RD
38 WH
1C2
4
NCNO
43
21
HL
42 BR
CONTROL
PAN EL
TRAY
CONTROL
PAN EL
INSERT
FM
HOT21LOAD3NEUT
34
36 37
3130 32
BL
WHOR RD
BUBR
312 456789
BL OR BURD WH
3456
2BR1
TH
8YL
PPOMF
7BR
17 18 19
BL WH
BL BL
29
WH
35 RD
33 OR
L1T3L2 L3
91011
BL BL WH RD
F
976548321
M
21212
BL1BL2BL
A2
CR1
A2
T2A1T1
BL WH
1
3
20
21
WH RD
WH
WH
L4
L1T3L2 L3T4L4
T4
12
13 142815
1
CB
2
4
WH
WH WH
POWER CONNECTION BOX
22 23
RD
A2
CR2
A2
T2A1T1
1121
22
567
RD
DB
GRD
SEE
FM
TRANSFORMER
GY
6
CONNECTION
CHART
RD
565
44
24VAC
BR
BL
OR
WH
75VA
TR
BU
FILTER
RECEPTACLE
FRONT COVER
22
11
GRWH BL
33
WH
BL
GR
115/120 VAC
60 HZ.
25
26
BL
RD
24
27 WH
16
RDWH
1
CB
2
8
RD
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR)
H - THERMOSTAT R - TRANSFORMER
NOTES: 1. WIRES #1 TO #10 ARE 10 AWG, WIRES #11 TO #30
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
2. ALL OTHER WIRES ARE 18 AWG.
1
4
C2NCNO
HL
CONTROL
PANE L
TRAY
CONTROL
PANE L
INSERT
FM
HOT21LOAD3NEUT
43
46 47
3938 40
BL
WHOR RD
BUBR
312 456789
BL OR BURD WH
3456
2BR1
TH
8YL
PPOMF
7BR
21 22 23 24 30
BL WH
BL BL
37
WH
44 RD
41 OR
11
BL BL
F
976548321
M
BL1BL2BL
42 OR
36
L2 L3 NC
A2
CR
1
A2
T2A1T1L1T3
NC NC
13
12
21212122
14 15
BL
WH
11
CB
3
45 7
WH
25 26 27
WH
WH
L2 L3
NC NC
A2
CR
2
A2
T2A1T1L1T3
35 WH
WH
CB CB
WH
28
WH RD RD RD
WH
L2 L3
A2
CR
3
A2
T2A1T1L1T3
17
16
18
RD
WH
1
1
1
2
2
2
8
6
RD
WHWHWH
DB
GRD
45 RD
34 WH
NC NC
CB
POWER CONNECTION BOX
SEE
TRANSFORMER
CONNECTION
29
F
M
L2 L3
NC
A2
CR
4
A2
T2A1T1L1T3
33 WH
19
20
RD
RD
1
1
2
2
9
10
RD
RD
32
CHART
123456
RD
31 BL
OR
BL
RD GYWH
75VA
TR
24VAC
BR
BU
654321
28
34×24 BB 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY®FILTER
A1 B4
A3
A2 B5
B6
A1
A3
A2
B4B5B6
T T
10×11 TS 2006 208-240V & 480V 3 PHASE FRONT DRAIN
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
LEFT
RDS
MAGNETIC
REED SWITCH
N.C.
REAR DRAIN
RIGHT
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH
H - THERMOSTAT R - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
2. WIRES #1 TO #10 ARE 10 AWG, WIRES #11 TO #30
3. ALL OTHER WIRES ARE 18 AWG.
FM
11
BL
BL
BL
BL
ONLY TO UNITS WITH FILTER.
