JVC TS-C420P9W Service Manual

52109200304
A
SERVICE MANUAL
WALL MOUNTING UNIT
TS-C420P9W
<External Dimensions>
Mass: 10 kg
ngles of Inclination: 0 , 5 , 10 , 15 , 20
Wall Mounting Holes
13
13 13
8
4-R10
470
400
340
130
4-R10
13
42-inch Display
20
300
89 49
TS-C420P9W
110 2 0
20
20 20
190 170
499
E F
20
131
6-R10
E Section Details
20
1 113
110 50
20 160
180
13
60 120 120
568
13
20
13 1
(Outer edge)
6-R10
F Section Details
13
20
131
8.5 20
159.5 101.5 140 81.5 16.5
Wall Mounting Unit Exterior
13
20
13
(Units in millimeters)
1 ASSEMBLY AND MOUNTING INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-10
COPYRIGHT © 2003 VICTOR COMPANY OF JAPAN, LTD.
No.52109
2003/04
TS-C420P9W
Ç

ASSEMBLY AND MOUNTING INSTRUCTIONS

ENGLISH
AIS
DEUTSCHESPAÑOL ITALIANO
Assembly and Mounting Instructions
For Assembly By Authorized Service Personnel Only
Consult authorized service personnel for the installation of this unit. Installation
instructions must be followed precisely in order to prevent accidents. We are
selling this product with the understanding that it will be assembled and installed
by properly trained and qualified service personnel.
FRAN
Danger
We are not liable for any damage caused by faulty assembly,
faulty wall mounting, insecure wall mounting, misuse,
alterations, or natural disasters.
This unit weighs approx. 45 kg (approx. 99 lbs.) including plasma display monitor.
Incomplete or inadequate mounting of this unit to the wall may cause it to fall
down, resulting in potentially fatal accidents.
Please consult authorized service personnel for the installation of this unit.
89 49
300
20°
42-inch Display
16.5
13
13
470
400
2-φ5
4-R10
130
340
<External Dimensions>
Wall Mounting Holes
4-R10
Mass: 10 kg
Angles of Inclination: 0°, 5°, 10°, 15°, 20°
13
13
2-φ5
8190
Wall Mounting Unit
499
81.5159.5
2-φ8
2-φ8
140101.5
20
110 2016020
170131
2020
2020
F
F Section
E
E Section
8.5
50110
Mounting a plasma display television requires specific technical knowledge. Do not attempt to mount the unit by yourself.
Please be aware that screw holes and anchor bolts will remain in the wall surface if the Wall Mounting Unit is removed
after having been mounted to the wall.
Thank you for purchasing this Wall Mounting Unit.
We recommend that you read this manual thoroughly before use in order to familiarize yourself with this unit.
Please store this manual in a safe place after reading it.
TS-C420P9W
Long-term use of the plasma display may result in discoloration of the wall surface due to heat/air emitted by the display.
2-φ8
20
Wall Mounting Unit Exterior
120180
6-R10
(Outer edge)
568
60 120
6-R10
2-φ5
1313
1313
F Section Details
2-φ5
2-φ5
E Section Details
2-φ5
13 1
20
2-φ8
20
2-φ8 1
13
20
(Units in millimeters)
1 13
13 1
2-φ8
VICTOR COMPANY OF JAPAN, LIMITED
© 2003 VICTOR COMPANY OF JAPAN, LIMITED
16
1-2 (No.52109)
TS-C420P9W
3
ENGLISH
Warning
Mounting the Wall Unit
The Wall Mounting Unit should be mounted to a wall that can adequately
hold the total weight of the plasma display and the Wall Mounting Unit
over a long period of time and which can adequately withstand
earthquakes, conceivable vibrations, and other external forces.
Improper installation may cause the plasma display to fall down, resulting
in physical injury.
Mounting On Wooden Walls
The weight of the unit should be borne by the wall posts or studs, and
these should be reinforced if insufficiently strong. Do not install the Wall
Mounting Unit on walls made of plasterboard or thin plywood. Use the
commercially sold screws best suited for the wall structure and material.
Mounting On Concrete Walls
Use commercially sold wall anchors capable of supporting the weight of
the plasma display.
Do not install the Wall
Mounting Unit in a
location which is hot or
humid or which may
become wet, as the
presence of excessive
moisture may lead to
fire or electric shock.
Do not install the Wall
Mounting Unit near the
blower or air inlet of an air
conditioner.
Do not install the unit in a
location with a large
amount of dust, soot, or
cigarette smoke, as this
may lead to fire.
Do not block the
ventilation holes, and be
sure to leave sufficient
space around the unit
for ventilation.
Inadequate ventilation may
cause the unit interior to
overheat, leading to fire.
Plasterboard/Thin Plywood
Do not install the Wall
Mounting Unit in a
location subject to
frequent vibration, impact
or other external forces.
The unit may fall down or
be damaged, causing
physical injury.
Do not install the unit in a
location where people
may hang on it or lean
against it.
Doing so may cause the
unit to fall down or be
