Kairak BLU Drop-in Pan Chillers User Manual

InstructIon Manual
KBD DroP-In Pan cHIllEr
INSTRUCTION MANUAL
KBD DROP-IN PAN CHILLERS
SELF CONTAINED AND REMOTE MODELS
BLU TECHNOLOGY DROP-IN PAN CHILLERS
efcient heat transfer. Our NSF7 approved BLU pan chilling system ensures condiments for salads, pizzas,
and sandwiches always stay fresh without the need for fans, blower coils or other refrigeration enhancing components.
Standard features on the KBD models include stainless steel construction and LED temperature display
(self-contained models only).
KBD models are available as self-contained or remote installations. Available options include sloped or at
rail, optional night cover and extra depth pan opening.
REMOTE REFRIGERATION & BLU
Kairak is committed to producing environmentally friendly and sustainable product offerings without
sacricing quality or reliability, Kairak’s Remote Refrigeratioin Systems assures customers maximum energy
savings and a substantially smaller environmental footprint.
Energy savings are available by combining our BLU Technology Remote Rack Systems with Kairak’s BLU products such as Prep Tables, Drop-in Pan Chillers or Equipment Stands.
SALES KAIRAK. 1158 N. Gilbert St., Anaheim, CA 92801, Phone: (714) 870-8661, Web: www.kairak.com
MNFG KAIRAK. 4401 Blue Mound Road, FT. Worth, TX 76106
© KAIRAK, a division of ITW Food Equipment Group LLC. All Rights Reserved.
DROP-IN PAN CHILLERS
PAGE 1
TABLE OF CONTENTS
1. THE SERIAL TAG
2. RECEIPT INSPECTION
3. INSTALLATION
A-Installing the Pan Chiller B-Field Prep C-Refrigeration Lines D-Electrical Connections
4. STARTUP INSTRUCTIONS
5. ELECTRICAL CONNECTIONS
6. PRESTART CHECKS
A-Control/Temperature Settings B-Removing Food Product at Night C-Leaving Food Product in at Night
7. OPERATION
8. MAINTENANCE PROCEDURES
A-Cleaning B-Cleaning Condensing Unit
9. TROUBLESHOOTING GUIDE
PAGE 3
PAGE 4
PAGE 4 PAGE 4 PAGE 4 PAGE 4 PAGE 4
PAGE 5
PAGE 6
PAGE 6 PAGE 6 PAGE 6 PAGE 7
PAGE 7
PAGE 8 PAGE 8 PAGE 8
PAGE 9
10. TIPS
11. PRODUCT REGISTRATION INFO
12. WARRANTIES
PAGE 10
PAGE 10
PAGE 11
DROP-IN PAN CHILLERS
PAGE 2
1. THE SERIAL TAG
The serial tag is a permanently afxed label on which is recorded vital electrical and refrigeration data about
your Kairak product, such as the movcvvstallation, test the electrical service to assure that it agrees with
the specications of the equipment marked on the serial tag.
READING THE SERIAL TAG
500 S. State College Blvd. Fullerton, CA 92831
MODEL NO.
SERIAL NO.
TYPE
VOLTS
HERTZ
AMPS
REFRIGERANT TYPE
REFRIGERANT AMOUNT
SECONDARY COOLANT
DESIGN PRESSURES (PSI)
SECONDARY COOLANT
REFRIGERANT
LOAD REQUIREMENT
EVAP TEMP
DATE MANUFACTURED
COMMERCIAL REFRIGERATORS AND/OR FREEZERS
KBD-46S
39XXX
DROP IN
115
60
8.7
R-134a
14 oz.
PROPYLENE GLYCOL
LOW HIGH
20 40
162 440
06/2008
UL File SA10235
ANSI/NSF 7
UNION MADE BY SHEET METAL LOCAL 170
WO/2007/127133MEA #242-94-E VOL. II
DROP-IN PAN CHILLERS
PAGE 3
2. RECEIPT INSPECTION
All Kairak products are factory tested for performance and are free from defects when shipped. The utmost care has been taken in crating this product to protect against damage in transit.
Carefully inspect your Kairak unit for damage during delivery. If damage is detected, you should save all
crating materials and make note on the carrier’s Bill of Lading describing the damage. A freight claim should be led immediately. If damage is subsequently noted during or immediately after installation, contact the respective carrier and le a freight claim. There is a fteen (15) day limit to le freight damage with the carrier. Under no condition may a damaged unit be returned to Kairak without rst obtaining written permission (return authorization). You may contact Kairak customer care at (800) 833-1106.
3. INSTALLATION
3A - FIELD PREPARATION
Both self-contained and remote units require a counter cut-out that is 3/8” inch less than the overall outer dimension of the pan chiller. Refer to the specication sheet for your particular unit.
3B - INSTALLING THE PAN CHILLER (SELF-CONTAINED MODELS)
Self-contained units must be installed with sufcient air circulation for the condensing unit. Venting must include provisions for both air intake and exhaust. Failure to provide adequate ventilation may cause severe
compressor damage, and will void warranty.
3C - REFRIGERATION LINES (REMOTE UNITS)
NOTE: BLU REMOTE INSTALLATIONS ARE TO BE PERFORMED OR SUPERVISED BY KAIRAK ONLY.
Location of the refrigeration lines varies depending on installation needs.
Kairak supplies three connections marked:
4“Glycol IN” 4“Glycol OUT” 4“Drain”
3D - ELECTRICAL CONNECTIONS
Refer to the wiring diagram shipped with the unit located inside the compressor compartment or on the
back of the unit.
CORD CONNECTED UNITS (Self-contained models)
Plug the unit into a properly sized outlet. See serial tag located inside lower storage cabinet for circuit sizing.
WARNING: THIS MACHINE IS PROVIDED WITH A THREE-PRONGED GROUNDING PLUG. THE OUTLET TO WHICH THIS PLUG IS CONNECTED MUST BE PROPERLY GROUNDED. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN.
DROP-IN PAN CHILLERS
PAGE 4