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
22
11
22
RDBR52
BR50RD
51
FM
49
C
R
87
53 RD
FM
HOT21LOAD3NEUT
46 47
BUBR
37
44 RD
41 OR
WHOR RD
976548321
48 WH
3
5
1
1
4
NO6NC
C2NCNO
4
2
HL
54 BR
43
PANE L
TRAY
PANE L
INSERT
3938 40
BL
312 456789
BL OR BURD WH
3456
2BR1
CONTROL
CONTROL
TH
8YL
PPOMF
7BR
HEATING ELEMENTS
21 22 23 24 30
BL WH
BL BL
WH
L2 L3 NC
CR
1
T2A1T1L1T3
13
12
11
BL BL
21212
BL1BL2BL
BL
3
F
M
25 26 27
WH
42 OR
36
L2 L3
A2
A2
T2A1T1L1T3
NC NC
14 15
WH
WH
1
11
CB
22
45 7
WH
WH
WH RD RD RD
WH
WH
NC NC
L2 L3
A2
CR
2
A2
T2A1T1L1T3
35 WH
17
16
WH
1
CB CB
2
6
WHWHWH
DB
POWER CONNECTION BOX
28
45 RD
A2
CR
3
A2
18
RD
1
1
CB
2
2
8
RD
GRD
29
34 WH
L2 L3
A2
CR
4
A2
T2A1T1L1T3
NC NC
33 WH
19
20
RD
RD
1
1
2
2
9
10
RD
RD
FRONT COVER
SEE
TRANSFORMER
CONNECTION
CHART
F
M
123456
OR
75VA
NC
24VAC
BR
GRWH BL
FILTER
RECEPTACLE
115/120 VAC
32
RD
31 BL
654321
BL
RD GYWH
TR
BU
WH
BL
GR
60 HZ.
14 TS 2006 208-240V & 480V 3 PHASE FRONT DRAIN
29
10×11 TS 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN
T T
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
FM
11
BLBLRDBR36
22
34 WH
R-1
87
25 OR
3
5
1
4
C
NO6NC
R-2
87
35
4
37 RD
1
C2NCNO
2
HL
38 BR
21WH
3
5
1
FM
NO6NC
HOT21LOAD3NEUT
4
2
20
29 RD
26 OR
WH
10 11 12
BL BL
L1T3L2 L3T4L4
T2A1T1
C
WH RD
19
WH
A2
CR1
A2
14 15
13
WH
L1T3L2 L3
CR2
T2A1T1
SEE
TRANSFORMER
CONNECTION
F
M
RD
L4
A2
A2
T4
18 WH
17
CHART
123456
WH
16 BL
OR
BL RD GYWH
75VA
TR
24VAC
BR
BU
654321
BURD
BU YL WH
RD
8
3130
YLOR YL
32
OR
WHBR
F
11 1298765432110
M
ORYL
107911
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J2
J3
OUT
J1
J4
18 OR
13 WH
WH1415 WH
WIRE COLOR CODES: BL - BLACK
BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN)
H - THERMOSTAT R - TRANSFORMER
NOTES: 1. WIRES #1 TO #6 ARE 10 AWG.
WIRES #7 TO #15 ARE 12 AWG.
2. ALL OTHER WIRES ARE 18 AWG.
CONTROL PANEL TRAY
CONTROL PANEL INSERT
POWER INPUT
J2
J3
OUT
J1
J4
OR17
24 33
27 28
22 23
BL
123 84567 9101112
BLBR OR
RD
3456
2BR1
TH
19
YL
P MF RTC OMT
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #6 ARE 10 AWG, WIRES #7 TO #18
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
2. ALL OTHER WIRES ARE 18 AWG.
1
4
C2NCNO
HL
123 84567 9101112
RD
2BR1
POWER INPUT
J2
J3
OUT
J1
J4
OR17
19
P MF RTC OMT
28 OR
27 36
25 26
BL
BLBR OR
3456
TH
YL
R
87
30 31
5
C
NO6NC
BURD
BU YL WH
RD
8
3
1
4
2
3433
YLOR YL
24WH
FM
HOT21LOAD3NEUT
35
CONTROL
OR
WHBR
PANE L TRAY
F
11 1298765432110
M
CONTROL
ORYL
PANEL
107911
INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J3
J1
18 OR
13 WH
WH1415 WH
789
BL BL
WH
1
21212
BL1BL2WH
3
POWER CONNECTION BOX
HEATING ELEMENTS
13 14 15
WH RD
BL BL
23
WH
32 RD
29 OR
L1T3L2 L3T4L4
CR1
T2A1T1
789
WH RD
BL BL WH RD
1
21212
BL1BL2WH
3
J2
OUT
J4
POWER CONNECTION BOX
CB
22
A2
A2
CB
456
WH RD
RD
DB
GRD
17 18
16
WH
RD
L1T3L2 L3
CR2
T2A1T1
10 11WH12
1121
22
456
WH RD
RD
DB
GRD
L4
A2
A2
T4
CB
SEE
TRANSFORMER
CONNECTION
CHART
F
M
123456
OR
75VA
24VAC
BR
21 WH
20
RD
19 BL
654321
BL
RD GYWH
TR
BU
30
14 TS 2006 WITH BASKET-LIFT 208-240V & 480V 3 PHASE FRONT DRAIN
OR 44
WH 43
BU 45
BL 42
YL 46
BR 47
RD 48
GR 49
OR
WH
BU
BL
YL
BR
RD
GR
FM
33
22
11
44
55
66
77
88
99
14 TS 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY®FILTER
HEATING ELEMENTS
WIRE COLOR CODES: BL - BLACK BR - BROWN B/R - BLACK/RED BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
BASKET LIFT
POWER SUPPLY BOX
RIGHT
BASKET
LIFT
BL11
BRBU
C
NO
NC
2211MF
16 14
BU
15
BR
BR
BU
BR
17
BRBU
18
20
BU
OR WHBU BLYL BRRD GR
-
S
10
+
S
BL
WH13
12
YL9
WH
C
NO
NC
19
BU
BR
21
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
480V
B/R
240V
OR
208V
RD
120V
WH
COM
BL
24V
YL
24V
BU
BASKET
24WH
3
5
1
FM
NO6NC
4
2
3433
35
YLOR YL
BURD
WHBR
OR
11 1298765432110
BU YL WH
ORYL
107911
8
WH1415 WH
18 OR
HOT21LOAD3NEUT
RIGHT TIMERLEFT TIMER
F
M
CONTROL PANEL INSERT
12 WH16 WH
J3
J1
POWER INPUT
C
R
87
28 OR
4
1
C2NCNO
HL
27 36
30 31
25 26
4748
BL
CB 4A
LEFT
LIFT
POWER INPUT
J2
J3
OUT
J1
J4
OR17
BRBU
2211MF
BRBU
BRRD
123 84567 9101112
BLBR OR
RD
2BR1
19
3456
TH
YL
RD
P MF RTC OMT
CONTROL PANEL TRAY
13 WH
23
WH
32 RD
29 OR
J2
OUT
J4
13 14
15
BL BL
WH RD
L2 L3T4L4
A2
CR
1
A2
T2A1T1L1T3
89
7
BL BL WH RD
1
CB
21212
23
BL1BL
WH
POWER CONNECTION BOX
17
18
16
RD
WH
22 WH
L2 L3T4L4
CR
2
T2A1T1L1T3
10 11 12
RDWH
22112
4
WH56RD
RD
DB
SEE
TRANSFORMER
CONNECTION
CHART
FM
WH
1
1
OR
2
2
3
3
BL
4
A2
A2
21
WH
1
CB
4
RD
5
5
GY
6
6
75VA
TR
24VAC
BR
BU
2019
BL RD
GRD
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
ONLY TO UNITS WITH FILTER.
