JVC TS-C420P9W Service Manual

Page 1
52109200304
A
SERVICE MANUAL
WALL MOUNTING UNIT
TS-C420P9W
<External Dimensions>
Mass: 10 kg
ngles of Inclination: 0 , 5 , 10 , 15 , 20
Wall Mounting Holes
13
13 13
8
4-R10
470
400
340
130
4-R10
13
42-inch Display
20
300
89 49
TS-C420P9W
110 2 0
20
20 20
190 170
499
E F
20
131
6-R10
E Section Details
20
1 113
110 50
20 160
180
13
60 120 120
568
13
20
13 1
(Outer edge)
6-R10
F Section Details
13
20
131
8.5 20
159.5 101.5 140 81.5 16.5
Wall Mounting Unit Exterior
13
20
13
(Units in millimeters)
1 ASSEMBLY AND MOUNTING INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
COPYRIGHT © 2003 VICTOR COMPANY OF JAPAN, LTD.
No.52109
2003/04
Page 2
TS-C420P9W
Ç

ASSEMBLY AND MOUNTING INSTRUCTIONS

ENGLISH
AIS
DEUTSCHESPAÑOL ITALIANO
Assembly and Mounting Instructions
For Assembly By Authorized Service Personnel Only
Consult authorized service personnel for the installation of this unit. Installation
instructions must be followed precisely in order to prevent accidents. We are
selling this product with the understanding that it will be assembled and installed
by properly trained and qualified service personnel.
FRAN
Danger
We are not liable for any damage caused by faulty assembly,
faulty wall mounting, insecure wall mounting, misuse,
alterations, or natural disasters.
This unit weighs approx. 45 kg (approx. 99 lbs.) including plasma display monitor.
Incomplete or inadequate mounting of this unit to the wall may cause it to fall
down, resulting in potentially fatal accidents.
Please consult authorized service personnel for the installation of this unit.
89 49
300
20°
42-inch Display
16.5
13
13
470
400
2-φ5
4-R10
130
340
<External Dimensions>
Wall Mounting Holes
4-R10
Mass: 10 kg
Angles of Inclination: 0°, 5°, 10°, 15°, 20°
13
13
2-φ5
8190
Wall Mounting Unit
499
81.5159.5
2-φ8
2-φ8
140101.5
20
110 2016020
170131
2020
2020
F
F Section
E
E Section
8.5
50110
Mounting a plasma display television requires specific technical knowledge. Do not attempt to mount the unit by yourself.
Please be aware that screw holes and anchor bolts will remain in the wall surface if the Wall Mounting Unit is removed
after having been mounted to the wall.
Thank you for purchasing this Wall Mounting Unit.
We recommend that you read this manual thoroughly before use in order to familiarize yourself with this unit.
Please store this manual in a safe place after reading it.
TS-C420P9W
Long-term use of the plasma display may result in discoloration of the wall surface due to heat/air emitted by the display.
2-φ8
20
Wall Mounting Unit Exterior
120180
6-R10
(Outer edge)
568
60 120
6-R10
2-φ5
1313
1313
F Section Details
2-φ5
2-φ5
E Section Details
2-φ5
13 1
20
2-φ8
20
2-φ8 1
13
20
(Units in millimeters)
1 13
13 1
2-φ8
VICTOR COMPANY OF JAPAN, LIMITED
© 2003 VICTOR COMPANY OF JAPAN, LIMITED
16
1-2 (No.52109)
Page 3
TS-C420P9W
3
ENGLISH
Warning
Mounting the Wall Unit
The Wall Mounting Unit should be mounted to a wall that can adequately
hold the total weight of the plasma display and the Wall Mounting Unit
over a long period of time and which can adequately withstand
earthquakes, conceivable vibrations, and other external forces.
Improper installation may cause the plasma display to fall down, resulting
in physical injury.
Mounting On Wooden Walls
The weight of the unit should be borne by the wall posts or studs, and
these should be reinforced if insufficiently strong. Do not install the Wall
Mounting Unit on walls made of plasterboard or thin plywood. Use the
commercially sold screws best suited for the wall structure and material.
