1967-3 DUALTEMPERATURE DISPLAY W/ SWITCH
ONE WAY SWITCH: |
|
|
LIGHT |
RED WIRE |
|
|
|
|
FAN |
WHITE |
NEUTRAL |
MOTOR |
|
BLACK
LINE
RED |
WHITE |
BLACK |
RED |
THREEWAYSWITCH:
Using 1967-3 with 1908-603 (threeway switch)
WHITE NEUTRAL
YELLOW
LINE
PURPLE
WHITE |
BLACK |
YELLOW |
PURPLE |
1967-3 RED
2 of 4
SPECIFICATION:
Mechanical:
Dimensions: 2.9" [74mm] X 4.73" [120mm] Enviroment: TYPE3R (RAIN TIGHT) Purpose of Control: Operating Control Methode of Mounting Control:
Independant flush mounted standard single ganged device box (junction box)
Type of action additional features: 1.B Control Pollution Degree: 2
Software Class and Structure: Class A Rate Impulse Voltage: 2500 Temperature Sensing Range:
-40 $ F[-40 $ C] to 104 $ F[40 $ C]
Electrical:
Voltage 120VAC [240VAC OPTIONAL] Relay Current:
15 AMP Resitive / General Use @ 104 $ F [40 $ 16 AMP Resistive / General Use @ 77 $ F [25 $ C
Battery: 9 volt (not provided) Digital Temperature Probe:
2 connections (one probe provided)
Reglatory:
cULus Listed E110724 NSF
RoHS
Warranty: 1 year from Date of Purchase
LIGHT
FAN
MOTOR
RED
WHITE |
RED |
1908-603