Kanomax A531, A541, A542, A533, A543 Data sheet

Air Velocity, Air Temperature,
Relative Humidity,
Climomaster Series
Differential Pressure
Multi-Function Thermal Anemometer
Ventilation Testing Laboratory Control Cleanrooms IAQ Investigation Industrial Hygiene Quality Control
NIST Traceable
Features:
x Probe Compatibility feature allows utilization of a spare probe x Detachable probe allows for easy replacement, and for
A531 A541 A542 A533 A543
compatibility with multi-function thermoanemometers
x Automatic Flow Rate Calculation function x RS232C terminal for data logging x Stores up to 1500 measurement data x Differential Pressure available as an option
Benefits:
x If you have more than one unit, detachable probe allows you to share the main unit or the probe. x Gives automatic flow rate readings by registering duct sizes (up to 25 duct sizes). x Well designed software allows you to access the data instantly. x You can store the data or upload it to your PC via RS232C cable and software (both optional)
Specifications
Model A531 A541 A542 A533 A543
Air Velocity Range 20 to 6000fpm (0.10 to 30.0m/s) 10 to 1000fpm (0.05 to 5.00m/s) Air Temperature Range 32.0 to 140.0ºF (0.0 to 60.0ºC) Relative Humidity Range 2.0 to 98.0%RH -- 2.0 to 98.0%RH -­Differential Pressure (Option) -5.00 to +5.00kPa
Velocity: +/-2% of reading or +/-3fpm (+/-0.015m/s) whichever is greater
Accuracy
Output
Power Supply 6 x 1.5V AA Batteries, AC Adapter (Optional): AC100-240V Battery Life Approx. 10hrs. Continuous at 984fpm (5m/s), 68ºF (20ºC) with alkaline batteries
Environment Storage Environment 41-104ºF (5 to 40ºC) Weight Approx. 0.9lbs (400g) Standard Kit Carrying Case, Operation Manual, AA Batteries, Probe Cable Optional Accessories
Digital RS-232C (Baud Rate 4800, 9600, 19200 and 39400bps) Analog DC0-1V (Select from Air Velocity, Air Temperature, Relative Humidity and Pressure)
Main Unit 41 to 104ºF (5 to 40ºC) Operating Probe 32 to 140ºF (0 to 60ºC)
Spare Probe, Analog Output, Pressure Sensor, Extension Rod, Printer, Printer Cable, Communication Cable, Software (for Windows), AC Adapter: AC100-240V 50/60Hz
Relative Humidity: +/-2.0%RH from 2 to 80%RH, +/-3%RH from 80 to 98%RH
Air Temperature: +/- 1 ºF (+/-0.5 ºC)
Differential Pressure: +/- (3% of reading +0.01)kPa
Selection Guide
Model Measuring Range Probe Type Directivity Velocity & Temp. Relative Humidity
A531 20 - 6,000 fpm Rod Mono ٤٤ A541 20 - 6,000 fpm Rod Mono ٤ A542 20 - 6,000 fpm Needle Omni ٤ A533 10 - 1,000 fpm Spherical Omni ٤٤ A543 10 - 1,000 fpm Spherical Omni ٤
Kanomax USA, Inc. USA: 1-800-247-8887 Tel: +1-973-786-6386 Fax: 973-786-7586 www.kanomax-usa.com