Mounting On Concrete Walls
Use commercially sold wall anchors capable of supporting the weight of
the plasma display.
Do not install the Wall
Mounting Unit in a
location which is hot or
humid or which may
become wet, as the
presence of excessive
moisture may lead to
fire or electric shock.
Do not install the Wall
Mounting Unit near the
blower or air inlet of an air
conditioner.
Do not install the unit in a
location with a large
amount of dust, soot, or
cigarette smoke, as this
may lead to fire.
Do not block the
ventilation holes, and be
sure to leave sufficient
space around the unit
for ventilation.
Inadequate ventilation may
cause the unit interior to
overheat, leading to fire.
Plasterboard/Thin Plywood
Do not install the Wall
Mounting Unit in a
location subject to
frequent vibration, impact
or other external forces.
The unit may fall down or
be damaged, causing
physical injury.
Do not install the unit in a
location where people
may hang on it or lean
against it.
Doing so may cause the
unit to fall down or be
damaged, resulting in
injury.
Do not install the unit in
a location exposed to
direct sunlight or strong
light, as viewing the
plasma display in an
overly bright
environment can be
tiring for the eyes.
Do not install the Wall
Mounting Unit on a
non-vertical wall.
The unit interior may
overheat, resulting in fire,
or the unit may fall down,
causing physical injury.
At least
15 cm
At least
20 cm
Explanation of symbols
Safety Precautions
The following section describes the symbols used in this manual. Read this section prior to using the product for correct usage.
The following items contain information for your safety. Follow these precautions precisely.
Warning and Caution are defined as follows:
Danger
Improper handling in disregard of these notices may result in danger of death or bodily harm.
Improper handling in disregard of these notices may result in bodily injury and even death.
Mishandling of the unit in disregard of these notices may result in bodily injury or damage to
Danger
Warning
Caution
Examples:
the unit.
The indicates caution (including warning or danger).
indicates a prohibition, with the specific action indicated either in the circle itself (the
The
symbol at left means "Do Not Disassemble"), or in the accompanying text.
This unit weighs approx. 45kg (approx. 99 lbs.), including display monitor. Improper assembly or
installation may cause the unit to fall when it is mounted, which may result in fatal accidents. To
prevent this happening, check the strength of the materials in the mounting surface, and have at least
two persons carry out the installation in a suitable location. Check the material strength again after
Consult authorized service personnel for the installation and attachment of this unit to the wall.
mounting as well.
Assembly and Mounting Warnings
Warning
bodily injury due to the display monitor and stand toppling over.
Using display monitors other than those authorized by Victor with the unit may result in damage or
mounting falling down, potentially causing damage or bodily injury.
or electric shock.
Assemble all bolts, nuts and screws securely. Failure to do so may result in display monitor and wall
Avoid placing heavy objects on the power cord, as damage to the power cord may result, causing fire
hand as appropriate for the mounting location.
This unit does not come with anchor bolts for securing it to walls, etc. Be sure you have materials on
2
(No.52109)1-3
Page 4
TS-C420P9W
q Frame
ENGLISH
Wall Mounting Unit
w
5
Flat Washer
Spring Washer
the plasma display to the Wall Mounting Unit. Be sure to keep them in a safe place.
These Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers will be used when attaching
<Before Attaching Plasma Display>
The Wall Mounting Unit is sold with Frame q and Wall Mounting Unit w fixed together. The following steps should
Washer, and Spring Washer.
be performed before attaching the plasma display.
1. Take the left and right Frame Fastening Screw Components and remove the Fastening Screw, Spacer Ring, Flat
Frame Fastening Screw
Spacer Ring
Angle Adjustment Lever
Caution
<Names of Parts>
Frame Removal
Lever Screws
w Wall Mounting Unit
q Frame
Frame q from the Wall Mounting Unit w.
