STANDARD CIRCUIT DIAGRAM
NOTE ON USING CIRCUIT DIAGRAMS
1.SAFETY
The components identified by the symbol and shading are
critical for safety. For continued safety replace safety critical
components only with manufac tures recommended pa rts .
2.SPECIFIED VOLTAGE AND WAVEFORM VALUES
The voltage and waveform values have been measured under the
following conditions.
(1)Input signal : Colour bar signal
(2)Setting positions of
each knob/button and
variable resistor
(3)Internal resistance of tester
:DC 20k
/V
(4)Oscilloscope sweeping time
:H
20µS/div
:V
5mS/div
:Others
Sweeping time is
specified
(5)Voltage values
:All DC voltage values
Sin ce th e vo l tage val ue s of si gn a l cir cui t va ry to some ex ten t
according to adjustments, use them as reference values.
3.INDICATIONS ON THE CIRCUIT DIAGRA M
(1)Resistors
Resistance value
No unit :[
]
K
:[K
]
M
Type
No indica tion
:Carbon resistor
OMR
:Oxide metal film resistor
MFR
:Metal f ilm resistor
MPR
:Metal plate resistor
UNFR
:Uninflammable resistor
FR
:Fusible resistor
Compos ition resistor 1/ 2 [W] is specified as 1/2 S or C omp.
(2)Capacitors
: Original setting position
when shipped
4.NOTE FOR RE PAIRIN G S ERVICE
This model's power circuit is partly different in the GND. The
difference of the GND is shown by the LIVE side GND and the
ISOLATED(NEUTRAL) side GND.Therefore, care must be
taken for the following points.
(1)Do not touch the LIVE side GND or the LIVE side GND an d the
ISOLATED(NEUTRAL) side GND simultaneously. If the above
caution is not respected, an electric shock may be caused.
Therefore, make sure that the power cord is surely removed from
the receptacle when, for example, the chassis is pulled out.
(2)Do not short between the LIVE side GND and ISOLATED(NEUTRAL)
side GND or never measure with a measuring apparatus measure
with a measuring apparatus ( oscilloscope, etc.) the LIVE side GND
and ISOLATED(NEUTRAL) side GND at the same time.
If the above precaution is not respected , a fuse or any parts will be broken.
Since the circuit diagram is a standard one, the circuit and
circuit constants may be subject to change for impro vement
without any notice.
NOTE
Due improvement in performance, some part numbers show
in the circuit diagram may not agree w ith those i ndicated in
the part list.
When ordering parts, plea se use t he numbers that appear
in the Parts List.
Type
MM
:M etal ized mylar capa c i tor
PP
:Polypropylene capacitor
MPP
:Metalized polypropylene capacitor
MF
:Metaliz ed film capa c itor
TF
:Thin film capacitor
BP
:Bipolar electrolytic capaci tor
TAN
:Tant alum capa citor
(3)Coils
No unit
:[
µ
H]
Others
:As specified
:[M ]
Capacitance value
1 or higher :[pF]
less than 1
:[µF]
Withstand voltage
No indica tion :DC 50[V]
Others :DC withstand voltage [V]
AC indicated
:AC withstand voltage [V]
Electrolytic Capacitors
47/50[Example]:Capacitance value [µF]/withstand voltage[V]
No indication
:Ceramic capacitor
AV-29BF11ENS
AV-29BF11EPS
AV-29BF11EES
Sep. 2002 No. 52084