2. WIRES #1 TO #6 ARE 10 AWG, WIRES #7 TO #18 ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
3. ALL OTHER WIRES ARE 18 AWG.
4. THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX.
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
ONLY TO UNITS WITH FILTER.
2. WIRES #1 TO #6 ARE 10 AWG, WIRES #7 TO #18 ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
3. ALL OTHER WIRES ARE 18 AWG.
FM
11
BLBLRDBR39
22
37 WH
R-1
87
28 OR
3
5
1
4
C
NO6NC
R-2
87
40 RD
POWER INPUT
J3
J1
4
J2
OUT
J4
OR17
38
1
C2NCNO
2
HL
41 BR
27 36
30 31
25 26
BL
123 84567 9101112
BLBR OR
RD
3456
2BR1
TH
19
YL
P MF RTC OMT
3
5
C
NO6NC
4
BURD
BU YL WH
RD
8
1
2
3433
YLOR YL
24WH
FM
HOT21LOAD3NEUT
23
32 RD
29 OR
35
CONTROL
WHBR
OR
PANEL TRAY
11 1298765432110
F
M
CONTROL
ORYL
PANEL
107911
INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J2
J3
OUT
J1
J4
18 OR
13 WH
WH1415 WH
13 14 15
WH RD
BL BL
WH
L1T3L2 L3T4L4
CR1
T2A1T1
789
WH RD
BL BL WH RD
1
21212
3
BL1BL2WH
POWER CONNECTION BOX
22
A2
A2
CB
17 18
16
WH
RD
L1T3L2 L3
CR2
T2A1T1
10 11WH12
1121
22
456
WH RD
RD
DB
GRD
L4
A2
A2
T4
CB
SEE
TRANSFORMER
CONNECTION
CHART
F
M
123456
OR
24VAC
BR
21 WH
GRWH BL
FILTER
RECEPTACLE
FRONT COVER
BL RD GYWH
75VA
TR
BU
WH
BL
GR
115/120 VAC
20
19 BL
RD
654321
60 HZ.
18, 20 TS 2006 208-240V & 480V 3 PHASE FRONT DRAIN
31
14 TS 2006 WITH BASKET-LIFT 208-240V & 480V 3 PHASE WITH REAR DRAIN AND
SAFE & EASY
®
FILTER
WIRE COLOR CODES: BL - BLACK
BR - BROWN B/R - BLACK/RED BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
POWER SUPPLY BOX
RIGHT
BASKET
LIFT
BRBU
2211MF
16 14
BR
BU
BRBU
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
2. WIRES #1 TO #6 ARE 10 AWG, WIRES #7 TO #18
3. ALL OTHER WIRES ARE 18 AWG.
4. THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE
#4 - BLACK COM
#5 - RED 208V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
REED SWITCH
BASKET LIFT
OR WHBU BLYL BRRD GR
-
S
10
+
S
BL
WH13
BL11
C
NO
NC
BU
15
BR
17
ONLY TO UNITS WITH FILTER.
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX.
12
YL9
WH
C
NO
NC
18
20
19
BU
BR
BU
BR
21
#6 - GRAY 480V
RDS
MAGNETIC
N.C.
