BEDIENUNGSANLEITUNG : FARB-VIDEO-MONITOR
MANUEL D’INSTRUCTIONS : MONITEUR VIDÉO COULEUR
MANUALE DI ISTRUZIONI : MONITOR VIDEO A COLORI
INSTRUCCIONES : MONITOR DE VIDEO A COLOR
!"#$%&'(&)
INSTRUCTIONS
TM-H1900G
ENGLISH
TM-H1700G
For Customer Use:
Enter below the Serial No. which is located on the rear of the cabinet.
Retain this information for future reference.
Pour l’usage du client:
Enter ci-dessous le numéro de série qui est situé sur l’arrière du coffret.
Conserver cette information pour une référence ultérieure.
Model No. :
Numéro de modèle :
Serial No. :
Numéro de série :
CHROMA
CONTRAST
VOLUME/SELECT
BRIGHT
PHASE
TM-H1900G
(TM-H1900G shown)
(Gezeigtes Modell ist TM-H1900G)
(TM-H1900G montré)
(Modello TM-H1900G)
(Muestra de TM-H1900G)
(
qjJeNVMMd
UNDER
MENU
SCAN
)
AB
INPUT SELECT
DEUTSCH
FRANÇAIS
ITALIANO
ESPAÑOL
POWER
LCT1092-002B-H
INSTRUCTIONS
COLOR VIDEO MONITOR
TM-H1900G
TM-H1700G
ENGLISH
Thank you for purchasing this JVC color video monitor. Before using it, read and follow all
instructions carefully to take full advantage of the monitor’s capabilities.
SAFETY PRECAUTIONS
In order to prevent any fatal accidents caused by misoperation
or mishandling the monitor, be fully aware of all the following
precautions.
WARNINGS
To prevent fire or shock hazard, do not expose this
monitor to rain or moisture. Dangerous high voltages
are present inside the unit. Do not remove the back
cover of the cabinet. When servicing the monitor,
consult qualified service personnel. Never try to service
it yourself.
WARNING : THIS APPARATUS MUST
BE EARTHED.
Machine Noise Information Ordinance 3. GSGV,
January 18, 1991: The sound pressure level at the
operator position is equal or less than 70 dB(A)
according to ISO 7779.
Improper operations, in particular alternation of high
voltage or changing the type of tube may result in x-ray
emission of considerable dose. A unit altered in such a
way no longer meets the standards of certification, and
must therefore no longer be operated.
FCC INFORMATION (U.S.A. only)
CAUTION: Changes or modification not approved by
JVC could void the user's authority to operate the
equipment.
NOTE: This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against
harmful interference in a residential installation. This
equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is
no guarantee that interference will not occur in a
particular installation. If this equipment does cause
harmful interference to radio or television reception,
which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and
receiver.
– Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
– Consult the dealer or an experienced radio/TV
technician for help.
This monitor is equipped with a 3-blade grounding-type
plug to satisfy FCC rule. If you are unable to insert the
plug into the outlet, contact your electrician.
PRECAUTIONS
● Use only the power source specified on the unit.
(120 V AC/230 V AC, 50 Hz/60Hz)
● When not using this unit for a long period of time, or when
cleaning it, be sure to disconnect the power plug from the
AC outlet.
● Do not allow anything to rest on the power cord. And do not
place this unit where people will tread on the cord. Do not
overload wall outlets or power cords as this can result in a
fire or electric shock.
● Avoid using this unit under the following conditions:
– in extremely hot, cold or humid places,
– in dusty places,
– near appliances generating strong magnetic fields,
– in places subject to direct sunlight,
– in badly ventilated places,
– in automobiles with doors closed.
● Do not cover the ventilation slots while in operation as this
could obstruct the required ventilation flow.
● When dust accumulates on the screen surface, clean it with
a soft cloth.
Notice (U.S.A. only)
This product utilizes both a Cathode Ray Tube (CRT) and
other components that contain lead. Disposal of these
materials may be regulated in your community due to
environmental considerations. For disposal or recycling
information please contact your local authorities, or the
Electronics Industries Alliance: <http://
● Unplug this unit from the AC outlet and refer servicing to
qualified service personnel under the following conditions:
– when the power cord is frayed or the plug is damaged,
– if liquid has been spilled into the unit,
– if the unit has been dropped or the cabinet has been
damaged,
– when the unit exhibits a distinct change in performance.
● Do not attempt to service this unit yourself as opening or
removing covers may expose you to dangerous voltage or
other hazards. Always refer servicing to qualified service
personnel.
