Kanomax AL900 Data sheet

Page 1
Rosco Laboratories Inc.
A
I
I
E
April 15, 2012
52 Harbor View Avenue
Stamford, CT, USA, 06902
Phone: (203) 708 8900
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
MSDS Preparation Date:
SECTION 1 - PRODUCT AND COMPANY IDENTIFICATION
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
Product Name
: :
Product Use
Chemical Family
Supplier’s name and address:
:
Rosco Laboratories Inc.
52 Harbor View Avenue Stamford, CT, United States 06902
24 Hr. Emergency Tel #
HMIS Rating
WHMIS Classes:
Fog fluid
queous glycol solution
(800) 424-9300
:
:
- Chronic hazard 0 - Minimal 1 - Slight 2 - Moderate 3 - Serious 4 - Severe
*
1 Reactivity: Flammability:Health: 0 0
MSDS No.:ROS002
Page 1 of 6
Unregulated
SECTION 2 - COMPOSITION/INFORMATION ON INGREDIENTS
ACGIH TLV
Ingredients
Triethylene glycol 1,3-Butylene glycol Propylene glycol
Deionized water
* Note: The ACGIH TLV listed above for the following ingredient(s) is an AIHA WEEL: Propylene glycol.
CAS #
112-27-6
107-88-0
57-55-6
N/Av
% (weight)
N/Av N/Av N/Av 50 ppm( t ot al)
N/Av
N/Av N/Av
10 mg/m3
N/Av
STEL TWA STELPEL
N/Av N/Av N/Av
N/Av
OSHA PEL
N/Av N/Av N/Av N/Av
; 10 mg/m3
(aerosol)
N/Av
N/Av
N/Av
SECTION 3 - HAZARDS IDENTIFICATION
EMERGENCY OVERVIEW
Green liquid. Faint odor. No special hazards exist with this product. As with any chemical substance, caution and care will prevent
unnecessary accidents and safety problems. Read instructions on label before use. HEALTH CAUTION: Fog from this fluid, like any other
common material in an aerosolized state, may be irritating to or cause allergic symptoms in some persons with allergenic
sensitivity. Persons with active asthma should limit their exposure to the fog.
***POTENTIAL HEALTH EFFECTS***
None reported by the manufacturer.
: Target organs
Routes of exposure
Potential acute health effects :
yes:
Skin:
:
May cause mild transient irritation.
May cause irritation.
nhalation:
YES NO YES YES
Skin Absorption: Skin & Eyes:
ngestion:
Page 2
Rosco Laboratories Inc.
I
I
April 15, 2012
52 Harbor View Avenue
Stamford, CT, USA, 06902
Phone: (203) 708 8900
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
MSDS Preparation Date:
nhalation: ngestion:
Potential chronic health effects
Medical conditions aggravated by overexposure
Potential environmental effects
Can cause irritation of the respiratory tract. Persons suffering from asthma or reactive airway disorders may
experience asthma-like effects from exposure to this material.
Not an expected route of entry. Ingestion of large amounts may cause nausea, vomiting, diarrhea, as well as
depression of the central nervous system.
None reported by the manufacturer.
:
Pre-existing skin and respiratory disorders.
:
Additional health hazards
:
None reported by the manufacturer.
None reported by the manufacturer.
:
SECTION 4 - FIRST AID MEASURES
Inhalation problems are not anticipated. Remove exposed person to fresh air if adverse
Inhalation
:
effects, such as breathing difficulty arise. If irritation persists, seek prompt medical attention.
Skin contact :
Eye contact :
Ingestion
Flush skin with large amounts of water. Wash affected areas with soap and water. Remove and wash contaminated clothing before re-use. Obtain medical attention if symptoms develop and persist.
If in eyes, rinse with water for 15 minutes. Lift upper and lower lids during flushing to ensure complete removal of chemical. If irritation persists, seek prompt medical attention.
Ingestion of large amounts may be harmful. Keep at rest. Seek immediate medical
:
attention/advice. Low degree of toxicity. Treat symptomatically.
:
Notes For Physician
MSDS No.:ROS002
Page 2 of 6
SECTION 5 - FIRE FIGHTING MEASURES
Fire hazards/conditions of flammability
:
Flammability classification (OSHA 29 CFR 1910.1200)
:
Flash point Flash point Method
Lower flammable limit (% by vol.)
Suitable extinguishing media
Explosion data: Sensitivity to mechanical impact / static discharge
Special fire-fighting procedures/equipment
Hazardous combustion products
:
:
: :
:
: :
:
Not flammable under normal conditions of handling.
Not flammable. Not available. Not available.