480V
B/R
240V
OR
208V
RD
120V
WH
COM
BL
24V
YL
24V
BU
FM
BLBLRDBR39
11
22
FM
11
BL 42
BL
22
WH 43
WH
33
OR 44
OR
44
BU 45
BU
55
YL 46
YL
66
BR 47
BR
77
RD 48
RD
88
GR 49
GR
99
LEFT
BASKET
LIFT
BRBU
2211MF
BRBU
HEATING ELEMENTS
37 WH
R-1
28 OR
3
5
1
4
C
NO6NC
R-2
87
38
40 RD
CB 4A
POWER INPUT
J2
J3
OUT
J1
J4
OR17
1
C2NCNO
4
2
HL
41 BR
25 26
4748
BL
BRRD
123 84567 9101112
BLBR OR
RD
3456
2BR1
TH
19
YL
27 36
30 31
PMFRTCOMT
87
5
C
NO6NC
BURD
BU YL WH
RD
8
3
1
4
2
3433
YLOR YL
24WH
FM
HOT21LOAD3NEUT
23
32 RD
29 OR
35
CONTROL
WHBR
OR
PANE L TRAY
11 1298765432110
F
M
CONTROL
ORYL
PANE L
107911
INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J2
J3
OUT
J1
J4
18 OR
13 WH
WH1415 WH
13 14
BL BL
WH
L2 L3T4L4
CR
1
T2A1T1L1T3
7
89
BL BL WH RD
21212
23
BL1BL
16
15
WH RD
1
WH
WH
22 WH
A2
A2
10 11 12
CB
WH56RD
17
RD
L2 L3T4L4
CR
T2A1T1L1T3
22112
4
DB
18
A2
2
A2
21
WH
RDWH
1
CB
RD
GRD
POWER CONNECTION BOX
75VA
TR
24VAC
BR
BU
FILTER
RECEPTACLE
FRONT COVER
115/120 VAC
SEE
TRANSFORMER
CONNECTION
CHART
1
WH
OR
2
3
4
BL
5
RD
6
GY
GRWH BL
60 HZ.
FM
1
2
3
4
5
6
2019
BL RD
WH
BL
GR
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: BL - BLACK
BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #8 ARE 10 AWG, WIRES #9 TO #24
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
2. ALL OTHER WIRES ARE 18 AWG.
R-1
34 OR
1
4
C2NCNO
HL
33 42
31 32
BL
123 84567 9101112
BLBR OR
RD
3456
2BR1
POWER INPUT
J2
J3
OUT
J1
J4
OR17
TH
19
YL
PMFRTCOMT
87
36 37
3
5
C
NO6NC
4
BURD
BU YL WH
RD
8
30WH
1
FM
HOT21LOAD3NEUT
2
4039
41
YLOR YL
WHBR
OR
11 1298765432110
F
M
CONTROL
ORYL
PAN EL
107911
INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J3
J1
18 OR
WH1415 WH
CONTROL PANEL TRAY
13 WH
17 18 19
BL BL
29
WH
38 RD
35 OR
L1T3L2 L3T4L4
9
BL BL WH RD
21212
J2
BL1BL
OUT
J4
HEATING ELEMENTS
BL WH
CR1
T2A1T1
10 11WH12
BL WH
1
23
20
WH RD
22 23
21
WH
28
L1T3L2 L3
A2
A2
CR2
T2A1T1
13 14 15 16
1
1121
CB
2
22
4
567
WH
WH
DB
POWER CONNECTION BOX
SEE
TRANSFORMER
CONNECTION
24
F
M
RD
L4
A2
A2
T4
27 WH
26
CHART
123456
RD
25 BL
OR
BL RD GYWH
75VA
TR
24VAC
BR
BU
654321
RDWH
1
CB
2
8
RDBL WH
RD
GRD
32
+
S
S
-
2211MF
18, 20 TS 2006 208-240V & 480V 3 PHASE WITH BASKET-LIFT FRONT DRAIN
18, 20 TS 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY® FILTER
T T
HEATING ELEMENTS
WIRE COLOR CODES: BL - BLACK BR - BROWN B/R - BLACK/RED BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
BASKET LIFT
POWER SUPPLY BOX
RIGHT
BASKET
LIFT
BL11
BRBU
C
NO
NC
2211MF
16 14
20
15
BU
BU
BR
BR
17
BR
BRBU
10
BL
18
BU
OR WHBU BLYL BRRD GR
WH13
12
YL9
WH
C
NO
NC
BU
19
21
BR
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
480V
B/R
240V
OR
208V
RD
120V
WH
COM
BL
24V
YL
24V
BU
30WH
3
5
1
FM
NO6NC
4
2
4039
41
YLOR YL
BURD
WHBR
OR
11 1298765432110
ORYL
BU YL WH
107911
8
WH1415 WH
HOT21LOAD3NEUT
18 OR
RIGHT TIMERLEFT TIMER
F
M
CONTROL PANEL INSERT
12 WH16 WH
J3
J1
POWER INPUT
C
R-1
87
34 OR
4
1
C2NCNO
HL
FM
11
BL 48
BL
22
WH 49
WH
33
OR 50
OR
44
BU 51
BU
55
YL 52
YL
66
BR 53
BR
77
RD 54
RD
88
GR 55
GR
LEFT
BASKET
99
LIFT
BRBU
BRBU
CB 4A
POWER INPUT
J2
J3
OUT
J1
J4
OR17
PMFRTCOMT
33 42
36 37
31 32
5354
BL
BRRD
123 84567 9101112
BLBR OR
RD
2BR1
19
3456
TH
YL
RD
CONTROL PANEL TRAY
13 WH
29
WH
38 RD
35 OR
J2
OUT
J4
17 18 19
BL BL
L2 L3T4L4
T2A1T1L1T3
10 11 12
9
BL BL WH RD
21212
23
BL1BL
20
WH RD
BL WH
28 WH
A2
CR
1
A2
BL WH
1
1
2
4
WH
POWER CONNECTION BOX
21
WH
13 14 15 16
22112
567
WH
22 23
RD
L2 L3T4L4
CR
2
T2A1T1L1T3
1
RD
DB
SEE
TRANSFORMER
CONNECTION
24
CHART
FM
WH
1
1
OR
2
2
3
3
BL
4
A2
A2
27
WH
RDWH
1
CB
2
8
RDBL WH
4
RD
5
5
GY
6
6
75VA
TR
24VAC
BR
BU
2625
BL RD
GRD
NOTES: 1. WIRES #1 TO #8 ARE 10 AWG, WIRES #9 TO #24
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
2. ALL OTHER WIRES ARE 18 AWG.
3. THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE
FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX.
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN)
H - THERMOSTAT R - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
ONLY TO UNITS WITH FILTER.