● When replacement parts are required, have the service
personnel verify in writing that the replacement parts he/
she uses have the same safety characteristics as the
original parts. Use of manufacture’s specified replacement
parts can prevent fire, shock, or other hazards.
● Upon completion of any servicing or repair work to this unit,
please ask the service personnel to perform the safety
check described in the manufacturer’s service literature.
● When this unit reaches the end of its useful life, improper
disposal could result in a picture tube implosion. Ask
qualified service personnel to dispose of this unit.
www.eiae.org.>
2
POWER CONNECTION
The power supply voltage rating of this product is AC 120 V (For U.S.A. and Canada only) and AC 230 V (For European countries
or United Kingdom), the power cord attached conforms to the following power supply voltage and countries. Use only the power
cord designated to ensure Safety and EMC regulations of each countries.
Power cord
Power supply voltage : AC 120 VAC 230 VAC 230 V
Countries: U.S.A. and CanadaEuropean countriesUnited Kingdom
Warning:
● Do not use the same Power Cord for AC 120 V as for AC 230 V. Doing so may cause malfunction, electric shock
or fire.
Note for the United Kingdom power cord only
The plug on the United Kingdom power cord has a built-in fuse. When replacing the fuse, be sure to use only a correctly rated
approved type, re-fit the fuse cover.
(Consult your dealer or qualified service personnel.)
How to replace the fuse
Open the fuse compartment with the blade screw driver, and
replace the fuse.
(* An example is shown in the illustration.)
Fuse
SCREEN BURN
● It is not recommended to keep a certain still image displayed on screen for a long time as well as displaying extremely bright
images on screen. This may cause a burning (sticking) phenomenon on the screen of cathode-ray tube. This problem does
not occur as far as displaying normal video playback motion images.
Supplementary Explanation
= Information for monitor operation =
This monitor uses a high precision CRT (cathode ray tube). Please follow the procedures below.
* For stable operation of the CRT, approximately 30 minutes running time is required from the time the power is turned on.
* When the monitor is installed, it can be easily affected by surrounding magnetic fields, which can generate irregular color
on the screen. When it is difficult to eradicate, degauss from outside using a degausser, etc.
Press this button to activate the picture color density
adjustment mode or picture hue adjustment mode. Each
time you press the button, the adjustment item changes.
Picture color density
Adjust the value with the VOLUME/SELECT buttons
Also used as a control button in the menu function mode.
Contrast/Brightness button
2
[CONTRAST
Press this button to activate the picture contrast adjustment mode or picture brightness adjustment mode. Each
time you press the button, the adjustment item changes.
Picture contrast
Adjust the value with the VOLUME/SELECT buttons
Also used as a control button in the menu function mode.
Volume/Select buttons
3
[VOLUME/SELECT –
Adjusts the speaker volume. Also used as a control
button in the menu function mode.
Menu button [MENU]
4
Displays and disappears the <MENU> screen.
Pressing the CHROMA/PHASE button
button depressed will display the <SET-UP MENU>
screen.
5
Under Scan button [UNDER SCAN]
Reduces the screen size to display the entire image.
Press the button again to cancel Under Scan.
When selected, the Under Scan button lights.
f Picture hue
/ BRIGHT ]
f Picture brightness
+]
1 with the Menu
3.
3.
Input A (VIDEO) button [INPUT SELECT A]
6
Selects the video and audio signals input to the VIDEO A
@ and AUDIO A % terminals on the rear panel. The
button lights when selected.
Input B (VIDEO Y/C) button [INPUT SELECT B]
7
Selects the video and audio signals input to the VIDEO B
# or VIDEO B (Y/C) $ and AUDIO B ^ terminals on
the rear panel. The button lights when selected.
Note:
● The VIDEO B terminals include a video terminal (BNC
connector) and a Y/C terminal (mini-DIN 4-pin connector). The Y/C (S-video) terminal has priority.
Power indicator
8
Unlit: The main power is OFF.
Orange : The main power is ON, but the monitor’s power
is OFF (in the stand-by mode).
Green : The main power is ON, and the monitor’s power
is ON (in the normal operation mode).
Power switch [POWER]
9
Press the power switch to turn the monitor’s power ON or
OFF when the main power is ON.
Note:
● When RUSH DELAY is set to SLOW, it takes about
three seconds before power is actually supplied after
the power switch is pressed.
Speaker
10
A built-in speaker is located inside the right side panel
when the monitor is viewed from the front.