2. Push in the heads of the left and right Frame Removal Lever Screws a and lift up section b to remove the
q
e X 8
Lever Lock Screw
r Angle Adjustment
35-inch
Frame Rotation Shaft
w
X 12
Screws (left/right)
Spacer Rings (left/right)
Frame Attachment Lever Screws
e
Frame
Rotation Jaw
Plasma Display
q
e X 10
PD-42D30ES series
( )
42-inch PD-42DX series
Plasma Display
e Screw (M5 X 30) .......................... 12
r Screw (M5 X 20) ............................ 1
Parts bag
contains:
1-4 (No.52109)
q
installation (i.e., exposed or severed wiring) may result in fire or electric shock.
working under unsuitable conditions.
Consult authorized service personnel for electrical work. Using power cords damaged during
electric shock may result.
Conduct the work with adequate working space. Damage or bodily injury may result from
Avoid mounting this unit in areas where there is electrical wiring or water pipes, as fire or
Tools Required for Assembly:
1. Type 2 Philips Screwdriver (+)
2. Type 2 Philips Screwdriver (+) with 300mm (approx. 12-inch) or longer shaft
50-inch
Frame Fastening Screws left/right
Plasma Display
(Spacer Ring + Flat Washer + Spring Washer)
e X 10
42-inch
Plasma Display
q
<Components List>
q Frame................................................................... 1
w Wall Mounting Unit ............................................... 1
4
Page 5
TS-C420P9W
7
ENGLISH
3. Identify the Rotation Shaft Screws of the Wall Mounting Unit.
Check that the left and right Rotation Shaft Screws are secure, as the Rotation Jaw of the Frame (attached to
the plasma display) will be inserted into the Rotation Shaft Screw Component of the Wall Mounting Unit w.
Avoid inserting fingers into the gap between the Frame and the Wall Mounting Unit when
putting these together, as fingers will get trapped, causing injury.
<Instructions for Assembly, cont’d>
Caution
4. Attach the plasma display to the Wall Mounting Unit.
This task must be performed by at least two persons.
Insert the Rotation Jaw of the Frame q (attached to the plasma display) securely into the Rotation Shaft
Screw Component of the Wall Mounting Unit, then raise up the plasma unit on this axis and push it into place
- it should lock with a clicking sound. Before releasing the unit, check that the plasma display is securely fitted
and does not rattle and loose.
w Wall Mounting Unit
Rotation Shaft Screw Component
Rotation Shaft
Screw
Spacer Ring
Rotation Jaw
q Frame Rotation Jaw
Fasten all bolts and screws securely. Failure to do so may cause the plasma display and Wall Mounting
Unit to fall down, causing potentially fatal accidents.
Improper positioning/installation of the Wall Mounting Unit on the wall may cause the unit to fall down.
Check the structure, material, and strength of the mounting surface thoroughly and carry out installation
in a suitable location. Failure to do so may cause the plasma display and Wall Mounting Unit to fall
down, leading to potentially fatal accidents.
Danger
The unit should be attached using the method most suited to the wall structure.
When anchor nuts/bolts are to be inserted into the wall before mounting, either align the actual Wall
Instructions for Assembly
Mounting the Plasma Display
1. Attach the Wall Mounting Unit w to the surface of the wall.
35-inch
w Wall Mounting Unit
PD-42D30ES series
( )
42-inch PD-42DX series
Wall Surface Side
(Wall Mounting Unit)
Position of Wall
Mounting Holes
Mounting Unit w with the wall to determine the positioning of the holes or calculate the positioning of the
holes using a dimensional drawing of the unit before installing the anchor nuts/bolts.
Twelve screws (M5X30) e should be used to attach the Frame q to a 50-inch plasma display, Ten screws
(M5X30) e should be used to attach the Frame q to a 42-inch plasma display and eight screws (M5X30) e
2. Attach Frame q to the plasma display.
42-inch
A soft mat or similar material should be laid out to prevent damage to the plasma display during attachment to
the unit.
should be used to attach the Frame q to a 35-inch plasma display.