Extinguishing media - large fires: Non-flammable aqueous liquid, all-purpose foam Extinguishing media - small fires: Carbon dioxide (CO2) , Dry chemical.
Not expected to be sensitive to mechanical impact or static discharge.
Auto-ignition temperature
Upper flammable limit (% by vol.)
None reported by the manufacturer.
Oxides of carbon. None known or reported by the manufacturer.
Oxidizing properties
SECTION 6 - ACCIDENTAL RELEASE MEASURES
Personal precautions Environmental precautions
Spill response/cleanup
:
Wear suitable protective clothing (see Section 8). No special environmental precautions required.
:
Evacuate personnel to safe areas. Restrict access to area until completion of clean-up.
:
Recover free liquid or cover with inert absorbent material and place into appropriate container for disposal. Dispose in accordance with all applicable federal, state, provincial and local regulations. Contact your local, state, provincial or federal environmental agency for specific rules.
Not available.
:
Not available.Not available.
:
Page 3
Rosco Laboratories Inc.
A
V
April 15, 2012
52 Harbor View Avenue
Stamford, CT, USA, 06902
Phone: (203) 708 8900
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
MSDS Preparation Date: Containment :
Recover free liquid or cover with inert absorbent material and place into appropriate container for disposal. Dispose in accordance with all applicable federal, state, provincial and local regulations. Contact your local, state, provincial or federal environmental agency for specific rules.
SECTION 7 - HANDLING AND STORAGE
Safe Handling procedures :
Storage requirements :
Incompatible materials :
Special packaging materials
Do not ingest. Do not inhale aerosol. Avoid contact with skin and eyes. Keep containers tightly closed when not in use. Use with adequate ventilation. Avoid breathing vapors.
Store in a cool, dry, well-ventilated area. Inspect periodically for damage or leaks. Do not store near any incompatible materials (see Section 10). Do not freeze. Keep container tightly closed when not in use.
Strong oxidizing agents and acids.
Liquid-proof glass, plastic or non-corrodible metal containers are recommended.
:
SECTION 8 - EXPOSURE CONTROLS AND PERSONAL PROTECTION
Ventilation and engineering measures
General mechanical ventilation is sufficient for use with this product.
:
Respiratory protection :
Skin protection
Other protective equipment General hygiene considerations
:
None required under normal conditions. None required under normal conditions. Gloves of natural rubber or polyvinyl chloride-
coated gloves are recommended. None required under normal conditions. If splashing might occur, wear eye protection such
: Eye / face protection
as safety glasses with side shields.
Emergency showers and eyewash facilities should be nearby.
:
Wash hands before breaks and immediately after handling the product. Wash hands before
:
breaks and at the end of workday.
MSDS No.:ROS002
Page 3 of 6
SECTION 9 - PHYSICAL AND CHEMICAL PROPERTIES
Physical state
Odor
pH
Boiling point Melting/Freezing point
Vapor pressure (mmHg @ 20° C / 68° F)
apor density (Air = 1)
Volatile organic Compounds (VOC's) (lbs/gal; g/l)
Viscosity Special Remarks On Fire Hazards
:
Liquid.
:
Faint odor.
: Odor threshold
7.0 (approximately)
:
100-243 °C Not available.
:
8.4 (approximately)
:
2.9
: Evaporation rate (n-Butyl acetate = 1)
Not available.
:
Not available.
Not flammable under normal conditions of use.
:
SECTION 10 - REACTIVITY AND STABILITY DATA
Stability and reactivity : Hazardous polymerization Conditions to avoid
Materials To Avoid And Incompatibility
Hazardous decomposition products
Stable under normal conditions. Will not occur.
:
Combination with strong oxidizers and/or acids may cause explosive decomposition.
:
Strong oxidizing agents and acids.
:
ppearance
Coefficient of water/oil distribution
Solubility in water
Green liquid.
:
Not available.
:
1.12 (approximately)
:
Specific gravity :
Not available.
:
soluble
:
0.01
:
Not available.
: Volatiles (% by weight)
Page 4
Rosco Laboratories Inc.
April 15, 2012
52 Harbor View Avenue
Stamford, CT, USA, 06902
Phone: (203) 708 8900
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
MSDS Preparation Date:
None.
:
SECTION 11 - TOXICOLOGICAL INFORMATION
LC50(4hr)
Ingredients
Triethylene glycol 1,3-Butylene glycol Propylene glycol Deionized water
Toxicological data :
Carcinogenic status Reproductive effects
Mutagenicity
Reproductive Effects :
Irritancy
:
: : : Teratogenicity
:
inh, rat
N/Av 12,800 mg/kg (rat) N/Av 18610 mg/kg (rat) N/Av 20,000 mg/kg (rat) N/Av >90 mL/kg (rat)
Low order of toxicity for normal industrial handling.