2. WIRES #1 TO #8 ARE 10 AWG, WIRES #9 TO #24 ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
3. ALL OTHER WIRES ARE 18 AWG.
FM
11
BLBLRDBR45
22
R-2
87
44
46 RD
J3
J1
43 WH
34 OR
3
5
1
4
1
C2NCNO
2
HL
47 BR
31 32
123 84567 9101112
RD
3456
2BR1
19
YL
POWER INPUT
OR17
C
NO6NC
4
J2
OUT
J4
P MF RTC OMT
R-1
87
33 42
36 37
BL
BLBR OR
TH
5
C
NO6NC
BURD
BU YL WH
RD
8
3
1
4
2
4039
YLOR YL
30WH
FM
HOT21LOAD3NEUT
29
38 RD
35 OR
41
CONTROL
OR
WHBR
PANE L TRAY
11 1298765432110
F
M
CONTROL
ORYL
PANE L
107911
INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J2
J3
OUT
J1
J4
18 OR
13 WH
WH1415 WH
17 18 19
BL WH
BL BL
WH
L1T3L2 L3T4L4
CR1
T2A1T1
9
10 11WH12
BL WH
BL BL WH RD
1
21212
23
BL1BL
21
20
22 23
WH
WH RD
28
L1T3L2 L3
A2
A2
1
2
4
WH
CR2
T2A1T1
13 14 15 16
1121
CB
22
567
WH
DB
POWER CONNECTION BOX
RD
RD
GRD
24
L4
A2
A2
T4
RDWH
1
2
8
RDBL WH
SEE
TRANSFORMER
CONNECTION
CHART
F
M
123456
OR
24VAC
BR
27 WH
CB
FILTER
RECEPTACLE
FRONT COVER
BL RD GYWH
75VA
TR
BU
GRWH BL
26
RD
25 BL
654321
WH
BL
GR
115/120 VAC
60 HZ.
T T
24 TS 2006 208-240V & 480V 3 PHASE FRONT DRAIN
33
+
S
S
-
18, 20 TS 2006 WITH BASKET-LIFT 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY® FILTER
WIRE COLOR CODES: BL - BLACK BR - BROWN B/R - BLACK/RED BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
BASKET LIFT
POWER SUPPLY BOX
RIGHT
BASKET
LIFT
10
BL
BL11
BRBU
C
NO
NC
2211MF
16 14
BR
BRBU
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
18
20
BU
15
BR
BU
BU
BR
17
ONLY TO UNITS WITH FILTER.
2. WIRES #1 TO #8 ARE 10 AWG, WIRES #9 TO #24 ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
3. ALL OTHER WIRES ARE 18 AWG.
4. THIS DIAGRAM SHOWS 240 VAC SUPPLY VOLTAGE FOR THE PRIMARY SIDE OF THE TRANSFORMER FOR THE BASKET LIFT POWER SUPPLY BOX.
NOTCH
CONNECTION CHART
OR WHBU BLYL BRRD GR
WH13
12
YL9
WH
C
NO
NC
19
BU
BR
21
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
TRANSFORMER
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
B/R
OR
RD
WH
BL
YL
BU
480V
240V
208V
120V
COM
24V
24V
FM
11
BLBLRDBR45
22
FM
11
BL 48
BL
22
WH 49
WH
33
OR 50
OR
44
BU 51
BU
55
YL 52
YL
66
BR 53
BR
77
RD 54
RD
88
GR 55
GR
99
LEFT
BASKET
LIFT
BRBU
2211MF
BRBU
3
5
1
C
NO6NC
R-2
87
4
46 RD
POWER INPUT
J3
J1
2
CB 4A
J2
OUT
J4
OR17
44
PMFRTCOMT
43 WH
34 OR
4
1
C2NCNO
HL
47 BR
31 32
5354
BL
BRRD
123 84567 9101112
BLBR OR
RD
3456
2BR1
19
YL
3
5
C
NO6NC
R-1
87
4
33 42
36 37
4039
BURD
BU YL WH
RD
8
TH
YLOR YL
30WH
1
FM
HOT21LOAD3NEUT
2
41
CONTROL
WHBR
OR
PANEL TRAY
11 1298765432110
F
M
CONTROL
ORYL
PANEL
107911
INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J3
J1
18 OR
13 WH
WH1415 WH
HEATING ELEMENTS
17 18 19
BL BL
29
WH
38 RD
35 OR
9
BL BL WH RD
21212
J2
BL1BL
OUT
J4
BL WH
L2 L3T4L4
A2
CR
1
A2
T2A1T1L1T3
10 11 12
BL WH
1
23
POWER CONNECTION BOX
21
20
22 23
WH
WH RD
WH
28 WH
L2 L3T4L4
T2A1T1L1T3
13 14 15 16
1
22112
2
4
567
WH
RD
A2
CR
2
A2
27
WH
1
RD
DB
GRD
SEE
TRANSFORMER
CONNECTION
24
CHART
FM
1
1
WH
OR
2
2
3
3
4
4
BL
5
5
RD
6
6
GY
75VA
TR
24VAC
BR
BU
2625
FILTER
RECEPTACLE
115/120 VAC
60 HZ.
BL RD
WH
BL
GR
GRWH BL
RDWH
1
CB
2
8
RDBL WH
FRONT COVER
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: BL - BLACK
BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER
CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RTC - "READY TO COOK" LIGHT (GREEN)