50-inch
Plasma Display
eScrews (M5X30) x 8
eScrews (M5X30) x 10
Plasma Display
Plasma Display
eScrews (M5X30) x 10
Plasma Display
eScrews (M5X30) x 12
Align the first Mounting Hole
Align the first Mounting Hole
6
(No.52109)1-5
Page 6
TS-C420P9W
ENGLISH
9
Angle Adjustment
Lever
0°
5°
10°
15°
20°
Grip the plasma display firmly while adjusting the angle, as the display could tip over and cause
injury.
Caution
The angle of the Wall Mounting Unit can be adjusted to 0°, 5°, 10°, 15°, and 20°.
Brace the upper middle part of the plasma display with one hand and push the Angle Adjustment Lever to the
left with the other hand. The plasma display will tip forward. Release the Angle Adjustment Lever when the
<Instructions for Assembly, cont’d>
Adjusting the Angle of the Plasma Display
desired angle setting is reached.
1. Adjust the angle of the plasma display.
Frame Fastening
Screw Component
Once the plasma display has been set at the desired angle, fasten the Angle Adjustment Lever with the screw
(M5X20) r.
2. Fix the Angle Adjustment Lever.
Frame Fastening Screw
Spring Washer
Flat Washer
Spacer Ring
Note: do not fasten the Angle Adjustment Lever if the power cord or system cables have yet to be attached.
r Screw (M5X20) x 1
rattle and loose.
Check to make sure that the Angle Adjustment Lever is securely fastened and the plasma display does not
<Instructions for Assembly, cont’d>
1-6 (No.52109)
Avoid inserting fingers into the gap between the Frame and the Wall Mounting Unit when
putting these together, as fingers will get trapped, causing injury.
Flat Washer
Caution
Combine the Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers (from the two pairs of
Frame Fastening Screw Components that were put aside when detaching the Frame q from the Wall Mounting
Unit w) as shown below and fasten them securely using a screwdriver.
5. Fix the Frame and Wall Mounting Unit.
Spacer Ring
Spring Washer
Frame Fastening Screw
Confirm that all of the parts are securely fastened and do not rattle and loose.
8
Page 7
TS-C420P9W
11
ENGLISH
<Instructions for Assembly, cont’d>
3. Remove the Rotation Shaft Screws and Spacer Rings at the bottom left and right of the Wall Mounting Unit.
The Rotation Shaft Screws and the Spacer Rings will be used after the cables have been connected. Be sure
to keep them in a safe place.
Spacer Rings
Rotation Shaft Screws
Rotation Shaft Screws
Brace the plasma display when connecting the power cable or system cables. Failure to do so
may allow it to tip over, potentially causing injury.
Caution
4. Pull the plasma display forward.
Brace the bottom of the plasma display and push up the heads of the screws at the left/right of the Frame
Attachment Lever Screw component at the bottom of the Wall Mounting Unit, until the screws come into contact
with the Frame. The plasma display can now be pulled forward.
This task must be performed by at least two persons.
Plasma Display
Frame
Wall Mounting Unit
Lateral View
Pull Forward
Frame Attachment Lever Screw
Component
Grip the plasma display firmly while connecting the power cord/system cables, as the display
may tip over and cause injury.
<Instructions for Assembly, cont’d>
Caution
Connecting the Power Cord and System Cables
Check that the two Frame Fastening Screws on the upper left and right sides of the Wall Mounting Unit are
securely fastened.
1. Check the Frame Fastening Screws.
Frame Fastening Screws
Caution
If the Frame Fastening Screws are not
securely fastened the plasma display
may fall, causing potentially fatal injury.
Caution
Grip the plasma display as you adjust
the angle, as the plasma display may
tip over and cause injury.
20°
Adjustment Lever Lock Screw.
If the Angle Adjustment Lever has already been fastened, perform this task after removing the Angle
to 20°.
2. Place one hand on top of the plasma display to steady it and with the other hand set the Angle Adjustment Lever
(No.52109)1-7
Angle Adjustment Lever
Lock Screw
10
Page 8
TS-C420P9W
ENGLISH
13
Angle Adjustment Lever
Caution
Grip the plasma display firmly as you
adjust the angle, as the display may
fall forward and cause injury.
