STANDARD CIRCUIT DIAGRAM
NOTE ON USING CIRCUIT DIAGRAMS
1.SAFETY
The components identified by the  symbol and shading are 
critical for safety. For continued safety replace safety critical  
components only with manufactures recommended parts.
2.SPECIFIED VOLTAGE AND WAVEFORM VALUES
The voltage and waveform values have been measured under the  
following conditions.
(1)Input signal : Colour bar signal
(2)Setting positions of  
  each knob/button and  
  variable resistor
(3)Internal resistance of test er
:DC 20k
/V
(4)Oscilloscope sweeping time
:H 
20µS/div
:V 
5mS/div
:Others
Sweeping time is  
specified
(5)Voltage values
:All DC voltage values
Since the voltage values of signal circuit vary to some extent  
according to adjustments, use them as reference values.
3.INDICATION OF PARTS SYMBOL [EXAMPLE]
In the PW board
:R1209
R209
4.INDICATIONS ON THE CIRCUIT DIAGRAM
(1)Resistors
Resistance value 
No unit :[
]
K
:[K
]
M
Rated allowable power 
No indication :1/ 16   [W] 
Others :As specified
Type 
No indication
:Carbon resistor 
OMR
:Oxide met al fil m resistor 
MFR
:Metal film resist or 
MPR
:Metal plate resistor 
UNFR
:Uninflammable resistor 
FR
:Fusible resistor
Composition resistor 1/2 [W] is specified as 1/2S or Comp.
(2)Capacitors
: Original setting position  
 when shipped
5.NOTE FOR REP AIRING SERVICE
This model's power  circuit is par tly different in the GND. The  
difference of the GND is shown by the LIVE : (   ) side GND and the  
ISOLATED(NEUTRAL) : (  ) side GND.Therefore, care must be  
taken for the following points.
(1)Do not touch the LIVE side GND or the LIVE side GND and the  
  ISOLATED(NEUTRAL) side GND simultaneously. If the above  
  caution is not respected, an electric shock may be caused.  
  Therefore, make sure that the power cord is surely removed from  
  the receptacle when, for example, the chassis is pulled out.
(2)Do not short between the LIVE side GND and ISOLATED(NEUTRAL)  
  side GND or never measure with a measuring apparatus measure  
  with a measuring apparatus ( oscilloscope, etc.) the LIVE side GND  
  and ISOLATED(NEUTRAL) side GND at the same time.  
  If the above precaution is not respected , a fuse or any parts will be broken.
Since the circuit diagram is a standard one, the circuit and  
circuit constants may be subjec t to chang e for improvement  
withou t any notice.
NOTE 
Due  improvement  in  performance,  some  part numbers show  
in  the  circuit diagram may not agree with those indicated in  
the part list. 
When ordering  parts, please  use  the numbers that appear  
in the Parts List.
Type
MM
:Metalized mylar capacitor
PP
:Polypropylene ca pacitor
MPP
:Metalized polypropylene capacitor
MF
:Metalized f ilm capacitor
TF
:Thin film capacitor
BP
:Bipolar electrolytic capaci tor
TAN
:Tantalum capacitor
(3)Coils
No unit
:[
µ
H]
Others
:As specified
(4)Power Supply
:B1
:9V
:5V
Respective voltage values are indicated
(5)Test point
:T est po int
:Only test point display
(6)Connec ting method
:Connector
:Wrapping or s oldering
:Receptacle
 (7)Ground symbol
:LIVE side ground 
:ISOLATED(NEUTRAL) side g round 
:EARTH ground 
:DIGITAL ground
:[M ]
Capacitance value
1 or higher :[pF]
less  than 1
:[µF] 
Withstand voltage 
No indication  :DC 50[V]
Others :DC withstand voltage [V] 
AC indicated 
:AC withstand voltage [V] 
Electrolytic Capacitors
47/50[Example]:Capacitance value [µF]/withstand voltage[V]
No indication :Ceramic capacitor
:B2 (12V)