H - THERMOSTAT R - TRANSFORMER
NOTES: 1. WIRES #1 TO #10 ARE 10 AWG, WIRES #11 TO #30
2. ALL OTHER WIRES ARE 18 AWG.
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
4
1
C2NCNO
HL
123 84567 9101112
RD
2BR1
POWER INPUT
J2
J3
OUT
J1
J4
OR17
19
P MF RTC OMT
42 OR
39 40
BL
BLBR OR
3456
TH
YL
R
87
41 52
45 46
5
C
NO6NC
BURD
BU YL WH
RD
8
3
1
4
2
5049
YLOR YL
38WH
FM
HOT21LOAD3NEUT
51
WHBR
OR
11 1298765432110
ORYL
107911
RIGHT TIMERLEFT TIMER
18 OR
WH1415 WH
F
M
CONTROL PANEL INSERT
12 WH16 WH
J3
J1
POWER INPUT
13 WH
CONTROL PANE L TRAY
J2
OUT
J4
37
47 RD
43 OR
21 22 23
BL BL
WH
11 12 13
BL BL WH
21212
BL1BL2BL
HEATING ELEMENTS
BL WH
L2 L3T4L4
A2
CR
1
A2
T2A1T1L1T3
BL
1
CB
3
24
25 26
WH
44 OR
36
L2 L3
CR
2
T2A1T1L1T3
14 15
WH
11
22
45 6
WH
WH
POWER CONNECTION BOX
WH
A2
A2
35 WH
L4
T4
27 28 29 30
WH
WH RD RD RD
L2 L3T4L4
A2
CR
3
A2
T2A1T1L1T3
16
17
18
RD
WH
1
1
1
2
2
2
7
8
RD
WHWHWH
DB
GRD
CB CBCB
48 RD
19
RD
1
2
9
RD
TRANSFORMER
CONNECTION
F
M
34 WH
L2 L3T4L4
CR
4
T2A1T1L1T3
20
RD
1
2
10
RD
SEE
CHART
123456
OR
BL
75VA
TR
24VAC
A2
A2
BR
33 WH
BU
32
RD
31 BL
654321
RD GYWH
34
24 TS 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY® FILTER
A1 B4
A3
A2 B5
B6
A1 B4
A3
A2 B5
B6
34×24 TS 2006 208-240V & 480V 3 PHASE FRONT DRAIN
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
ONLY TO UNITS WITH FILTER.
2. WIRES #1 TO #10 ARE 10 AWG, WIRES #11 TO #30 ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
3. ALL OTHER WIRES ARE 18 AWG.
FM
BLBLRDBR55
11
22
5
C
R-2
87
54
56 RD
POWER INPUT
J3
J1
OR17
53 WH
R-1
42 OR
3
1
4
1
C2NCNO
2
HL
57 BR
41 52
45 46
39 40
BL
123 84567 9101112
BLBR OR
RD
3456
2BR1
TH
19
YL
J2
J4
OUT
NO6NC
4
P MF RTC OMT
87
3
5
C
NO6NC
4
BURD
BU YL WH
RD
8
1
2
5049
YLOR YL
OR
ORYL
107911
38WH
FM
HOT21LOAD3NEUT
37
47 RD
43 OR
51
CONTROL
WHBR
PANE L TRAY
11 1298765432110
F
M
CONTROL PANE L INSERT
12 WH16 WH
RIGHT TIMERLEFT TIMER
POWER INPUT
J2
J3
OUT
J1
J4
18 OR
13 WH
WH1415 WH
21 22 23
BL BL
WH
11 12 13
BL BL WH
21212
BL1BL2BL
HEATING ELEMENTS
BL WH
L2 L3T4L4
A2
CR
1
A2
T2A1T1L1T3
BL
1
CB
3
24
WH
44 OR
14 15
11
22
45 6
WH
25 26
36
WH
L2 L3
L4
A2
CR
2
A2
T2A1T1L1T3
T4
35 WH
WH
WH
POWER CONNECTION BOX
27 28 29 30
WH RD RD RD
WH
L2 L3T4L4
CR
3
T2A1T1L1T3
17
18
16
RD
WH
1
1
1
2
2
2
7
8
RD
WHWHWH
DB
GRD
SEE
TRANSFORMER
CONNECTION
F
M
48 RD
34 WH
L2 L3T4L4
A2
A2
CB CBCB
A2
CR
4
A2
T2A1T1L1T3
33 WH
19
20
RD
RD
1
1
2
2
9
10
RD
RD
RECEPTACLE
FRONT COVER
32
CHART
31 BL
123456
OR
BL
RD GYWH
75VA
TR
24VAC
BR
BU
WH
BL
GR
GRWH BL
FILTER
115/120 VAC
60 HZ.
RD
654321
HEATING ELEMENTS
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) R - RELAY 24VAC RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. WIRES #1 TO #12 ARE 10 AWG, WIRES #13 TO #36
ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
2. ALL OTHER WIRES ARE 18 AWG.
48 OR
1
4
C2NCNO
HL
47 58
45 46
CONTROL PANEL TRAY
CONTROL PANEL INSERT
WH13
LEFT TIMER RIGHT TIMER
POWER INPUT
J2
J3
OUT
J1
J4
OR15
PPOMFTHRTC OMT
14 BR
BL
312 456789
345BL7
2BR18
17
YL
12 WH 11 WH
5
C
NO6NC
R
87
51 52
BURD
BUOR OR
RDYL9YL WH
6
44WH
3
1
FM
HOT21LOAD3NEUT
4
2
5655
57
YLOR YL
WHBR
OR
F
976548321
M
10
WH
16
OR
25 26 27
BL WH
BL BL
43
WH
53 RD
49 OR
POWER INPUT
J2
J3
OUT
J1
J4
50 OR
L2 L3 NC
A2
CR
1
A2
T2A1T1L1T3
NC NC
13
14 15WH16
BL
BL BL
CB
21212122
3
BL1BL2BL
28
29 31
BL30WH RD
42
L2 L3
CR
2
T2A1T1L1T3
17
18
WH
WH
BL
11
45 7
WH
WH
BL
32 33 34 35
WH RD RD RD
WH
54 RD
40 WH
L2 L3
NC NC
A2
A2
41 WH
1
CB CB
2
6
19
1
2
WHWHWH
CR
T2A1T1L1T3
20
WH
1
2
8
DB
A2
3
A2
21
RD
1
2
9
RD
GRD
NC NC
22 23 24
RD
1
CB
2
10
RD
POWER CONNECTION BOX
L2 L3
CR
4
T2A1T1L1T3
RD
1
2
11
RD
TRANSFORMER
CONNECTION
CHART
36
F
M
123456
NC
A2
A2
39 WH
RD
1
2
12
RD
SEE
38
RD
37 BL
654321
OR
BL
RD GYWH
75VA
TR
24VAC
BR
BU
35
A1 B4
A3
A2 B5
B6
A1 B4
A3
A2 B5
B6
34×24 TS 2006 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY® FILTER
14 CPU 2007 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY
®
FILTER
#4 - BLACK COM
#5 - RED 208V
#6 - GRAY 480V
#2 - ORANGE 240V
#1 - WHITE 120V
NOTCH
TRANSFORMER
CONNECTION CHART
REAR DRAIN
LEFT
RDS
MAGNETIC
REED SWITCH
N.C.
REAR DRAIN
RIGHT
RDS
MAGNETIC
REED SWITCH
N.C.
WIRE COLOR CODES: BL - BLACK BR - BROWN BU - BLUE GR - GREEN GY - GRAY OR - ORANGE RD - RED WH - WHITE YL - YELLOW
COMPONENT CODES: CB - CIRCUIT BREAKER CR - CONTACTOR 24VAC DB - POWER DISTRUBITION BLOCK FM - FAT MELT TIMER SWITCH GRD - GROUNDING LUG HL - HIGH LIMIT SWITCH MF - "MELT FRY" SWITCH OMT - "OVER MAX TEMP." LIGHT (RED) P - "POWER" SWITCH PO - "POWER ON" LIGHT (CLEAR) R - RELAY 24VAC RDS - REAR DRAIN VALVE SWITCH RTC - "READY TO COOK" LIGHT (GREEN) TH - THERMOSTAT TR - TRANSFORMER
NOTES: 1. FILTER RECEPTACLE & POWER CORD APPLIES
FM
11
BL
22
BL
FM
11
BL
22
BL
ONLY TO UNITS WITH FILTER.