0°
5°
10°
15°
20°
Hold the upper part of the plasma display with one hand and set the display to the desired angle with the other
hand, using the Angle Adjustment Lever on the Wall Mounting Unit.
7. Set the angle of the plasma display.
<Instructions for Assembly, cont’d>
Brace the plasma display while connecting the power cord or system cables, as the display may
tip over, causing injury.
Once the angle of the plasma display has been set, fasten the Angle Adjustment Lever with the Screw (M5X20)
8. Fasten the Angle Adjustment Lever.
r.
Rotation Shaft Screw
r Screw (M5X20) x 1
Rotation Shaft Screw
Spacer Ring
Check to make sure that the lever is securely fastened and the plasma display does not rattle.
<Instructions for Assembly, cont’d>
1-8 (No.52109)
Caution
5. Connect the power cable and system cables to the plasma display.
Push the bottom of the plasma display toward the Wall Mounting Unit to securely fasten the display to the Wall
Mounting Unit. Then, fasten the Rotation Shaft Screw Component at the bottom left/right of the Wall Mounting
Unit with the Rotation Shaft Screws and the Spacer Rings.
Be careful not to let the cables become caught between the plasma display and the Wall Mounting Unit.
6. Fix the Plasma Display to the Wall Mounting Unit.
This task must be performed by at least two persons.
Spacer Ring
Rotation Shaft Screw
12
Page 9
TS-C420P9W
15
ENGLISH
<Instructions for Removing the Plasma Display, cont’d.>
This task must be performed by at least two persons.
Danger
3. Remove the Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers of the two Frame
Fastening Screw Components at the upper left and right of the Wall Mounting Unit.
4. Push up the heads of the screws in the Frame Attachment Lever components at the bottom left and right of the
Wall Mounting Unit until they come into contact with the Frame. Then tilt the plasma display 90° forward and,
without changing the inclination of the plasma display, pull the display out horizontally.
Frame Fastening Screws
Frame Removal Lever Screws
This task must be performed by at least two persons.
Danger
If the Angle Adjustment Lever has been fastened, remove the Angle Adjustment Lever Lock Screw before
<Instructions on Removing the Plasma Display>
1. Hold the upper middle of the plasma display and set the Angle Adjustment Lever to 0°.
performing this task.
Angle Adjustment
Lever
Angle Adjustment Lever
Lock Screw
Rotation Shaft Screws
fastened.
2. Confirm that the Frame Rotation Shaft Screws at the left and right bottom of the Wall Mounting Unit are securely
14
(No.52109)1-9
Page 10
TS-C420P9W

EXPLODED VIEW

PARTS LIST

42-inch Plasma Display
Frame
3
8
Wall Mounting Unit
7
6
(x5)
1
3
4
6
7
8
3
2
(x5)
1
3
4
5
42-inch(PD-42DX, PD-42DXT, PD-42D30ES) Plasma Display
1
(x5)
Frame
1
(x5)
35-inch Plasma Display

EXPLODED VIEW PARTS LIST

Ref.No. Part No. Part Name Qty Description
1 PDP-414 SCREW 12 M5 × 30 2 QYSPSPD5020Z SCREW 1 M5 × 20 3 PDP-419 SCREW 4 M6 × 20 4 PDP-412 SPACER RING 2 5 PDP-422 SCREW 2 M5 × 25 6 PDP-411 SPACER RING 2 7 PDP-426 FLAT WASHER 2 8 PDP-428 SPRING WASHER 2
LC31937-005A CARTON LABEL 1 TS-C420P9W-AD INST BOOK 1 PDP-435 PACKING CASE 1
1
(x4)
Frame
1
(x4)
1-10 (No.52109)
Page 11
TS-C420P9W
(No.52109)1-11
Page 12
TS-C420P9W
VICTOR COMPANY OF JAPAN, LIMITED
AV & MULTIMEDIA COMPANY DISPLAY CATEGORY 12, 3-chome, Moriya-cho, kanagawa-ku, Yokohama, kanagawa-prefecture, 221-8528, Japan
(No.52109)
Printed in Japan
200304WPC
Loading...