4
REAR VIEW
12
11
13
14
15
16
VIDEO A
AUDIO A
AUDIO B
VIDEO B
INOUT
IN
IN
IN
OUT
OUT
IN
OUT
Y/C
OUT
VIDEO A
REMOTE
AUDIO A
AUDIO B
VIDEO B
INOUT
IN
IN
IN
OUT
OUT
IN
OUT
Y/C
OUT
<Rear Panel>
(Rear view of TM-H1900G shown)
REMOTE (external control) terminal
11
Connect this terminal to an external control unit to enable
remote operation of the monitor.
Refer to the HOW TO USE EXTERNAL CONTROL on
page 15 for more details.
Video A terminals [VIDEO A IN/OUT]
12
Video signal input (IN) and output (OUT) terminals.
The output terminal is bridge-connected.
(The input signal is automatically terminated if a cable is
not connected to the OUT terminal.)
IN: Video signal input terminal
OUT : Bridge-connected video signal output terminal
Notes:
* For corresponding audio signals, use the AUDIO A
terminals
* Also refer to BASIC CONNECTION EXAMPLE
on page 13.
13
Video B terminals [VIDEO B IN/OUT]
Video signal input (IN) and output (OUT) terminals.
The output terminal is bridge-connected.
(The input signal is automatically terminated if a cable is
not connected to the OUT terminal.)
IN: Video signal input terminal
OUT : Bridge-connected video signal output terminal
Notes:
* For corresponding audio signals, use the AUDIO B
terminals
* Also refer to BASIC CONNECTION EXAMPLE on
page 13.
14
Video B (Y/C) terminals [VIDEO B Y/C IN/OUT]
Y/C (S-video) signal input (IN) and output (OUT) terminals.
The output terminal is bridge-connected.
(The input signal is automatically terminated if a cable is
not connected to the OUT terminal.)
%.
^.
IN: Y/C-separated (S-video) video signal input
terminal
OUT : Bridge-connected Y/C-separated (S-video) signal
output terminal.
ENGLISH
Notes:
* For corresponding audio signals, use the AUDIO B
terminals
^.
* When both VIDEO B terminals are connected (input) at
the same time, the Y/C terminal has priority.
* Also refer to BASIC CONNECTION EXAMPLE
on page 14.
Audio A terminals [AUDIO A IN/OUT]
15
Input (IN) and output (OUT) terminals for the audio signal
corresponding to the VIDEO A terminals
@.
The output terminal is bridge-connected.
IN: Audio signal input terminal
OUT : Bridge-connected audio signal output terminal
Notes:
* For corresponding video signals, use the VIDEO A
terminal
@.
* Also refer to BASIC CONNECTION EXAMPLE
on page 13.
16
Audio B terminals [AUDIO B IN/OUT]
Input (IN) and output (OUT) terminals for the audio
signals corresponding to the VIDEO B terminals
#
VIDEO B (Y/C) $.
The output terminal is bridge-connected.
IN: Audio signal input terminal
OUT : Bridge-connected audio signal output terminal
Notes:
* For corresponding video signals, use the VIDEO B
terminals
# or VIDEO B (Y/C) terminals $.
* Also refer to BASIC CONNECTION EXAMPLE
on pages 13 and 14.
5
VIDEO A
REMOTE
AUDIO A
AUDIO B
VIDEO B
INOUT
IN
IN
IN
OUT
OUT
IN
OUT
Y/C
OUT
18
17
19
19
19
CONTROLS AND FEATURES (cont’d)
REAR VIEW
<Rear Panel>
To AC outlet
(120 V AC,
50 Hz/60 Hz)
To AC outlet
(230 V AC,
50 Hz/60 Hz)
For U.S.A. and Canada
For Europe
(Rear view of
TM-H1900G shown)
For the United Kingdom
Main power switch
17
Press the switch to turn the main power ON or OFF. When
the main power is ON, the power indicator on the front
panel lights in orange and the monitor enters the stand-by
mode.
I : ON : OFF
AC inlet [AC IN]
18
Power input connector. Connect the provided AC power
( to an AC outlet (120 V AC or 230 V AC,
cord
50 Hz/60 Hz).
Power cord
19
Connects the provided power cord (120 V AC or
230 V AC, 50 Hz/60 Hz) to the AC IN connector
Caution:
In North America (USA and Canada), this monitor comes
with one power cable. In Europe and the United Kingdom, two power cables are provided (one for use in
continental European countries and the other for the UK).
Be sure to use the power cable that is appropriate for the
AC outlets used in your region. If none of the power
cables provided is suitable, please contact your dealer or
qualified service personnel to obtain the correct type of
power cable.
*.
6