2. WIRES #1 TO #12 ARE 10 AWG, WIRES #13 TO #36 ARE 10 AWG FOR 208/240 VOLT UNITS AND ARE 12 AWG FOR 480 VOLT UNITS.
3. ALL OTHER WIRES ARE 18 AWG.
R-2
87
RDBR63
60
BR61RD
64 RD
62
CONTROL PANEL TRAY
CONTROL PANEL INSERT
WH13
LEFT TIMER RIGHT TIMER
POWER INPUT
J3
J1
OR15
59 WH
48 OR
3
5
1
1
4
C
NO6NC
J2
OUT
J4
C2NCNO
4
2
HL
65 BR
45 46
BL
2BR18
17
YL
PPOMFTHRTC OMT
14 BR
44WH
3
5
1
C
NO6NC
R-1
87
4
2
47 58
51 52
5655
57
YLOR YL
BURD
312 456789
345BL7
12 WH 11 WH
OR
RDYL9YL WH
BUOR OR
6
FM
HOT21LOAD3NEUT
43
53 RD
49 OR
WHBR
F
976548321
M
POWER INPUT
J2
J3
OUT
J1
J4
10
WH
16
OR
HEATING ELEMENTS
25 26 27
BL WH
BL BL
WH
L2 L3 NC
A2
CR
1
A2
T2A1T1L1T3
13
14 15WH16
BL
BL BL
CB
21212122
3
BL1BL2BL
28
29 31
BL30WH RD
50 OR
42
L2 L3
NC NC
A2
CR
2
A2
T2A1T1L1T3
NC NC
41 WH
17
18
WH
BL
WH
1
11
CB CB
2
6
45 7
WH
BL
WH
POWER CONNECTION BOX
32 33 34 35
WH RD RD RD
WH
L2 L3
A2
CR
3
A2
T2A1T1L1T3
21
19
20
RD
WH
1
1
1
2
2
2
8
9
RD
WHWHWH
DB
54 RD
40 WH
L2 L3
CR
4
T2A1T1L1T3
NC NC
22 23 24
RD
RD
1
1
CB
2
2
10
11
RD
RD
GRD
SEE
TRANSFORMER
CONNECTION
CHART
36
F
123456
M
NC
A2
A2
39 WH
RD
1
2
12
RD
FILTER
RECEPTACLE
FRONT COVER
38
RD
37 BL
654321
OR
BL
RD GYWH
75VA
TR
24VAC
BR
BU
WH
BL
GR
GRWH BL
115/120 VAC
60 HZ.
36
34x24 CPU 2007 208-240V & 480V 3 PHASE WITH REAR DRAIN AND SAFE & EASY® FILTER
37
KEATING FRYER SPECIFICATIONS
10×11 BB MODELS 14 BB
AMPS
VOLTS kW
SINGLE
L1 L2 L3
PHASE
208 6.7 19 19 19 32
220 7.5 20 20 20 34
240 8.9 21 21 21 37
480 8.9 11 11 11 19
AMPS PER LINE-THREE PHASE
3 ELEMENTS (2500 W EACH)
AMPS
VOLTS kW
SINGLE
L1 L2 L3
PHASE
208 11.7 33 33 33 56
220 13.1 34 34 34 59
240 15.5 37 37 37 65
480 15.5 19 19 19 32
AMPS PER LINE-THREE PHASE
3 ELEMENTS (4350 W EACH)
AMPS
VOLTS kW SINGLE
L1 L2 L3 PHASE
208 21.5 68 68 45 103
220 24.0 72 72 47 109
240 28.6 79 79 52 119
480 28.6 39 39 26 60
AMPS PER LINE-THREE PHASE
4 ELEMENTS (6000 W EACH)
24 BB
AMPS
VOLTS kW
SINGLE
L1 L2 L3
PHASE
208 16.1 45 45 45 77
220 18.0 47 47 47 82
240 21.4 52 52 52 89
480 21.4 26 26 26 45
AMPS PER LINE-THREE PHASE
3 ELEMENTS (6000 W EACH)
18/20 BB
AMPS
VOLTS kW SINGLE
L1 L2 L3 PHASE
208 28.6 68 89 68 129
220 30.0 72 95 72 136
240 35.7 79 103 79 149
480 35.7 39 52 39 74
AMPS PER LINE-THREE PHASE
5 ELEMENTS (6000 W EACH)
34×24 BB
* RATINGS ARE THE SAME FOR FLOOR MODELS AND COUNTER MODELS
38
TS MODELS
10×11 TS 14 TS
AMPS
VOLTS kW
SINGLE
L1 L2 L3
PHASE
208 10.2 28 28 28 49
220 11.4 30 30 30 52
240 13.6 33 33 33 57
480 13.6 16 16 16 28
AMPS PER LINE-THREE PHASE
3 ELEMENTS (3800 W EACH)
AMPS
VOLTS kW SINGLE
L1 L2 L3 PHASE
208 17.4 48 48 48 84
220 19.5 51 51 51 89
240 23.2 56 56 56 97
480 23.2 28 28 28 48
AMPS PER LINE-THREE PHASE
3 ELEMENTS (6500 W EACH)
AMPS
VOLTS kW SINGLE
L1 L2 L3
PHASE
208 26.8 68 89 68 129
220 30.0 72 95 72 136
240 35.7 79 103 79 149
480 35.7 39 52 39 74
AMPS PER LINE-THREE PHASE
5 ELEMENTS (6000 W EACH)
24 TS
AMPS
VOLTS kW
SINGLE
L1 L2 L3
PHASE
208 21.5 68 68 45 103
220 24.0 72 72 47 109
240 28.6 79 79 52 119
480 28.6 39 39 26 60
AMPS PER LINE-THREE PHASE
4 ELEMENTS (6000 W EACH)
18/20 TS
AMPS
VOLTS kW SINGLE
L1 L2 L3 PHASE
208 32.2 89 89 89 155
220 36.0 95 95 95 164
240 42.8 103 103 103 179
480 42.8 52 52 52 89
AMPS PER LINE-THREE PHASE
6 ELEMENTS (6000 W EACH)
34×24 TS
* RATINGS ARE THE SAME FOR FLOOR MODELS AND COUNTER MODELS
SERVICE INFORMATION
If you have a service related question call 1-800-KEATING.
Please state the nature of the call; it will ensure speaking with the appropriate person.
Have your serial and model number available when ordering parts.
KEATING OF CHICAGO, INC.
8901 W. 50th Street, McCook, Illinois 60525-6001
Phone: (708) 246-3000 FAX: (708) 246-3100 Toll Free 1-800-KEATING (In U.S. and Canada)
www.keatingofchicago.com
*As continuous product improvement occurs, specifications may be changed without notice.
KEATING LIMITED WARRANTY CARD
PLEASE COMPLETE AND MAIL AT ONCE–WARRANTY IS NOT IN EFFECT UNTIL CARD IS RETURNED.
WARRANTY CARD IS ALSO AVAILABLE TO COMPLETE ON LINE AT YOUR CONVENIENCE.
COMPANY: __________________________________________________________________________________________________________________________
ADDRESS: __________________________________________________________________________________________________________________________
CITY: ______________________________________________________________________________ STATE: ________________ ZIP: ____________________
DEALER: ____________________________________________________________________________________________________________________________
DATE OF PURCHASE: ________________________________________________________________ INVOICE NUMBER: ____________________________
SERIAL NUMBER: ________________________________________  FRYER FI LTER SYSTEM  GRIDDLE
REMARKS: ______________________________________________ TOP-SIDE COOKER HOT PLATE PASTA PLUS
I HAVE READ THE INSTALLATION AND OPERATION INSTRUCTIONS.
SIGNED: __________________________________________________________________________________ DATE:__________________________________
“Serving Those Who Serve The Very Best “
®
Loading...