damaged, resulting in
injury.
Do not install the unit in
a location exposed to
direct sunlight or strong
light, as viewing the
plasma display in an
overly bright
environment can be
tiring for the eyes.
Do not install the Wall
Mounting Unit on a
non-vertical wall.
The unit interior may
overheat, resulting in fire,
or the unit may fall down,
causing physical injury.
At least
15 cm
At least
20 cm
Explanation of symbols
Safety Precautions
The following section describes the symbols used in this manual. Read this section prior to using the product for correct usage.
The following items contain information for your safety. Follow these precautions precisely.
Warning and Caution are defined as follows:
Danger
Improper handling in disregard of these notices may result in danger of death or bodily harm.
Improper handling in disregard of these notices may result in bodily injury and even death.
Mishandling of the unit in disregard of these notices may result in bodily injury or damage to
Danger
Warning
Caution
Examples:
the unit.
The indicates caution (including warning or danger).
indicates a prohibition, with the specific action indicated either in the circle itself (the
The
symbol at left means "Do Not Disassemble"), or in the accompanying text.
This unit weighs approx. 45kg (approx. 99 lbs.), including display monitor. Improper assembly or
installation may cause the unit to fall when it is mounted, which may result in fatal accidents. To
prevent this happening, check the strength of the materials in the mounting surface, and have at least
two persons carry out the installation in a suitable location. Check the material strength again after
Consult authorized service personnel for the installation and attachment of this unit to the wall.
mounting as well.
Assembly and Mounting Warnings
Warning
bodily injury due to the display monitor and stand toppling over.
Using display monitors other than those authorized by Victor with the unit may result in damage or
mounting falling down, potentially causing damage or bodily injury.
or electric shock.
Assemble all bolts, nuts and screws securely. Failure to do so may result in display monitor and wall
Avoid placing heavy objects on the power cord, as damage to the power cord may result, causing fire
hand as appropriate for the mounting location.
This unit does not come with anchor bolts for securing it to walls, etc. Be sure you have materials on
2
(No.52109)1-3
TS-C420P9W
q Frame
ENGLISH
Wall Mounting Unit
w
5
Flat Washer
Spring Washer
the plasma display to the Wall Mounting Unit. Be sure to keep them in a safe place.
These Frame Fastening Screws, Spacer Rings, Flat Washers, and Spring Washers will be used when attaching
<Before Attaching Plasma Display>
The Wall Mounting Unit is sold with Frame q and Wall Mounting Unit w fixed together. The following steps should
Washer, and Spring Washer.
be performed before attaching the plasma display.
1. Take the left and right Frame Fastening Screw Components and remove the Fastening Screw, Spacer Ring, Flat
Frame Fastening Screw
Spacer Ring
Angle Adjustment Lever
Caution
<Names of Parts>
Frame Removal
Lever Screws
w Wall Mounting Unit
q Frame
Frame q from the Wall Mounting Unit w.
2. Push in the heads of the left and right Frame Removal Lever Screws a and lift up section b to remove the
q
e X 8
Lever Lock Screw
r Angle Adjustment
35-inch
Frame Rotation Shaft
w
X 12
Screws (left/right)
Spacer Rings (left/right)
Frame Attachment Lever Screws
e
Frame
Rotation Jaw
Plasma Display
q
e X 10
PD-42D30ES series
( )
42-inch PD-42DX series
Plasma Display
e Screw (M5 X 30) .......................... 12
r Screw (M5 X 20) ............................ 1
Parts bag
contains:
1-4 (No.52109)
q
installation (i.e., exposed or severed wiring) may result in fire or electric shock.
working under unsuitable conditions.
Consult authorized service personnel for electrical work. Using power cords damaged during
electric shock may result.
Conduct the work with adequate working space. Damage or bodily injury may result from
Avoid mounting this unit in areas where there is electrical wiring or water pipes, as fire or
Tools Required for Assembly:
1. Type 2 Philips Screwdriver (+)
2. Type 2 Philips Screwdriver (+) with 300mm (approx. 12-inch) or longer shaft
50-inch
Frame Fastening Screws left/right
Plasma Display
(Spacer Ring + Flat Washer + Spring Washer)
e X 10
42-inch
Plasma Display
q
<Components List>
q Frame................................................................... 1
w Wall Mounting Unit ............................................... 1
4
Loading...