No components are listed as carcinogens by ACGIH, IARC, OSHA or NTP.
Not expected to have other reproductive effects. Not expected to be a teratogen. Not expected to be mutagenic in humans. Not expected to have other reproductive effects. Direct contact may cause mild eye irritation. Possible inhalation irritant. Irritating to skin.
oral
MSDS No.:ROS002
Page 4 of 6
LD50
dermal
22,460 mg/kg (rabbit)
> 20000 mg/kg (rabbit)
20,800 mg/kg (rabbit)
N/Av
Sensitization to material :
Not expected to be a sensitizer. None reported by the manufacturer.
Synergistic materials
:
SECTION 12 - ECOLOGICAL INFORMATION
Environmental effects : Important environmental characteristics
Ecotoxicological
None known or reported by the manufacturer. However, it is recommended not to allow the material to enter the environment.
None known or reported by the manufacturer.
:
No data is available on the product itself.
:
SECTION 13 - DISPOSAL CONSIDERATIONS
See Section 7 (Handling and Storage) section for further details.
: Handling for Disposal
Methods of Disposal :
Contact waste disposal services. Dispose in accordance with all applicable federal, state, provincial and local regulations. Contact your local, state, provincial or federal environmental agency for specific rules.
SECTION 14 - TRANSPORTATION INFORMATION
Regulatory
Information
TDG
TDG
Additional
information
49CFR/DOT
UN Number Shipping Name
None
None.
Not regulated.
None
Not regulated.
Packing
Group
-None-
-None-
Label
Class
Not regulated
Not regulated
49CFR/DOT
Additional
information
None.
Page 5
Rosco Laboratories Inc.
A
p
April 15, 2012
52 Harbor View Avenue
Stamford, CT, USA, 06902
Phone: (203) 708 8900
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
MSDS Preparation Date:
ICAO/IATA
ICAO/IATA
Additional
information
IMDG
IMDG
Additional
information
None
None.
None
None.
Not regulated.
Not regulated.
Not regulated
Not regulated
-None-
-None-
MSDS No.:ROS002
Page 5 of 6
SECTION 15 - REGULATORY INFORMATION
US Federal Information:
TSCA: All listed ingredients appear on the Toxic Substances Control Act (TSCA) inventory. SARA Section 313: This material is not subject to SARA notification requirements, since it does not contain any Toxic Chemical Constituents above de minimus concentrations.
US State Right to Know Laws:
California Proposition 65: To the best of our knowledge, this product does not contain any chemicals known to the State of California to cause cancer or reproductive harm.
Canadian Regulations:
Canadian Environmental Protection Act (CEPA) information: All ingredients listed appear on the Domestic Substances List (DSL).
Canadian WHMIS Classification: Not regulated.
This product has been classified according to the hazard criteria of the CPR and the MSDS contains all of the information required by the CPR.
SECTION 16 - OTHER INFORMATION
Legend :
References :
Prepared for:
Rosco Laboratories Inc . 52 Harbor View Avenue Stamford, CT, USA, 06902 Phone: (203) 708 8900
http://htt
://www.rosco.com/
Prepared by:
ICC The Compliance Center Inc.
Canada: 1-888-977-4834 USA: 1-888-442-9628
http://www.thecompliancecenter.com
CGIH: American Conference of Governmental Industrial Hygienists IARC: International Agency for Research on Cancer N/Ap: not applicable N/Av: not available NIOSH: National Institute of Occupational Safety and Health NTP: National Toxicology Program OSHA: Occupational Safety and Health Administration
Information obtained from sources including original supplier's Material Safety Data Sheet, and references including RTECS and CCOHS Cheminfo.
Page 6
Rosco Laboratories Inc.
f
r
April 15, 2012
April 15, 2012
52 Harbor View Avenue
Stamford, CT, USA, 06902
Phone: (203) 708 8900
ROSCO FOG FLUID & ROSCO SMOKE SIMULATION FLUID
MSDS Preparation Date:
MSDS No.:ROS002
Page 6 of 6
DISCLAIMER OF LIABILITY
Every effort has been made to ensure that the safety information on this sheet is accurate, but because Rosco Laboratories, Inc. has no control over the conditions under which the product will be used, liability is limited exclusively to replacement or refund o the purchase price of this product. Except as stated herein, there are no express or implied warranties, including implied warranties of merchantability or fitness for a particular purpose. Rosco Laboratories, Inc. assumes no liability for injury o incidental or consequential damages arising out of storage, handling or use of this product.
Preparation Date:
END OF DOCUMENT
Loading...